ROLACHEM RC25 53 Peristaltic Pump Instruction Manual
- May 15, 2024
- ROLACHEM
Table of Contents
PRO SERIES 300 PUMP
Installation & Parts Manual
IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
Safety Instructions
1. SAFETY: When installing and using this electrical equipment, basic
safety precautions should always be followed, including:
1.1 WARNING! To reduce the risk of injury, do not permit children to use
this product unless they are closely supervised at all times.
1.2 WARNING! Risk of electric shock.
Connect only to a grounding type receptacle protected by a ground-fault
circuit interrupter (GFCI). Contact qualified electrician if you cannot verify
that the receptacle is protected by a GFCI and that your installation meets
local electrical codes, including grounding of water system components.
1.3 WARNING! Risk of electric shock.
Do not bury or modify the metering pump cord. Locate cord to minimize abuse
from lawn mowers, hedge trimmers, and other equipment.
1.4 WARNING! Risk of electric shock.
On cord and plug-connected units, replace a damaged cord immediately.
1.5 WARNING! Risk of electric shock.
Do not use extension cord to connect unit to electrical supply; provide a
properly located outlet.
1.6 WARNING! Risk of electric shock.
Do not install within an outer enclosure or beneath the skirt of a hot tub or
spa unless so marked. All instructions must be in accordance with appropriate
electrical codes.
1.7 WARNING! Risk of electric shock/pinching/chemical exposure.
Remove power sources or lockout circuit prior to performing maintenance on
metering pump.
Pumps are usually timer controlled and can start at any time.
1.8 WARNING! Risk of Chemical Overdose/Exposure.
Removing power from circulating pump must also remove power from the chemical
injection pump. Provide a properly located outlet controlled by the
circulating pump circuit.
1.9 WARNING! Risk of Chemical Overdose/Exposure.
Use a device such as a flow switch to shut off power from the from the
chemical injection pump in the event of pool pump or circulation failure.
It is not safe to automatically dispense chemicals into a circulating system
that is not running.
1.10 WARNING! Risk of Chemical Overdose/Exposure.
Minimize amount of chemical on site that is available to dispense.
Size the feeder and container to pool/spa capacity.
Dilute chemical for small bodies of water.
1.11 WARNING! Risk of Chemical Exposure.
Depressurize the system prior to connecting or disconnecting the metering
pump.
1.12 CAUTION! Wear protective clothing, gloves and safety glasses at all
times when working on or near the metering pump.
1.13 CAUTION! Install the metering pump and chemical containers in a
ventilated secured location. Protect children, pets, and property from
chemical hazards. Containment and/or wash down capability must be in
accordance with local regulations and chemical suppliers’ instructions.
1.14 CAUTION! Read and follow all instructions supplied with the chemical
being fed. User is responsible for determining the compatibility of the
chemical with the metering pump.
Consult supplier of chemical if use and handling instructions are not
available.
1.15 CAUTION! This pump is for use with permanently installed pools and
may also be usedwith hot tubs and spas. Do not use with storable pools. A
permanently installed pool is constructed in or on the ground or in a building
such that it cannot be readily disassembled for storage. A storage pool is
constructed so that it is capable of being readily disassembled for storage
and reassembled to its original integrity.
1.16 CAUTION! Service tubing regularly, e.g. when refilling chemical
container. See OPERATION and MAINTENANCE sections for details.
Specifications
Power: 120 volt AC (corded) or 240 volt AC (conduit), 50/60 HZ, 2.5 amp
(max.)
Pressure / suction: 30 psi max. dispense line pressure. RC307 maximum
dispense line pressure is 25 psi. 18-foot max. inlet suction lift.
Feed Capacity: Estimated maximum gallons per day (GPD) in Continuous
mode.
RC301 | RC303 | RC305 | RC307 |
---|---|---|---|
0.9 | 12 | 38 | 77 |
To calculate estimated feed rate for Timer settings, multiply the Continuous
mode rating from above by the percentage setting or see table on next page.
Example for an RC305 set to 50%: 38 gallons per day x 50% = 19 GPD.
Available TIMER settings include increments of 1% from 1 – 10%, increments of
5% from 10 – 95% and 99%.
Capacity in this table is intended as a guide. Actual output may vary based on
actual environment.
Conversion from Legacy Pro Series Knob Setting to Percent Setting
Legacy Pro Series Knob Setti ng| Percent Setting
Lo| 1
2| 215
3| 335
4| 450
5| 570
6| 680
HI| 99
Estimated feed rates at given Timer settings
– Gallons per Day (GPD)
Setting (%)| On Time| Off Time| RC301| RC303|
RC305| RC307
---|---|---|---|---|---|---
1| 5.4 SEC| 8.9 MIN| 0.01| 0.12| 0.38| 0.77
2| 10.8 SEC| 8.8 MIN| 0.02| 0.24| 0.76| 1.54
3| 16.2 SEC| 8.7 MIN| 0.03| 0.36| 1.14| 2.31
4| 21.6 SEC| 8.6 MIN| 0.04| 0.48| 1.52| 3.08
5| 27.0 SEC| 8.6 MIN| 0.05| 0.60| 1.90| 3.85
6| 32.4 SEC| 8.5 MIN| 0.05| 0.72| 2.28| 4.62
7| 37.8 SEC| 8.4 MIN| 0.06| 0.84| 2.66| 5.39
8| 43.2 SEC| 8.3 MIN| 0.07| 0.96| 3.04| 6.16
9| 48.6 SEC| 8.2 MIN| 0.08| 1.08| 3.42| 6.93
10| 54.0 SEC| 8.1 MIN| 0.09| 1.20| 3.80| 7.70
15| 1.4 MIN| 7.7 MIN| 0.14| 1.80| 5.70| 11.55
20| 1.8 MIN| 7.2 MIN| 0.18| 2.40| 7.60| 15.40
25| 2.3 MIN| 6.8 MIN| 0.23| 3.00| 9.50| 19.25
30| 2.7 MIN| 6.3 MIN| 0.27| 3.60| 11.40| 23.10
35| 3.2 MIN| 5.9 MIN| 0.32| 4.20| 13.30| 26.95
40| 3.6 MIN| 5.4 MIN| 0.36| 4.80| 15.20| 30.80
45| 4.1 MIN| 5.0 MIN| 0.41| 5.40| 17.10| 34.65
50| 4.5 MIN| 4.5 MIN| 0.45| 6.00| 19.00| 38.50
55| 5.0 MIN| 4.1 MIN| 0.50| 6.60| 20.90| 42.35
60| 5.4 MIN| 3.6 MIN| 0.54| 7.20| 22.80| 46.20
65| 5.9 MIN| 3.2 MIN| 0.59| 7.80| 24.70| 50.05
70| 6.3 MIN| 2.7 MIN| 0.63| 8.40| 26.60| 53.90
75| 6.8 MIN| 2.3 MIN| 0.68| 9.00| 28.50| 57.75
80| 7.2 MIN| 1.8 MIN| 0.72| 9.60| 30.40| 61.60
85| 7.7 MIN| 1.4 MIN| 0.77| 10.20| 32.30| 65.45
90| 8.1 MIN| 54.0 SEC| 0.81| 10.80| 34.20| 69.30
95| 8.6 MIN| 27.0 SEC| 0.86| 11.40| 36.10| 73.15
99| 8.9 MIN| 5.4 SEC| 0.89| 11.88| 37.62| 76.23
On| Continuous| | 0.90| 12.00| 38.00| 77.00
Installation
Tools required – Phillips screwdriver & adjustable wrench, 23/32” drill & ½” pipe tap (NPT) or 7/16” drill & ¼ “ pipe tap (NPT)
3.1 Install the ROLA-CHEM® pump in an area protected from natural elements
(sun, rain, freezing, etc.).
Environmental effects may increase required service and maintenance.
The inlet side of the pump must be above the incoming liquid and the chemical
container.
Flooded suction is not required or recommended.
Ensure that the tube can be routed without allowing it to kink.
Do not install directly above the chemical container or other equipment that
can be damaged by chemicals. Wall mounting key slots are provided on the rear
of the pump enclosure (For #10 screws, 6-1/4” apart for horizontal mount,
4-1/16” for vertical mount and 3-7/8” for two-hole center mount).
Comply with local health codes. Cross connections must not allow undesired
chemical treatment. MOUNTING HOLES
*SAME AS LEGACY PRO-SERIES
3.2 For chlorine pumps, undiluted swimming pool grade 15% maximum sodium
hypochlorite may be used. For acid pumps, 32% maximum hydrochloric acid may be
used. Black Norprene Pinch Tube is included for use with hydrochloric acid.
See sizing for dilution.
3.3 Connect the injection fitting into the line to be treated. This should be
after the heater. Use pipe tape to seal the pipe threads. If two chemicals are
being injected and no controller is being used to prevent chemical mixing,
space the injection points at least one foot apart to prevent mixing. Do not
exceed pressure / suction specifications.
A check valve may be used at the point of injection to prevent backflow, then
the tubing assembly can be disconnected at its connection to the check valve
and it will not be necessary to plug the injection fitting hole.
For installation where pressure is greater than 20 psi, use a check valve as
the injection fitting or in-line before injection fitting. One 3 /8 barbed
check valve and one barbed inlet x ¼ NPT (American National Standard Taper
Pipe Thread) outlet check valve are included with standard pumps. Use tubing
clamp over tube on barbed ends of fitting on outlet side of pump.
For low pressure applications, a brass injection fitting will fit a ½ NPT
connector or a ½ NPT hole tapped into heavy gage pipe. Push the vinyl tube
through the fitting until it hits the bottom of the pipe, then pull it back
about ¼ inch. This creates an outlet for chlorine away from the injector
fitting and helps the injector fitting from becoming clogged. For
installations where a ¼ NPT injection port connection is already available, a
¼ NPT adapter with a tubing clamp is included in the literature kit.
CAUTION! Do not install injection fitting directly into copper lines (may
cause corrosion and discoloring).
3.4 Place the suction tubing in the chemical container with the weight lying
on its side. This will keep the end of the suction tubing off the bottom to
allow for sediment.
3.5 Electrical hook-up must comply with Code, including safety devices.
Voltage must be per the data plate.
CAUTION! Pump must be wired to prevent overdosing. Connect pump to turn
off when circulating system is off. Connect pump power to a flow switch on the
return piping (if circulation system stops, chemical pump must stop).
CAUTION! Pump must be turned off when backwashing filters
Internal Wiring Diagrams
Operation
4.1 Before placing the ROLA-CHEM® pump in operation, lubricate the Pinch Tube
with silicone lubricant (supplied in the literature kit) and install per Pinch
Tube Assembly replacement instruction section 5.2. NOTE: Maintain
lubrication on the Pinch Tube at all times. Intervals for applying lubrication
vary with pump size, frequency of operation and pressures.
To access the Pinch Tube Assembly, remove the knob from the front of the pump
housing.
Rotate the housing cover counterclockwise and lift off the cover, or on the
RC301 Models remove wing nuts and lift off the body half. Reverse steps to
reassemble.
CAUTION! Remove power from pump when lubricating Pinch Tube. Do not
remove Pinch Tube Assembly from pump housing while system is under pressure.
4.2 The Mode setting has TIMER, CONTINUOUS and OFF positions. For interrupting
action, use the TIMER position and adjust the percent setting using the
Up/Down buttons for the desired output. For use with a controller (and for
continuous, non-stop chemical feeding) use the CONTINUOUS position.
NOTE: When operated using an external controller, the Pump display will
turn off when the Controller is not in a feed cycle and Pump settings cannot
be adjusted. In order to view and adjust the Pump settings: 1) temporarily set
the external controller feed time to 30 seconds or more. 2) Start a feed cycle
on external controller and set the pump mode to CONTINUOUS while feed cycle is
still active. 3) Set intended feed time on external controller.
See Controller manual for details on adjusting feed time and initiating a feed
cycle. Or set Pump mode by temporarily connecting the pump directly to a power
source.
TIMER reduces the output by interrupting the chemical feeding for the selected
portion of its nine-minute timing cycle (setting of 50% provides approximately
4.5 minutes on and 4.5 minutes off). The pump will feed at its maximum rate
relative to operating conditions whenever it is feeding. Where an extremely
accurate feeding setting is required, use a calibrated cylinder and a
stopwatch to calculate the amount fed under actual operating conditions. Be
sure to use full timer cycles when making the calculations. See (Section 2
Specifications) and (Section 6 Size Guide) for feed rate details.
CONTINUOUS runs the pump at maximum feed rate regardless of the timer setting.
-Blank page-
Maintenance
5.1 Preventive maintenance is the best defense against possible leaks. Inspect
tubing frequently as stated in safety instructions and lubricate Pinch Tube
often to maintain a coating of silicone grease. Pinch Tube is designed for
minimum service life of 500 hours
pump run time. However Pinch Tube life is affected by many factors such as
system back pressure, environmental temperature, and the chemical being
pumped. Replace the Tube Assembly when found to be deteriorating or at the
start of a new season.
CAUTION! Both inlet and outlet connections may be under pressure.
Depressurize the system prior to connecting or disconnecting the metering
pump.
WARNING! Pump tubing may contain chemicals. Wear protective clothing,
gloves and safety glasses at all times when working on or near the metering
pump.
WARNING! Severe pinching of fingers can occur while installing Pinch Tube
Assembly.
Caution must be used to keep fingers away from rotating parts.
5.2 Pinch Tube Assembly replacement procedure
- See OPERATION section 4.1 to access Pinch Tube Assembly.
- Toggle the MODE Button intermittently between TIMER, OFF and CONTINUOUS settings to move Roller to position as shown in Figure 1 then switch OFF. Roller will rotate clockwise when MODE is set to CONTINUOUS or TIMER.
- Pull lower left end of Pinch Tube Assembly out of inlet port (as noted in Figure 1) and continue to pull away from Roller. Toggle the MODE Button intermittently between TIMER, OFF and CONTINUOUS to move Roller. Keep fingers away from rotating parts. Tube will be released as Roller rotates.
- To install new Pinch Tube, Toggle the MODE Button intermittently between TIMER, OFF and CONTINUOUS positions to move Roller to position as shown in Figure 2 then switch OFF.
- Lubricate Pinch Tube Assembly as noted in OPERATION section 4.1. Lay inlet end (without clamp) in inlet port on left with about ¾” of Pinch Tube protruding from housing. See Figure 2.
- Toggle the MODE Button intermittently between TIMER, OFF and CONTINUOUS positions to rotate Roller assembly while guiding Pinch Tube Assembly into housing as shown in Figures 3 and 4 then switch OFF with roller in position as shown in Figure 4. Keep fingers away from rotating parts.
- With MODE set to OFF, lay Pinch Tube Assembly in outlet port as shown in Figure 5.
- Reassemble housing cover.
5.3 Remove the Pinch Tube Assembly when the pump is not in use. Place the
Pinch Tube Assembly in a clean poly bag when not in use. The pump shipping bag
may be saved for this purpose. A Pinch Tube Assembly under light duty may last
more than one season but replacing the Pinch Tube Assembly may prevent
damaging the pump or an unscheduled maintenance call.
5.4 Crystal buildup is seldom a problem with ROLA-CHEM® pumps. However, it may
be necessary to flush the pump tubing. Use plain water or a weak solution of
muriatic acid (1/2pint muriatic acid to one gallon of water).
WARNING! Always add acid to water. Never add water to acid. (e.g. fill
container with one gallon of water then add 1/2 pint of acid) Wear protective
clothing, gloves and safety glasses.
Additional preventative maintenance may be required in harsh environments.
Strong chemicals and chemical vapors may cause corrosion of metal components.
Inspect pumps for corrosion to exposed metal components.
Chemical Feed Pump Size Guide
WARNING! Failure to use proper size feeder may result in injury.
Pump size must be in compliance with local health codes. When in doubt about
pump size, consult your supplier or ROLA-CHEM®.
NOTE: ORP/pH controllers will not function properly with an over or
under-sized feeder.
Model| Minimum Feed Rate Gallons/24hr| Maxmum Feed Rate Gallons/24hr|
Recommended Volume of Spa Water to be Treated (Gallons)| Recommended Volume of
Pool Water to be Treated (Gallons)| Maximum Volume of Water to be
Treated per California Building
Code Title 24 (Gallons)
---|---|---|---|---|---
RC301| 0.01| 0.90| 500-2,500| 2,500-5,000| 3,000
RC303| 0.12| 12| 2,500-25,000| 5,000-65,000| 40,000
RC305| 0.38| 38| | 65,000-200,000| 127,000
RC307| 0.77| 77| | 180,000-400,000| 257,000
Sizing chart is only a guide and is based on ROLA-CHEM® or equivalent pumps
using 10.5% sodium hypochlorite (chlorine) or 20-32% hydrochloric acid
(muriatic acid). *Consider diluting chemicals for small bodies of water.
Required pump size may vary when diluting chemicals. Size pumps based on
dilution ratio and available pump sizes. Typicaldilution ratios for muriatic
acid range from 4:1 to 9:1. When feeding acid diluted 9:1, the acid pump may
be the same size as the chlorine pump.
WARNING! Always add acid to the water. Never add water to acid. (e.g.
fill tank with four gallons of water then add one gallon of acid) Wear
protective clothing, gloves, and safety glasses.
**RC 305 pumps have been used on pools up to 240,000 gallons. RC 307 pumps
have been used on pools up to 500,000 gallons. Multiple pumps may be used to
meet higher demand requirements.
Heavily used bodies of water may require larger pumps. When using an ORP/pH
controller instead of the timer that is included on the pump, larger pumps may
be required in order to adjust chemistry more quickly.
Troubleshooting Pump Problems
Issue | Cause | Action |
---|---|---|
Pump does not operate, no noise, no motion. | Power | Check power source, |
switches, circuit box, ground fault tripping, etc.
Pump does not cycle on/off when set to TIMER or does not stop when set to
OFF.| Timer| Replace Timer board.
Pump motor turning but no movement in roller assembly.| Motor gearbox| Replace
motor.
Short Pinch Tube life.| Worn or loose components| Replace worn roller assembly
or gearbox assembly and secure pump housing and cover.
Lubrication| Lubricate Pinch Tube more frequently.
High System pressure| Check that system pressure is 30 psi max. (RC307 25 psi
max.).
Discoloration| Tubing discoloration does not affect performance. Tubing can be
replaced if desired.
Pump rotating but not pumping fluid.| Pinch Tube Assembly| Replace Pinch Tube
Assembly.
Roller assembly| Replace roller assembly.
Motor bearings| Replace motor.
Pump motor starts and stops with MODE set to CONTINUOUS.| High temperatures|
Check fan and replace if damaged. Improve ventilation to pump.
Timer| Replace Timer.
Power| Check power source, switches, circuit box, ground fault tripping, etc.
Error Code ‘Er’ displayed.| Reset required| Disconnect power to Pump, then
while holding Up and Down buttons reconnect power and continue to hold both
buttons for 5 seconds. If an error code continues
to appear after resetting contact ROLA-CHEM® service personnel.
Pump Display turns off when operated by an external controller that is not in
feed mode.| Normal condition when controller feed turns off.| To turn Pump
display on, see controller manual regarding activation of feed mode.
Parts List
ITEM| PART No.| DESCRIPTION| | | MODEL|
---|---|---|---|---|---|---
| | | | RC301| RC303| RC305| RC307
1| 543832| ENCLOSURE,FRONT| | X| X| X| X
2| 543833| ENCLOSURE,BACK| | X| X| X| X
3| 8020183| SCREW,#10X3/4,PHPHD,HI-LO| | X| X| X| X
4| 543842| HEAD, BODY,3-ROLLER,GRAY| | | X| X| X
5| 543835| HEAD, COVER,3-ROLLER,GRAY| | | X| X| X
6| 523408| KNOB, LOCK ASSY| | | X| X| X
7| 523400| ROLLER, TRI NS-ASSY (3 ROLLER)| | | X| X| X
8| 525233| SCREW 10-24 x 3/4 PTH SST| | | X| X| X
9| 543843| BODY,HALF,2-ROLLER,GRAY| | X| | |
10| 525004| BRASS STUD 10-32| | X| | |
11| 525140| WING NUT 10-32| | X| | |
12| 523332| ROLLER, 2 INCH H-BLOCK| | X| | |
13| 521058| GEAR MOTOR, 1 RPM, 120V| | 120 V| | |
| 521094| GEAR MOTOR, 1 RPM, 240V| | 240 V| | |
| 521805| GEAR MOTOR, 4 RPM, 120V| | | 120V| |
| 521806| GEAR MOTOR, 4 RPM, 240V| | | 240V| |
| 521316| GEAR MOTOR, 16 RPM, 120V| | | | 120V|
| 521317| GEAR MOTOR, 16 RPM, 240V| | | | 240V|
| 524756| GEAR MOTOR, 30 RPM, 120V| | | | | 120V
| 524755| GEAR MOTOR, 30 RPM, 240V| | | | | 240V
14| 524752| FAN, 2.5 INCH, WHITE, CW| | | | X|
| 524227| FAN, 2.5 INCH, BLACK, CCW| | X| X| | X
15| 543846| TIMER,REPL,KIT,LED| | X| X| X| X
16| 524801| OVERLAY,TIMER,LED/SWITCH| | X| X| X| X
18| 523252| TUBE ASSY-TYGON/VINYL 8 INCH| NOTE A| X| | |
| 523118| TUBE ASSY-TYGON/VINYL 13.5 INCH| NOTE A| | X| X| X
| 523414| TUBE ASSY-NORPRENE/VINYL 8 INCH| NOTE A| X| | |
| 523140| TUBE ASSY-NORPRENE/VINYL 13.5 INCH| NOTE A| | X| X| X
19| 523250| TYGON PINCH TUBE ASSY-8 INCH| NOTE B| X| | |
| 523115| TYGON PINCH TUBE ASSY-13.5 INCH| NOTE B| | X| X| X
| 523251| NORPRENE PINCH TUBE ASSY-8 INCH| NOTE B| X| | |
| 523114| NORPRENE PINCH TUBE ASSY-13.5 INCH| NOTE B| | X| X| X
20| 523102| LUBRICANT, E-Z GLIDE, 3GRAM| | X| X| X| X
21| 525114| CLAMP, HOSE #8 (LARGE)| | X| X| X| X
22| 520111| FITTING, HOSE CONNECTOR, 3/8 BARB| | X| X| X| X
23| 520110| CLAMP, HOSE #6 (SMALL)| | X| X| X| X
24| 520120| TUBING, VINYL .31 x .44 x 66 INCH| | X| X| X| X
| 520116| TUBING, VINYL .31 x .44 x 100 FOOT (OPTIONAL)| | | |
25| 523110| WEIGHT, HOSE 7/16| X| X| X| X
26| 520112| RETAINER-HOSE WEIGHT| X| X| X| X
27| 527158| BRASS INJECTION FITTING, 1/2″ MNPT| X| X| X| X
28| 525113| SEAL, INJECTION FITTING (SPARE)| X| X| X| X
29| 520113| ADAPTER, PP1/4MNPT x 3/8 BARB| X| X| X| X
30| 521170| CHECK VALVE, PVC, 3/8 BARB x 1/4 NPT| X| X| X| X
31| 521160| CHECK VALVE, PVC, 3/8 x 3/8 BARB| X| X| X| X
32| 524155| POWER CORD, 18-3, 120V| PUMP-CORDED,120 V|
| 524156| POWER CORD, 18-3, 240V| PUMP-CORDED,240 V|
33| 524090| STRAIN RELIEF| CORDED PUMPS|
34| 543837| CONDUIT,BODY,LB,1/2″| |
35| 524135| LOCK NUT, STEEL 1/2| CONDUIT MODELS|
36| 524110| NIPPLE, 1/2 x 1| |
37| 525214| GROUND SCREW #8, GREEN| X X X| X
38| 8110030| LOCK WASHER (GROUND SCREW)| X X X|
X
39| 527159| FITTING, INJECTION-8M,NYLON (OPTIONAL)| |
NOTE A : COMPLETE TUBE ASSEMBLY
ITEM 18 INCLUDES: PINCH TUBE ASSEMBLY (ITEM 19) AND ITEMS 23 THRU 27
NOTE B: PINCH TUBE A SSEMBLY
ITEM 19 INCLUDES: TYGON (OR NORPRENE) PINCH TUBE, CLAMP (ITEM 21) AND FITTING
(ITEM 22)
Warranty and Service
Limited Warranty:
ROLA-CHEM® warrants the original purchaser that this unit is free from
manufacturing defects in material and workmanship from the date of the
original purchase for one (1) year.
If this unit fails within the one (1) year period, it will be repaired or
replaced (ROLA-CHEM option) at no charge, when returned to ROLA-CHEM® with
proof of purchase receipt. This warranty does not apply to any product damage
caused by improper use, accident, misuse, improper line voltage, fire, flood,
lightning, earthquake, other acts of nature, or if product was altered or
opened by anyone other than qualified ROLA-CHEM personnel.
All expendable items (tubing, etc.) are not covered under this warranty. ROLA-
CHEM® ® , under no circumstances, shall be liable for any consequential
damages directly or indirectly caused by this unit. Please observe all rules
and regulations required by state and local regulations, building codes,
health codes, OSHA, etc.
Service Procedure: For operation assistance in the United States please
call:
800-549-4473 and ask for Customer
Service, Monday through Friday 8:00 am-5:00 pm Central Time or email: info
@rola-chem.com. Have model number and serial
number available.
ROLA-CHEM® has specialized knowledge and equipment to test and diagnose your
product. Contact our service personnel as noted above for assistance. If you
are directed to ship the product to ROLA-CHEM® and given an RGA#, please note
RGA# on the package and ship freight pre-paid to:
ROLA-CHEM®
5858 Centerville Road St. Paul, MN 55127-6804
www.rola-chem.com
Documents / Resources
|
ROLACHEM RC25 53 Peristaltic
Pump
[pdf] Instruction Manual
RC25 53 Peristaltic Pump, RC25, 53 Peristaltic Pump, Peristaltic Pump, Pump
---|---
|
ROLACHEM RC25 53 Peristaltic
Pump
[pdf] User Manual
RC25 53 Peristaltic Pump, RC25, 53 Peristaltic Pump, Peristaltic Pump, Pump
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>