CABLE MASTER Multifunctional OPM with VFL Flashlight and RJ-45 Wiremap User Manual

May 15, 2024
CABLE MASTER

CABLE MASTER Multifunctional OPM with VFL Flashlight and RJ-45 Wiremap

Product Information

Specifications:

  • OPM Detector Type: lnGaAs
  • Working Wavelength: 800nm-1700nm
  • Display Resolution: 0.01 dBm
  • Frequency identification: 270Hz/330Hz/1 kHz/2kHz
  • Optical Port: 2.5mm universal FC/SC/ST
  • VFL Working Wavelength: 850/1300/1310/1490/1550/1625/1650
  • Battery: 3 x AAA NiMH 1.2V Batteries
  • Continuous working time: Not specified
  • Auto Power-Off: Yes
  • Working Temp: Not specified
  • Storage Temp: Not specified
  • Storage Humidity: Not specified
  • Dimension: Not specified
  • Weight: Not specified

Product Usage Instructions

  1. Powering On and Off:
    To power on, press the Power button (K1) once. To power off, long-press the Power button.

  2. Calibration Mode:
    To enter Calibration Mode, press K2 and K5 simultaneously. In Calibration Mode, use K3 and K4 to increase or decrease values respectively. Save the current reference value by pressing K1.

  3. Using the VFL:
    Press the VFL button (K6) to switch between CW/1Hz/2Hz working modes. Select the desired wavelength using the corresponding keys.

  4. Maintenance:
    Clean the device regularly with optical cleaning materials when dirty. Avoid getting cleaning agents inside the device.

FAQ:

  • Q: How do I charge the device?
    A: The device can be charged using the Type-C USB Charging Port (Interface Description – No.4).

  • Q: What is the battery type used in the device?
    A: The device uses 3 x AAA NiMH 1.2V Batteries.

Introduction

The CableMaster-FO is a multifunctional Optical Power Meter of Softing integrates the functions of an optical power meter, VFL, RJ45 network cable test, flashlight and other functions. The design is small and lightweight, sturdy and durable, and is suitable for applications such as FTTX broadband installation and maintenance tests and optical fibre network cable comprehensive tests.

Features

  • Solid, Robust and Durable
  • Multifunction in one (optical power meter, VFL, RJ45 network cable test, flashlight)
  • Universal Optical Interface (SC/FC/ST)
  • Multi-Unit Display (dBm/dB/mW)
  • Support relative value measurement function
  • Support user calibration function
  • Support USB interface charging (optional)
  • Support over 80 hours of continuous use time (only OPM mode)
  • Smart power saving

Test Range| Supported Wavelengths| Accuracy| VFL Output Power
---|---|---|---
-70dBm~+10dBm@1550nm| 850/1300/1310/1490/1550/1625/1650nm| ±0.35dB| 0 dBm
1 mW

WARNING:
When using a dry battery for the power supply, it is forbidden to connect an external power adapter to prevent danger.

Specifications

OPM

  • Detector Type InGaAs
  • Working Wavelength 800nm-1700nm
  • Display Resolution 0.01 dBm
  • Frequency identification 270Hz/330Hz/1 kHz/2kHz
  • Optical Port 2.5mm universal FC/SC/ST

VFL

  • Working Wavelength 650nm±30nm
  • Output Mode CW/1Hz/2Hz
  • Optical Port 2.5mm universal FC/SC/ST

Others

  • Battery Ni-MH rechargeable battery
  • Continuous working time 80 hours(only OPM mode)
  • Auto Power-Off 10 minutes
  • Working Temp -10°C – +50°C
  • Storage Temp -25°C – +70°C
  • Storage Humitidy 0 – 95% (No condensation)
  • Dimension 105L x 65W x 25H (mm)
  • Weight 140g

Panel Definition

Key

| Short Press|

Long Press

---|---|---
K1| Power ON

(Short Press after power on to disable Auto-Power-OFF Function)

Save the current Reference value in Calibration-Mode (CAL)

| Power OFF
K2| Recall of stored data (up to 50 results)| Save current value
K3| Switch Units (db, dBm, mW)
Value increase by 0.05 dB in Calibration-Mode (CAL) Recall / Scroll the stored Data| Set current Power as a Reference value
K4| VFL Button, switch CW/1Hz/2Hz working Mode
Value decrease by 0.05 dB in Calibration-Mode (CAL) Recall / Scroll the stored Data|
K5| Turn ON/OFF Screen Backlight| Flashlight
K6| Wavelength selection 850/1300/1310/1490/1550/1625/1650|
K2+K5| Enter/Quit Calibration-Mode (CAL)|
K3+K5| Restore factory calibration value settings|

Interface Description

No.

| Function|

Description

---|---|---
1| VFL| VFL Port
2|  | LED Flashlight
3| OPM| Optical Powermeter Port
4|  | Type-C USB Charging Port
5|  | RJ-45 Port and RJ-45 Remote Module used for Patchcord Wiremap Test

Maintenance

  • If using dry battery version do not charge the device
  • It is recommended to clean the universal connector of the device and the measuring cable regularly, at the latest when they become dirty through use. Optical cleaning materials are recommended.
  • Please make sure that the cleaning agent does not get inside the device.

Package Contents

How to open the CableMaster FO top cover

itnetworks.softing.com/cmFO.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals