Specifications

  • Model: 4040
  • L (mm): 1074
  • L1 (mm): 1024
  • D (mm): 102
  • A: NPT(in) 1/2
  • B: NPT(out) 1/4
  • Material: SUS304, SUS316L
  • End cap material: ABS, SUS304, SUS316L
  • Maximum working pressure: 250Psi

Product Usage Instructions

Installation

  1. Select a suitable location for installing the RO membrane housing.
  2. Ensure that the area is clean and free from any obstructions.
  3. Attach the housing securely to a stable surface using appropriate mounting brackets.
  4. Connect the water supply line to the NPT(in) 1/2 port (A) of the housing.
  5. Connect the outlet line to the NPT(out) 1/4 port (B) of the housing.
  6. Make sure all connections are tightened properly to prevent leakage.

Precautions

  • Avoid exposing the RO membrane housing to direct sunlight or extreme temperatures.
  • Regularly inspect the housing for any signs of damage or wear and tear.
  • Do not exceed the maximum working pressure of 250 psi to prevent damage to the housing.
  • Ensure proper maintenance and cleaning of the housing as per the manufacturer’s recommendations.
  • Always shut off the water supply before performing any maintenance or repairs on the housing.

Form parameters and process parameters

RO membrane housings use methods and precautions

  1. When installing the two end caps, please pay attention to the protection of the sealing ring. Lubricant should be applied in place, especially the inner and outer grooves of the end The sealing ring should be evenly applied to ensure that the O-ring is lubricated and pushed forward.
  2. Pay attention to all the fittings at both ends, whether there is any missing installation, and whether there is any debris left in the membrane shell, so as not to damage the filter membrane components and membrane shell.
  3. Check the connecting parts clamps to make sure the installation is in place.
  4. After the installation and inspection are completed, start to slowly add water to the membrane module (inside the membrane housing) to discharge the air inside the membrane element and membrane housing. Discharge Empty and then unpressurized, reciprocate a few times to prevent the water hammer phenomenon, to ensure that the sealing ring stretches freely, reset.
  5. The membrane shell can’t be used as a load-bearing carrier, can’t be used as a load or pressure in the upper part, and can’t exert pressure on the components directly connected with it. The membrane shell should not be used as a load-bearing carrier.

 FAQ

Q: Can I use this RO membrane housing for residential purposes?

A: Yes, the RO membrane housing can be used for residential applications.

Q: What is the recommended maintenance schedule for the housing?

A: It is recommended to clean and maintain the housing every 6-12 months, depending on usage and water quality.

Q: Can I use any type of RO membrane with this housing?

A: The RO membrane housing is compatible with most standard RO membranes. However, it is always recommended to check the specifications and compatibility before installation.