Overview

Clover Assist Stand is elaborately designed for the Clover 10/7S to make reading/handwriting easier for visual impaired people. The stand is extremely compact and lightweight, and the operation is also very simple and intuitive. Enjoy hand-free reading and handwriting with a sufficient space.

Compositions

SIGHT CARE K0942 CLOVER Assist Stand
1

SIGHT CARE K0942 CLOVER Assist Stand 3

Operation

Unfold procedure

  • Step 1: Separate the main legs apartSIGHT CARE K0942 CLOVER Assist Stand 4
  • Step 2: Split the twin legs to form the V shapeSIGHT CARE K0942 CLOVER Assist Stand 5
  • Step 3: Slide the device into the slot of traySIGHT CARE K0942 CLOVER Assist Stand 6

Use Case

The stand is multifunctional to assist:

  • Reading
  • Handwriting
  • Far view
  • Mirror view

The operations may be varied based on different use cases. The followings are our recommended operations.

Case 1: Reading Mode

  • Adjust your comfortable reading angle.SIGHT CARE K0942 CLOVER Assist Stand 7

With the built-in stand of the device closed, the device is actually in the far view mode, the LED lights are off by default. However, for reading mode, we recommend to enter the reading/handwriting mode with both lights on for a better experience.

Enter the reading/handwriting mode by using one of the following device button operations:

  • Press and hold the Focus Control button for 3 seconds
  • Press and hold the color mode button and the True Color button at the same time for 3 seconds (For old devices without the Focus Control button )

In this mode, the LED lights will be turned on and the lights are all on the highest illumination. Notice: For old devices with old Firmware, there may  no reading/handwriting mode. You can also press and hold the. Power the button and click the Freeze button to turn on the lights for a better reading experienceSIGHT CARE K0942 CLOVER Assist Stand 13.

Case 2: Handwriting Mode

The following operations are the same as the reading mode described above:

  • Adjust your comfortable reading angle
  • Enter the reading/handwriting mode

There are four light statuses that can be applied to help the handwriting.SIGHT CARE K0942 CLOVER Assist Stand 14

  • Press and hold the Power button and click the Freeze button to turn on/off the two LED lights simultaneously
  • (The operation is compatible for all firmware versions)
  • Press and hold the Power button and press the Focus Control button to switch from three light statuses:
  • Left light on, Right light on, and All lights on/off (based on the latest setting).
  • Shadow reducing when handwriting
  • For the new device with AF-button , the lights can be controlled separately to reduce the shadow when writing.
  • For example, if you are left-handed, turn off the left LED light. If you are right-handed, you can turn off the right LED light to reduce the shadow.

Notice : The Left/Right light individual control and the shadow reducing feature are only available for a new device with the AF-buttonSIGHT CARE
K0942 CLOVER Assist Stand 15

Case 3: Far View

If the device is in the reading/writing mode, it is recommended to exit the mode first.

  • Press and hold the Focus Control button for 3 seconds
  • Press and hold the color mode button and the True Color button at the same time for 3 seconds.For old device without the Focus Control button

Notice : For old devices with old Firmware, there may be no reading/handwriting mode. You can also press and hold the Power button and click the Freeze button to turn off lights.

  • Adjust the viewing angle as the picture shows
  • Rotate the device around and face the back camera to the object which you want to viewSIGHT CARE K0942 CLOVER Assist Stand 16

Case 4: Mirror View

The following operations are the same as the far view mode described above

  • If you are in the reading/writing mode, exit first
  • Adjust the angle
  • Rotate the device around and face the front camera to the object which you want to view
  • Turn the Camera Switch right to open the front camera for Mirror View.SIGHT CARE K0942 CLOVER Assist Stand 18
Fold procedure

The folding procedure is as simple as unfolding.

  • * Step 1![SIGHT CARE K0942 CLOVER Assist Stand 19](https://manuals.plus/wp-content/uploads/2022/09/SIGHT-CARE-K0942-CLOVER-Assist-Stand-19.png)
    • Step 2SIGHT CARE K0942 CLOVER Assist Stand 20
    • Step 3SIGHT CARE K0942 CLOVER Assist Stand 21
    • Step 4SIGHT CARE K0942 CLOVER Assist Stand 22

Specifications

  • Dimension: <= 305 x 102 x 53 mm
  • Weight: <560 grams
  • Adjust angle:
  • 0-30°in the reading/handwriting mode