CHARGING Essentials LA-10A-12C USBA+C Wall Taps
Product Specifications:
- Surge Protection Rating (L-N): 900V
- Joule Rating: 1225 Joules
- Line Voltage: 125VAC
- Maximum Line Current: 15Amp/1875Watts
- Maximum Surge Voltage: 6kV
- Nominal Discharge Current: 3 kA
- 3-wire Grounding Outlets
- USB Charging Ports: Three 5VDC/3.4Amp Total Output
Product Usage Instructions
Charging
Set of 2 USB A+C Wall Taps Instructions:
- Plug the unit into a standard grounded 15A wall receptacle. The unit is not intended for use with 20A or GFCI wall receptacles.
- Make sure electronic equipment is turned off before plugging it into the surge unit outlets.
Surge protection up to 1225 Joules.
A glowing blue indicator light shows that surge protection is being provided. Check the indicator light periodically.
Set of 2 USB A + C Wall Taps Instructions
-
Plug unit into a standard grounded 15A wall receptacle. Unit is not intended for use with 20A or GFCI wall receptacles.
-
Make sure electronic equipment is turned off before plugging it into the surge unit outlets.
-
Surge protection up to 1225 Joules.
-
A glowing blue indicator light shows that surge protection is being provided. Check indicator light periodically (see NOTE).
NOTE:- This device features an internal protection that will disconnect the surge-protective component at the end of its useful life, but will maintain power to the load — now unprotected.
- If the blue “protected” indicator light goes out, this unit will no longer provide surge protection as intended and should be replaced. This device is not a lightning arrestor, so it will not afford protection when lightning strikes nearby, power lines, the house, service entrance or antennas.
-
Rapid charge function includes 3.4-Amp total output up to 17W distributed between all 3 USB ports. For best rapid charging results, utilize the distributed 3.4-Amp total output efficiently. To best utilize the rapid charge function, plug one device into any USB port. Note: USB ports are not designed to charge most laptops or any device requiring more than 17W.
NOTE : USB charging ports may not charge all devices. Some devices
require a proprietary USB power supply.
CAUTION: TO REDUCE THE RISK OF DANGER, UNPLUG ANY AC CORDS AND CHARGING CORDS
WHEN NOT IN USE. HOLD THE TAP STEADY WHEN PLUGGING AND UNPLUGGING AC CORDS AND
CHARGING CORDS AND ENSURE THE WALL TAP IS FLUSH AGAINST THE WALL WHEN IN USE.
Specifications
- Surge Protection Rating (L-N) 900V
- Joule Rating 1225 Joules
- Line Voltage 125VAC
- Maximum Line Current 15 Amp/1875 Watts
- Maximum Surge Voltage 6kV
- Nominal Discharge Current 3 kA
- 3-wire Grounding Outlets 6
- USB Charging Ports Three 5VDC/3.4 Amp Total Output
CONFORMS TO UL STD.498A AND 1449 CERTIFIED TO CSA STD.C22.2 NO.42 AND 269
This product is designed to limit damage to electronic devices from electrical surges of less than 1225 joules. The sensitivity of electronic devices to electrical surges varies, and this product may not protect against electrical surges of greater than 1225 joules, such as from lightning strikes. Please consult the manufacturer of devices plugged into this product and/or a licensed electrician to confirm appropriate protection levels and required number of joules for your product
LIMITED 1 YEAR MANUFACTURER WARRANTY:
ALL CHARGING ESSENTIALS PRODUCTS MUST BE INSTALLED AND USED IN ACCORDANCE WITH THEIR INSTRUCTIONS, INCLUDING INSTRUCTIONS PROVIDED WITH THE CHARGING ESSENTIALS PRODUCT PACKAGING OR PROVIDED ON THE PRODUCT ITSELF. CHARGING ESSENTIALS SURGE SUPPRESSION PRODUCTS WILL NOT PREVENT DAMAGE FROM ALL SURGES, AND SPECIFICALLY ARE NOT DESIGNED OR WARRANTED TO PROTECT AGAINST LIGHTNING STRIKES. CHARGING ESSENTIAL SURGE SUPPRESSION PRODUCTS MUST BE INSTALLED ON A PROPERLY GROUNDED OUTLET WITH A CIRCUIT BREAKER APPROPRIATE FOR ELECTRONIC PRODUCTS, TYPICALLY 15 AMPS. AT THE DISCRETION OF CHARGING ESSENTIALS ANY DEFECTIVE PRODUCT WILL BE REPLACED OR THE PURCHASE PRICE REFUNDED. THIS WARRANTY SHALL IN NO EVENT EXCEED AMOUNTS PAID BY CUSTOMER TO CHARGING ESSENTIALS OR ITS AFFILIATES FOR THE CHARGING ESSENTIAL PRODUCTS INVOLVED, AND EXPRESSLY EXCLUDES COVERAGE OF ANY DAMAGE TO FIXTURES, LAMPS OR THIRD PARTY PRODUCTS OR ELECTRONICS
FCC Statement
This device complies with part 15 of the FCC rules and the Canadian ICES-003.
Operation is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
FCC NOTE: The manufacturer is not responsible for any radio or TV
interference caused by unauthorized modifications to this equipment. Such
modifications could void the user’s authority to operate the equipment. NOTE:
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for helP
Warning
RISK OF ELECTRIC SHOCK
- DO NOT USE IN WET LOCATIONS
- KEEP CHILDREN AWAY
- USE INDOORS ONLY
- FULLY INSERT PLUG
RISK OF FIRE
- DO NOT EXCEED ELECTRICAL RATINGS
- DO NOT USE WITH EXTENSION CORDS
- DO NOT USE WITH POWER STRIPS
PRIOR TO USE, REMOVE THE RAPID CHARGE STICKER ON THE FRONT OF THE WALL TAP
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, USE ONLY INDOORS, UNIT
SHOULD BE PLUGGED INTO AN INTERIOR GROUNDED PARALLEL DUPLEX RECEPTACLE. NOT
FOR USE WITH GROUND-FAULT CIRCUIT-INTERRUPTER RECEPTACLES OR RECEPTACLES WITH
INDICATOR LIGHTS OR CONTROLS. TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO
NOT USE THIS DEVICE WITH A RECEPTACLE IN WHICH THE SLOT OPENINGS DO NOT ALIGN
WITH THE BLADES.
CAUTION: Do not install this device if there is not least 10 meters (30
feet) or more of wire between the electrical outlet and the electrical service
panel. This device features an internal protection that will disconnect the
surge protective component but will maintain power to the load – now
unprotected. If this situation is undesirable for the application, follow the
manufacturer’s instructions for replacing the device. Do Not use with devices
that should not be plugged into an extension cord or operated unattended such
as heaters, burners, etc.
CUSTOMER SERVICE: 1-877-941-2525
M-F 9:00 a.m. – 4:00 p.m. Central time/English, French, Spanish Email: Visit www.cesmarthome.com and click “Contact Us” IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>