ideal lux AP1 D20 Mapa Indoor Wall Light Instruction Manual
- May 15, 2024
- ideal lux
Table of Contents
ideal lux AP1 D20 Mapa Indoor Wall Light
Product Specifications:
- Model: Mapa Bianco AP1 D20
- Socket Type: E27
- Maximum Wattage: 1 x 60W
- Voltage: 220-240V, 50/60Hz
- Barcode: 8021696059815
- Color: BIANCO
Product Usage Instructions
Installation:
The lighting fitting should be installed by a qualified electrician. Follow
the assembly instructions provided in numerical order.
Specifications for Installation:
- Terminals: IP20, requires 2 x 0.75 mm2 (not included)
Safety Instructions:
- Ensure the appliance complies with European safety standards EN 60 598-1.
- Seek advice from local authorities on disposal methods.
Additional Safety Instructions (Italian):
- The appliance must comply with European safety standards EN 60 598-1.
- Installation should be carried out by a qualified electrician according to regulations.
- If the external electric cable is damaged, it should only be replaced by the manufacturer, retailer, or a qualified electrician.
- Always disconnect the power supply before starting installation or any maintenance work.
- The appliance has parts that can become hot.
- Use specific fixing accessories for each material; use suitable screws and plugs complying with regulations.
Frequently Asked Questions (FAQ):
-
Q: What should I do if the lamp does not turn on?
A: Check and replace the fuse if necessary. -
Q: Is grounding mandatory for this product?
A: Yes, grounding is mandatory for electrical safety. Please ensure proper grounding during installation. -
Wall and ceiling lamp
-
E27 max 1 x 60W / 220-240V 50/60Hz – 8021696059815 BIANCO
Warning
ASSEMBLY INSTRUCTIONS
FOLLOW THE ASSEMBLY INSTRUCTIONS BY READING THE NUMERICAL PROGRESSION
THE LIGHTING FITTING SHOULD BE INSTALLED BY A QUALIFIED ELECTRICIAN
SAFETY INSTRUCTIONS
- This fitting is produced and tested in accordance with the strictest European safety standards (EN 60.598-1).
- This fitting cannot be disposed of as household waste. For disposal information ask the local authorities about how to collect it.
- As indicated by specific regulations, the lighting fitting should be installed by a qualified electrician.
- If the external wire is damaged it has to be replaced exclusively by the manufacturer, distributor or by a qualified electrician.
- Always isolate power before commencing installation, maintenance or repair.
- The luminaire contains certain parts which can be very hot.
- Each material requires specific mounting accessories. Use screws and wall plugs suitable for the material to which they are fastened. Those included may be unsuitable.
- Always tighten the screws firmly to avoid contact problems.
- This fitting should only be installed indoors.
- Luminaires not suitable for recessed on normally flammable surfaces.
- Luminaire not suitable for direct mounting on normal flammable surfaces.
- This fitting is only suitable for fixing to the ceiling.
- This fitting is only suitable for fixing to the wall.
- The weight of the lamp has to be supported by the chain. Adjust the length of the electric wire so that it is longer than the chain.
- Only use lamps which do not exceed the maximum specified wattage.
- Always observe the minimum distance between the lamp and the surface being lit, as shown in the icon. The lamp can cause a fire if the minimum distance is not observed.
- Auto-protected bulb. Only use bulbs marked with this symbol. Halogen bulbs get very hot. Wait until they cool down before replacing.
- Cracked or broken safety glass has to be replaced immediately. Use only manufcturer approved parts complying with regulations.
- Light source with not-substitutable light emitting diode (LED). Do not disassemble the product since the diodes can damage the eyes. Do not immerse in water. Wipe with a damp cloth. Do not use solvents or strong detergents.
- This fitting is equipped Wläh a fuse. If the lamp is out of order, replace the internal fuse.
- Class I Electrical safety guaranteed by the main insulation and an additional protective conductor (earthing) connected with the metal frame of the lamp. Earthing is obligatory.
- Class II Electrical safety guaranteed by the main insulation and a double or reinforced insulation. Earthing not necessary.
- Class Ill Electrical safety guaranteed by very low power supply (less than 50 Volt). Earthing excluded.
- Not protected.
- Protected against solid objects greater than 50 mm.
- Protected against solid objects greater than 1 2 mm.
- Protected against solid objects greater than 2,5 mm.
- Protected against solid objects greater than 1 mm.
- Dust protected.
- Totally protected against dust infiltration.
- Not protected.
- Protected against vertically falling water drops.
- Protected against water drops falling with a maximum angle of 1 50 to the vertical axis.
- Protected against rain.
- Protected against splashing water.
- Protected against water jets.
- Protected against strong water jets.
- Protected against temporary immersion.
- Protected against prolonged immersion.
- Luminaire not suitable for covering with thermally insulating material.
- Caution, risk of electric shock.
- Do not stare at the operating light source.
IDEAL LUX s.r.l.
Via Taglio Destro 32
30035 Mirano (VE) Italy
www.ideal-lux.com
IDEAL LUX Warehouse
Via delle Industrie, 8/D
30036 Santa Maria di Sala (Venezia)
8.00 – 12.00 / 13.30 – 17.00
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>