Zhizun International KUS600 Series Ultrasonic Distance Sensor Instructions

June 17, 2024
Zhizun International

Zhizun International KUS600 Series Ultrasonic Distance Sensor Instructions
Zhizun International KUS600 Series Ultrasonic Distance
Sensor

Features

  • Non-contact measurement
  • PVDF casing forcorrosion environment
  • Low power consumption solution
  • Various output options, wide voltage power supply

Drawings of the sensor

Sensor picture
Drawing of the sensor (unit mm)

Drawing of the sensor

Electrical connections

Cable color PIN No Definition Note
Red 1 Power supply 3.3V~24V
Black 2 GND
Yellow 3 Analogue output Low power version hasn’t analog output
Blue 4 RS485A+
Green 5 RS485B-

Electrical connections

Parameter

General parameters Mechanical Properties
Model No KUS600 Connection
Detection Range1 0.6~5m **** IP grade
Blind zone 0~0.6m,
Ranging resolution 1mm Weight
Measurement accuracy ≤1%F.S Single package
Transducer frequency 220 kHz Single gross weight
Response Time approx. 10 ms
Beam Angle 7°±2
Temp. Compensation inside/outside/fixtemp

Electrical Parameters
Operating Voltage| 3.3~24VDC ripple 10 %SS
Power consumption| ≤ 20mA active period,   ≤0.3mA during sleep time,≤5mA detection status
Circuit Protection| short-circuit protection, overload protection
**** Output| Digital Output| RS485
Analogue Output| 4~20mA/ 0~3.3V/ 0~5V
Switch Output| NPN/PNP
Ambient Environment
Operating Temp.| -25℃-+70℃(-40~85℃, -55~125℃, etc, customizable)
Storage Temperature| -40℃-+85℃

Description of Sensor Functions

Analogue output

Liner output and Program diagrams
Analogue output

The analog output can be set through RS485 interface, the setting procedure is as follows,

Step 1: connect the sensor to the computer through serial port debugging assistant or Modbus debugging assistant.
Step 2: set a near distance point through RS485
Step 3: set a far distance point through RS485
Step 4: set the output voltage or current of the near distance point
Step 5: set the output voltage or current of the far distance point
Step 6: set the analog output to the switch characteristic option
Step 7: set the analog output to a linear output or switch output option
Step 8: reset the sensor to make the new parameters take effect
Description of Sensor Functions

Switch output

There are 8 different functions

  1. Default window mode normally open
  2. Default window mode normally closed
  3. Default single point switch mode normally open
  4. Default single point switch mode normally closed
  5. Default single point hysteresis mode normally open
  6. Default single point hysteresis mode normally closed
  7. Default object detection mode normally open
  8. Default object detection mode normally closed

8 output logic diagrams of switch output
Switch output

Digital output: RS485

Communication protocol is Modus-RTU.
For more information please contact us for the software engineering guide.

Installation conditions

If the sensor is installed at the environment temperature fall below 0℃, it should do well on the protective measures.
In case of direct mounting of the sensor in a through hole using the nuts, it has to be fixed at the middle of the housing thread

Order information

Model No. Output Max range Description
KUS600 Switch output 5m 1.2m connection cable
Analog output 5m 1.2 connection cable
RS485 5m 1.2 connection cable

Contact us

Xi’an Zhizun International Trade CO., Ltd.
Tel: +86-29-87858956
E-mail: contact@top1sensor.com
Getting more info & supports from http://www.top1sensor.com

Tel: 0086-029-87858956
Email: contact@top1sensor.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals