PFS Nova Series Reduced Clearance Kit Owner’s Manual
- June 16, 2024
- PFS
Table of Contents
PFS Nova Series Reduced Clearance Kit
Product Information
The Nova Series Reduced Clearance Kit (RCK) is designed to provide lower back wall clearance to combustibles for the Nova Series room heater. This kit is manufactured by MF Fire, Inc. and is intended as a supplement to the respective product Owner’s Manual.
Specifications
- Nova Reduced Clearance Kit (MF02-RCK):
- Nova Series Pipe Shield (0364-000-C)
- Nova Reduced Clearance Air Duct (N92)
- Nova 2 Reduced Clearance Kit (MF03-RCK):
- Nova Series Pipe Shield (0364-000-C)
- Nova 2 Reduced Clearance Air Duct (N93)
Product Usage Instructions
Installation
- Ensure you have the correct Reduced Clearance Kit for your model (Nova or Nova 2).
- Place the pipe shield on top of the stove, centered behind the double wall connector pipe. It should be set back by 1/2 off the back of the double wall pipe. No additional securement is needed.
- Hang the reduced clearance air duct from the two rear air duct bolts already installed on the rear of the stove.
Clearance Requirements
It is important to follow all clearance to combustible requirements to
prevent property damage, bodily injury, or even death. If any portions of the
Nova Series Reduced Clearance Kit are damaged or removed, the stove cannot be
operated unless clearance to combustibles are re-evaluated based on guidance
in the respective product Owner’s Manual.
FAQ
-
What should I do if the pipe shield is damaged or removed?
If the pipe shield is damaged or removed, the stove cannot be operated unless clearance to combustibles are re-evaluated based on guidance in the respective product Owner’s Manual. -
Where should I place the pipe shield?
The pipe shield should be placed atop the stove, centered behind the double wall connector pipe. It must be set back by 1/2 off the back of the double wall pipe. -
How should I hang the reduced clearance air duct?
The reduced clearance air duct should be hung from the two rear air duct bolts already installed on the rear of the stove.
Safety Notice :
Please save these instructions for future reference. Please check our website
for the most up to date version of this manual. Please read this entire manual
before you install and use your new room heater. Failure to follow
instructions may result in property damage, bodily injury, or even death.
Contact local building or fire officials about restrictions and installation
inspection requirements in your area. Do not install Nova Series™ in a mobile
home!
INTRODUCTION
The Nova Series Reduced Clearance Kit is installed to receive lower back wall clearance to combustibles. This Owner’s Manual is intended for use as a supplement to:
- Nova™ and Nova Tower Owner’s Manual
- Nova 2™ and Nova 2 Tower Owner’s Manual
- Nova Bench and Nova 2 Bench Owner’s Manual
DIMENSION
OTHER MODELS
Your Reduced Clearance Kit is comprised of two parts, depending on your model:
- Nova Reduced Clearance Kit (MF02-RCK)
- Nova 2 Reduced Clearance Kit (MF03-RCK)
- Nova Series Pipe Shield (0364-000-C)
- Nova Series Pipe Shield (0364-000-C)
- Nova Reduced Clearance Air Duct (N92)
- Nova 2 Reduced Clearance Air Duct (N93)
PRODUCT OVERVIEW
The pipe shield should be placed atop the stove, centered behind the double
wall connector pipe. It must be set back by 1/2” off the back of the double
wall pipe. No additional securement is needed. If the pipe shield is damaged
or removed, the stove cannot be operated unless clearance to combustibles are
re-evaluated based on guidance in the respective procut Owner’s Manual.
Failure to follow all clearance to combustible requirements may result in
property damage, bodily injury, or even death.
The reduced clearance air duct should be hung from the two rear air duct bolts
already installed on the rear of the stove.