Product Parameters
1. Voltage: 4-30V
2. Current: 0-6.5A
3. Timing: 0-99hours
4. Finction button
5. Direction of current
6. Capacity: 0-999999mAh| 7. Power: 1-195W
8. Resistance: 0-999Q
9. Energy: 0-999999mWh
10. Temperature: 0-80 C
11. Type-C Port Female: Input / Output
12. Type C Port Male: Output / Input
---|---
Functional Instructions
- Click the button once to switch screens in a cyclical manner.
- Double-click the button to rotate the displayed content.
- Press and hold the button (3 seconds): Clear all capacity (mAh), amount of electricity (mWh) and timing.
- The product has power off memory function.
- The product has the function of bidirectional charging measurement.
Calibration Method
- If it is powered by the USB A charger, press and hold the button and then connect the power supply (no need to connect the load), the USB tester will automatically calibrate.
- If it is powered by a PD charger, press and hold the button and then connect the power supply (requires a load to be connected), the USB tester will automatically calibrate.