Weibath Modern Smart One Piece 1.28 GPF Floor Mount Elongated Automatic Toilet and Bidet Instruction Manual
- May 15, 2024
- Weibath
Table of Contents
- Safety Instructions
- Precautions for Use
- Parts Identification
- Installation Guidance
- Installation Steps
- Hose Connection And Installation
- Remote Control Installation
- Trial Run
- Side Control Panel Instruction
- LED Display Screen Instruction
- Automatic Sensing Function
- Fault Judgement And Maintenance
- Daily Maintenance
- Techvnical Support
- List of Materials
- Documents / Resources
Smart Toilet Installation Guide
Intelligent toilet manual precautions for use
Safety Instructions
Please read the safety instructions carefully before using.
The precautions listed here are important in relation to safety and should
always be strictly observed.
The meaning of the diagram is as follows
Caution| It means that if this sign ,s ignored and product handled
improper y. the users Wiii dead or be injured senously.
---|---
Note| It means that if this sign is ignored and product handled improper
y, the users Wiii be injured seriously or subject to property loss.
Examples and descriptions of the Diagram
| It means prohibition.
· The left d.agram indicates
• Disassemb e prohibited”
---|---
| · It means that rt must be observed .
· The left diagram indicates ” stnctly ab;do by “
Caution
Do not spray water or detergent on the main body or electronic plug
- May cause fire or electric shock.
- May cause breakage or damage to the toilet seat or water seepage in the room.
This product belongs to electronic products, please do not install the product in an easily splashed or humid place. Please install an exhaust fan and other exhaust equipment to ensure unobstructed air flow in the bathroom
- Otherwise. it may cause a fire or an electric shock.
Please set the socket for power wiring as follows
- If the wiring is not as follows, it may cause a fire or electric shock.
a. Please use high inductance, fast type leakage switch ( rated induction
current below 1 OmA) or protect with insulated transformer ( above 1.5KVA.
below 3KVA) for the circuit of socket.
b. The installation position of the socket must be more than 0.3m from the
ground and as far away from the bathtub as possible.
The grounded wire equipped with the product must be grounded, please be sure to connect to the ground wire
- Otherwise, it may cause an electric shock.
Note: The grounding treatment mentioned here means that the grounding resistance is below 40 protective earthing, and the grounding wire uses copper wire of 1.6 mm or more in diameter.
When using in the bathroom
Please make sure power supply and the plug is sealed with silicone to prevent
the water
- Otherwise. it may cause a fire or electric shock.
Do not install this product in humid places such as bathroom
- May cause a fire or electric shock.
Never disassemble or repair or modify by yourself
- May cause a fire or electric shock .
Malfunctioning products are forbidden to use
- Under the following circumstances, please unplug the power supply and close the water valve to stop supplying water.
Fautt refers to:
- The main body or water pipe leaks water.
- The product is cracked o, damaged.
- There is abnormal noise or peculiar smell.
- The product smokes and abnormally hot.
- Toilet blockage.
- Fault products are forbidden to use. otherwise, it may cause a fire or electric shock and even indoor water seepage. etc.
Do not use loose or shaking power outlets
- May cause a fire or electric shock.
Water except for tap water and potable water is forbidden to use
- May cause skin inflammation.
It is forbidden to plug or unplug the power supply with wet hands
- May cause an electr c shock.
Do not damage the power cord and toilet connection line
It is forbidden to pull, modify, heat, twist, place heavy objects on the power cord and toilet connection line.
- Damaged products are forbidden to use. otherwise, it may cause a fire or electric shock or short circuit.
Do not use the multi-socket socket
- Please do not connect the wire or use the extens on cord when using. it may lead to heat and cause a fire and electric shock.
Caution
Attention to prevent low temperature burns
-
Please adjust the seat temperature to normal level when siting for a long time.
-
Please adjust the seat temperature to the normal stage, the wind temperature to the low level, when the following people use “thermal seat” and ·warm air drying” functions
-
Children, the elderly, and other users who cannot adjust the appropriate temperature by themselves.
-
People with walking problems such as the sick and disabled.
-
Sleepy people who took medicines. sleeping pills, cold medicines, etc., with sleepy side effects , drank too much, got overtired, etc.
Do not keep cigarettes and other burning stuff nearby
- May lead to a fre.
It is forbidden to put your fingers or sundries at the warm air outlet It is forbidden to touch the warm air outlet with hands or cover it with cloth
- May cause burns. e ectric sbock, fire.
- Please be careful when children and the eldef’ty using
Do not apply force, stand on the seat ring, the flip lid or the main body, and heavy objects are forbidden placed on it
- May cause product 10 crack, the main body to fall apart, the person to be injured.
- Toilet may be damaged and indoor water seepage will occur.
Use diluted kitchen detergent (neutral) to clean. Avoid these products:
(toilet cleaner. detergent, petrol. banana water. cleaning powder and nylon
brushes. etc.)
- May damage and crack the plastic, deforming and cracking it and causing personal injury.
- May damage water pipes and cause water leakage.
When opening the water inlet angle valve, do not remove, or rotate, open the water filter net
- May cause water leak.age.
Do not bend or damage the water filter screen
- May cause water feakage.
Do not flush any sundries except excrement and toilet paper
- May cause the water Closet to be blocked and the sewage will leak out of the room.
Disconnect the power plug for a long time of not using.
Close the water angle valve to stop supplying water when water leaking
Tighten the water filter net when installing
- Otherwise. it may cause water leak.age.
Prevent damage caused by freezing
- May cause damage to the watsr inlet configuration and the interior body, and leakage may OCCUl’S
Please implement warming, to raise the rest room temperature
Make sure the power plug n
- Ensure the power plug is plugged in before using. and the plug and socket fit closely without looseness or Incomplete insertion
- Otherwise, it may cause a fire due to heat.
- Disconnect the power plug for a long time of not using.
When the toilet is blocked, unplug it and use a commercially available pipe unblocker to remove the blockage
- Otherwise, it may lead to sewage leakage and indoor water seepage wtien automatically cleaning.
Do not install it in a place directly exposed to light
- May cause discoloration, aging, and deformation.
Precautions for Use
Cleaning Mistakes
Do not wipe the main body with hard and coarse cloth or tools to avoid
scratching.
Avoid directly waShing with wate,
Daily Maintenance
Avoid splashing urine on the main body or spray nozzle.
Pull out the power plug during the thunder storms.
Improper Operation
Shall not cover the seat sensor, human infrared sensor, and the
transmitting signal and receiving signal of the remote control.
- Maycausethesmarttoiletmisoperation.
Keep away from the main body when using the radio, etc.
- The radio may be garbled
Do Not Lean Back On The Flip Lid
- May cause crack.
Put Away The Child’s Seat Placed On The Seat After Using
- May cause some functions unavailable.
Take anti-freeze measures to prevent freezing damage during the freezing night in winter.
Do not put heaters near the main body.
- May cause discoloration or malfunction.
Do not roughly open the seat ring or flip lid
- May cause crack or malfunction.
Parts Identification
Main Functions
Humanized Functions
Humanized Functions
Installation Guidance
List of Materials
Installation drawings
Caution
Please set the socket as follows
- Ensure the socket property grounded.
- The power cord length is 15m and be located close to the socket, convenient to install and remove, and as far away from the bathtub as possible.
- Use waterproof socket and don’t use extension power cord to connect.
·May cause a fire or electric shock
Size Drawings
Notice before installation
- Test water pressure: more than 1.32 gallons within 15 seconds.
- Before installation, turn on the water pipe for 2 minutes and then connect to the inlet pipe.
Installation Steps
-
For the bathroom newly installing a toilet , a flange with boit shall be added.
Note: You need to purchase your own flange according to the size and position of the two bolt holes at the bottom of the ceramic. See Figure 1 -
Lift the flip lid assembly from the toilet, up from the inside.
Note: Do not pull the lid roughly when lifting the toilet flip lid -
Install a flange under the toilet.
-
Attach the toilet to the flange, making sure the bolts line up with the holes in the toilet (from the top)
-
Use a wrench to lock the nut and other accessories to the retaining bolts. (from the top)
-
To install seat ring and toilet main body the seat ring positioning hole shall be aligned with the ceramic body positioning column. Then in the seat ring’s horizontal state, the hands pressure the back part of the seat ring, so that it can be completely installed.
-
Install the water inlet angle valve and connect the dedicated hose (before connecting the dedicated hose, please discharge water n the hose for 3-5 minutes, ensuring it is clean and that the water inlet angle valve is not blocked)
-
Apply the anti-mold sealant at the contact between the toilet and the ground.After the sealant has solidified, plug in the power supply, slowly open the water inlet angle valve. Adjust the water pressure to within 7.5 kg, and check the sealing of the connection points.
Note
-
Smart toilet accessories have been commissioned. personal disassembly is strictly prohibited.
Please use the fittings and hoses provided by our company.
Old fittings and hoses cannot be reused. If have any questions, please contact local retailers or our after-sales service department. -
All contents of this instruct on manual are based on the latest conditions at the time of printing. We reserve the right to make changes without further notice.
Hose Connection And Installation
- lnstall the new water inlet angle valve, connect the dedicated hose – end to the angle valve, and the other end to the filter housing.
- Plug in the power supply, adjust the angle valve to control the water pressure within 7.5kg.
Note: The hose shall not be folded, otherwise it may cause the water pressure too low to operate the toilet.
Note:
-
ln case of power failure during the cleaning process, please close the angle valve and stop the water supply.
The function can be normal after the self-test when the power comes in. -
lnstallation shall use the new hose assembly that comes with the apparatus and other parts specified in the apparatus. The old hose assembly cannot be reused, otherwise it may cause water leakage.
Remote Control Installation
Installation Method
Note:
-
Clean the installation area before taping. Press the tape firmly and evenly when applying.
Can be used after 15 minutes. -
Double-side tape is suitable for tile-type flat walls, not for wallpaper-type walls.
Trial Run
First time connect water and power supply:
Open the water supply angle valve to turn on lhe power, when soft lighting and
display on the waler temperalure flash, it means the heating water tank s
feeding water.
Waiting for about 30 seconds after soft ighting and the water temperature on
display stops flashing, it means the heating waler tank has been full of
water. At this time, try to operate the toilet as follows.
-
Seating Sensor
The picture shown is the seating sensor area. Only when the system senses someone is seated, the function can be on.
Then. the buzzer will “beep” once. indicating it has been sensed and the system can be activated. When the human body leaves the sensor place, the buzzer will also “beep” once. -
Check Fundamental Functions
When the human body sits on the sensor, the buzzer beeps. Press the “Rear” or “Bidet” button on the side control panel to operate. -
Check the Drying Function
When the human body sits on the sensor, the buzzer beeps.
Press the “Drying” button on the side control panel to operate.
Side Control Panel Instruction
| Press the “Bidet’ button when seated. Press it again lo shift to the mobile
cleaning mode, repeatedly. Press the stop button or leave the seat to stop
this function.
---|---
| Press this button to start the warm air drying function when seated. Press
the stop button and this function will be stopped.
| Long press th s button to tum on/off the entire mode. Short press means
“Stop”, just used to stop current functions.
| Press this button to start rear cleaning. Press it again to shift lo mobile
cleaning. Press the stop button or leave the seat to stop this function.
Press this button to start nozzle self-cleaning when not sealed.
| Press the “Bidet” button when seated. Press it again to shift to the mobile
cleaning mode. repeatedly. Press the stop button or leave the seat to stop
this function.
LED Display Screen Instruction
The top of intellectual toilet, LED display Screen
| indicates water temperature of the nozzle
---|---
| indicates the temperature of the seat
| indicates enerqy-savinq mode, light means on, not light means off
Remote Control Installation
Notice: Remote Control pairing
The remote control pairing method: Long Press the toilet side button[“Bidet™ +
“Stop”] at the same time for 3-5 seconds and it will beep. Press any button on
the remote control and then it will beep, which means pairing successfully.
| Rear
Press tts button to extend the nozzle forward when seated. After the Hip wash
spout spraying for 2 manutes. it will stop spraying automatically. It will
also stop washing if you press the “Stop” button. If you press the “Rear”
button again, the nozzie wilt move back and forth to enter the mobile cleaning
mode. Ounng washing, press the “Pressure +” of “Pressure -” button on the
remote control to adjust the water pressure. The function will stop this when
the human body leaves the seat
---|---
| Bidet
Press this button to extend the nozzle forward when seated. After the Female
cleaning spout spraying for 2 minates, it wil stop spraying automatically. It
will also stop yeashing if you press the “Stop” button. Press.
thes button again while operating. the nozzle will move back and forth to
enter the mobile cleaning mode.
During washing, press the “Pressure +” or “Pressure -” bution on the remote
control to adjust the water Pressure. The function will stop when the human
body leaves the seat.
| Drying
Press this button to start the warm air drying function when seated. It will
stop drying automatically after drying for 3 minutes. It wil algo stop drying
if you press the “Stop” button. Durning drying, press the 4 stages
“normaViow/mediunwhigh’ to adjust the wind temperature. The function wall stop
when the human body leaves the seat
| Massage
The water pressure can be changed in 5 stages allemately and rhythmically.
| Stop
Press this button to stop current operating function. After the user leaves
the seat. the toilet will stop and flush automabcally.
| Flush
Short press thes bution to flush
| Moving Massage
The nozzle can move back and forth in the current posinon to expand the
cleaning area.
| Forward
During washing. press this buiton to move the nozzle forward. which is divided
in 5 stages.
| Backward
During washing. press this button to move the nozzle backward The nazzie can
be adjusted in 5 stages.
| Open Cover
Press this button when not seated. If no other operabon 1s performed afier
opening the Nip lid/seat ring 1.5 minutes (ater, the flip lid/ seat nng will
be automabcally closed.
| Pressure +
Ounng the rear clearang or bidet cleaning funchon, press this button to add
more water. which is divided into 5 stages.
| Pressure –
Ounng the reas clearsng or bidet cleaning furcbon, press this button to
decrease the walter which is divided into 5 stages
Usage Method
| Water Temperature
Short press this button continuously, which is divided into 4 cycle stages:
normal(no heating). low(about 33°C), medium(about 36°C), high(about 40°C).
---|---
| Wind Temperature
Short press this button continuously, which is divided into 4 cycle stages:
normal(no heating). low(about 35°C), medium(about 45°C), high(about 55°C)
| Cover Temperature
Short press this button continuously, which is divided into 4 cycle stages:
normal, low(about 34°C). medium (about 37°C), high(about 40°C)
| Lighting
Press this button to light orvoff.
| Eco
Short press this button to turn on/off. In the “Eco” mode, when the non-
working toilet is on standby state, the seat heating will be off after 48
hours automatically. Otherwise, the seat heating will not be off after 48
hours. (Default is the “Eco” function on)
| Self-Clean
Only when the human body leaves the seat, press this button to start this
operation. The nozzle extends to the maximum and the self-cleaning spout
continues for 15 seconds spraying.
This function can be stopped if you press the “stop” button
Automatic Sensing Function
| Microwave Sensing Flip Lid
When the human body reaches the sensing area, the flip lid will be opened
automatically. If the toilet is opened without operating any function. the
flip lid will be automatically closed in 90 seconds.
---|---
| Foot Sensing
If the foot gets close to the sensing area for the first time, the flip lid
will be opened automatically. For the second time, the seat ring will be
opened. For the third time, the seat ring will be closed and the flip lid can
only be closed by remote contro! instead of the “foot sensing” function. If
the seat ring is opened and no other operation is performed. the seat ring
will be automatically closed after 1.5 minutes.
Advanced Function
| Microwave Sensing
Long press the “Eco” button on the remote control to start the microwave
sensing mode. You can press the ‘Pressure+” or “Pressure-” button on the
remote control to adjust the sensing area by 5 stages. The stage-5 means the
sensing area is the largest and the staqe-t means the smallest sensing area
relatively. The stage-0 means turning off the microwave sensing mode.
---|---
| Off-Seat Flushing
Long press the “massage” button on the remote control to start the off-seat
flushing function. Beeping
for once means tuming on this function. Beeping for 3 times means turning off
this function.
| On/Off
Long press the “stop” button on the side panel control of the toilet.
Note: The drying and cleaning functions cannot be used in the off-seat state.
Remote Control Battery Replacement
When the battery runs out, the remote control maybe insensitive or out of control occasionally. Please replace the alkaline batteries immediately.
Note
The polarity of battery must be put in the right position and the compression spring extends from the negative pole.
- New and old batter es should not be mixed .
- Please use alkaline batteries.
Note: Remote control with batteries. Please appropriately function. Beeping store it in a location that is out of reach of young children.
Backup Battery Replacement
Steps
- Unplug the power outlet.
- Lift the toilet flip lid.
- Open the battery cover.
- Put the battery in the right position.
- Press the “flush” button to ensure appropriate flushing.
- Close the battery cover. Put the flip lid back and fix it.
Note
- The backup battery must be the 9V alkaline batteries. Do not use carbon or other batteries.
- lf the battery is low or not installed, it will cause an abnormal flush. And the flush function will be abnormal even if the power is off.
- Recommend checking the 9V backup battery and replacing it with a new one every two years.
- Please replace the old battery and recycle it appropriately.
Usage Instruction
Water Amount And Temperature
Due to the storage water heating mode, the water temperature will not
decrease when cleaning for a long time. Although the water temperature may
fluctuates, it doesn’t effect the normal use.
Cleaning water will be controlled according to original setting temperature.
Normal: spouting water without heat.
Low: about 33°C
Medium: about 36°C
High: about 40°C
Heating time depends on external water inlet temperature.
Installation with the Seat Sensor
When you are not seated and accidentally press the button, the spout will
not operate due to the seat sensor. All cleaning functions will not be set
when not seated.
The seat sensor will not work if the following conditions occur:
- The human body does not sit on the seat ring.
Environment usage instruction:
It s recommended that there should be no obstacle within 1.Sm of the toilet, otherwise it will cause the flip lid to make wrong instructions.
Fault Judgement And Maintenance
Fault Judgement And Maintenance
Symptom | Inspection Method | Countermeasure |
---|---|---|
Does not start at all | Whether there is a power outage or the power outlet is | |
not connected | Please make sure to insert the power plug |
Please unplug and plug in again
No water supply or weak water spouting| Whether water is stopped or the water
supply valve is closed| Please check the water source and open the water
supply valve
Whether the water supply filter is blocked| Please clean the filter
Whether the nozzle is clogged with scale| Please clean the nozzle with a
toothbrush
| Whether the water pipe is bent| Please smooth the water pipe
Leak| Whether the water pipe connection part is tightened| Please tighten the
water pipe connection
Water temperature/Cool seat| Whether the water temperature and cover
temperature are adjusted to normal temperature| Please readjust the
temperature
Abnormal flushing /the sewage discharging does not work| Put around 2.1
Gal(8L) water into the toilet to check whether the sewage drainage pipe is
blocked| If the sewage in the toilet cannot bedischarged quickly after pouring
water, the sewage drainage pipe may be blocked. Please clean the drainage
pipe.
Remote control cannot display| Low battery power new one| Please replace the
battery with a
Recheck the code| Please refer to page 15 about remote control pairing.
Fault Tip
Fault | Tip |
---|---|
The sensor of cover temperature | The LED display screen shows E7 code |
Remote Fault Diagnosis
Operating through the toilet side button, you can check whether the flushing
function and the trial run work appropriately. (Start the cleaning and drying
function after seated)
Emergency Fault Judgement
Under no water supply circumstance, put around 2.1 Ga1(8L) water into a barrel
and flush the bowl of ceramic.
Note: Avoid water spilling
When the product is left unused for a long time
– Especially in winter when no one at home for a long time, please drain
out the water inside the tank and the pipe to prevent freezing
To Discharge Water
-
Drain out the water inside tank.
– Activate flushing, and then turn off angle valve to prevent water inlet. Drain out the water inside the heating tank and the pipe. -
Unplug and cut off the electricity.
-
Unscrew the hose connector off angle valve, drain the water in the pipe and reinstall.
-
Handle the remaining water in ceramic body.
It is suggested to put some antifreeze into water inside the ceramic body.
Tips: Make sure to turn on water angle valve and power supply when you use
the toilet again.
Note: Before water discharging, the power must be cut off!
Daily Maintenance
Main unit care and maintenance
- Wipe the surface with a sponge or soft damp cloth or neutral detergent cloth.
- Note: Do not use thinners, light gasoline, detergents, chemicals. etc. to wipe. Do not spray insecticides, aromatics, deodorants. etc.
Note: The material of the product is new plastic material, which is not
discolored. Most of the discoloration phenomenon is oxidation reaction.
Product contact with perfume. toilet cleaner, nail polish and other liquids.
if not wiped off in time will cause product surface oxidation.
Some users may place a seat cushion on the seat ring with a heating function.
Generally, the cushion and the contact surface of the seat are non-slip
rubber, once heated. it is easy to cause the seat in contact with the location
to discolor.
Spray nozzle maintenance and care
- .Please clean the nozzle regularly: Prepare a toothbrush and soft cloth first. While not sitting on the unit, short press the “ Rear ” Button on the side of the toilet, the spray nozzle will extend outward and water will flow out to clean the nozzle and the spout.
- Use brush and soft cloth to clean. After cleaning, press the “Stop” button to automatically retract the nozzie.
Maintenance of filter net
- Turn off the water inlet angle valve and use a screwdriver to the left to unscrew the filter net.
- Remove the filter net and use a brush to clean it. Reinstall the filter net into the water inlet angle valve.
- Tighten the filter net and then turn on the angle valve.
Empty the heating water tank to storage water
-
Unplug the power inlet.
-
Turn off the water supply.
-
Lift the toilet body in the direction of the arrow.
-
Lift the bottom of the toilet body and remove the drainage screw to discharge all water.
(Note: do not lose the drainage screw) -
Reinstall the drainage screw on the toilet and ensure to tighten it.
Note: Please refer to the trial run method when using it again.
Techvnical Support
Name | Smart Toilet |
---|---|
Power | AC 110V 50/60Hz |
Cleaning Device | Heating Water Tank |
Inlet Water Temperature | 1’C-30’C |
Inlet Water Pressure | 0 15-0 75MPa |
Warm Water Temperature | Adjustment About 30-C-40-C |
Spray Water
Amount| Rear| About 0 35-1 2L/min (When water pressure is 0 2MPA)
Bidet (female-specific)
Spout Position| Rear| 50mm-90mm
Bidet (female-specific)
Heating Power| 1400W
Safety Equipment| Flow SensoR. Water temperature sensor. Temperature
switch,Thermal fuse
Rated Power| 1300W (inlet water temperature 15′ C ±2 C water pressure 0 2MPa)
Drying Device| Wind Speed| ≥4m/s
Temperature Adjustment| 4 stages (room temperature – about 55′ C)
Heating Power| 250W
Safety Equipment| Thermal controller.Thermal fuse
Seat Heating Device| Temperature Adjustment| 4 stages (room temperature-about
40’0)
Heating Power| 45W
Safety Equipment| Thermal controller.Thermal fuse
Open And Close Device| Seat ring and flip lid with damping cushioning device
Safety Equipment| Leakage protector.The cover temperature sensor
List of Materials
Main Unit
Documents / Resources
|
Weibath Modern Smart One Piece 1.28 GPF Floor Mount Elongated Automatic
Toilet and
Bidet
[pdf] Instruction Manual
Modern Smart One Piece 1.28 GPF Floor Mount Elongated Automatic Toilet and
Bidet, Modern, Smart One Piece 1.28 GPF Floor Mount Elongated Automatic Toilet
and Bidet, Floor Mount Elongated Automatic Toilet and Bidet, Elongated
Automatic Toilet and Bidet, Automatic Toilet and Bidet
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>