Chint CS500 Ceiling Fan With Light User Manual

May 15, 2024
Chint

Chint CS500 Ceiling Fan With Light

Chint-CS500-Ceiling-Fan-With-Light-product

Safety Information

READ AND SAVE THESE INSTRUCTIONS.

  1. To reduce the risk of electric shock, ensure electricity has been turned off at the circuit breaker or fuse box before you begin.
  2. All wiring must be by the National Electrical Code “ANSI/NFPA 70” and local electrical codes. Electrical installation should be performed by a qualified licensed electrician.
  3. The outlet box and support structure must be securely mounted and capable of reliably supporting a minimum of 35 lbs (15.9 kg). Use only UL-listed outlet boxes marked “ Acceptable for Fan Support of 35 lbs. (15.9 kg) or less. ”
  4. Do not place objects in the path of the blades.
  5. To clean the fixture, turn off the power, wait for it to cool, and wipe the fixture with a clean, soft cloth.
  6. After making electrical connections, spliced conductors should be turned upward and pushed carefully up into the outlet box.
  7. The wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and the ungrounded conductor on the other side of the outlet box.
  8. All set screws must be checked and retightened where necessary before installation.

WARNING: To reduce the risk of electrical shock or fire, do not use this fan with any solid-state fan speed control device. It will permanently damage the electronic circuitry.
WARNING: To reduce the risk of personal injury, do not bend the blade brackets when installing the rackets balancing the blades, or cleaning the fan. Do not insert balancing the blades, or clean the fan. Do not insert
WARNING: To reduce the risk of fire, electric shock or personal injury, mount to the outlet box marked “acceptable for fan support of 35 lbs. (15.9 Kg) or less” and use the screws provided with the outlet box.
WARNING : To avoid possible electrical shock, turn the electricity off at the main fuse box before wiring.
WARNING: To reduce the risk of electrical shock, this must be installed with an isolating wall control/switch.
CAUTION: To reduce the risk of personal injury, use only the screws provided with the outlet box.
CAUTION: Please use carefully when working around or cleaning the fan to avoid injury or ) damage to the fan.
CAUTION: The fan must be mounted with a minimum of 7 ft (2.1 m) clearance from the trailing) edge of the blades to the floor.
CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Dimension Reference

Chint-CS500-Ceiling-Fan-With-Light-fig-1

Hardware Included

Fan Parts Included

Chint-CS500-Ceiling-Fan-With-Light-fig-3

Item Name Quantity

  1. Installation Plate  1
  2. Item Name 1
  3. Motor Assembly  1
  4. Remote Control Emitter Batteries not included) 1

STEP.1 INSTALLATION WALL STOPPER

Caution: Turn off all switches and make sure there is no power when installing. If it is a cement roof, four holes need to be drilled according to the position of the holes on the installation plate, and then inserted into the wall plug. If it’s a wooden roof, it doesn’t need to be.

Chint-CS500-Ceiling-Fan-With-Light-fig-4

STEP.2 INSTALLATION PLATE

  • Thread the power cord through the holes on the installation plate and lock it at the top with four wooden screws.
  • Remove two symmetrical screws from the installation plate.Chint-CS500-Ceiling-Fan-With-Light-fig-5

STEP.3 INSTALLATION MOTOR ASSEMBLY
Hang the safety rope of the fan onto the hook on the installation plate.

Chint-CS500-Ceiling-Fan-With-Light-fig-6

  • Connect the green ground wire to the ground wire. Connect the white wire to the zero wire. Connect the black wire to the firewire.Chint-CS500-Ceiling-Fan-With-Light-fig-7
  • Clip the keyhole on the fan connection plate into the two screws on the installation plate.Chint-CS500-Ceiling-Fan-With-Light-fig-8
  • Then tighten the four screws.Chint-CS500-Ceiling-Fan-With-Light-fig-9

Remote control instruction

  • Please pair the remote with the fan before using it.
  • Open the battery cover on the hand-held remote and install a battery, pair of AAA emitters (1.5V) that are not included.Chint-CS500-Ceiling-Fan-With-Light-fig-10

Remote control pairing code
Turn on the power, and press the pairing code button within 5 seconds. When you hear a “beep” sound or the light flashes, the code pairing is successful. If you need to match the code again, wait 30 seconds and repeat the above operations

Troubleshooting Guide

If you have difficulty operating your new ceiling fan it may be the result of incorrect assembly, installation, or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults please check this troubleshooting guide.

Chint-CS500-Ceiling-Fan-With-Light-fig-12Chint-
CS500-Ceiling-Fan-With-Light-fig-13

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals