Ruidida R7W Wireless 2D Barcode Scanner Instructions

June 16, 2024
Ruidida

Ruidida R7W Wireless 2D Barcode Scanner Instructions
Ruidida R7W Wireless 2D Barcode Scanner

Dear users, thank you for choosing our products. We will serve you with high- quality products, in order to ensure that you cause this product better, please read this manual carefully before use!

Introduction description

Universal handheld image 2D bar code scanner adopts the international advanced image transmission technology, with two-way communication instant error correction feed back, to complete a variety of commonly used one-dimensional code sand two-dimensional code reading. Equipped with auxiliary illumination,it can be used in different lighting environments and canalsobe used at night, which is highly applicable. 360 ° read barcodesinany direction, faster reading and more efficient operation, commercialization POS systems, supermarkets, warehousing and logistics,books, banking, transportation, postal, and industrial,manufacturing production process management another fields.The setting code preceded with “**” is the default setting, notall functions of the product are listed in this manual, sopleasecontact your supplier for more details. The rights used inthisproduct, including the final interpretation right of this instruction manual are reserved by our Company (The content softhisinstruction manual are modified without notice).

Technical parameters

Battery capacity 2000mAh
Scan barcode category 1D,2D barcode
Code reading density ≥5mil
Types of decoding 1D:EAN13, EAN 8, UPC-A, UPC-E0, UPC-E1,Code128, Code39,

Code93, Interleaved 2 of 5, Industrial 25, Matrix 2 of 5, Code11, CodeBar, MSI, RSS-14, RSS- Ltd, RSS- Exp, Standard 2 of 5, Plessey, ChinaPost 25, GS1 Composite2D:QR Code, Data Matrix (DM), PDF417, Han Xin, Micro PDF417, Micro QRCode, MaxiCode,Aztec Code, Code16K
Operating temperature| Celsius -0°C ~ +50°C
Storage temperature| Celsius -0°C ~ +60°C
Operating humidity| 5%-95% (non-condensing)
Prompt mode| Buzzer, LED
Scan mode| Manual, continuous
Seismic resistance| Pass the 1. 5-meter free fall test

I. Product features

  1. This product adopts CMOS camera module, which can identify 1D/2D code and screen code.

  2. Reading distance up to 20cm, which can quickly read out thein formation in the bar code.

  3. This product is equipped with an inventory function which can directly carry out some simple daily inventory work.
    All parameter settings can be completed by scanning the setting code and save din the memory of the bar code scanner, the inventory content and parameter settings can still be retained after the power if turned off.

  4. This product equipped with one-key pairing function, simple and fast to complete the pairing of transmit/receive (This product has been paired at the factory).

  5. Long distance transmission, 100 meters trans mission distance open area (Indoor transmission distance about 20-30 meter sac cording to different structure and environment).

II. Installation method of receiver

  1. Plug the wireless receiver to the USB port of the computer.
  2. After the wireless receiver is plugged into the computer, thesystem will automatically install the driver (if the driver installationfails, please unplug the receiver or restart the computer).
  3. Once the driver is installed, the receiver can transmit datawiththe paired scanner.

III. Turn on/off the configuration code setting

  • Factory reset

  • The software version

  • Allows all bar codes to be read

IV. Interface settings

  • **USB HID

  • Virtual serial port

V. Commonly terminator setting

  • **CR

  • CR+LF

  • Tab

  • No terminator

VI. Reading mode setting

  • **Key Trigger
  • Auto-Induction

VII. Data output encode format

Users can set the output format of the reading module by scanning the following setting codes, so that the host can output Chinese data according to the specified encoding format.
Note : GbK format is used for Notepad, UNICODE format is used for Word and common chat tool input boxes.

  • **UTF-8

  • Unicode

  • GBK

VIII. Wireless Function Setting

Transmission ModeSetting

  • **Normal mode (Instant data upload)

  • data lossless mode (Instant data upload + Storage mode)

  • Total number of data (Suit for Inventory mode)

  • Inventory Mode(Storage mode)

  • Data Upload.

  • Clear Data(Use with caution)

Note:

  1. Normal Mode: the scan result will be uploaded to the computer in time (Default mode).
  2. Inventory Mode: the scan result will be stored in the internal memory in this mode (when the internal memory is used up, the buzzer will “long beep” as a reminder).
  3. Data lossless mode: the scan results will be upload ed to the computer in time when there has signal; and the scan result will be stored in the internal memory when the signal is weak or no signal, and it will be automatically uploaded to computer when it has signal.
  4. Data Upload :Scan the bar code to upload the data stored in the in tern al memory to the computer in turn (Suit for inventory mode and data lossless mode, please ensure the wireless signal is normal when uploading data, the buzzer will “beep” twice when the data is uploaded successfully, when the data is upload failure, the buzzer will “beep”3 times). 5.
  5. Total number of data:Scanning this bar code will display the total number of stored data (suit for inventory mode).

Clear Data: Scan this bar code to clear all data in the internal memory.

IX. Pairing Parameter Setting

Pairing setting code

  • One-click pairing

Pairing Method

Scan the“One-click pairing”setting code first,plug there ceiver to the USB port of the computer after hear the buzzer “beep”3 times.(Note: After the pairing is successful, the scanner’s buzzer will “beep” 3 times and disappear. Whole step will completed with in 30 seconds.)

X. Sleep time setting

  • SET Sleep time

  • **60 s

  • 5 mins

  • 20 mins

  • 30 s

  • 2 mins

  • 10 mins

  • No sleep time

Note :Scan“Set Sleep time”setting code first, then scan the setting code for the time you want to set.

XI. Language settings

  • **United States

  • Canada

  • Canada

  • Slovakia

  • France

  • Italy

  • Norway

  • Serbia

  • Sweden

  • United Kingdom
    Japanese

  • Belgium

  • Croatia

  • Denmark

  • Germany

  • Latin America

  • Poland
    Slovenia

  • Swiss-French

  • Turkey -F

  • Romanian

  • Brazil

  • Czech Republic

  • Finland

  • Hungary

  • Netherlands

  • Portugal

  • Spain

  • Swiss-German

  • Turkey- Q

XII. Virtual keyboard settings

  • **Standard keyboard

  • Virtual keyboard

XIII. Inverse reading mode

  • Allows inverse reading

  • **Forbid inverse reading

XIV. Battery Indicator

  • Display remaining battery power

XV. Buzzer Prompt Tone

Wireless barcode scanner Buzzer prompt tone list.

Buzzer prompt tone Description
5 times Low battery warning(Pls charge in time)
1 time Normal startup, data upload, setting start/end
2 times Inventory mode data upload completed
3 times No signal, data upload failure

XVI. Fault Resolution

number issue Possible causes solution
1 There is no response after pressing the power on key The scanner is out of
battery Make sure that the host is powered on and is turned on when using the

USB port that is connected to the USB port of the computer board.
The interface cable connected incorrectly| Check if the cable connection is loose
2| There is a fill light, but the barcode cannot be read| This type of barcode code system is not turned on| Turn on the code by reading the setup code
The barcode is damaged| Try scanning other barcodes with the same barcode type
The distance between the scanner and the barcode is not appropriate| Move the barcode scanner closer or farther away from the barcode
The barcode scanner is not high enough to cover the barcode completely| Align the barcode to read the code
3| The scanned data is displayed incorrectly on the host| Input method error| Converts an input method to a standard English input method
Additional settings are made for the scanner| Restore the scanner’s parameters to factory settings or contact the manufacturer’s after-sales service center
4| The barcode characters are garbled or incorrect| The keyboard country setting of the barcode scanner does not match the keyboard country used.| Set the barcode scanner keyboard country to match the country in which the keyboard is used
5| Other cases cannot be decoded| Device transfer error| Turn off the device power, properly connect the device to the scanner, turn on the device power, restore the scanner parameters to the factory setting state andre-scan the code

XVII. Simple maintenance method:

  1. Stains and dust on the scanning window will affect the scanner ‘ s work sometimes. It should use a good quality facial tissue and gently wipe it when cleaning. Then blow it clean with able wing balloon. If you wipe with poor paper for a long time, it will damage the surface finish of the scanning window and affect there a ding effect of the scanner.
  2. The scanner housing can be wiped with a soft clean cloth. If needed, add a small amount of dish soap to the water and wipe it with a soft cloth dipped in water.

FCC Warning:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.
    Caution: Any changes or modifications to this device not explicitly approved by manufacturer
    could void your authority to operate this equipment.
    This device complies with part 15 of the FCC Rules. Operation is subject to the following two
    conditions:
  1. This device may not cause harmful interference, and.
  2. this device must accept any interference received, including interference that may cause undesired operation.

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 0cm between the radiator and your body.