HYXIPOWER HYX-DMU-W/4G Data Management Unit User Manual

June 14, 2024
HYXIPOWER

HYXIPOWER logo User ManualHYXIPOWER HYX DMU W 4G Data Management
Unit HYX-DMU-W/4G
DATA
MANAGEMENT
UNIT

HYX-DMU-W/4G Data Management Unit

Carefully read this inverter user instructions before using.
Read and save these instructions.
© 2023 ZHEJIANG HYXI TECHNOLOGY CO., LTD. All rights reserved.
This document cannot be copied fully or partially, transferred, or distributed in any form without the prior written permission of ZHEJIANG HYXI TECHNOLOGY CO., LTD (hereinafter referred to as “HYXIPOWER”).
TRADEMARKS
HYXIPOWER logo and other HYXIPOWER trademarks are the trademarks or registered trademarks of HYXIPOWER All other trademarks mentioned herein are the properties of their respective owners.

Preface

Overview
This manual provides users with the product information of the data management unit (DMU) communication system device. Product information, detailed installation and usage, fault diagnosis and daily maintenance related precautions, does not include all information about the photovoltaic system.
To ensure the DMU communication system device can be correctly installed and used, and give full play to its superior performance. Before handling, installing, operating and maintaining the DMU, please read the instruction manual carefully and follow all safety precautions in the instruction manual.
Scope of Application
This manual is intended for the following devices:

  • HYX-DMU-W
  • HYX-DMU-4G Hereinafter, unless otherwise specified, it is referred to as “DMU” for short.

Safety Instructions
In order to ensure the user’s personal and property safety when using the product, and to use the product more efficiently and optimally, the manual provides relevant information and are highlighted using the following symbols.
The symbols that may be used in this manual are listed below, please read carefully to use this manual better.

  • This symbol indicates a hazardous situation which may present a risk of fatal electric shock, serious personal injury or fire.

  • This symbol indicates that instructions must be followed strictly to avoid a potential safety hazard.

  • This symbol indicates that the operation is prohibited and the person concerned should discontinue the operation.

Symbol Description
**** Do not dispose of the inverter as household waste.
**** The symbol indicates DC voltage.

Note that only professionals should install or replace the DMU.
Do not attempt to repair the DMU without Hyxi’s permission, otherwise it will affect the warranty of the device. If any DMU is damaged, please send the DMU back to Hyxi’s dealer for repair or replacement.
Please read all instructions and warnings in this manual carefully.
Please use the device according to the installation or usage method described in this document, otherwise it may cause personal injury or equipment damage.

Product Overview

This chapter mainly introduces the DMU appearance, packaging accessories, technical parameters, etc.
1.1 Product introduction
PV microinverter system
1.1.1 Microinverter
Microinverter (hereinafter referred to as microinverter) converts the DC output of PV panels into AC power that meets the requirements of the grid and transmits it in the power grid, the DMU continuously collects the operating data of each microinverter port and sends it to the monitoring platform, which constitutes the module-level monitoring of the microinverter system hardware base.
1.1.2 Data management unit ( DMU )
The DMU data management unit is a key component of the microinverter system. It is the power generation information transfer station of the microinverter system, which communicates through the Sub-1 communication module with the microinverter, collects the real-time operation data of the microinverter, and sends the collected microinverter operation data through Ethernet to Hyxi monitoring service system.
A single DMU data management unit can communicate up to 400 PV modules, i.e. it can communicate up to 400 1-in-1 series of microinverters or 200 2-in-1 series of microinverters or 100 4-in-1 series of microinverters. If the DMU data management unit is installed in a place with poor communication signal the environment may cause signal attenuation, resulting in the reduction of communication devices.

  • If the DMU is required to monitor as many photovoltaic modules as possible, the onsite installation of the DMU and the microinverter should follow the requirements in the user manual. The execution is performed, and the distance between the microinverter and the DMU is as close as possible to reduce obstruction.

1.2 Product model
This article mainly involves the following product models:

  • HYX-DMU-W
  • HYX- DMU-4G

HYXIPOWER HYX DMU W 4G Data Management Unit - Product 1.3 Monitoring System
The monitoring system collects the operating data and status of each microinverter in the system through the DMU data management unit, and uses the PC or APP to provide users with module-level monitoring to realize remote operation and maintenance. It is mainly composed of components, microinverters, DMU data management unit and other devices.
1.4 Product Appearance
1.4.1 Dimension of DeviceHYXIPOWER HYX DMU W 4G Data Management Unit -
Appearance 1.4.2 Interface Layout
HYX-DMU-4G(4G Version)HYXIPOWER HYX DMU W 4G Data Management Unit -
Interface

No. Description
Sub-1G antenna interface
SD card slot
USB port (Software upgrades only)
DRM port
Ethernet port
RS485
Power port
Reset button
SIM card slot
4G antenna

HYX-DMU-WIFI(WIFI Version)HYXIPOWER HYX DMU W 4G Data Management Unit -
Interface 1

No. Description
Sub-1G antenna
SD card slot
USB port (Software upgrades only)
DRM port
Ethernet port
RS485
Power port
Reset button
WIFI antenna

1.5 LED Indicator Panel
The LED indicator is used as a human-computer interaction interface to indicate the current working status of the DMU.

No. Ligtht
POWER
NET
COM.
ALARM

LED Indicator Status Description:

No. Description LED status Device status
Power indicator ON Power on
OFF Power off
Network communication (connecting to the server) Solid Normal
Flashing Abnormal
Microinverter communication (connecting to microinverter) Solid Normal
Flashing Abnormal
Fault condition ON Abnormal
OFF Normal

1.6 Anti-countercurrent Function(RS485 port)
1.6.1 Device list

  • Microinverter 1-in-1, 2-in-1, 4-in-1 series.

  • DMU :HYX-DMU-W / HYX-DMU-4G.

  • Electricity meter: Single phase meter (DDSU666) / Three phase meter (DTSU666).
    1.6.2 Controlling type

  • Type 1:Self-generation and consumption: Limit feed-in power to zero to prevent generated power from being transmitted to the grid.

  • Type 2:Restricted power grid connection: PV power generation can be connected to the grid, but within a certain range.

  • Type 3:PV power generation and load power consumption display: Accurately display PV power generation and local power consumption.

1.7 DRM Function(Australia/New Zealand only)
The DMU is connected to external control device through the standard RJ-45 port, and the DRM port to support the following requirements response mode.
DRM 0/5/6/7/8 and other modes can be supported when the DMU is connected with microinverter.

No. Description
DRM0 Disconnect the device
DRM1 Stop using electricity
DRM2 Do not use more than 50% of the rated power
DRM3 Do not use more than 75% of the rated power, and generate reactive power
DRM4 Increased electrical power usage (subject to other active DRMs)
DRM5 Stop power generation
DRM6 Generating power should not exceed 50% of rated power
DRM7 Generating power should not exceed 75% of rated power, and absorb

reactive power
DRM8| Increased power generation (subject to other valid DRMs)

Installation

2.1 Unpack and check
The device has been fully tested and strictly inspected before leaving the factory, but damage may still occur during transportation, please conduct a detailed inspection before signing for the product.

  • Check the box for damage.
  • Check whether the goods are complete and in accordance with the order according to the packing list.
  • Unpack and check that all device inside is intact.
  • Check whether the products in the box are in accordance with the packing list (adapter, green terminal, installation map, fixed base (including screws), quick safety guide, etc.).

2.1.1 Packing list

Name Quantity Unit
Power adapter 1 Set
Green terminal 1 PC
Installation map 1 PC
Quick installation guide 1 PC
Fixed base 1 PC
Mount 1 PC
Screws 1 Set
M6*50 expansion screw 4 PC
ST3.5*9.5 Cross tapping screws 2 PC
ST4.8*16Cross tapping screws 2 PC
  • If there is any damage or incomplete goods, please contact the shipping company or contact Zhejiang Hyxi Technology Co., Ltd. directly, and provide photos of the damage to facilitate service.
  • Do not discard the original packaging of the device. It is best to store it in the original packing box after the device is out of service and disassembled.

2.2 Preparation
2.2.1 Installation environment requirements
Before installing the DMU, make sure the site meets the following requirements:

  • Has a standard AC outlet
  • Router/LAN/4G network with Ethernet interface.

DMU installation environment requirements:

  • Keep away from dust, liquid, acid or corrosive gas.

  • Ambient temperature -20ºC to + 65ºC.

  • It is forbidden to install it where children can reach it.

2.3 Installation sequence

  1. Installing PV modules and Microinverters.
  2. Complete Installation Map.
  3. Install the DMU and power on the DMU.
  4. SIM card inserted into DMU or configured for WIFI.
  5. Creating a power station on a monitoring platform.
  6. View the micro reverse operation & communication status.
  7. Monitoring platform/APP to view the operation status of the power station.

2.3.1 Installation Procedure
Step 1: Connect to a network
HYX-DMU-4G (4G Version)
Step 1: Using 4G: Insert the SIM card into the SIM card slot on the side of the DMU until you hear a sound of “click”.HYXIPOWER HYX DMU W 4G Data
Management Unit - Installation

  • One mode selection between Wi-Fi mode and cable mode is enough.
    HYX-DMU-WIFI(WIFI version )

  • Send the wireless network account password to the DMU through the APP, see chapter XX for details

  • Cable mode: Insert one end of the cable into the Ethernet port of the DMU, and the other end into the broadband router port.HYXIPOWER HYX DMU W 4G Data Management Unit - DMU

NOTICE

  • One mode selection between Wi-Fi mode and cable mode is enough.
  • If the DMU data management unit is installed in a metal box or under a metal concrete roof, it is recommended to use a Sub-1G/4G RF extension cable or Sub- 1G/4G suction cup antenna, the Wi-Fi version is recommended to use Sub-1G/WiFi RF extension cable or Sub-1G/Wi-Fi sucker antenna, for suction cup antenna, please contact Hyxi or local distributors for purchase (please contact Hyxi technical support).
  • For more information about the sucker antenna please email [email protected].

Step 2: Installation location

  • Installing on the roof can increase the signal strength.

  • Installed in the center of the PV array.

  • Install at least 0.5m from the ground and at least 0.8m from corners.

  • Do not mount the DMU directly above metal or concrete to prevent signal attenuation.

Step 3: Installation method
Wall-mounted method
Wall-mounted installation method needs to be installed in a cool and dry indoor location. It should be kept away from heating equipment (wall heaters, ovens, etc.);
Note: You need to prepare yourself: marker pens, electric drills, screwdrivers and other tools.

  • Hang the mount on the wall, adjust the angle, and mark it with a marker pen.
  • Drill the hole at the mark using the corresponding specification drill.
  • Align the mount with the hole, and put the expansion screw through the hanging plate into the hole to fix it.
  • Use special screws to connect the base with the DMU device.
  • Fix the installed device on the mount with the supplied screws.
  • After connecting the power supply and the network, carry out debugging.

HYXIPOWER HYX DMU W 4G Data Management Unit - DMU 1 Desktop installation
Put the DMU on the table

  • Use special screws to connect the base fixture with the DMU device and place it vertically on the table.
  • After connecting the power supply and the network, carry out debugging.

HYXIPOWER HYX DMU W 4G Data Management Unit - DMU 2

Human-Computer Interaction

3.1 Installing the App
Method 1
Download and install the App through the following application stores:

  • App Store (iOS).
  • Google App market (Android, users other than mainland China ones).

Method 2
Scan the following QR code to download and install the App according to the prompt information:

https://www.hyxicloud.com/downloadPage/

3.2 APP User manual
For more information on using the HYXiPower APP, please refer to the user manual “HYXiPower APP”.

HYXIPOWER HYX DMU W 4G Data Management Unit - QR Code
1

https://www.hyxipower.com/frontInterface/
support/download_pdf/lang/en?id=36

3.3 System debugging
For system configuration and debugging, please refer to the user manual “HYXipower Local Debugging APP”.

HYXIPOWER HYX DMU W 4G Data Management Unit - QR Code
2

https://www.hyxipower.com/frontInterface/
support/download_pdf/lang/en?id=37

Appendix

4.1 Technical Parameter

Product Model HYX-DMU-W HYX-DMU-4G

Communication to Microinverter
Signal| Sub-1G| Sub-1G
Monitoring data limit from solar panels| 400| 400
Communication to Hyxi Cloud
Ethernet| RJ45x1, 100Mbps| RJ45x1, 100Mbps
Wireless| WI-F1:802.11b/g/n| 4G:TDD-LTE, FDD-LTE 3G:SCDMA
2G:GSM/GPRS
Data Acquisition Interval| Default: 5 mins 1-15 mins Configurable)
Power Supply (Adapter)
Type| External adapter
Adapter input voltage/frequency| 100-240V AC / 50-60Hz
Adapter output voltage/current| 12V/1A
Power consumption| 1.5W| 2.5W
General Data
Operating Ambient Temperature| – 20 to +65°C
Dimensions (Mit)| 106’79’216mm
Weight| 320g
Cooling| Natural Cooling
Enclosure Rating| IP20
Installation method| Desktop mounting / Wall mounting

4.2 Frequency range & transmitted power

| Frequency Range| Transmitted Power
---|---|---
| B1| 1920MHz–2170MHz| <24dBm
LTE| B3| 1710MHz–1880MHz| <24dBm
B7| 2500MHz–2690MHz| <24dBm
B8| 880MHz–960MHz| <24dBm
B20| 791MHz–862MHz| <24dBm
B28| 703MHz–803MHz| <24dBm
B38| 2570MHz–2620MHz| <24dBm
B40| 2300MHz–2400MHz| <24dBm
WCDMA| B1| 1920MHz–2170MHz| <24.5dBm
B8| 880MHz–960MHz| <24.5dBm
GSM| 900| 870MHz–960MHz| <33.5dBm
1800| 1710MHz–1880MHz| <30.5dBm
Sub-1G| 868MHz–868.58MHz| <15dBm
WiFi| 2400MHz–2483MHz| <15dBm

4.3 Installation Map

HYXIPOWER HYX DMU W 4G Data Management Unit - Mape

4.4 Contact Information
IIf you have any questions about this product, please contact us.
In order to provide you with faster and better after-sales service, we need your assistance in providing the following information.

  • Equipment model:
  • Serial number of the device:
  • Fault code / name:
  • A brief description of the fault phenomenon:

Version: v1.0 2023
The manual is subject to change without notice while the product is being improved.

Zhejiang Hyxi Technology Co., Ltd.
9-10F, Building 3, Jiuyao Commercial Center, Zhuantang Sub-district,
Xihu District, Hangzhou, Zhejiang Province, China, 310008
[email protected] www.hyxipower.com

HYXIPOWER HYX DMU W 4G Data Management Unit - QR Code
3

http://weixin.qq.com/r/wROmvp-Ea8IUrdvd90bT

IC Warning
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:

  1. This device may not cause interference, and
  2. This device must accept any interference, including interference that may cause undesired operation of the device.
  • RF warning for Mobile device:
    This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

FCC Warning
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Note: This equipment has been tested and found to comply with the limits for a Class B digital  device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This  quipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in  a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following  measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

HYXIPOWER logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>