XikeStor 14774 8 Port 2.5G Web Managed Ethernet Switch User Manual
- June 16, 2024
- XikeStor
Table of Contents
XikeStor 14774 8 Port 2.5G Web Managed Ethernet Switch
Production Introduction
- 6 Port, 9 port 2.5G switches front panel is shown in the following figure:
- Indicator
- 26 Port 2.SG switch front panel is shown in the following figure:
- Indicator
- 8 Port lOG switch panel is shown in the following figure:
- Indicator
- 30 Port 2.SG The PoE switch panel is shown in the following figure:
- Indicator
Product Installation
Item List
Installation Safety Precaution
- During installation, please wear an antistatic bracelet or gloves, and keep the switch powered off,to avoid potential safety hazards;
- The switch needs to be at the correct voltage to work properly. Please use the power adapter provided with the switch to power the switch;
- Before powering on the switch, please confirm that it will not cause an overload of the power circuit, so as not to affect the normal operation of the switch or even cause unnecessary damage;
- To reduce the risk of electric shock, do not open the casing when the switch is working;
- Do not place other heavy objects on the switch, and keep the heat dissipation hole of the switch well-ventilated;
- Before cleaning the switch, please turn off the power supply and do not use any liquid to scrub the switch.
Installation Environment Precaution
-
Temperature/ Humidity
To ensure the long-term stable operation of the switch and prolong the service life of the switch, keep the environment at a certain temperature and humidity. Too high or too low humidity may cause electrical leakage and deformation of insulation materials, or even corrosion of metal components. High temperature accelerates the aging process of insulation materials, which seriously affects the service life of switches. Normal operating and storage temperature/humidity are shown in the following table: -
Indoor dust prevention
Dust on the sulface of the switch causes electrostatic adsorption, which prevents metal contacts from contacting properly. Although the switch takes certain measures to preventESD, when the ESD exceeds a certain intensity, it still causes fatal damage to the electronic components on the internal circuit board. To prevent ESD from affecting the normal operation of the device, please note the following:- Regularly remove dust and keep indoor air clean;
- Confirm that the equipment is well grounded to ensure smooth transfer of ESD.
-
Electromagnetic interference
Electromagnetic interference can affect electronic components such as capacitors and inductors inside the device in conductive ways such as capacitive coupling, inductive coupling, and impedance coupling. In order to reduce the adverse effects caused by electromagnetic interference factors, please note the following:- The power supply system shall take necessary measures against interference of the power grid;
- The switch should be faraway from high-frequency high-power, high-current devices, such as wireless transmission stations;
- Take electromagnetic shielding measures if necessary.
-
Surge protection requirements
When a lightning strike occurs, a powerful electrical current is generated for an instant, heating the air in its path to20,000″C, enough to cause fatal damage to electronic device. To achieve a better surge protection effect, please note the following:- Confirm that the equipment ground terminals are in good contact with the ground;
- Confirm that the power socket maintains good contact with the ground;
- Correct wiring to avoid internal induced surge;
- When wiring outdoors, it is recommended to use a signal surge protector.
Desktop Installation
The switch is installed on a horizontal workbench, please note that:
- Confirm that the workbench is stable and firm;
- Maintaingoodindoorventilation;
- The distance between the power socket and the switch shall not exceed 1.2 meters.
Rack Mount
The specific installation steps for installing the switch on a 19-inch
standard rack are as follows:
- Check the grounding and stability of the rack;
- Install the two L-shaped brackets in the accessories on both sides of the switch panel and fix them with the screws provided in the accessories;
- Place the switch in a suitable position within the rack, supported by a bracket;
- Fix the L-shaped bracket on the fixed guide grooves at both ends of the rack with M6 screws to ensure a stable and horizontal installation of the switch on the rack.
Device Connection
Network connections
After powering on, please check the status of the corresponding indicator
light. If the light is on, it indicates that the link is normally connected,
and if the light is off, it indicates that the link is not connected. Please
check the line to confirm that the peer device is enabled. Please refer to the
corresponding panel description for detailed indicator light descriptions.
-
When the electrical port uses 2.5GE speed, it is necessary to use CatsE and above network cables.
-
When using SGE speed at the electrical port, shielded network cables with Cat5E and above specifications are required, and unshielded network cables are not recommended.
-
When using lOGE speed at the electrical port, it is necessary to use shielded network cables with Cat6A and above specifications.
Attention:- When the switch is connected to a workstation, server, router, or other Ethernet device, the network cable length cannot be greater than 100 meters;
- The Auto MDI/MDIX function of the Ethernet port of the switch is enabled by default.; When Category 5 twisted pair cables are used to connect Ethernet, standard network cables or cross network cables can be used;
- Do not connect the RJ45 port to a phone line;
Power connection
- Check that the selected power supply is consistent with the power supply requirements marked on the switch;
- Use the original power adapter or power cord of the switch to connect the switch to the power outlet.
Login Management
- WEB login
Before logging into the management interface of the switch, please set the IP address of the computer and the IP address of the switch in the same network segment. The default IP address for the switch service port is 192.168.10.12 When a computer connects to the switch service port, it is necessary to set the computer IP address to 192.168. 10. x”x” is any value between 1-254, and cannot be 1), and the subnet mask to 255.255.255.0.
1. Connect the device and PC to ensure that the device initialization is complete.
2. Configure the IP address of the PC to be in the same network segment as the default IP address of the switch.
3. Open the browser on the PC and enter it in the address bar https://192.168.10.12 “After pressing Enter, the web management login interface will be displayed. Enter the default user name admin and password admin, and press Enter directly.”
- Local login
1. Use a Console cable to connect the PC to the Console port of the switch.
2. Open the terminal simulation software on the PC, create a new connection, and set the connection port and communication parameters. The communication parameter configuration of the PC terminal should be consistent with the default configuration of the switch console port. The default configuration of the switch console port is as follows:
* **Transmission rate:** 115200
* **Data bits:** 8
* **Verification method:** None
* **Stop bit:** 1
* **Flow control mode:** None
3. Press the Enter key until the simulation terminal displays the following display, prompting the user to enter a username and password. The default user name for the first login is admin and the password is admin.![XikeStor-14774-8-Port-2-5G-Web-Managed-Ethernet-Switch- \(14\)](https://manuals.plus/wp-content/uploads/2024/01/XikeStor-14774-8-Port-2-5G-Web-Managed-Ethernet-Switch-14.png)
Appendix: Technical parameter
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>