Digalox DPM72-MPP Graphical Panel Meter With RGB Backlight User Manual
- May 15, 2024
- Digalox
Table of Contents
- DPM72-MPP Graphical Panel Meter With RGB Backlight
- Safety instructions
- Meaning of symbols
- Intended use
- Description
- Product overview
- Mounting
- Electrical connections
- Configuration
- Other settings
- Maintenance
- Cleaning
- Specification
- Dimensions [mm]
- Contact information
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
DPM72-MPP Graphical Panel Meter With RGB Backlight
User Manual Digalox® DPM72-MPP
Instruction manual (Rev-2023-03)
DPM72-MPP Graphical Panel Meter With RGB Backlight
Graphical panel meter with RGB backlight for analogue signal 0/2 – 10 V and 0/4 – 20 mA
Package contents: Panel meter Digalox® DPM72-MPP, mounting bracket, 5 jumpers, 2 instruction manuals (EN + DE)
Safety instructions
- Read instruction manual carefully before operating the device! Keep for later reference.
- Mounting and installation must be carried out by suitably qualified and competent persons only.
- When working on the device hazardous voltages must not be connected to the device! The terminals J1-J12 are not isolated from the measuring circuit.
- The device must not be used as the only protective device or protective shutdown.
- The device is not intended to protect persons or facilities against harm. Specific devices must be used to guarantee safety (protection relays, cut-off switches, etc.).
- When connecting switches to the terminals J1-J8, only switches must be used whose isolation voltage is at least twice the maximum occurring measurement voltage. For example, when measuring 30 V DC switches must be isolated for at least 60 V.
- Do not open the housing!
- Do not use the device in the presence of explosive or flammable substances!
- All cables carrying hazardous voltages must be secured with external separators.
Meaning of symbols
General warning sign (Attention, observe the documentation!)
Warning of an electrical hazard
Intended use
- Measurement of current and voltage in the specified measuring ranges for process signals
- Indoor use non condensing, non corrosive.
- Panel mounting.
- In operation, supply the device preferably via screw terminals with 12 to 24 V AC/DC instead of via USB.
- Failure to comply with these instructions will void all guarantee and warranty.
Description
The measurement types analogue signal 0/2 to 10 V and 0/4 to 20 mA DC are
supported. The multi display with RGB backlight is able to display up to four
parameters simultaneously. Thresholds can be associated with individual
warning colours. The unit can be switched between display values via an
external switch.
Minimum and maximum values are recorded and can be displayed and reset via
jumper or an external switch. Measured values are recorded over a timespan of
36 seconds up to 14 days. The time base as well as the display of the
measuring history can be switched by an external switch. The measured values
remain stored as long as the device is supplied with voltage.
The following parameters can be adjusted using the configuration software
“Digalox® Manager”: scale endpoint, scale caption, display style (pointer,
tachometer, bar graph, and more), splash image, backlight colour, thresholds
for alarm output, threshold warning colour (light, blink), hysteresis, and
more. Recorded measurement values can be read and a continuous transmission of
the actual measuring value can be enabled. Using the software, values can be
viewed and exported as CSV. Depending on the model, measured values can be
transmitted via USB, XBEE radio technology or RS485 Modbus interface. In
addition, the devices feature a counting function with data retention. This
enables operating-hourscounters or time-counters for exceeding and falling
below threshold values, as well as single pulse counting.
In the “Downloads” area of www.digalox.com you can
find the latest version of the instruction manual and the software “Digalox®
Manager”.
Product overview
| Front
1 Unit or free text
2 Threshold values
3 Upper scale caption
4 Graphical measurement display
5 Digital measurement value
6 Lower scale caption
---|---
| Back
1 2 optocoupler switch outputs
2 Jumper pins J1–J12 for activating/switching of graphical historic data
display, min/max display, auto-scaling, display value (mode), …
3 Supply voltage input
4 Interface (USB Micro-B / XBEE / RS485)
5 Measurement inputs
Mounting
Carefully insert the device into the panel cut-out. Insert the mounting
bracket from the back and push towards the panel until the device sits tight.
Make sure the mounting bracket is snapped into the side of the housing. To
ensure IP65 protection (dust and water jet) when mounting in a front panel,
use optional gasket (separately available).
Electrical connections
Legend
Voltage source, e.g. active sensor or sensor with voltage supply
Current source, e.g. active sensor or sensor with voltage supply
WARNING: The device may only be operated in one of the connection options
shown above! Use an ultra-fast-acting fuse (FF) at the current measurement
input.
If two sensors are used, both must be active. If one sensor is inactive, there
must not be anything connected to the corresponding low measuring input,
otherwise incorrect values will be measured.
Configuration
Connect the device to a computer:
| USB: Connect the device and the computer using a USB cable. The device
driver is installed automatically if the computer is connected to the
Internet.
---|---
| XBEE: Insert the XBEE stick into the computer. The device driver is
installed automatically if the computer is connected to the Internet. In order
to reset the XBEE settings, short-circuit terminal J8.
| RS485: Short-circuit terminal J8. Disconnect the device from the
Modbus network and connect it to the computer using an RS485 USB adapter.
After completing the configuration, open J8 again.
Start the “Digalox® Manager” software and connect it to the device. Settings
can then be made on the various tabs and saved in the device.
After restart, the device always shows the first display value or the one that
is selected by the jumpers J4-J6 (see table “display value”),
in case of a multi display style additionally the following display values.
Table display value (factory preset, can be changed by software)
| Display value| Display| Selection
---|---|---|---
1| 10 V DC scaled| 10 V % J1|
2| 2-10 V DC scaled| 2-10 V %|
3| 20 mA DC scaled| 20 mA %|
4| 4-20 mA DC scaled| 4-20 mA %|
Other settings
The following functions can be activated independently during operation by short-circuiting connectors J1-J3, e.g. using a jumper or switch:
| J1: Graphical
historic data display
The unit displays the stored values within the set time base as a graphical
trend. The time base can be set to days (7, 14), hours (1, 3, 6, 12,
24, 48, 72), minutes (3, 15, 30) or seconds (36).
The time base can be changed by alternately opening and closing J1
(interval < 2 sec). When first opening and closing J1 the current time base is
displayed. For each subsequent opening and closing the time base changes to
the next setting. In order to save the setting permanently, the software
“Digalox® Manager” has to be used.
---|---
| J2: Min-Max display
The display shows the maximum and minimum values recorded since the
last reset. The values can be reset by opening and closing connection J2
shortly (interval < 2 sec). The display shows “Minmax reset”.
| J3: Auto-scaling
The device automatically changes the upper scale caption depending on the
current measuring value, e.g. between 10, 100 and the set upper scale caption.
Maintenance
Periodically check all external cable connections.
Cleaning
Observe the safety instructions before cleaning the device. Clean the device with a dry lint-free soft cloth. Do not use solvents.
Specification
| DPM72-MPP
---|---
Supply| 12 – 24 V AC/DC ±10% (50/60 Hz ±10%) or if applicable via USB,
galvanically isolated
Power consumption| Max. 2.4 W
Display| LCD graphic display 192 x 160 pixels, 16 grey levels with RGB
backlight
Measuring range voltage| ±30 V DC, 20 V AC, 10 – 500 Hz
Accuracy voltage| ±0.5 % true RMS
Internal resistance voltage| 102 kΩ
Measuring range ampere| 20 mA AC/DC (max. 100 mA), 10 – 500 Hz
Accuracy ampere| ±0,5 % true RMS
Internal resistance ampere| 6.2Ω
Measuring value update| 5 Hz (32 kHz sampling rate)
Recording of measurement| 36 seconds to 14 days, 180 internal memory locations
Alarm outputs| 2 optocoupler outputs max. 30 V DC, 50 mA
Permissible voltage between supply and measuring inputs| < 50 V AC, < 75 V DC
Connections (measuring inputs)
– Wire gauge
– Wire strip length
– Pitch| 0.2 – 3.3 mm2 (24 to 12 AWG)
7 – 8 mm
7.62 mm
Connections (supply, alarm outputs and RS485)
– Wire gauge
– Wire strip length
– Pitch| 0.13 – 1.3 mm2 (26 to 16 AWG)
6 – 7 mm
3.5 mm
Operating temperature| 0 °C to +50 °C
Storage temperature| -20 °C to +70 °C
Operating altitude| 0 to 2000 m above sea level
IP code| IP65 (front), ‘P00 (back)
Dimensions| 72 mm x 72 mm x 58 mm
Panel cut-out| 68 mm x 68 mm
Mounting depth| 55.3 mm (with plugs, cable direction rear facing)
72.6 mm (with antenna)
Net weight| 148 g
Dimensions [mm]
Available accessories
TDE Instruments Digalox® DPM72 gasket EPDM/SBR
Contact information
TDE Instruments GmbH, Gewerbestraße 8, D-71144 Steinenbronn
Phone: +49 7157 20801
E-mail: info@tde-instruments.de
Internet: www.tde-instruments.de,
www.digalox.com