MomWills S28 Breast Pump Hands Free Wearable Electric Breast Pump User Manual
- June 15, 2024
- MomWills
Table of Contents
Wearable Electric Breast Pump User Manual
Read this user manual ca electric breast pump and keep this manual for future reference
Remote -Control
Newly Upgraded
IMPORTANT SAFEGUARDS
WARNING
If you are a mother who is infected with Hepatitis B, Hepatitis C, or Human
Immunodeficiency Virus (HIV), pumping breast milk will not reduce or remove
the risk of transmitting the virus to your baby through your breast milk.
Powered breast pumps that are designed for a single user should never be
rented or shared.
Pregnant women should not use the breast pump, as pumping can induce
contractions or premature labor.
The Wearable Breast Pump (528) is not intended to be used during air
transport.
This productis a personal care product
for private use, which should not
be shared with other people. Sharing with others may cause health risks. Also,
the wear-down or breakdown caused by the use of other people is not included
in the warranty.
If the cable or the plug is damaged, soaked in water, or in other situations
that cause them to be unable to operate normally, please do not use this
product.
If you want to clean the pump motor, only wipe it with a clean dry or wet
cloth. Please do not wash it or soak it with water or disinfectant.
Do not use any chemical products to clean the silicone flange, or it may cause
malfunction or health risks.
Please only use the original parts of this pump. Do not modify the parts or
use the parts from other products, or it may cause malfunction.
Besides the parts of this product, do not put any other object into this
product.
Do not use the pump when it is connected to the charger.
Do not put the pump motor in water.
Do not put the pump in the refrigerator or freezer.
Do not store the parts when they are still wet, or it may cause germs or
pollution.
Do not use the microwave to heat breast milk.
If you want to unfreeze the stored breast milk, please let it unfreeze
naturally. Do not pour hot water into the bag or soak the bag in hot water to
unfreeze, or it may go bad or affect the taste.
If the unfrozen breast milk cannot be drunk at one time, please throw it away
instead of putting it back in the refrigerator or freezer.
Please use a new bag to store newly pumped breast milk. Do not put fresh milk
into the bags which have already stored breast milk.
Do not mix fresh breast milk with unfrozen milk for drinking.
PRECAUTIONS
Before each use, visually inspect the individual components for cracks, chips,
tears, discoloration, or deterioration. In the event that damage to the device
is observed, please discontinue use until the parts have been replaced.
If discomfort is felt, then suction can be broken by inserting a finger
between the breast and the flange.
If irritation or discomfort occurs, discontinue use and see a healthcare
provider.
If the USB Type-C charging cable casing or wiring becomes loose, separated, or
frayed, stop using the charging cable immediately and contact the device
manufacturer. Stop using the device immediately if you note any smoke or
burning from the pump unit or charging cable.
Monitor milk level during pumping to ensure overfill does not occur.
If you feel excessive warmth from the 528 Wearable breast pump while pumping,
stop pumping immediately and removing the pump.
Before using, please ensure all the surfaces of the silicone flange, silicone
valve, silicone diaphragm, pump motor, linker, and milk collec- tor are clean.
Before use, please ensure the silicone flange, silicone valve, silicone
diaphragm, pump motor, linker, and milk collector have been assem- bled and
connected well to the pump.
Please check all the parts regularly to ensure there is no wear, tear,
degradation, or deterioration.
If the package is damaged or tampered when it gets to you, please do not open
the package and use the product. Contact our customer service group for an
exchange.
All the parts of this pump are not resistant to high temperature, so please
keep them away from heat sources.
Do not use any flammable products or come near any flammable sourc- es when
you are using or charging this pump.
Do not use this pump when you are lying down, stretching, or doing vigorous
exercise.
Do not use this pump when you are sleeping or sleepy.
Do not wear this pump when you are not breastfeeding.
Do not use this pump when you are driving or operating heavy machin- ery.
The performance of this pump may be affected in high-altitude places, even in
pressurized cabins.
The frequency of communication equipment may affect the perfor- mance of this
pump.
This pump is designed for breast pumping, please use it in strict accor- dance
with the described purpose in this manual.
INTENDED USE
2.1 Indications For Use
The Momwills Wearable Breast Pump S28 is intended to express milk from
lactating women in order to collect breast milk from their breasts.
The device is intended for a single user.
2.2 Contraindication
Do not use this Pump if you have an active implanted device that would be
affected by a magnetic field (e.q., pacemaker, implantable cardio- verter
defibrillator).
2.3 Operating Life
The expected operating life of the washable parts is three months. It is
recommended to replace the washable parts after long-time storage or before
pumping for your next child.
PRODUCT DESCRIPTION
3.1 Parts
- 24mm Flange
- Pump Motor
- Silicone Diaphragm
- UsB Charging Cable
- Remote Controller
- Milk Collector
- Bra Adjustment Buckle
- Vale
- 19/21mm Flange Plug
Other Accessories Included:
Storage Bag Nursing Bra Extender
Cleaning Brush Quick Start Guide Milk Storage Bag Flange Size Card
3.2 Controller
Buttons | Function |
---|---|
Long-press and hold to turn on/off Short-press to select massage/expression |
mode
| Increase suction strength
| Decrease suction strength
| Blue light indicates massage mode Red light indicates expression mode
Buttons| Battery status indicator displayed| Remaining pump time
left
---|---|---
| The battery indicator is solid green || No less than 120 minutes
| The battery indicator is flashing red| No more than 20 minutes
3.3 Remote Controller
- Mode switching button
- Control left breast pump
- Control right breast pump
- Massage mode
- Expression mode
- Level down display
- Level up display
- Level/Time display
- Time/Minute
- power display Red/Green light
- On/Off button o Left/Right switch button
Buttons | Function |
---|---|
short-press to select control of the L/R breast pump. When L/R is selected, |
long press to turn ON/OFF
M| Mode selection
_| Decrease suction strength
+| Increase suction strength
| Massage Mode: In this mode, the breast pump begins with a quick and short
sucking pattern to get your milk to start flowing.
| Expression Mode: The breast pump begins with a more deeply and more slowly.
slow sucking pattern for milk expression, sucking
| Suction Level Display: The breast pump has 9 suction levels to choose from.
| Running Time Display
| Remote controller battery display
Battery Level Indicator
| Green light s on, the power is sufficient. Red light is on, the power is
low.
---|---
| In Charging: When the pump is charged, the power indicator flashes red
light.
| Fully Charged: The power indicator green light is stay on.
Note: It is only used as a reminder light for whether there is power, the
symbol does not represent the amount of power.
3.4 Remote Control Matching
– Long-press the On/Off button ” ” to turn on the breast pump.
– Long-press the buttons “+” and “-” at the same time until the LED flashes.
The breast pump enters the matching state.
– Keep the remote
controller within 1 meter of the matching breast pump.
– Short press the on/off button “ ” of the remote controller, select the
breast pump “ ” or “ ” you want.
– Long press the remote controller button “ ” , the display of the remote
controller will turn on.
– Long-press the buttons “+” and “-” at the same time on the remote controller
until appears “0P” become “P” on the display screen, indicating successful
matching.
– Repeat the above actions to match the other side of the breast pump.
CAUTIONS
- Remote will sleep after 1 min idle.
- The control buttons on the left/right side of the remote controller can control two breast pumps, enabling them to start and operate simultane- ously. (Match twice with “R”, or twice with “L”)
- The left and right buttons on the remote controller can operate separate breast pumps. Pressing one button starts and runs only the corresponding pump, without affecting the other (When matching, use “R” to match one breast pump and “L” to match another breast pump).
GETTING STARTED
CAUTIONS
Make sure that you clean the pump as instructed in this user manual.
Make sure that you assemble the pump correctly as instructed in this user
manual.
To avoid leakage, remove the residue around the rim before assembling.
Wash your hands thoroughly before you assemble cleaned components.
41 Select Flange Size
This pump only includes a 24mm silicone flange and 21mm, 19mm flange plug
inserts. If the flange provided does not fit, you can find a 27 mm flange and
flange inserts of 17mm, 15mm, and 13mm are available to purchase on Amazon.
Type “momwills” in the search bar and find the flange size and flange insert
that fits you.
Flange Size Chart
Nipple Measurement(mm) | 13-15 | 16-17 | 18-19 | 20-22 | 23-25 |
---|---|---|---|---|---|
Flange(mm) | 17 | 19 | 2 | 24 | 27 |
4.1.1 Stimulate The Nipple
- Stimulate your nipple to get a full size (do not skip this step!).
- Place the nipple into the smallest hole you can comfortably fit into without forcing it.
- Select the hole that can comfortably fit the very base of your nipple.
- Get your measurement based on the size chart.
4.1.2 Test The Flange Fit
- To find the suitable flange size, first, you need to make sure you place the flange in the right place on your breast.
- Please press the flange on your breast until there is no gap. Make sure your nipple is right in the middle of the flange.
Too small: During pumping, if your nipple continues to rub against the
inner wall of the flange, then this flange is too small for you.
Good Fit: During pumping, if your nipple moves smoothly without rubbing
or touching the inner wall of the flange, and almost no areola is sucked
inside, then this flange is right for you.
Too large: During pumping, if a large area of areola is sucked inside,
then this flange is too big for you.
4.2 Get The Right Bra
- Made of stretchy fabric
- No underwire or padding
- Has aflap
- Full coverage
4.3 Recommended Posture
CAUTIONS
Always sit or stand upright while pumping to prevent the milk from leaking.
This pump is not be used when lying down or sleeping to ensure proper
orientation is maintained during use. ) Breastfeeding sitting position
Relax and sit in a comfortable chair, lean slightly forward (use acushion for
back support). Make sure to keep the breast pump and breast cup upright.
POSTURE
Make sure the pump and the milk collector always stay at the vertical angle.
Otherwise, the milk will spill out.
PUMPING
5.1 Assembly
Before using, please ensure all parts are installed correctly.
- Wash your hands thoroughly with soap and water.
- Install the valve to the milk collector, paying attention to the direction of installation.
- put the silicone diaphragm into the milk collector, and press it with your hands ‘to make the edges fasten tightly to ensure a perfect seal.
- Connect the flange with the main body. Make sure that the flange fits securely around the rim by pressing it down with your thumbs.
- Install the main body of the breast pump on the milk collector, align the notch under the main body with the silicone diaphragm, and assemble it downward tofit the milk collector to ensure a complete seal.
5.2 Alignment
- In the process of pumping, please make sure the pump is pressed tightly.
- To align, hold the flange against to your breast so you can see whether your nipple is centered in the flange tunnel or not. You may need to bend forward.
- After you’ve aligned, look through the flange to confirm your nipple is centered before connecting the pump. The tip of your nipple should not touch the top, sides or bottom of the flange tunnel. If it does, try again.
IMPORTANT:
-
Correct nipple alignment is key to comfort expression and performance.
-
Nipple must be positioned correctly in Flange Tunnel before pumping to avoid discomfort.
-
See Section 4.1. GETTING STARTED-Select Flange Size.
5.3 Secure Pump In Bra- Adjust the bra strap, one end of the bra adjustment buckle hung on the inside buckle of nursing bra. The length of the bra buckle on the other end of the bra adjustment buckle.
- Secure pump in place by bra, taking care to keep pump pressed firmly against breast. If necessary, tighten bra to keep pump securely in place and start pumping.
- Adjust the bra strap, one end of the bra adjustment buckle hung on the inside buckle of nursing bra. The length of the bra buckle on the other end of the bra adjustment buckle.
5.4 Turn On Pump
Do not slide pump directly into your bra, follow step-by-step instructions.
Disconnect from Charger before use.
Consult your healthcare practitioner to understand how long you should pump.
Momuills pump turns off automatically after 20 minutes.
Long press the On / Off / Pause button to turn on or turn off the pump.
Tip: Momwills pump gets warm during running. Don’t worry! This is normal.
5.5 Vacuum Pressure Settings
Momuwills pump has 9 vacuum pressure settings for each mode, giving you
control over what feels comfortable and works most efficiently in both
stimula- tion and expression modes.
Once you can feel the vacuum pressure on your nipple, use the Increase/De-
crease button to adjust vacuum pressure to find your preferred setting in both
modes. The remote controller LED display will be off after no operation for 20
seconds, press any button can activate the LED display.
Tip: A higher vacuum pressure does not always mean a higher volume of
milk. Putting your nipple under excessive stress can reduce milk production.
Always ensure you are pumping at a comfortable level. If you don’t feel
suction, please check the pump is assembled correctly (see section 5
PUMPING-5.1 Assembly).
Precautions
- Momwills pump does not support use while charging. Always disconnect from the charger and close the charging cap before use.
- Momwills pump should not be used while lying down, engaging in strenuous activities or performing activities with risk of harm.
- Using a breast pump should not cause pain. Do not try to express with a vacuum pressure setting that is too high or uncomfortable. If excessive discomfort or pain is felt during pumping, stop pumping, break the seal around your nipple and discontinue the session.
FINISHING PUMP
6.1 Turn Off Pump
When you finished expressing, long press the power button to turn off.
6.2 Remove the Breast Pump
Break the seal between the breast and the pump funnel with your finger, and
use your finger to break the seal between the flange and the breast tissue.
Keep the milk collector vertical when removing the pump, then keep the flange
opening side up to prevent milk from pouring over.
Tip: We recommend the user to stop the pumping session once the expressed
milk volume of the milk collector approaches 120 ml to avoid overflow.
6.3 Collect the Milk
Collect breast milk with a sterilized container or special breast milk storage
bags. Make sure the slot feature aligned with the bottle.
6.4 Charging
-
Full charge takes about 120 minutes.
- When the battery is low, the battery indicator will turn red;
- When charging, the battery indicator flashes red;
- When itis about to be fully charged, the battery indicator flashes green;
- The battery indicator will be steady green when the battery is fully charged.
IMPORTANT: Pump will not operate while plugged into the electrical
outlet.
ONLY USE standard adaptor with USB Type-C cable for charging.
CLEANING, TRANSFER ANDSTORAGE
7.1Cleaning
IMPORTANT: Pump will not operate while plugged into the electrical
outlet.
ONLY USE standard adaptor with USB Type-C cable for charging.
7.CLEANING, TRANSFER ANDSTORAGE
7.1Cleaning
7.1.1Disassemble
- Separate pump motor from main body.
- Detach flange from milk collector.
- Separate linker from milk collector.
- Disassemble the linker.
7.1.2 Cleaning
- For best sterilization, please clean and disinfect the pump before the first use.
*Itis a non-sterile product. Before cleaning and disinfection, please remove all accessories.
Supplies needed
– Mild dish soap
– Clean dishcloth or soft brush
– Clean wash basin
– Clean water
Washable parts:
Milk Collector, Flange Diaphragm, Linker, Valve
- 24mm Flange
- silicone Diaphragm
- vale
- 19/21mm Flange Plug
Non-washable parts:
- Pump Motor
- UsB Charging Cable
- Rremote Controller
Warning: Breast pumps are personal care items intended for a single user only and should never be rented or shared. Separate and wash all parts that come in contact with breast and breast milk immediately after use to avoid breast milk residue and prevent bacteria growth.
-
Rinse all separated parts that come into contact with the breast and breast milk with water at a temperature between 25-30°C (77-86°F) in order to remove any breast milk residue.
-
Once rinsed, parts that have touched the breast or breast milk should be placed in a clean wash basin used only for washing infant feeding equipment.
– Soak all washable parts in 40-60 °C (104-140 °F), soapy water for 3~5 minutes.
– Wash each part with a clean dishcloth or soft brush.
– Rinse all separated parts with clear water. -
Place parts on a clean surface or towel.
– Allow all parts to air dry.
– Store dry parts in a clean, cool place when not in use.
– Do not store wet or damp parts.
Caution: Only use drinking-quality water for cleaning.
Sanitize – Before first use and once per day
-
For best sterilization, please clean and disinfect the pump before the first use.
*Breast pump components that contact the breast and breast milk (flange, milk collector, linker, diaphragm, valve) can be hand-washed in the sink.
Precaution:
The pump body which houses the electrical components should be wiped down with a low-level disinfectant such as ethyl alcohol o isopropyl alcohol (70%-90%).
Supplies Needed:- Clean pot for 100 °C (212 °F) water
- Clean water,Tongs
- Washable part to wash:
- Flange
- Linker
- Diaphragm
- Valve
Warning: Breast pumps are personal care items intended for a single user only and should never be rented or shared. Separate and wash all parts that come in contact with breast and breast milk immediately after using to avoid breast milk residue and prevent bacteria growth.
-
Wash hands thoroughly.
-
Fill a pot with enough water to cover all parts.
. Bring water to a boil. -
Allow water to cool and gently remove parts from water with tongs.
-
Place parts on a clean surface and / or towel.
« Allow all parts to air dry.
«Store dry parts in a clean, cool place when not in use.
« Do not store wet or damp parts.
7.2 Transfer
- When traveling, please use the charging cable provided and adjust it to the right power source for your current location. Before boarding the plane, please consult the airline for advice about carrying or using this pump on the plane first.
- Temperature: -20 to 60 °C / -4 to 140 °F
- Relative Humidity: 15% – 90%
- Ambient Pressure: 90 to 106kPa
7.3 storage
7.3.1 Pump Storage
HOW TO STORE THE PUMP
-
Temperature: -20 to 60°C / -4 to 140 °F
-
Relative Humidity: 15% to 90%
-
Short-term storage: Before the next breast pumping, please keep the pump away from direct sunlight, and ensure that the washable parts are dry and away from children. If the battery indicator displays red, please charge the pump immediately.
-
Long-term storage: First, please charge the pump before long-term storage in which way the service life of this pump can be prolonged. Second, keep itin a place away from direct sunlight in avoidance of discoloration. Third, clean and dry the washable parts before storing them. When you want to reuse it again after a long time, please charge it first before reusing.
HOW TO STORE BREAST MILK
CAUTIONS
These guidelines are only for healthy and full-term babies. If your baby is premature or suffering from sickness, please consult with your health care provider for other guidelines.- Use breast milk storage bags or clean, food-grade containers to store expressed breast milk. Make sure the containers are made of glass or plastic and have tight-fitting lids.
- Remove air before sealing.
- Lay bags flat to freeze. To prevent sticking between bags, please separate the bags with paper towels.
7.3.2 Milk Storage
Type of Breast Milk | Storage Locations and Temperatures |
---|---|
Freshly Expressed or Pumped | Countertop 77 °F (25°C ) or colder (room |
temperature) | Refrigerator 40 °F (4°C ) |
3 months
Thawed, previously frozen| Within 2-4 Hours| Within 2-4 Hours| Within 3 months
Use within 2 hours after the baby is finished feeding
These guidelines are for healthy full-term babies only and may vary for
premature or sick babies. Check with your health care provider.
7.4 Disposal
DISPOSAL METHOD
- This pump contains a rechargeable lithium-ion battery. For disposal, please assort this pump to designated recycling stations for electrical equipment waste in your country.
- Proper disposal of this pump helps to protect natural resources, human health, and the environment.
- For more information about designated recycling stations, please contact the relevant departments in your area.
TROUBLESHOOTING
Problems | Solutions |
---|---|
Milk does not flow | Pause the pump and remove it from breast. Realign it |
correctly.(Refer to Section 5 – PUMPING – Alignment). = You may also separate
the pump from the flange to realign (Refer to Section 7- CLEANING, TRANSFER
AND STORAGE-DISASSEMBLE). Then, center your nipple in the flange tunnel and
bring the pump to your breast (Refer to Section
5. PUMPING-Alignment).
Need to realign| Pause the pump and remove it from breast. Realign it
correctly, (Refer to Section 5 – PUMPING -Alignment).
«You may also separate the Pump from the Flange to realign (Refer to Section
7- CLEANING, TRANSFER AND STORAGE-DISASSEMBLE).Then, center your nipple in the
flange tunnel and bring the pump to your breast (Refer to Section 5. PUMPING –
Alignment).
Feel discom- fort while pumping| «If you’re experiencing excessive discomfort,
please try the following (Refer to Section 5. PUMPING – Alignment):
« Make sure to press the Momwills pump firmly against breast during
Stimulation phase.
+Tighten bra to make sure the Momwills pump. is held firmly against the
breast.
« Decrease suction strength.
– Realign the Momwills pump (see above).
« You may be pumping for too long. Momwills pump shuts off automatically after
20 minutes.
– You may not have the correct flange size(Refer to Section 4. GETTING STARTED
— Select Flange Size). Stop and see a medical professional or breastfeeding
specialist.
3§z)eaif”” socton| The Pump has 9 suction settings. Press the increase button
to increase suction strength. D437
Stop pumping| «Pump stops pumping automatically after 20 minutes.
Pump does not stop pumping| « Long-press the On/Off button.
«If the issue persists, then break the seal by inserting a finger between the
breast tissue and the flange. Then Press the On / Off / Pause button to turn
the pump off.
Pump or Charger gets wet (immersed in water).| « Dry the pump off immediately.
Prop Pump upright with charger port down and suction controls up, and let it
air dry overnight. Do not
use the pump or charger within 24 hours.
« Contact Customer Care.
Pump is not charging.| Ensure the USB Type-C cable with standard charge (not
included) i fully plugged into the pump charging port. D443
SPECIFICATIONS
Pump Dimensions: | 129mm X 114mm X 67mm |
---|---|
Pump Weight: | 2369 per unit |
Vacuum Range (Expression): | 140mmHg-280mmHg |
Charging Time: | 2.5 hours |
Usage Time: | 80 – 90 minutes |
Rated Input: | 5V1A |
EMC GUIDANCE
Warning: Don’t use near active HF surgical equipment and the RF shielded
room of an ME system for magnetic resonance imaging, where the intensity of EM
disturbances is high.
Warning: Use of this equipment adjacent to or stacked with other
equipment should be avoided because it could result in improper operation. If
such use is necessary, this equipment and the other equipment should be
observed to verify that they are operating normally.
Warning: Use of accessories, transducers, and cables other than those
specified or provided by the manufacturer of this equipment could result in
increased electromagnetic emissions or decreased electromagnetic immunity of
this equipment and result in improper operation.
Warning: Portable RF communications equipment (including peripherals such
as antenna cables and external antennas) should be used no closer than 12 in
(30 cm) to any part of the equipment, including cables specified by the
manufacturer Otherwise, degradation of the performance of this equipment could
result.
ELECTROMAGNETIC EMISSIONS Guidance and manufacturer’s declaration declaration
– electromagnetic emissions
Emissions test | Compliance |
---|---|
RF emissions CISPR 11 | Grounp 1 |
RF emissions CIsPR 11 | ClassB |
RF emissions CISPR 11 | ClassB |
Harmonic emissionse | Not applicable |
Voltage fluctuations/ flicker emissions IEC 61000 | Not applicable |
Guidance and manufacturer’s declaration -electromagnetic Immunit y
Immunity Test | IEC 60601 Test level | Compliance level |
---|---|---|
Electrostatic discharge (ESD) IEC 61000-4-2 | 8 kV contact |
2kV, 24k,
48KV, 215 kv D619| 8 kV contact
22k, £4 kv,
8KV, £15 kV F626
Electrical fast transient/burst IEC 61000-4-4| Not applicable| Not applicable
surge 1EC £1000-4-5| Notapplicable| Not applicable
Voltage dips, short interruptions and voltage variations on power supply input
lines IEC 61000-4-11| Not applicable| Not applicable
Power frequency magnetic field 1EC 61000-4-8| 30A/m 50Hz/60Hz| 30A/m 50Hz/60Hz
Condued RF 1606100046| Not applicable| Not applicable
Radiated RF IEC61000-4-3| 10V/m 80MHz-2,7 GHz 80%AMatHz || 10v/m 80 MHz-2,7
GHz 80 %AM atHz
NOTE UT is the a.c. mains voltage prior to application of the test level.
SYMBOLS ON THEDEVICE
| His symbol indicates to follow instructions for use.
---|---
| This symbolindicates the manufacturer .
| This symbol indicates do not dispose the device together with unsorted
municipal waste (for EU only).
| This symbol indicates a type BF applied part.
IP22| This symbol indicates the degree of IP protection.
| This symbol indicates the date of manufacture (four digits for the yearand
two digits for the month )
| This symbol indicates manufacture’s serial number of the device.
| This symbol indicates direct curren.
FCC COMPLIANCE
Any Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Note:
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interfer- ence to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radiio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
– Consult the dealer or an experienced radio / TV technician for help.
Manufacturer Company
Name:
Shenzhen TPH Technology Co. , Ltd
Address: sth Floor, Building NO. 29 East side ,Lianchuang 2nd technology
park Bulan Road,
Nanwan Community, Longgang District, Shenzhen, China
MADE IN CHINA
Documents / Resources
|
MomWills S28 Breast Pump Hands Free Wearable Electric Breast
Pump
[pdf] User Manual
S28 Breast Pump Hands Free Wearable Electric Breast Pump, S28, Breast Pump
Hands Free Wearable Electric Breast Pump, Wearable Electric Breast Pump,
Electric Breast Pump, Breast Pump
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>