LUCATRON DAV-200 RF Deactivator Instruction Manual
- June 17, 2024
- LUCATRON
Table of Contents
Operation Manual
RF Deactivator
DAV200
Introduction
The Deactivator DAV-200 deactivates any standard 8.2MHz deactivatable Labels.
The Deactivator sends short bursts of approximate 10 μs. After this period the
transmitter is switched off and the receiver becomes active. If a non-
deactivated Label or Tag is near the deactivator antenna plate an ECHO signal
is received and an audible internal Buzzer alarm is given (Option: external
Buzzer).
The electronic unit is line-synchronized via the power supply PSD-300.
Modular Concept
The Deactivator consists of:
– Electronic Unit (DAV 200)
-Power Supply
Desktop Antenna Pad or Scanner Antenna (Custom Design).
Connections
X1 Power/Synchronization
X2 External Buzzer and Deactivation enable/disable
X3 Connection to PAD/Deactivation coil
LED will light up when label is detected
Optional connections (X2)
Installation Rules
Distances
Observe a minimum of 50cm away from Antenna Pad to:
Electronic Devices:
– Credit card Readers
– Cash Registers
– Computer Systems
– All electronic Devices
All the above devices could lead to malfunctions.
A minimum distance from Antenna Pad to metal parts:
– Side of antenna 4 cm
– Under the antenna 3 cm
Caution: The deactivation height is reduced with metal parts near the
Antenna Pad.
Installation Instruction
Mount the Deactivation Pad in, on, or under the counter. Make sure the counter
is without any metal part near to the deactivator pad, this could cause a
reduction of detection height or self- alarming.
-Fi the Electronic Unit under the counter.
– Connect the Antenna Pad Cable to X3 on the Electronic Unit. A cable longer
than 1 meter will reduce the detection height.
– Options: To X2 See Buzzer layout.
-Connect Power Supply (PSD 300) 12 VDC to X1.
– Check for proper function.
– LED will light up if label is detected
Pad (OAP 300) Mounting
Pad dimensions (OAP 300)
Synchronization
The deactivator should always be synchronized in a Checkout Installation.
Power line synchronization is automatically established with the Lucatron
Power Supply PSD-300 (default)
J7 IN for Line synchronization
JS not in use
Scanner integration
The Deactivator DAV 200 can be used for scanner integration.
The deactivator has an input to “enable/disable” the deactivation. All
“Checkpoint ready” scanners have an output to enable deactivation once a valid
barcode is read.
This output will have to be connected to our deactivator and deactivation will
only take place if a valid barcode is detected by the scanner.
The use of the input “enable deactivation” is optional. If the input is not
connected the deactivator will deactivate any label present, regardless
whether a valid barcode was scanned.
“Checkpoint ready” scanners will have the deactivation coil inside the
scanner.
The deactivation coil in the scanner need to be connected to our DAV 200.
Jumpers setting (factory preset)
All Jumpers pre factory preset. Only when a non-Lucatron pad is connected the
“matching” jumpers might have to be changed.
Jumper setting:
J1 Factory setting (default is OUT)
J2, J3 & J4, J5 Matching of deactivation coil (for our standard pad DAP 300 no
setting is required)
J6 Factory setting (default is OUT)
J7 Power line synchronization active (default IN)
J8 Factory setting (default is OUT)
J9 internal Buzzer (IN – Buzzer ON (default), OUT – Buzzer OFF)
Technical Specifications Deactivator DAV 200
Frequency Range | 8.2 MHz |
---|---|
Line Synchronization | With Power Supply PSD-300 (default) |
Antenna Pad Connector | Ph~nix Type “MSTB 2.5/STE” (2 Screws) |
RJ12Plug | Power Supply+ Line Synchronization |
RJ10Plug | Disable/ Enable, Alarm |
Alarm (no Volume Control) | Internal (External Buzzer is optional) |
Power | 1.5 Win standby mode |
Power supply (PSD 300) | 100-240VAC I 12 VDC / 1,000 mA |
Deactivation Height | up to 30 cm* |
DAV 200 Dimensions | 200 x 57 x 33 mm |
Weight including power supply | 350 gr (DAV 200) |
Certifications | CE |
-
when 4 x 4cm paper label and standard antennas are used.
Caution: The use of the Power Supply is only allowed in closed rooms
Unplug the power supply if unit is not in use
Don’t use the Power-Supply in the case pins are damaged.
Repair only from authorized persons
Regulatory compliance
This DAV 200complies with European Community regulatory rules for Radio Frequency emissions.
It has been awarded with the CF mark
The CF mark is the official marking required by the Furopean Community for all Electric and Floctronic equipment that will be sold, or put into service for the first time, anywhere in the European community. It proves to the buyer and user that this product meets all essential safety and environmental requirements as they are defined in the “European Directives”.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modifications to this device not explicitly
approved by manufacturer could void your authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. This equipment
complies with FCC radiation exposure limits set forth for an uncontrolled
environment.
This equipment should be installed and operated with minimum distance 20cm
between the radiator & your body.