Introduction

The Deactivator DAV-200 deactivates any standard 8.2MHz deactivatable Labels. The Deactivator sends short bursts of approximate 10 μs. After this period the transmitter is switched off and the receiver becomes active. If a non- deactivated Label or Tag is near the deactivator antenna plate an ECHO signal is received and an audible internal Buzzer alarm is given (Option: external Buzzer).
The electronic unit is line-synchronized via the power supply PSD-300.
Modular Concept
The Deactivator consists of:
– Electronic Unit (DAV 200)
-Power Supply
Desktop Antenna Pad or Scanner Antenna (Custom Design).

LUCATRON DAV 200 RF Deactivator - Fig

Connections

LUCATRON DAV 200 RF Deactivator - Fig 1

X1 Power/Synchronization
X2
External Buzzer and Deactivation enable/disable
X3 Connection to PAD/Deactivation coil
LED
will light up when label is detected
Optional connections (X2)

LUCATRON DAV 200 RF Deactivator - Fig 2

Installation Rules

Distances
Observe a minimum of 50cm away from Antenna Pad to:
Electronic Devices:
– Credit card Readers
– Cash Registers
– Computer Systems
– All electronic Devices
All the above devices could lead to malfunctions.
A minimum distance from Antenna Pad to metal parts:
– Side of antenna 4 cm
– Under the antenna 3 cm
Caution: The deactivation height is reduced with metal parts near the Antenna Pad.

Installation Instruction

Mount the Deactivation Pad in, on, or under the counter. Make sure the counter is without any metal part near to the deactivator pad, this could cause a reduction of detection height or self- alarming.
-Fi the Electronic Unit under the counter.
– Connect the Antenna Pad Cable to X3 on the Electronic Unit. A cable longer than 1 meter will reduce the detection height.
– Options: To X2 See Buzzer layout.
-Connect Power Supply (PSD 300) 12 VDC to X1.
– Check for proper function.
– LED will light up if label is detected

LUCATRON DAV 200 RF Deactivator - Fig 3

Pad (OAP 300) Mounting

LUCATRON DAV 200 RF Deactivator - Fig 4

Pad dimensions (OAP 300)

LUCATRON DAV 200 RF Deactivator - Fig 5

Synchronization
The deactivator should always be synchronized in a Checkout Installation.
Power line synchronization is automatically established with the Lucatron Power Supply PSD-300 (default)

LUCATRON DAV 200 RF Deactivator - Fig 6

J7 IN for Line synchronization
JS   not in use

Scanner integration

The Deactivator DAV 200 can be used for scanner integration.
The deactivator has an input to “enable/disable” the deactivation. All “Checkpoint ready” scanners have an output to enable deactivation once a valid barcode is read.
This output will have to be connected to our deactivator and deactivation will only take place if a valid barcode is detected by the scanner.
The use of the input “enable deactivation” is optional. If the input is not connected the deactivator will deactivate any label present, regardless whether a valid barcode was scanned.
“Checkpoint ready” scanners will have the deactivation coil inside the scanner.
The deactivation coil in the scanner need to be connected to our DAV 200.

LUCATRON DAV 200 RF Deactivator - Fig 7

Jumpers setting (factory preset)
All Jumpers pre factory preset. Only when a non-Lucatron pad is connected the “matching” jumpers might have to be changed.

LUCATRON DAV 200 RF Deactivator - Fig 8

Jumper setting:
J1 Factory setting (default is OUT)
J2, J3 & J4, J5 Matching of deactivation coil (for our standard pad DAP 300 no setting is required)
J6 Factory setting (default is OUT)
J7 Power line synchronization active (default IN)
J8 Factory setting (default is OUT)
J9 internal Buzzer (IN – Buzzer ON (default), OUT – Buzzer OFF)

Technical Specifications Deactivator DAV 200

Frequency Range 8.2 MHz
Line Synchronization With Power Supply PSD-300 (default)
Antenna Pad Connector Ph~nix Type “MSTB 2.5/STE” (2 Screws)
RJ12Plug Power Supply+ Line Synchronization
RJ10Plug Disable/ Enable, Alarm
Alarm (no Volume Control) Internal (External Buzzer is optional)
Power 1.5 Win standby mode
Power supply (PSD 300) 100-240VAC I 12 VDC / 1,000 mA
Deactivation Height up to 30 cm*
DAV 200 Dimensions 200 x 57 x 33 mm
Weight including power supply 350 gr (DAV 200)
Certifications CE
  • when 4 x 4cm paper label and standard antennas are used.
    Caution: The use of the Power Supply is only allowed in closed rooms
    Unplug the power supply if unit is not in use
    Don’t use the Power-Supply in the case pins are damaged.
    Repair only from authorized persons
    Regulatory compliance
    This DAV 200complies with European Community regulatory rules for Radio Frequency emissions.
    It has been awarded with the CF mark
    The CF mark is the official marking required by the Furopean Community for all Electric and Floctronic equipment that will be sold, or put into service for the first time, anywhere in the European community. It proves to the buyer and user that this product meets all essential safety and environmental requirements as they are defined in the “European Directives”.
    This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
    However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

    • Reorient or relocate the receiving antenna.
    • Increase the separation between the equipment and receiver.
    • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
    • Consult the dealer or an experienced radio/TV technician for help.

Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

https://manual-hub.com/

Documents / Resources

| LUCATRON DAV-200 RF Deactivator [pdf] Instruction Manual
DAV-200 RF Deactivator, DAV-200, RF Deactivator, Deactivator
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals