Refresh P02 Wireless Electronic Thermometer User Manual
- June 15, 2024
- Refresh
Table of Contents
**Refresh P02 Wireless Electronic Thermometer User Manual
**
Dear users, thank you for choosing our company’s electronic thermometer (RIT-P02-MED、RIT-P02-RR、 RIT-P02-RS、RIT-P02-MM and RIT-P02-R1). In order to better understand this product and correct use, please read this instruction carefully and keep it properly.
Statement】
- Shenzhen Refresh Bioventing Technology Co., Ltd. (hereinafter referred to as Refresh) owns the intellectual property rights of this manual and its corresponding products. Without the written permission of Refresh, no individual or organization may copy, modify or translate this manual.
- Refresh may upgrade the product due to some requirements, and the accompanying manual will also be upgraded. Any change to this manual is subject to no prior notice, please understand.
- Before using this product, medical institutions, doctors or patients should carefully read all the contents of this manual. If you need detailed understanding, please contact after-sales service.
- The picture may be different from the physical appearance, please refer to the actual.
[Date of compilation or revision of the manual] The first version c this
manual is V6.0, and the compilation date is August 2022
[Software release version number] V2
[Software type] Application software [Expiry date] 3 years
[Production date] See on package label ICMIIT ID| See the product nameplate
for the model approval coc standard of this product
Medical device registration certificate No. Guangdong Machinery
Standard 20202070453
[Technical requirements for medical devices No.| Guangdong
Machinery Standard 20202070453
Executive standard| YY 0785-2010 Clinical thermometer
Performance requirements for electronic thermometers for
continuous measurement
[Name of registrant, manufacturer and after-sales service unit] Shenzhen
Refresh Bioventing Technology Co., Ltd.
[Address of registrant] Room 902, Building 1, Hengtaiyu Building, Tangney
Community, Fenghuang Street, Gunging District,Shenzhen, Guangdong, P.R.
China[Production address] Room 401, No. 1001, Longkang Avenue (Ping Section),
Pingxi Community, Pingxi Street, Longing District, Shenzhen [Production
license No.] YSYJX Production License No. 20224699
Product introduction
Product introduction
This product is a wearable intelligent temperature detection device. It uses the temperature sensor at the bottom of the device to measure the temperature quickly and accurately. The thermometer is small in size, skin-friendly on the bottom, portable and convenient. It can be worn continuously for 24 hours to monitor body temperature.
Product features
- Comfortable wearing: small size, skin-friendly design;
- Continuous monitoring: 24-hour continuous monitoring;
- Over temperature alarm: If the body temperature exceeds the high temperature prompt value set by APP, APP will remind;
- Economical and convenient: button cell can be replaced and the electronic thermometer can be used repeatedly;
- Report sharing: automatically generate test report, which can be sent to WeChat;
Product name and model
Model | Structure | Color |
---|---|---|
RIT-P02-MED | Bear-look | Blue |
RIT-P02-RR | Circle-look | White |
RIT-P02-RS | Square design with rounded corners | White |
RIT-P02-MM | Droplet design | White |
Structure and components
This product is composed of device, button cell, medical adhesive and mobile terminal application software.
Application
- Applicable to the continuous measurement of body temperature.
- Applicable to monitoring the body temperature of all people.
- Use location: Under the armpit.
Expected service environment
It is applicable to the continuous measurement of human body temperature by families or medical institutions. The environmental requirements are as follows:
Environment | Working environment | Storage and transport |
---|---|---|
Temperature | +5°C – +40°C | -25°C – +55°C |
Humidity | 10%RH – 83%RH | 10%RH – 93%RH |
Atmospheric pressure | 70kPa – 106kPa | 50kPa -106kPa |
Note : Please store or use within the specified temperature and humidity range, otherwise the electronhermometer may not achieve the claimed performance.
Technical parameter
Powe’ supply mode | Internal power |
---|---|
Safety type | type BF for aoolication part |
Loncellspec–Otto | CR1225 button cell |
Voltage | c.c.3V |
Terrioeraire range | 25.0°C – /5.0°C |
Measure-nen:error | ±0.2°C (25.0°C – 45.0°C) |
Nolan risoluto | 0.1°C |
Pansinissioi :force | 10m(ri oper,without wall place) |
Temperature unit | Celsius(t) |
Waterproof level | IP22 |
Network sec-Illy | Operating environment |
or pad. RAM : Not less than 512MB; ROM: Not less tan 5121 B; CPU: NC less than
1.0GHz
Software environment: Android 5.0 and above ; .0S9.0 and above; Harmony 2.0
and above.
Network conditions: no restrictions
It taw euro:(vrtumistetze| Bluetooth BLE More that 42
User Access Control| Accocnt+oassnot; Mobile phone number yen:cat–on code;
Vieta’s author: zed loci
Contraindications
- People with damaged or inflamed skin are prohibited.
Precautions, warnings and notes Safety precautions
- Do not disassemble the product except to install or replace the button cell.
- Do not use in places with strong electromagnetics, since the Bluetooth signal transmission may be interfered.
- Before and after the measurement, it is recommended to use medical alcohol to wipe the temperature sensing parts and body parts of the electronic thermometer for disinfection.
- After each use, please put the electronic thermometer into a clean storage box and keep it in a dry and ventilated place.
- Please do not place the electronic thermometer directly in water or other liquids for cleaning.
- The adhesive tape and button battery of this product are consumables, please replace them in time.
- Medical adhesive is a disposable consumable material. It is only used by one person. It should not be applied to many people to avoid cross infection.
- Medical adhesive has great stickiness. Make sure there is no hair on the adhesive site before pasting.
- Continuous body temperature measurements should be conducted regularly. Due to sweating at the measuring part, the adhesive loses its stickiness. Please replace the adhesive in time.
- When the adhesive is torn off the skin, please tear it carefully and slowly to prevent the skin or pore injury caused by the strong stickiness of the adhesive.
- The effective wireless transmission distance of host in accessible environment is 10 meters. Human tissues will affect the transmission of wireless signals. When placed in the axillary temperature measurement, the effective transmission range of signals will be reduced.
- All illustrations provided in this manual are for reference only. The illustrations may not be completely consistent with your product.
- Do not use electronic thermometer for a period of time, please take out the batteries in the thermometer.
Warnings
- In order to offer a maximum comfort for children to wear and use, we design the device with maximum system integration. Because of its small size, please use it safely and avoid children swallow it accidentally. Children under 6 years can only use it by the help of their parents.
- Please keep this product out of the reach of pets and young children to avoid swallowing it by mistake.
- Due to personal physical differences, people with sensitive skin may have itching or swelling symptoms during pasting. In this case, adhesive stickers should be avoided. If the itch will subside after the use of adhesive, the symptoms should be stopped in time
- For continuous body temperature measurement, the measuring part should be checked regularly to observe whether the skin is red and swollen or has other discomfort. In case of skin discomfort stop ursi immediately, and get medical attention in time in case of serious condition.
- Do not monitor the same skin position for more than 8 hours, because the adhesive may be contaminated after long-term use. At this time, it is necessary to move the position and replace the adhesive beforeeasuring.
- Before using the electronic thermometer every time, it should be disinfected to prevent cross infection among multiple people.
- to avoid polluting the environment. Put the products and button batteries out of the reach of children and out of the reach of pets to avoid the risk of accidental swallowing. If the thermometer or button is swallowed, please send it to the hospital for treatment immediately.
- The test results cannot be used for self-diagnosis. Self-diagnosis and treatment is dangerous and you should follow the doctor’s diagnosis.
- If you have a fever for a long time, go to the hospital as soon as possible.
- This electronic thermometer is only used to measure the temperature of the armpit in human body, do not use it to measure other parts (such as forehead, mouth, ears).
- Do not use this product in the environment of flammable anesthetic gases. Because the temperature measurement results are affected by many factors, the temperature readings obtained by this device are only for reference.
- Do not put this product into the fire, its internal battery and other components may explode in the fire.
- Read carefully and follow the instructions to ensure that the product can work normally for a long time and the temperature readings are accurate.
- The temperature monitoring function can not be used to prompt the temperature after the temperature is set. In addition, set the prompt function and do not adjust the prompt volume to an inaudible volume.
- The performance of the electronic thermometer may fail or degrade after reaching the service life. Please do not continue to use it.
- Do not use this product to measure the temperature beyond the range
Packing list
Name | Company | Quality | Name | Company | Quantity |
---|
Electronic
thermometer| Platform| 1| An irstructicii
manual| Book| I
Storage box| Individual| 1| Adhesive
sticker| Slice| Z.)
Bt.tton battery| Pieces| 2| Protective sleeve
(optional)| Individual| 3
L’d opening tool| Individual| 1| SCIVCC card ‘circinate 0* conformity)| Book|
1
Symbols and description
\yrnbol | • Description J | Symbol | Description |
---|---|---|---|
Notice, Check the | |||
random filesIIlo | Reference instruction | ||
Type BF for | |||
application part | Bluetooth device | ||
Do not discard at will |
(recycle according to
local requirements)| | Non-ionizing radiation
lP22| Dustproof grade is 2, waterproof grade is 2| | The service life is
3 years
Chapter 2 Application
Software download
- The Android and Harmony user download the client software, which can be downloaded through the application market, or scan the QR code below to download directly.
- iOS users can also search “Liipoo Care” in the app store and click to download it.
After downloading APP, You can log in in the following ways:
- Mobile phone number verification code;
- WeChat authorized login;
- Account name and password. The next operation can only be carried out after you login; You can set your personal information in “My” – “Account Information”.
Devices that software supports
- Android devices: run Android 5.0 and higher level systems and support android devices with Bluetooth 4.2.
- Harmony Equipment:run Harmony 2.0 and higher level systems and support Harmony devices with Bluetooth 4.2.
- Apple devices: run IOS 9.0 and higher level systems and support apple devices with Bluetooth 4.2.
- Update: select whether to update the version of the mobile terminal according to the notification prompt of the mobile terminal;
- Uninstall: operate according to the user’s mobile terminal attributes;
- System capacity: according to the user’s mobile terminal attribute;
- Data synchronization: when the same account is logged in on different devices, the data will be synchronized automatically.
Note :
- The equipment can only be connected to one mobile terminal at the same time;
- Please keep your account and password, and do not disclose it to others to prevent theft.
Software usage restrictions
- For sensitive information such as data import and export, mute, user setting and system setting, password authorization is required.
- It is only applicable to the electronic thermometer produced by Shenzhen Refresh Biosensing Technology Co., Ltd.
- The operation shall be carried out after carefully reading this manual.
- Functions that users can call: login function, setting function, search device function, measurement function, temperature reminder function, event recording function and log function.
Launch app】
Open Bluetooth and start the “Liipoo Care” app. If the app is not installed, download it according to thins ructions in 2.1.
Power on】
Take out the electronic thermometer from the storage box, the indicator light will be on for a long time, and the equipment will start automatically. See Figure 2 for the schematic diagram. If the light does not flash, the battery is not installed or the battery is dead. Refer to replacing the battery.
Cleaning】
Before use, please disinfect the surface of the electronic thermometer. See 2.7 for details of cleaning an disinfection.
【 Operation 】
Step 1 : On the top right of the temperature measurement home page, Click the button: > Add device, bind and connect the target thermometer, and wait for a few seconds to obtain the current measurement data.
Note: There are three ways to connect the thermometer. You can choose to scan and bind, receive the SN code on the input product label, or automatically connect to the thermometer nearest to the mobile terminal through Bluetooth.
【Replace the electronic thermometer】
If it is necessary to replace the display electronic thermometer, click the button on the top right of the temperature measurement home page: …> Delete device and delete the thermometer to be replaced. Then bind and connect the target thermometer according to step 1 and then you can use the newly connected electronic thermometer for measurement.
Put the electronic thermometer into the storage box, take out the indicator light for a long time after 3 seconds, and the device will start automatically.
Take out the adhesive tape of the storage box and tear off the square backing paper first.
Remove the annular backing paper after pasting.
Figure 2. Schematic Diagram of Electronic Thermometer
.
Step 2:
Take a piece of adhesive and stick it to the side of the electronic thermometer with temperature sensor, and then stick the electronic thermometer to the underarm, as shown in Figure 2. If there is sweat or dirt under the armpit, please wipe it clean before adhering. After the electronic thermometer is placed successfully, keep the arm clamped or cover the measuring part with clothes. The data displayed at the beginning of the measurement is not current temperature data. You need to keep the temperature measurement position for 5-10 minutes before readinlectronic thermometers can continuously measure body temperature and refresh it every 3 seconds.
Step 3:
Remove the electronic thermometer from the measuring position, tear off the adhesive on the back of the device, and clean the shell. Put it into the storage box, and the device will automatically enter the sleep state, and place it in a cool place for storage.
Note: Please put the thermometer in the storage box in time to avoid battery power consumption.
【Other function operations】
- Temperature reminder function: under the temperature measurement status, click “High temperatuinder”, and then click the number in the box, where you can set the temperature reminder you need (the setting range is 30.0°C~ 45.0 °C). Note: If the temperature reminder function is required, please do not turn off the “reminder switch”, or you will not receive the reminder information.
- • Event recording function: under the temperature measurement status, click “Data Report” to enter the data report interface and browse down. You can add event records, select the recording time, then select “Vigor”, “Appetite” and “Cooling”, or edit and record in “Note”.
Log function: click the calendar button on the top right of the data report to view the past measurement records and event records
. Precautions for use of electronic thermometer
- The equipment shall not be used in the environment with strong electromagnetic interference;
- The equipment must be cleaned and disinfected after each use or before each use;
- There may be measurement deviation after the equipment exceeds its service life (3 years);
- • The button battery and adhesive shall be discarded in accordance with local regulations.
- Description of indicator light: the indicator light will be on for one time when the machine startsutomatically; The con- nection with the mobile terminal is successful, and the indicator flashes continuously for 3 times; Automatic shutdown flashes once.
- The posture and physical condition of the measurer will affect the temperature measurement. Before using the equipment for measurement, please ensure that you have had a full rest; If you have just finisheercising, please have a rest for at least 30 minutes; When measuring the body temperature, please try to keep your arms clamped, and do not expose the thermometer to the air; If it is not convenient to maintain, please cover your clothes to ensure that the temperature at the measuring location is as close to the body temperature as possible.
- When measuring the body temperature, the thermometer needs to be placed under the armpit for 5~10 minutes before reading, so as to make the displayed temperature consistent with the body balancmperature.
- The body temperature you measured should be explained or diagnosed by a professional (doctor). Please do not self diagnose.
Button cell replacement
- Use the cover opening tool to pry along the groove on the electronic thermometer, and open the cover upward;
- Press the edge of the battery with your fingernail, the battery will pop out automatically, and the positive pole will face up to install a new button battery;
- Close the cover (the cover has no direction), check the circumference of the cover, and ensure that the cover is seamed.
Pry off the groove part.
Press your finger on the edge of the button cell and the it pops up
Cleaning and sterilization
- Cleaning: If there is dirt on the device or temperature sensing parts, use a small amount of water or neutral cleaner on a clean soft cloth and wring it dry before wiping. Do not use acidic or alkaline cleaners.
- Sterilization:Before and after use, wipe the temperature sensing parts and device with a small amount of 75% medical alcohol with a clean soft cloth. Let it dry naturally.(Note: please do not put the electronic thermometer into the liquid to clean or sterilize it. Prevent the liquid flow into the electronic thermometer.)
Chapter 3 Maintenance and troubleshooting
Maintenance and service
After use, put the electronic thermometer in a clean storage box and keep it
in a ventilated, dry and dust-free place. When using it, try to prevent the
electronic thermometer from falling or forceful collision, so as not to damage
the internal devices.
Do not use acetone, gasoline and other strong solvent for cleaning.
Troubleshooting
Situations | Possible causes | Solutions |
---|
The rear light
does no: flash
where the
device is
taken ou:
from the
storage oxo
and cannot
be corrected| A. Button cell ‘s out of power| A, Replace new button cell with
the same type(type: CR1225)
B. No button cell is i ‘,stalled| B, Install new button cell with
thesame type (type: CR1225)
C. Wong polarity of button cell| C. Load the bu:ton cell according to the
correct polarity
the device is
Laken
out from the
storage oox
and
cannot oe
connected| A. Bluetooth is not :vned on| A. turn on blue:ooth
B. It is too far from the equip-nen or the signal is blocked by obstacles|
Betaken tie ozone concerted near to the device
C. The equipment is occupied during the operation| C. Apply for authorization
or reset the device
No data
transmits to
the APP| The device stops work.ng or disconnects| Artur of. the APP and
restart, or close the device and restart. 1• A cannot be solved and lie Olson
cell power is normal, lease contact the customer service.
If the above faults cannot be solved according to the solutions, please contact the after-sales service unit to provide services.
Chapter 4 Electromagnetic compatibility
Electromagnetic compatibility statement
-
Notice :
Wireless electronic thermometer (RIT-P02-MED, RIT-P02-RR, RIT-P02-RS, RIT-P02-MM) meets the electromagnetic compatibility requirements of YY0505-2012 standard;
The user shall install and use according to the electromagnetic compatibility information provided in the accompanying
documents;
Portable and mobile RF communication equipment may affect the performance of electronic thermometer, so strong electromagnetic interference shall be avoided when using, such as near mobile phones and microwave ovens;
The guidelines and manufacturer’s statement are detailed in the annex. -
Warning : The wireless electronic thermometer (RIT-P02-MED, RIT-P02-RR, RIT-P02-RS, RIT-P02-MM) should not be close to or stacked with other equipment. If it must be close to or stacked for use, it shall be observed and verified that it can operate normally in its used configuration; Except for the cables sold by the manufacturer of this product as spare parts of internal components, the use of accessories and Cables outside the regulations may lead to an increase in the emission of this product. Even if other equipment meets the emission requirements of corresponding national standards, the equipment may still be Interfered by other equipment. The operating frequency of electronic thermometer Bluetooth receiving and transmitting is 2.402GHz-2.480GHz ISM band, the channel bandwidth is 2MHz, and frequency hopping technology is adopted. IN GFSK modulation mode, the transmission power is 0 dbm (typical) of the maximum transmission power of CLASS2.
Gude anc manufacturer’s slaternent – Electromagnetic emission
Electronic thermometer (RIT-PO2-MED, RIT-PO2-RR、RIT-PO2-RS.
RIT-P02-MM、RIT-P02-R1) is intended to be used in the electromagnetic
environment. specie below. The purchaser or user of the device shall ensure
thal it is used in such an electromagnetic environment.
[mission test| Conformity| Electromagnetic environment – gu’ce
Rocio-frequency emission GB4824| Group| internal functions of the device. As a
result, it has very low radio-frequency emission and ‘s unlikely to interfere
with nearby electronic devices.
Radio-frequency emission GB4824| Class B| The equipment is suitable for use in
all facilities, including household facilities and directly connected to
public low-voltage power supply network< of the household residential
Harmonic emission GB17625.1| applicableNot
Pressure fluc.ua.jor/scintilla.io? emission GB 7625.2| apply cable
Guide and manufacturer’s slatement-Hectromagnetic immurily
Electronic thermometer (RIT-POZ-MED、RIT-PO2-RR, RIT-PO2-RS、RIT-PO2-MM、 RIT-
PO2-R)’s intended to be used in the electromagnetic environment specific
below. The purchaser or use of the device shall er sure that it is used in
such an electromagnetic environment:
Immunity test| Test level| Qualified level| Electromagnetic environment-guide
Electrostatic discharge GB/T17626.2| +2kV/±4kV/+6Kv contact discharge
12kV/14kV/18KV air discharge| +2kV/±4kV/+6Kv contact discharge 12kV/14kV/18KV
air discharge| The floor should be wood, concrete or tile, and if the floor is
covered with syr the tic
licorice fast transient| =1Kv for ir out: /output| Not applicable| Not
applicable
Surge GB/T17626.5| +1Kv differential mode voltage +2kV common mode voltage|
Not applicable| Not applicable
voltage owner supplyemporarily or put lire, short. – arm interruption rd
voltage ariationGB/T1/626.11| <5% JT, con new CS cycle above UT>95% sage10%U
continue 5 cycles above UT.60% sage)70% JT, crore 25 c, des (above UT 30%
sag<5% JT,continue ESA Bove UT, 95% sage| Not applicable| Not applicable
Power frequency magnetic field (50/60+2) GB GB/T1/626.8| 3A/m| 3A/m,50/60Hz|
Power frequency magnetic fields should have the character’s.ics power
frequency magnetic fields in Lyrical commercial or hospi.al environmerls.
Note: UT means the ac network voltage before the test voltage is applied
Guide and manufacturer’s statement -Clectromagnetic immunity
Electronic thermometer (RIT-PC2-MCD、RIT-P02-RR, RIT-PO2-RS. RIT-P02-MV,
RIT-P02-R1) is interdict to be used in the electromagnetic environment
specified below. The purchase or user of the device shall ensure that it is
usec in such an electromagnetic environment
Immunity test| Test level| Qualify level| Electromagnetic environment – guide
Radio- frequency conduct on CB/T17626.6Radio- frequency radiation CB/T17626.3|
3V (effective value) 150kHz-80MHz3V/m/10V/m 80MHz ~2.5GHz| No: apol cable3٧/|
equipment shall not be used dozer tony part of the recommenced isolator
distance, including cables. The distance shall be calculate by a formula
corresponding to the transmitterfrequencyRecommended isolation
distanced-1.2Pd=1.2P80MHz~800MHzd=2.3P 800M47-2.5GH7in the formula: P-The
maximum rate output power olé Transmitter, in walls (W, provided by the
transmitter manufacturer;dhe recommended isolation distance in meters
(m)bathed field intensity of a stationary radio frequency rans miller ‘s
determined by an investigation of the electromagnetic field c, which should be
lower than the coincidence level at each frequency prance dint te emcee may
occur near devices marked with the following
Note 1: Use formula with higher frequency band 3: 80MHz and 800MHz
frequency.
Note 2. These guides may not be applicable for all situations, where
electromagnet transmission is affec.ec by absorption and reflection by
buildings, objects and he human body.
Recommended isolation distance between portable and mobile radio frequency communication devices and this device
Electronic thermometer (RIT-PO-MED, RIT-PO2-RR, RIT-PO-RS, RIT-PO?-MM, RIT-
PO-R1) is intended for use in electromagrctic environments where RF radiation
disturbance is controlled. Based on the maximum rated output power of the
communication device, the purchaser or use may or even: electromagnetic
interference by maintaining a minimum stance between portable and mobile radio
frequency communication devices (transmitter) and (this device, as recommended
below.
The rated maximum output power of the transmitted /W| Isolation distance
corresponding to the different frequency of the trar sir titer /m
0.01| Not applicable| 0.12| 0.23
0.1| Not applicable| 0.38| 0.73
1| Not applicable| 1.2| 2.3
10| Not applicable| 3.8| 1.3
100| Not applicable| 12| 23
For the transmitte rated maximum output power not listed the above taole, the
recommended solation diszarce ‘s d.in meters (m). It can be determined by the
formula in the corresponding transmitter frecuency bar. I lere P is the
maximum output rating of the transmitter, in watts (W), provided by the
transmitter manufacturer.
Note 1: Use formula with higher frequency band a: 80MI Iz and 800MI Iz
frequency
Note 2: These guides may not be applicable for all situations, where
electromagnetic trans mission is affected by absorption and reflection by bu
‘ldirgs, objects and the human body.
FCC Information and Copyright
This equipment has been tested and found to comply with the limits for a Class
B digital device. pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in
accordance with the Instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Labelling requirements.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- )This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
Read User Manual Online (PDF format)