FOCUHUNTER TPS-0006 10X50 Binoculars Telescope User Guide
- June 15, 2024
- FOCUHUNTER
Table of Contents
- FOCUHUNTER TPS-0006 10X50 Binoculars Telescope
- Product Usage Instructions
- FAQ
- PREPARATIVE JOB
- Diopter adjustment
- Specifications
- How to use the reticle and calculator dial as measuring devices
- How to use the compass
- using when wearing gas mask or glass
- Changing the batteries
- Tripod Mounting
- General maintenance
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
FOCUHUNTER TPS-0006 10X50 Binoculars Telescope
Specifications:
-
Magnification: 10x
-
Objective Lens Diameter: 50mm
-
Eyepiece Diameter: 23mm
-
Minimum Focus Distance: About 5m/16.4ft
-
Exit Pupil Diameter: 7.2mm
-
Exit Pupil Distance: 21mm
-
Waterproof: IPx7
-
Weight: 922g
-
Battery Type: LR44 (not included)
-
Lens Coating: FMC
-
Prism Material: BAK4
-
Field of View: 342ft@1000yds(1000m114m)
-
Features: Compass function & Rangefinder function
-
Size: About 200x150x80mm
-
Package Contents: binocular, instruction manual, eyepiece
cover, neck strap, shoulder bag, lens cleaning cloth -
Country of Origin: China
Product Usage Instructions
Assembly:
Before using the binoculars, assemble the binocular belt as shown in Fig 1.
Preparative Job:
Before observing the target, follow these steps:
Interpupillary Adjustment:
To adjust the binoculars for your eyes, hold the binoculars in both hands and bend it until you see a single circular image. Refer to Fig 2 for visual assistance.
Diopter Adjustment:
Close your left eye and rotate the right diopter adjustment ring until the object image appears sharp and clear in your right eye. Then open your left eye, close your right eye, and rotate the left diopter adjustment ring until the object image appears sharp and clear in your left eye. This will ensure a perfect viewing experience. See Fig 3 for reference.
TPS-0006 Instruction:
The TPS-0006 is a military binocular with an inter-built compass and a range finding reticle. It consists of an optical system and body assembly.
Optical System: Refer to Fig 4 for details.
Body Assembly: See Fig 5 for reference.
FAQ
Q: Can I watch the sun directly using these binoculars?
A: No, watching the sun directly using binoculars can harm your eyes. Avoid doing so.
Q: Can I use the binoculars near ferromagnetic materials?
A: It is advised to stay away from ferromagnetic materials such as cannon, tanks, battle vehicles, high voltage areas, transformer substations, ferromagnetic mills, and electric & ferromagnetic appliances while using the binoculars. Otherwise, the compass may work with big errors or improperly.
Thank you to choose our binoculars. In order to use it properly, please read
the instruction carefully according to the relative items no. and keep this
instruction well for further information in the future.
Please assembly the binocular belt before using , see Fig 1.
Be make sure to install the batteries into the military binocular if the binocular need the power to illuminate the compass.
CAUTION:
Do not watch the sun directly by using binocular to avoid to harm your eyes.
Be away from the ferromagnetism material during the working condition.
(such as cannon, tanks, battle vehicle, high voltage, transformer substation,
ferromagnetic mill, electric & ferromagnetic appliance),otherwise the compass
will work in big error or improperly.
PREPARATIVE JOB
Please follow the following instruction step before you are ready to use the
binocular to observe the target.
Interpupillary adjustment
You must first adjust the binoculars so that each eye piece is adjusted to the
distance between your eyes. This is done by putting the binocular in both
hands and bending it until you can see a single circular image. See Fig 2.
Diopter adjustment
To watch the object by handing the binocular , You will need to close your left eye. Rotate the right diopter adjustment rings untill the object image appears sharp and clear in your right eye opening. Then open you left eye and close right eye, rotate the left diopter adjustment rings untill the object image appears sharp and clear in your left eye opening. Then can get a perfect viewing. See Fig 3.
TPS-0006 instruction
TPS-0006 is the military binocular with inter-build compass and a range
finding reticle. It consists of optical system and body assembly.
optical system. See Fig.4
body assembly, see Fig.5
Specifications
see Fig.6
Item no | TPS-0006 |
---|---|
Magnification | 10x |
Eyepiece DIA | ∅ 23mm |
Exit Pupil DIA | 7.2mm |
waterproof | IPx7 |
Weight | 922g |
Lens Coating | FMC |
Field of view | 342ft@1000yds(1000mで114m) |
Features | Compass function & Rangefinder function |
Size | About200x150x80mm |
Package Contents | binocular, instruction manual, eyepiece cover, neck strap, |
shoulder bag, lens cleaning cloth
Country of Origin| China
How to use the reticle and calculator dial as measuring devices
- How to measure the Horizontal View Angle
The azimuth angles is the angle included between two objects to be measured at the horizontal direction of the binocular.
A. When the Horizontal View Angle is smaller than the horizontal scale range (-4~+4 mils) inside the binoculars, aim one edge of the object at a horizontal scale line(the center or the outmost line are selected according to the image size of object usually) and read its value. Then read the value of the scale at which another edge was located. Plus this two value, the sum value is the measured Horizontal View Angle. As shown in Fig 16, the Horizontal View Angle of the target (tank) is (-2~+2 mils), and the Horizontal View Angle is 4 mils. See Fig 7
B. When the Horizontal View Angle is bigger than the horizontal scale range (-4~+4 mils), an vertical line splits on the object can be selected to make the necessary estimated measurements in a step by step fashion. The sum of the value from each step is used to obtain the measured value. As shown in fig 17, the azimuth of target (cruiser) is 13 mils (6+7=13). see Fig.8
- How to measure the Vertical View Angle
Upper and lower angle means the angel included between any two targets (or two ends of the target) against the vertical line on the reticle. A. Vertical View Angle measurement is similar to measuring the Horizontal View Angle. When the Vertical View Angle measurement is small, aim the cross center of reticule at lower part of the object, read the scale value at the top of the object. As shown in Fig 18, the angle included between the upper and lower parts of the target is 6 mils. Fig.9
B. when the Vertical View Angle is larger than the vertical scale range (8 mils), it can be measured in steps and the angle can be obtained by summing up the value of each step. (The process will be similar to the measurements as mentioned above as horizontal view angle.) 3.)How to use the reticule to measure distance The distance measurement of a target can be calculated by using the mil reticule. See.Fig 10
How to use the compass
The azimuth angle can be measured through the compass built into the right half of the body . It shows the azimuth of the object relative to the observer. Each graduation of the compass equals one degree of angle. When the object lies in the north from you, the compass shows 0(degree) .And it will increase when you turn clockwise. 90 。means the object lies in the east from you, 180。means the south and 270。means the west. See Fig.11
In order to insure precise angle measurements, Be away from the ferromagnetism material during the working condition. (such as cannon, tanks, battle vehicle, high voltage, transformer substation, ferromagnetic mill, electric & ferromagnetic appliance),otherwise the compass will work in big error or improperly.
And the binoculars should be kept horizontal and level when reading the compass. The upper and lower angle can not be over ± 15. The object should lie in the middle of the reticule. The graduations of the compass need to be illuminated for convenient viewing when there is not sufficient daylight to illuminate the compass dial. Press the illuminator button, the compass scale will be illuminated in red light for easy viewing.
using when wearing gas mask or glass
TPS-0006 designed with Rubber fold-down eyecups. See Fig.12
Changing the batteries
The batteries for the compass will be exhausted if the internal lighting system has been used long periods of time. Batteries can also become weak if not used for a prolong period of time. If so, open the battery cover and replace with fresh batteries. Attention: The two batteries should be replaced at the same time. The batteries should be taken out if the binoculars will not be used for a long time. Batteries left in the binoculars for prolong periods of time without being used may leak and cause damage to the binoculars. See Fig 13.
Tripod Mounting
A standard threaded socket in 1/4 inch for tripod attachment is located at the base of the binoculars shaft. Insert a binoculars tripod adapter , and attach your tripod screw to the base of the adapter.
General maintenance
- Do not touch the lens by hand, be careful to protect the lens not to be injured by hard substance.
- Please fold the Interpupillary adjustment in lowness, put on the lens cover and put into the soft bag when you do not use it.
- Please use the clear and soft lens cloth to clear the lens. It is forbidden to clear the lens by hand, oilcloth, paper. Lens cloth should be keep in cleanliness in the binocular bag .Once the lens polluted by oil, please use the soft cotton cloth or silk to clear it with a little industrial alcohol.
Caution
- The military binocular is precision instrument, please follow the principle in using and storage:
- Be away from the ferromagnetism material during the storage the binocular with compass, otherwise the compass will work in big error or improperly.
- Do not turn the dioptar adjustment handwheel in overexerting , stop to turn when it reach the limited postion, otherwise the eyepieces assembly will be damaged!
- Be carefull to move the binocular to avoid overexerting or collision.To avoid the heavy vibration when you take it.
Storage:
Please put in the dryness place when you do not use it in long time. Suggest
to use dryer, and be away from ferromagnetism material.
Service and maintain
Do not take down and maintain yourself when the binocular can not work
properly, please send back to the factory or find the service centre.
Announcement:
Our factory will lay siege to the technology progress, We keep the right to
improve this products without any notice. It is according to the actual
products if we improve it.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>