popoman A8 Ace Laser Distance Meter User Manual

June 17, 2024
popoman

D:SW-26A
Laser Distance Meters
User Manual

popoman A8 Ace Laser Distance Meter

Read this manual carefully before use and keep it for future reference.

Safety Instructions

All instructions must be read and observed in order for the measuring tool to function safely.
The safeguards integrated into the measuring tool may be compromised if the measuring tool is not used in accordance with these instructions. Never make warning signs on the measuring tool
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE AND INCLUDE THEM WITH THE MEASURING TOOL WHEN TRANSFERRING IT TO A THIRD PARTY.

  • Warning! If operating or adjustment devices other than those specified here are used or other procedures are carried out, this can lead to dangerous exposure to radiation.

  • The measuring tool is delivered with a laser warning sign (marked in the illustration of the measuring tool on the graphics page).

  • If the text of the laser warning label is not in your national language, stick the provided warning label in your national language over it before operating for the first time.
    Do not direct the laser beam at persons or animals and do not stare into the direct or reflected laser beam yourself. You could blind somebody, cause accidents or damage your eyes.

  • If laser radiation hits your eye, you must close your eyes and immediately turn your head away from the beam.

  • Do not make any modifications to the laser equipment.

  • Have the measuring tool serviced only by a qualified specialist using only original replacement parts. This will ensure that the safety of the measuring tool is maintained.

  • Do not let children use the laser measuring tool unsupervised. They could accidentally dazzle someone.

  • Do not use the measuring tool in explosive atmospheres which contain flammable liquids, gases or dust. Sparks may be produced inside the measuring tool, which can ignite dust or fumes.

  • Discarded meter device should not be processed just like household garbage, please handle it in line with related law and regulations.

Product Description and Specations

  1. Type-c charging port;
  2. Display;
  3. Measuring button;
  4. Function button;
  5. Laser beam output;
  6. Reception lens;popoman A8 Ace Laser Distance Meter - Product Description
  7. Battery Supply;
  8. Reference level of measurement;
  9. Measuring functions;
  10. Continuous measurement;
  11. Measurement record;
  12. Current measured value;
  13. Unit of measurement;
  14. Laser warning labelpopoman A8 Ace Laser Distance Meter - Product Description 2

Intended Use

The measuring tool is intended for measuring distances, lengths, heights and clearances,and for calculating areas, volumes and heights.
The measuring tool is suitable for indoor use.

Laser Distance Meters models A8 Ace
Measuring range 0.05-60m
Measuring accuracy ±2mm
Operating temperature 0°C-40°C
Storage temperature -20°C-60°C
Storage Humidity 20%-80%RH
Laser class 2
Laser type 635 nm, < 1 mW
Protection rating IP 54 (dust and splash-proof)
Batteries 3.7V 370mAh
Charging Specification DC 5V >0.5A, Type-C port
Full Charge Measurement Times 8000 times
Dimensions 80x37x20mm

Automatic switch-off after approx.
– Laser| 20s
– Measuring tool (without measurement)| 150s

A) For measurements from the rear edge of the measuring tool, applies to high reflectivity of the target (e.g. a white-painted wall), weak backlighting and 25 °C operating temperature. In addition, a deviation influence of + 0.05 mm/m needs to be taken into account.
B) For measurements from the rear edge of the measuring tool, applies to low reflectivity of the target (e.g. black cardboard), strong backlighting and 0°C to +40 °C operating temperature. In addition, a deviation influence of + 0.15 mm/m_ needs to be taken into account.
C) Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.

Operation

Start-Up

  • Never leave the measuring tool unattended when switched on, and ensure the measuring tool is switched off after use. Others may be dazzled by the laser beam.
  • Protect the measuring tool from moisture and direct sunlight.
  • Do not expose the measuring tool to any extreme temperatures or variations in temperature. For example, do not leave it in a car for extended periods of time. In case of large variations in temperature, allow the measuring tool to adjust to the ambient temperature before putting it into operation. The precision of the measuring tool may be compromised if exposed to extreme temperatures or variations in temperature.
  • Avoid subjecting the measuring tool to violent jolts and falls. Always carry out an accuracy check before continuing work if the measuring tool has been subjected to severe external influences.

Switching On/Off
To switch on the measuring tool and the laser: Under off state, short press Measuring button (3) , device and laser get started simultaneously and the device enters the measurement mode.
To switch off the measuring tool: If no operation is performed within 150s, the instrument will shut down automatically. Or long press Measuring button (3) for more than 3s to turn off it.

  • Do not direct the laser beam at persons or animals and do not stare into the laser beam yourself (even from a distance).

Battery
– The built-in 3.7V 370MmAh lithium battery is non removable. The instrument has its own charging circuit,with clear undervoltage indication and charging indication.
– Battery charging: The charging head should be of good quality and DC5V >0.5 A output. It is recommended to use the mobile phone charging head for charging.
– The instrument shall be charged in time when running out of battery or its battery symbol shows blank and flashes after being turned on due to its insufficient battery capacity.
Insert USB to charge, and the battery symbol scrolls display . When fully charged, it will display  and flash.

Battery Maintenance
Keep it with full power if no operations for a long time and charge it once every half year to avoid the battery damage.
Switching sound on/off
The sound is switched on by default.
Switch the measuring tool off.

  1. Hold down the function button(4) and short press the measuring button(3), then the sound setting mode will appear on the screen (as shown in the figure).
  2. Short press the function button(4) to switch the sound on and off.
  3. Short press the measuring button(3)to exit the setting.

Changing the unit of measurement

  1. Switching on the machine and set the tool in measuring length mode(as shown in the figure).
  2. long press the function button(4) to switch the measurement unit.
  3. Shore press anv button to exit the settina.

| Leanth| Area| Volume
---|---|---|---
1| 0.000m| 0.000m²| 0.000m³
2| 0.00m| 0.00m²| 0.00mm³
3| 0.0in| 0.00ft²| 0.00ft³
4| 01/16in| 0.00ft²| 0.00ft³
5| 0’00” 1/16| 0.00ft²| 0.00ft³
6| 0.00ft| 0.00ft²| 0.00ft³

Unit type
Changing the Reference level of measurement

  1. Switching on the machine and make sure the tool is not in measuring length mode.
  2. long press the function button(4) to switch the Reference level of measurement.
  3. Shore press any button to exit the setting.

Measuring functions

Measuring length
For length measurements, when the measuring tool switching on, repeatedly press the function button (4) until the indicator for length measurement appears ”“—” on the display. To measure, briefly press the measuring button (3).value will be shown at the bottom of the display.
Continuous measurement
In continuous measurement mode, the measuring tool can be moved relative to the target, during which the measured value will be updated approx. every half a second. You can, for example, move the required distance away from the wall while reading off the current distance at all times.
For continuous measurements, in measuring length long press the measuring button (3) for 2 seconds until the indicator for continuous measurement(Max and Min symbol)appears on the display. The laser is switched on and the measurement starts immediately. Move the measuring tool until the required distance is shown at the bottom of the display, Briefly press the measuring button to end continuous measurement.the last measured value will be shown at the bottom of the display.continuous measurement automatically switches off after 150 seconds.
Area Measurement
For surface measurements, repeatedly press the Function button(4) until the indicator for surface measurement appears on the display . and one side of the rectangle flashes. Follow the prompts to complete the measurements:
Press measuring button (3) to measure the first side (length);
Press measuring button (3) to measure the second side (width);
The instrument will automatically calculate the area and the result is displayed on the screen(2)
Perimeter Measurement
For Perimeter measurements, repeatedly press the Function button(4) until the indicator for Perimeter measurement appears on the display .And one of the parallelogram flashes.Follow the prompts to complete the measurements:
Press measuring button (3) to measure the first side (length);
Press measuring button (3) to measure the second side (width);
The instrument will automatically calculate the Perimeter and the result is displayed on the screen(2)
Volume Measurement
For volume measurements, repeatedly press the Function button (4) until the indicator for volume measurement appears on the display and one side of the cubic flashes. Follow the prompts to complete the measurements:
Press measuring button (3) to measure the first side (length);
Press measuring button (3) to measure the second side (width);
Press measuring button (3) to measure the third side (height);
The instrument will automatically calculate the volume and the result is displayed on the screen(2).
Wall Area Measurement
For volume measurements, repeatedly press the Function button (4) until the indicator for wall area measurement appears on the display.Follow the prompts to complete the measurements:
Press measuring button (3) to measure the height of the wall(height);
Press measuring button (3) to measure the length of the first wall;
The instrument automatically calculates the first wall area and displays the result on the screen(2);
If you need to measure the sum of the area of some walls with the same height.
Press the measuring button (3) to enter the n(n=2 or 3 or…) wall measurement and the second length flashes on the screen;
Press measuring button (3) to measure the length of the n(n=2 or 3 or…) wall;
The instrument automatically calculates the sum of all wall areas and displays the result on the screen(2):
Pythagoraspopoman A8 Ace Laser Distance Meter -
Pythagoras There are four Pythagoras modes which is convenient for indirect measurement in a specific complex environment.

  1. Measure the height of right triangle
    repeatedly press the Function button (4) until the indicator for Pythagoras appears on the display and the hypotenuse of triangle flashes. Follow the prompts to complete the measurements:
    Press measuring button (3) to measure the first side a;
    Press measuring button (3) to measure the second side b;
    The instrument will automatically calculate the height of the right triangle x, and the result will be displayed on the display(2).

  2. Measure the hypotenuse of the right triangle
    repeatedly press the Function button(4) until the indicator for Pythagoras appears on the display and the height of right triangle flashes. Follow the prompts to complete the measurements:
    Press measuring button (3) to measure the first side a;
    Press measuring button (3) to measure the second side b;
    The instrument will automatically calculate the height of the right triangle x, and the result will be displayed on the screen(2).

  3. Measure the height of triangular auxiliary lines
    repeatedly press the Function button (4) until the indicator for the height of triangular auxiliary lines appears on the display.and the hypotenuse of the triangle flashes. Follow the prompts to complete the measurements:
    Press measuring button (3) to measure the first side a;
    Press measuring button (3) to measure the second side b:
    Press measuring button (3) to measure the third side c;
    The instrument will automatically calculate the height x of the triangular auxiliary line, and the result will be displayed on the screen.

  4. Measure the third side of a non-right triangle
    repeatedly press the Function button (4) until the indicator for the third side of a non-right triangle   appears on the display.complete the measurement according to the prompts:
    Press measuring button (3) to measure the side a of the triangle;
    Press measuring button (3) to measure the height b of the triangle;
    Press measuring button (3) to measure the other side c of the triangle;

After the measurement, the instrument automatically calculates the third side x of the triangle, and the result is displayed on the screen.
Influences on the Measuring Range
The measuring range depends on the lighting conditions and the reflective properties of the target surface. For better visibility of the laser beam in bright extraneous light, use the laser viewing glasses and the laser target plate or shade the target area.
Influences on the Measurement Result
Due to physical effects, the possibility of inaccurate measurements when measuring various surfaces cannot be excluded. These include:

  • Transparent surfaces
  • Reflective surfaces (e.g. polished metal, glass)
  • Porous surfaces (e.g. insulating materials)
  • Structured surfaces (e.g. roughcast, natural stone).

If necessary, use the laser target plate on these sxurfaces.
Inaccurate measurements are also possible where the laser is pointed at target surfaces diagonally.
Layers of air at different temperatures and indirectly received reflections can also influence the measured value.
Accuracy Check of the Distance Measurement
You can check the accuracy of the measuring tool as follows:

  • Choose a measuring section of approx. 3-10 m in length that is permanently unchanged, the exact length of which is known to you (e.g. room width, door opening). The measurement should be taken under favourable conditions, i.e. the measuring section should be indoors and the target surface for the measurement should be smooth and reflect well.
  • Measure the section ten times in succession.

The deviation of the individual measurements from the mean value must not exceed +5 mm over the entire measuring section in favourable conditions. Record the measurements in order to be able to compare the accuracy at a later date.
Errors – Causes and Corrective Measures

Prompt Cause Solution
Err 1 Signal is too weak Choose the surface with stronger reflection.Use the

reflecting plate.
Err 2| Signal is too strong| Choose the surface with weaker reflection.
Err 3| Low battery voltage| Charge the battery
Err 4| Beyond working temperature| Use the device in thespecified temperature.
Err 5| Pythagoras measuring breaks the rules| Re-measure and ensure that hypotenuse is longer than legs.
Err 6| Out of the measurement range| Use the device within the measurement range

Instrument Maintenance

The meter should not be stored in high temperature and humid environment for a long time. If it is not used very often, please place the meter in the box and store it in cool and dry place.
Please keep the device surface clean. Use a soft wet cloth to wipe the dust on the surface. Do not use corrosive liquid to clean the device. Use the same method as wiping optical devices to wipe the meter and focusing mirror.
Disposal
Measuring tools, battery packs/batteries, accessories and packaging should be sorted for environmentally friendly recycling.
**** Do not dispose of the measuring tools or rechargeable/non-rechargeable — batteries with household waste.
support@popomantools.com
Distributor/Handler:
Shenzhen Allsight E-business Co., Ltd
Address/Adresse:Room 104, Building PO9, South China City Electronic Trading Center, Longgang District, Shenzhen, CHINA
Manufacturer/Hersteller:
Dongguan Sndway Electronic Co.,Ltd
Address/Anschrift: Sndway Science & Technology
Industrial Park,58 Humen Tuanjie Roa Town, Dongguan City,Guangdong Province,China
SCHEUR Technologies GmbH
Hertleinstrasse 37,91052,Erlangen, Germany Emailtec-rep@scheufer.com
Phone/Fax: +4991319402597

popoman A8 Ace Laser Distance Meter - Icon 16Made in China

Documents / Resources

| popoman A8 Ace Laser Distance Meter [pdf] User Manual
A8 Ace Laser Distance Meter, A8, Ace Laser Distance Meter, Laser Distance Meter, Distance Meter, Meter
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals