Employer’s Responsibilities

Keep this manual available for use by all people assigned to the use of this tool.
Employer must enforce compliance with the safety warnings and all other instructions which accompany this tool as shipped from the manufacturer.
Tool actuation system must be appropriate taking into consideration the work application.
The operator must be trained in the safe use of the tool described in the operating safety manual.
Only persons who have read and understand the tool operating safety instructions shall operate the tool.

Warning

Read and understand tool labels and manual. Failure to follow warnings will result in DEATH or SERIOUS INJURY. Save These Instructions

Personal Protective Equipment

Use safety equipment. Always wear ANSI Z87+ safety glasses with permanently attached side shields. Dust mask, non-skid safety shoes, hard hat, or hearing protection must
be used for appropriate conditions. Failure to do so could result in personal injury. Eye protection equipment must be worn by the operator and other people in the work area.
Employer is responsible to enforce the use of personal protective equipment by the tool operator and all other personnel in the work area.
Eye protection shall conform to the requirements of ANSI Z87+ and shall provide protec- tion against flying particles both from front and side.
Hearing protection shall have Noise Reduction Rating determined in accordance with US Environmental Protection Agency Rules that is appropriate for the noise exposure.
Head protection shall conform to ANSI Z89.1.

Explosion Hazard

Never use tool in an explosive atmosphere or in the presence of combustible materials such as flammable liquids, gases or dust

Hazardous

Never use oxygen, carbon dioxide or any other bottled gas as a power source for this tool.; the tool will explode and cause serious injury.
Hazardous power sources shall not be used. Explosion may occur. Hazardous power sources include, but are not limited to:

  1. Reactive gases including, but not limited to oxygen and combustible
  2. Pressure sources that can deliver in excess of 1.5 times the maximum air pressure of a tool or 200 psig (13.8 bar), whichever is greater, if a regulator

Safety Warnings

Triggering Systems

Always select an actuation system that is appropriate for the fastener application and training of tool operator. Contact Senco at www.senco.com for information on actuation system options.

Tools are manufactured with a variety of triggering systems based on tool application, fastener size and operator preference. Please read the operating instructions so that you are familiar with the operation of each type of triggering system.

  • A sequential actuation mechanism is preferred when exact fastener placement is desired or the employer / operator prefer that the tool be reset for each fastener The operating controls must be activated in a specific sequence to activate the tool. If the tool has a trigger and workpiece contact, the workpiece contact must be activated before the trigger for the tool to operate. This type trigger is easily identified in your Senco tool by a BLACK trigger.
  • A contact actuation mechanism is an option when rapid fastener placement is This actuation system can be activated in any sequence. Additional activations can occur when any operating control is released and re-activated. This type trigger is easily identified in your Senco tool by a BLACK trigger.
  • Some tools have a selectable trigger option built into the triggering mechanism. These tools can be switched between sequential operation and contact actuation by moving a button, lever or See operator manual to determine if this selectable trigger is provided in your fastener driving tool. This type trigger is easily identified in your Senco tool by a RED trigger or BLACK trigger with RED switch.
  • Light duty tools may have only a finger trigger and do not require a work contact These tools are used in specialty applications and are typically used in industrial applications.
  • Light duty tools may have a dual action The two – stage trigger must be actuated in a sequence in order to drive a fastener. This type tool does not require a work contact element and is used for specialty applications.
  • Some special application tools utilize a retracted workpiece contact These tools are used for attaching straps to plates through pre-punched holes.

*Trigger color designation does not apply to metal connector.

It is recommended that operators that are less experienced using pneumatic fastener driving tools choose a sequential mechanism until they become familiar with the tool and its operation.
Please call Senco Customer Service to obtain an alternate trigger type in those tools that can be user modified to fit the application and/or level of operator experience.

Personal Safety

Always remove finger from trigger when not driving fasteners. Never carry the tool with finger on or under trigger. Tool will eject a fastener if the safety element is bumped.

Do not actuate tool unless tool is placed firmly against the work surface. Before operating, inspect tool to confirm:

  • Use of proper power
  • That tool is in proper working
  • Actuation system is on tool and how it
  • No misalignment or binding of moving
  • All conditions necessary for proper and safe tool Always assume the tool contains fasteners.
  • No
  • Respect the tool as a working
  • Keep tool pointed away from yourself and others when connecting air to

Do not use tool while tired or under the influence of drugs, alcohol or medication. A moment of inattention while oper- ating power tools may result in serious personal injury.
Do not overreach. Keep proper footing and balance at all times.

Always place yourself in a firmly balanced position.
Stay alert, focus on your work and use common sense when using tool. Keep bystanders and children away while operating tool.
Store idle tools out of the reach of minors or other untrained persons.
Drive fasteners into work surface only; never into materials too hard to penetrate. Do not force tool. Let the tool do the work.
Use the correct tool for the application. The correct tool will do the job better and safer.
Tools shall be operated at the lowest pressure needed for the application. This will reduce noise levels, part wear, and energy use.
Do not drive fasteners on top of other fasteners or with the tool at too steep of an angle; the fasteners can ricochet and may cause injury.
When using tool, care should be taken due to possibility of tool recoil after a fastener is driven.
If safety element is unintentionally allowed to re-contact work surface following a recoil, an unwanted fastener will be driven. Therefore, allow tool to recoil completely off work surface after a fastener is driven to avoid this condition.
Do not push safety element on work surface until a second fastener is desired.
Do not drive fasteners close to the edge of the work surface. Keep face and body parts away from tool and work sur- face. The workpiece is likely to split and the fastener could fly free or ricochet and may cause injury

Tool may eject a fastener when connected to air supply; therefore,

① remove all fasteners from tool
② before connecting air.

Do not load fasteners with trigger or workpiece contact element depressed.

Keep hands and body away from the fastener discharge area of tool near workpiece contact.

Operating Controls

Do not use tool without danger label on tool. If label is missing, damaged or unreadable, contact your SENCO represen- tative to obtain a new label.
Never use tool if safety element, trigger or springs have become inoperable, missing or damaged. Do not tamper with or remove safety element, trigger or springs.
Disconnect tool from air before doing tool maintenance, clearing a jammed fastener, leaving work area, moving tool to another location or handing the tool to another person, when not in use or outside of the operator’s supervision.
Tools shall not be modified unless authorized in tool manual or approved in writing by manufacturer.
Use only parts, fasteners, and accessories recommended or sold by SENCO. Do not modify tool without authorization from SENCO.

Proper Power Source

Use only clean, dry, regulated compressed air at recommended pressure. Do not operate the tool with any alternate power source.

Do not connect tools to air pressure that potentially exceeds 200 psig or 13.7 bar.
Regulators shall be used to limit compressed air pressure supplied to tool. Regulators shall be set at an operational pressure that is lower than or equal to manufacturers specified maximum.
Air hose must have a minimum working pressure rating of 150 PSIG (10.3 bar) or 150% of the maximum pressure produced in the system, whichever is higher.
The tool and air supply hose must have a hose coupling such that all pressure is removed from the tool when the coupling joint is disconnected

Use extra caution when driving fasteners into existing walls or other blind areas to prevent contact with hidden objects or persons on other side (e.g. wires, pipes, etc.).
Never use a tool that leaks air or needs repair. Never lift, pull or lower the tool by the hose.
Keep tool pointed away from yourself and others while connecting air to the tool.

Never use any part of the tool (cap or main body) as a hammer. The tool could activate or become unsafe.Read and understand all safety instructions

Read and understand all safety instructions

Product Safety Messages

  • Read and Understand tool labels and Failure to follow warnings will result in DEATH or SERIOUS INJURY.
  • Operators and others in work area MUST wear safety glasses with side
  • Keep fingers AWAY from trigger when not driving fasteners to avoid accidental
  • Know and understand what trigger system you are Check manual for triggering options.
  • NEVER point tool at yourself or others in work
  • NEVER use oxygen or other bottled Explosion may occur.

Maintenance

Always refer to both tool maintenance instructions below and the troubleshooting guide in this manual to assure years of reliable service.
Make sure all screws and caps are securely tightened at all times. Make daily inspec- tions for free movement of trigger and safety element. Never use the tool if parts are missing or damaged.
When tool is disconnected from air, make daily inspection to assure free movement of safety element and trigger. Do not use tool if safety element or trigger sticks or binds.
Squirt Senco pneumatic oil (5 to 10 drops) into the air inlet twice daily (depending on frequency of tool use). Other oils may damage O-rings and other tool parts.

Wipe tool clean daily and inspect for wear. Use non-flammable cleaning solutions only if necessary. DO NOT SOAK

The employer, tool owner and tool operator:

  • are responsible for ensuring that the tools are kept in safe working
  • are responsible for ensuring that only qualified personnel shall repair the
  • are responsible for ensuring that manufacturers tool maintenance instructions are available to personnel performing
    • shall ensure that tools that require repair are removed from service and that tags and physical segregation are used as a means of

Tool conditions that require the tool to be taken out of service:

  • Excessive leaks from pressure
  • Inoperable workpiece contact (safety element).
  • Workpiece contact (safety element) that appears to bind during
  • Missing
  • Missing safety
  • Delayed firing due to worn or damaged

Functional Operation

Tool Use

Read section titled “Safety Warnings” before using tool.

TO LOAD:

① Insert strip(s) of nails into rear of magazine. For optimum performance use SENCO fasteners. Do not load with workpiece contact (safety element) or trigger depressed.
⑤ Pull feeder shoe back.

UNLOADING THE TOOL:

Push Tab on feeder shoe to release feeder from strip. Pull fastener strip out past sheet metal nail detainer.

Do not load with workpiece contact (safety element) or trigger depressed.

Use only genuine SENCO fasteners (see Fastener Specifications)

CLEARING JAMS:

Should a fastener jam occur, disconnect air supply.

① Release the feeder shoe and slide it forward.
⑤ Remove fasteners from tool.

Clear jammed fastener from guide body.
Connect air supply and replace fasteners. Pull feeder shoe back.

This tool is equipped with a lockout feature:

When approximately five nails remain in the magazine, the workpiece contact (safety element) will be locked in the undepressed position until more nails are loaded into the magazine.

Repairs other than those described here should be performed only by

trained, qualified personnel. Contact SENCO for information at 1-800-543-4596.

Read section titled “Safety Warnings” before maintaining tool.

Functional Operation

Problem/Symptom Potential Cause Corrective Action
Air leak near top of tool / Sluggish operation Firing valve seal

air supply / Tighten screws or install repair kit YK0444
②| Air leak near bottom of tool / Poor return| Piston stop/Piston seal| Check for piston seal or sleeve wear

If parts are worn or damaged, parts are detailed in the parts chart

Clean tool / Tighten screws or install repair kit YK0445

Safety does depress fully, tool does not operate|  | Check safety. If unable to free up, return tool to an authorized dealer for service
 | Remove and inspect safety. Clean and lubricate track with SENCO oil
 | Replace safety
 | Position follower behind fasten- ers
Other problems|  | Contact SENCO

Accessories

SENCO offers a full line of accessories for your SENCO tools, including:

  • Air Compressors
  • Hose
  • Couplers
  • Fittings
  • Safety Glasses
  • Pressure Gauges
  • Lubricants
  • Regulators
  • Filters

Technical Specifications

TECHNICAL SPECIFICATIONS

Minimum to maximum operating pressure| 80 – 120 psi| 5.5 – 8.3 bar
Air Consumption (60 cycles per minute)| 5.20 scfm| 147,2 liter/min.
Air Inlet| 3/8″ NPT| 3/8″ NPT
Weight| 7.1 lbs.| 3,22 Kg
Fastener Capacity| 42| 42
Tool size: Height| 12.22″| 310,4 mm
Tool size: Length| 18.21″| 462,5 mm
Tool size: Width: Main Body| 4.5″| 114,4 mm
Maximum Fastener Size| 1 1/2″ (38 mm) Length x .109″ (2,8 mm) dia. shank

Fastener Specifications

SENCO FASTENER CODE

| A
---|---
INCHES| MM
W3050YXC| 1/2| 12,7
W3075YXC| 3/4| 19
W3100YXC| 1| 25,4
W3125YXC| 1 1/4| 31,8
W3150YXC| 1 1/2| 38,1
Head Diameter = 0.250″ / 6,4 mm

Limited Warranty

SENCO ® Pneumatic, DuraSpin ® , Cordless Tools & Compressors

KYOCERA-SENCO Industrial Tools, Inc. (“SENCO”) designs and constructs its products using the highest standards of material and workmanship. SENCO warrants to the original retail purchaser that the following products will be free from defects in material or workmanship for the warranty period

Products| New| Reconditioned| Products| New| Reconditioned
---|---|---|---|---|---
Pneumatic Tools?| Five Years| One Year| Air Compressors| One Year| 90 Days
Fusion Tools| Five Years| Six Months| Combo Kit Tools| One Year| 90 Days
Gas Tools| Two Years| Six Months| Multi-Blow Hand Nailers| One Year| 90 Days
Duraspin Tools| Five Years| 90 Days| Stapling Hammers| One Year| 90 Days

During the warranty period (which begins on the purchase date), SENCO will repair or replace, at SENCO’s option and expense, any product or part that is defective in materials or workmanship after examination by a SENCO Authorized Warranty Service Centre, subject to the exceptions, exclusions and limitations described below. Any replacement product or part will carry a warranty for the balance of the warranty period applicable to the replaced product or part. A DATED SALES RECEIPT OR PROOF OF PURCHASE FROM THE ORIGINAL RETAIL PURCHASER IS REQUIRED TO MAKE A

WARRANTY CLAIM. Warranty registration is also required and can be accomplished through on-line Product Registration at www.senco.com. To make a warranty claim, you must return the product, with proper receipt/proof of purchase and return transportation charges prepaid, to a SENCO Authorized Warranty Service Centre. A list of SENCO Authorized Warranty Service Centres can be found at www.senco.com or by calling

1-800-543-4596 toll free. SENCO will perform its obligations under this warranty within a reasonable time after approval of the warranty claim

SENCO Cordless:

  1. Subject to the exceptions, exclusions and limitations described below, SENCO warrants that the SENCO Cordless tool will be free from defects in materials and workmanship for two years after the purchase
  2. SENCO warrants that the batteries and chargers used with SENCO Cordless tools will be free from defects in material and workmanship for one year after the purchase

Warranty Exclusions

The following warranty exclusions apply: 1.

seals, driver blades, piston stops, and piston/driver assembly.

  1. This warranty does not cover parts damaged due to normal wear, misapplication, misuse, accidents, operation beyond the recommended speeds or voltage (electric units only), improper storage, or damage resulting from
  2. Prod
  3. Labour charges or loss or damage resulting from improper operation, maintenance or repairs are not covered by this

General Warranty Conditions

This warranty will be honoured only if:

  1. Clean, dry, regulated compressed air has been used, at air pressure not exceeding the maximum indicated on the tool casting;
  2. No e
  3. No d

maintenance instructions).

THIS WARRANTY IS THE ONLY WARRANTY ON THE PRODUCT, AND SENCO DISCLAIMS ALL OTHER WARRANTIES. ANY IMPLIED WAR- RANTIES WILL BE LIMITED IN DURATION TO THE APPLICABLE WARRANTY PERIOD SPECIFIED ABOVE. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. YOUR REMEDIES ARE SOLELY AND EXCLUSIVELY AS STATED ABOVE. SENCO SHALL IN NO EVENT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL, INDIRECT, OR SPECIAL DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. IN NO EVENT, WHETHER AS A RESULT OF A BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE) OR OTHERWISE, SHALL SENCO’S LIABILITY EXCEED THE PRICE OF THE PRODUCT WHICH

HAS GIVEN RISE TO THE CLAIM OR LIABILITY. ANY LIABILITY CONNECTED WITH THE USE OF THIS PRODUCT SHALL TERMINATE UPON THE EXPIRATION OF THE WARRANTY PERIOD SPECIFIED ABOVE. NO EMPLOYEE OR REPRESENTATIVE OF SENCO OR ANY DISTRIBUTOR OR DEALER IS AUTHORIZED TO MAKE ANY CHANGE OR MODIFICATION TO THIS WARRANTY.

Replacement of Tool Due to Natural Disaster

Such a claim will be honoured provided that the original retail purchaser had previously submitted a completed warranty registration card for the tool, and then submits proof of ownership and an acceptable statement describing such Act of God documented by an insurance carrier, police department,

Customer Satisfaction

If for any reason the product does not perform to the original purchaser’s satisfaction, it can be returned to the place of purchase within thirty days with dated sales receipt for a full refund of the purchase price (applies to new product sales only). © 2023 KYOCERA-SENCO Industrial Tools, Inc. CINCINNATI, OHIO 45244-1611 USA www.senco.com 160101

Read More About This Manual & Download PDF:

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals