ALORAIR Sentinel HD90 Basement and Crawl Space Dehumidifier
Safety Notes
- The Sentinel Series Dehumidifier must always be connected using a grounded electrical connection (as required for all electrical appliances). If non-grounded wiring is used, all liability reverts to the owner and the warranty is voided.
- Sentinel Dehumidifiers should only be maintained and repaired by a qualified technician.
- Sentinel Dehumidifiers are only intended for operation when oriented with the unit sitting on its feet and level. Operating the unit in any other orientation could allow water to flood electrical components.
- Always unplug the dehumidifier before moving.
- If there is a chance that water floods the dehumidifier, it should be opened and allowed to dry thoroughly before reconnecting to electrical power and restarting.
- To ensure proper operation, neither the inlet nor the discharge should be positioned against a wall. The inlet requires a minimum of 6′ clearance and the discharge requires a minimum of 6′ clearance.
- For better use of the dehumidifier, both air inlet and air outlet should be facing the open area of the space.
- Do not insert your fingers or any objects into the inlet or discharge.
- All work on the dehumidifier should be done with the unit “off” and unplugged.
- Do not use water to clean the exterior. To clean the unit, unplug from power, then use a damp cloth to wipe the exterior.
- Do not stand on the machine or use it as a device to hang clothes.
Identification
- For future reference, write down the model, serial number, and date of purchase for your dehumidifier.
- This is extremely helpful if you need to seek assistance in the future.
- The data label on the side of your unit has the key characteristics of your specific unit.
- Model Number: Sentinel HD90
- Serial Number:
- Date of Purchase:
Electrical Supply
- Power Supply: 115 V, 60 Hz AC, Single Phase
- Outlet Requirement: 3-Prong, GFCI
- Circuit Protector: 15 Amp
WARNING: 240 Volts AC may cause serious injury from electric shock.
To reduce the risk of injury:
- Disconnect electrical power before servicing.
- Only plug the unit into a grounded electrical circuit.
- Do not use an extension cord.
- Do not use a plug adapter.
Principle of Operation
- The Sentinel Series Dehumidifiers utilize its integral humidistat to monitor the conditioned space.
- When the relative humidity goes above the selected set point, the dehumidifier will energize. Air is drawn across an evaporator coil, which is cooler than the dew point of air.
- This means moisture will condense out of the air. The air is then reheated through the condenser coil and distributed back into the room.
Installation
The area to be controlled should be sealed with a vapour barrier. If the unit is installed in a crawlspace, all vents should be sealed.
WARNING: Do not install your dehumidifier in a corrosive environment. Some liquid vapour barriers dry via “solvent evaporation”. Always make sure that the barrier is completely dry and the area is thoroughly ventilated before installing a dehumidifier.
- Step #1 : Place the dehumidifier on a level surface.
- If the unit is handled in such a manner that the compressor does not remain in the upright position, you will need to place it on a level surface and wait a minimum of 2 hours before turning the unit “on”.
- NOTE: Do not place directly on the vapour barrier. Elevation is required to allow the condensate water to drain via gravity.
- Step #2: Set Up Drain Line
- The drain line should be routed to a suitable drain on the outside. It must flow down to the drain without any loops, dips, or valleys.
- Recommended Drain Option-Transition to PVC Pipe
- Cut a piece of 3/4″ OD PVC that is approx. 6″ long.
- Insert PVC into a 3/4″ elbow, then attach to a 3/4″ OD length of PVC to drain.
- ( Note: Keep the length of the PVC drain pipe to a minimum).
- Insert the open end of the tubing into the 3/4″ pipe so that it does not extend into the elbow fitting.
- For proper flow, a minimum downward slope of 1″ per 10′ run is required.
- ( Note: If a proper downward angle is not possible, then it is recommended to use a Sentinel HDi90 which includes an integrated condensate pump or utilize an external condensate pump).
- Support the PVC tubing so that it maintains a smooth downward flow to drain.
- Always test the drain before leaving the installation area.
- Step #3: Plug the unit into the 15 amp grounded circuit.
Key Functions
- Power Key
- Use this button to turn the dehumidifier on and off. Press once to turn the machine on.
- You will hear 1 beep and the light will illuminate green.
- Press the power button a second time and you will hear one beep as the machine shuts down.
- Note that there is a one-minute fan delay on shutdown.
- Arrow Buttons
- Use the up and down arrow buttons to set the desired humidity setpoint on the display screen.
- The set point can be any number between 36-90%. Creating a set point means that when the indoor humidity is lower than the set point, the machine will stop automatically.
- Conversely, when the indoor humidity is higher than the set level, the unit will operate.
- NOTE: The humidity levels displayed are approximate only (+/- 5%).
- Continuous Mode
- To switch into continuous mode, set the humidity below 36%. At this point the Cont. light should illuminate green on the display board to indicate you have successfully switched to continuous mode.
- The display screen will show “CO”.
- When set to continuous, the dehumidifier will run constantly, regardless of the humidity level.
- To stop the dehumidifier from running, turn the unit off or switch back to normal humidistat operation. To switch back to normal humidistat operation, simply move the setpoint above 36%.
- Central Control
- This model does not apply to the Sentinel HD90
- The central Control light should be off at all times when not connected to the AC.
- Auxillary Terminals A5/A6
- The A5/A6 on the terminal strip can be used as a water level warning switch for external condensate pumps.
- If an external pump is connected, the pump must have a self-contained power supply and a water level signal line.
Indicator Lights
- Humidity Display Screen
- The display screen has two functions:
- When the unit is powered on, it shows the humidity of the space.
- While setting the desired humidity level, the screen will show the set humidity.
- After a brief delay, the display will revert to the current humidity level.
- Power Indicator Light
- This light indicates that the unit is properly powered on and ready to operate.
- Always make sure this unit is “off” before performing any service.
- When the power light is blinking, it means that the unit has reached the humidity setpoint.
- Continuous Mode/Auto Defrost Light
- When this light illuminates green, it indicates that the dehumidifier is set to continuous operation mode.
- When the light glows red, it means the unit is in auto-defrost mode and clearing the evaporator coil of any ice buildup.
- Compressor Light
- When the compressor light glows red, it indicates the compressor has been initiated but is currently warming up.
- Once the compressor light switches to green, it indicates the compressor is in working status.
Remote Control Instructions
- Sentinel Dehumidifiers can be controlled using an optional remote accessory.
- The Sentinel Remote Control connects to your Sentinel Series Dehumidifier via a 25′ CAT 5 cable.
- The remote control contains an integrated sensor which gives you multiple options for remotely controlling your unit, in addition to monitoring the conditions surrounding the dehumidifier.
- One application for the remote control is to install the dehumidifier in one room with the conditioned air ducted into a second room that contains the remote.
- For example, the dehumidifier could be installed in a laundry room and ducted into a living room.
- The remote would then be mounted in the living room so the remote sensor can control the humidity and provide easy controls for the user.
- Another useful application for the remote control is if the dehumidifier is in an area that’s difficult to access regularly.
- For instance, if your dehumidifier is installed in your crawl space, the remote could be mounted in your living space or garage. This provides you with an easy way to monitor the dehumidifier.
NOTE: Symbols indicated below will only appear when the dehumidifier is powered on.
- On/Off (Power)Button
- Press the on/off button and the machine will start running (one beep). Press the button again to turn the machine off.
- Up Button / Down Button
- Use the Up and Down arrow buttons to adjust the humidity level.
- Mode M
- Use the Mode button to switch between dehumidification and a ducted application.
- The symbol on the display board indicates the sensor on the remote control is being utilized.
- The symbol on the display board indicates the sensor on the dehumidifier is being utilized.
- Temperature T
- Press the temperature button to display the current temperature on the screen. Press the button again to turn off the display.
- Continuous C
- Press this button to switch the unit into continuous mode. Cont. will appear on the display to indicate continuous mode.
- Drain Pump P
- Pressing the drain pump button will remove water from the pump reservoir, so the unit can be safely moved or stored.
- NOTE: THIS FUNCTION IS ONLY AVAILABLE ON THE Sentinel HDi90 MODEL.
Operating Instructions
- Start the machine
- Press the power key to turn the machine on.
- Adjust Settings
- Use the up and down arrow keys to adjust your desired setpoint (typically 50-55%).
- Stop the machine
- Press the power key again and the machine will stop. The fan will continue to operate for 1 minute after the unit has turned off.
- NOTE: Do not disconnect the power cord to force the machine to stop. Always use the power button.
- Water Drainage
- During normal operation, the Sentinel HD90 will automatically drain by the force of gravity.
- If you want to move or store the machine, wait at least 10 minutes to allow the machine to completely defrost, then lean gently towards the drain to ensure the unit is completely drained.
Diagram
Sentinel HD90 Diagram Front View
Maintenance
WARNING: Always unplug the unit before doing any maintenance. Cleaning the machine body Use a soft damp cloth to clean the exterior of the unit. Do not use any soap or solvents.
Cleaning the filter
- Slide out the filter.
- Clean the filter mesh by vacuuming or washing with warm water (no soap or solvents).
- Be sure the filter is completely dry before restarting the unit.
- Be sure the filter is completely dry before restarting the unit.
Coil Maintenance
- Once per year, clean the coils with an approved coil cleaner.
- Coil cleaner should be a self-insing, foaming cleaner such as WEB® Coil Cleaner.
Electrical Access
- Unscrew the 4 screws on the side panel to access the control board.
Dehumidifier Storage
If the unit will be stored for an extended period, complete the following
steps:
- Turn off the unit and allow it to dry.
- Wrap and secure the power cord.
- Cover filter mesh.
- Store in a clean, dry space.
Ducted Applications
- Ducting the dehumidifier allows the unit to be in one room while conditioning an adjacent room.
- The inlet/return collar (optional accessory, PN: W-103) is designed for 12″ flex ducting while the supply grille is designed for 6″ flex ducting.
Be sure to secure the ducting with tie wrap. Also, keep in mind, that the supply ducting can be screwed into an adapter if necessary.
Ducting Installation
- The maximum total length of the duct run is 10′
- Maximum length if only ducting inlet or outlet= 6′
- To connect 12″ return ducting, it may be helpful to:
- Remove the inlet grille from the end cap.
- Connect duct to inlet grille.
- Reconnect the inlet grille to the end cap.
- Note: The supply duct adapter is standard on all units. The return duct collar is an optional accessory.
Removing Duct Adapter
- If it is necessary to remove the adapter, place your hand at the bottom of the adapter and use your fingers to pull it out and down.
- This will remove the cover hooks from the machine.
Installing Duct Adapter
- To install the adapter, line the duct up with holes on the side of the unit pushed up from the base of the adapter.
Flex Duct Installation
- Rotate the flex duct counter-clockwise.
Flex Duct Removal
- Rotate the flex duct clockwise or remove the wire tie.
Troubleshooting
Spare Parts
Limited Warranty
This limited warranty starts from the date of purchase. Alorair Solutions Inc. warrants to the original purchaser that this ALORAIR product is free from manufacturing defects in material or workmanship for the limited warranty period of:
- Six (6) months of parts and labour. This includes the shipment charges for replacement parts or units.
- One (1) year parts and labour. This does not include the shipment charge to send the defective product back to be repaired or replaced.
- Three (3) years of parts and labour on Refrigeration System ONLY (Compressor, Condenser, and evaporator). Transportation costs are not included.
- Five (5) years parts on Refrigeration System ONLY(Compressor, Condenser, and evaporator). Transportation costs are not included.
- This limited warranty is valid only on products purchased from the manufacturer or ALORAIR authorized dealer and operated, installed, and maintained according to the instructions included in this user guide or furnished with the product.
- Alorair Solutions Inc will not provide in-home service during or after the warranty period. You may be responsible for the shipping charge to bring the product to the manufacturer for service.
- To receive warranty service, the purchaser must contact ALORAIR at 888-990-7469 or support@alorair.com.
- A proof of purchase or order number is required to receive warranty service. During the applicable warranty period, a product will be repaired or replaced at the sole option of ALORAIR.
Limited Warranty Exclusions
This limited warranty covers manufacturing defects in materials or workmanship
encountered in normal household, commercial or noncommercial use of this
product and shall not cover the following:
- Damage occurs in uses for which this product was not intended.
- Damage caused by unauthorized modification or alteration of the product.
- Cosmetic damage including scratches, dents, chips, and other damage to the product’s finishes.
- Damage caused by abuse, misuse, pest infestation, accident, fire, floods, or other acts of nature.
- Damage is caused by incorrect electrical line current, voltage, fluctuations, and surges.
- Damage caused by failure to perform proper maintenance of the product.
The use of this product in SPA or a room with an OUTDOOR POOL invalidates or voids the limited warranty.
Warranty Registration
- Comes with lation extensive asian plan.
- To register, simply mil in end retum the warranty card provided in your dehumidifier box.
- Be sure to note your dehumidifier serial number as you will need it for registration.
CONTACT
- AlorAir Solutions INC.
- Add: 14752 Yorba Ct Chino CA 91710 US
- Tel: 1-888-990-7469
- E-mail: sales@alorair.com.
- Specifications are subject to change without notice.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>