Arovast Levoit Smart Ultrasonic Warm and Cool Mist Tower Humidifier User Manual
- June 14, 2024
- Arovast
Table of Contents
Levoit Smart Ultrasonic Warm and Cool Mist Tower Humidifier
Product Information:
The product is a Smart Humidifier with the model LUH-M102S-WUS.
It operates on AC 120V, 60Hz power supply and has a rated power of
118W, 1.05A. The water tank capacity is 2.6 gallons or 10 liters.
The maximum mist output is 500 mL/h, and it can run for up to 100
hours on the low mist setting. The noise level ranges from <28dB
(Low Cool Mist) to <32dB (High Warm Mist). The dimensions of the
humidifier are 8.4 x 10.0 x 28.7 inches or 21.4 x 25.3 x 72.8 cm,
and it weighs 6.7 lbs or 3.1 kg.
To access additional smart humidifier functions, you can
download the free VeSync app.
Product Usage:
1. Package Contents:
- Smart Humidifier (LUH-M102S-WUS)
2. Specifications:
-
Model: LUH-M102S-WUS
-
Power Supply: AC 120V, 60Hz
-
Rated Power: 118W, 1.05A
-
Water Tank Capacity: 2.6 gal / 10 L
-
Max Mist Output: 500 mL/h
-
Max Runtime: 100 hours on low mist setting
-
Noise Level: Lowest: <28dB (Low Cool Mist), Highest:
<32dB (High Warm Mist) -
Effective Range: Not specified
-
Dimensions: 8.4 x 10.0 x 28.7 in / 21.4 x 25.3 x 72.8 cm
-
Weight: 6.7 lb / 3.1 kg
3. Getting to Know Your Smart Humidifier:
The Smart Humidifier consists of various components:
- Top Cover
- Nozzles
- Muffler
- Mist Tube
- Water Inlet Tank
- Base Chamber
- Control Panel
- LED Display
- Humidifier Base
- Aroma Pad
- Aroma Box / Air Inlet
- Handles
- Water Tank
- Water Level Window
- Power Cord
- Cable Winder (Behind)
- Stand
- Silicone Tube
- Filter
- Overflow Valve
- Water Inlet
- Air Outlet
- Hot Water Cover
- Heating Element
- Pump Cover
- Water Level Sensor
- Transducer
4. Controls:
The Smart Humidifier features the following controls:
-
Mist Level Indicators: Indicates the current mist level (Low,
Medium, High) -
Auto Mode Indicator: Indicates when the humidifier is in auto
mode -
Warm Mist Indicator: Indicates when the warm mist function is
activated -
Power Indicator: Indicates the power status of the
humidifier -
Mist Level Button: Adjusts the mist level (Low, Medium,
High) -
Auto Mode Button: Activates the auto mode for automatic
humidity control -
Warm Mist Button: Activates the warm mist function
-
On/Off Button: Turns the humidifier on or off
Note: The VeSync app can also be used to control these functions
and access additional features.
For more detailed instructions on setup, usage, care &
maintenance, troubleshooting, and warranty information, please
refer to the user manual.
USER MANUAL
Levoit OasisMist® 1000S Smart Ultrasonic Warm and Cool Mist Tower Humidifier
Questions or Concerns?
Please contact us MonFri, 9:00 am5:00 pm PST/PDT at support@levoit.com or at
1-888-726-8520.
Table of Contents
Package Contents
2
Specifications
2
Safety Information
3
Getting to Know Your Smart Humidifier 6
Controls
8
Remote Control
9
Getting Started
9
VeSync App Setup
11
Using Your Smart Humidifier
12
Care & Maintenance
16
Troubleshooting
21
VeSync App Troubleshooting
24
Warranty Information
26
Customer Support
27
Package Contents
1 × Smart Ultrasonic Tower Humidifier 2 × Aroma Pad (1 Pre-Installed) 2 ×
Cleaning Brush 1 × Screwdriver 4 × Screw 1 × Stand 1 × Cable Winder 1 × Remote
Control 1 × Quick Start Guide 1 × User Manual
Specifications
Model
LUH-M102S-WUS
Power Supply AC 120V, 60Hz
Rated Power 118W, 1.05A
Water Tank Capacity
2.6 gal / 10 L
Max Mist Ouput
500 mL/h
100 hours on low mist setting
Max Runtime
Noise Level Effective Range Dimensions Weight
Note: The humidifier may run for a longer or shorter time depending on the
environmental temperature and humidity.
Lowest: < 28dB (Low Cool Mist) Highest: < 32dB (High Warm Mist)
250800 ft² / 2374 m²
8.4 x 10.0 x 28.7 in / 21.4 x 25.3 x 72.8 cm
6.7 lb / 3.1 kg
Note: To access additional smart humidifier functions, download the free VeSync app (see page 11).
2
READ AND SAVE THESE INSTRUCTIONS
SAFETY INFORMATION
To reduce the risk of fire, electric shock, or other injury, follow all
instructions and safety guidelines.
General Safety
· Only use the humidifier as described in this manual.
· Place the humidifier and cord so that it will not be knocked over. Do not
place near large pieces of furniture or in high-traffic areas.
· When not in use, turn the humidifier off and disconnect from power by
removing the plug from the outlet.
· Do not use the humidifier in wet environments.
· Keep the humidifier out of reach from children.
· Do not open the base or remove the water level sensor for self-servicing.
· Always unplug your humidifier from the power outlet before cleaning your
humidifier or detaching the humidifier base from the water tank.
· Always make sure to place the humidifier on a flat, level surface before
operation.
· Only fill the water tank with clean water. Never fill the water tank with
any other liquids.
· Do not place the humidifier near sources of heat, such as stovetops, ovens,
or radiators.
· Do not use other items as replacement parts for this product.
· Do not cover the nozzle while the humidifier is on. Doing so may damage the
humidifier.
· Do not immerse the humidifier base, power cord, or plug in water.
· Do not clean the humidifier immediately after turning it off, especially if
it has been diffusing warm mist. Allow the humidifier to cool down completely
before cleaning.
· Do not use the humidifier if it is damaged or not working correctly, or if
the cord is damaged. Do not try to repair it yourself. Contact Customer
Support (see page 27).
· This humidifier is not to be used by persons (including children) with
reduced physical, sensory, or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
· Supervise children when they are near the humidifier.
· Children should not clean or perform maintenance on the humidifier without
supervision.
· Children should be supervised to ensure that they do not play with the
humidifier.
· Not for commercial use. Household use only.
3
SAFETY INFORMATION (CONT.)
Power & Cord
· Ensure that the plug fits properly into a polarized socket.
· Your humidifier has a polarized plug (one prong is wider than the other),
which fits into a polarized outlet only one way. This is a safety feature to
reduce the risk of electric shock. If the plug does not fit, reverse the plug.
If it still does not fit, do not use the plug in that outlet. Do not bypass
this safety feature.
· Do not handle the power cord or plug with wet hands. Keep the plug and power
cord away from liquids.
· If the power supply cord is damaged, it must be replaced by Arovast
Corporation or similarly qualified persons in order to avoid an electric or
fire hazard. Please contact Customer Support (see page 27).
· Unplugging the power cord will disable remote control of the humidifier and
temporarily disconnect the humidifier from VeSync and other third-party apps.
Electromagnetic Fields (EMF)
This humidifier complies with all standards regarding electromagnetic fields
(EMF). If handled properly and according to the instructions in this user
manual, the appliance is safe to use based on scientific evidence available
today.
Caution: Risk of Leaks and Electric Shock
· Only add essential oils to the aroma pad.
· Do not add essential oils, supplemental water treatment liquids, or water
filters into the water inlet tank, base chamber, or water tank.
Caution: HOT Water Vapor
· Let nozzles and mist tube cool before touching or cleaning.
4
WARNING
INGESTION HAZARD: This product contains a button cell or coin battery.
WARNING: CHEMICAL BURN HAZARD.
· DEATH or serious injury can occur if ingested;
· A swallowed button cell or coin battery can cause Internal Chemical Burns in
as little as 2 hours;
· KEEP new and used batteries OUT OF REACH of CHILDREN;
· Seek immediate medical attention if a battery is suspected to be swallowed
or inserted inside any part of the body;
· Remove and immediately recycle or dispose of used batteries according to
local regulations and keep away from children. DO NOT dispose of batteries in
household trash or incinerate;
· Even used batteries may cause severe injury or death;
· Call a local poison control center for treatment information;
· Only use with a 3V CR2025 battery;
· Non-rechargeable batteries are not to be recharged;
· Do not force discharge, recharge, disassemble, heat above (manufacturer’s
specified temperature rating) or incinerate. Doing so may result in injury due
to venting, leakage or explosion resulting in chemical burns;
· Ensure the batteries are installed correctly according to polarity (+ and
-);
· Do not mix old and new batteries, different brands or types of batteries,
such as alkaline, carbonzinc, or rechargeable batteries;
· Remove and immediately recycle or dispose of batteries from equipment not
used for an extended period of time according to local regulations;
· Always completely secure the battery compartment. If the battery compartment
does not close securely, stop using the product, remove the batteries, and
keep them away from children.
· Place sticky tape around both sides of the battery and dispose of it
immediately in an outdoor trashcan or recycle safely;
· Store spare batteries securely;
· Empty recycling units on a regular basis;
· Use non-transparent containers to keep the batteries out of view.
Unfortunately, it is not obvious when a button or coin battery is stuck in a
child’s esophagus (food pipe). The child might:
· Cough, gag or drool a lot;
· Appear to have a stomach upset or a virus;
· Be sick;
· Point to their throat or stomach;
· Have pain in their abdomen, chest, or throat;
· Be tired or lethargic;
· Be quieter or more clingy than usual or otherwise “not themselves”;
· Lose their appetite or have a reduced appetite;
· Not want to eat solid food / be unable to eat solid food.
These sorts of symptoms vary or fluctuate, with the pain increasing and then
subsiding.
A specific symptom to button and coin battery ingestion is vomiting fresh
(bright red) blood. If a child does this, seek immediate medical help.
The lack of clear symptoms is why it is important to be cautious with “flat”
or spare button or coin batteries in the home and the products that contain
them.
5
GETTING TO KNOW YOUR SMART HUMIDIFIER
A. Top Cover B. Nozzles C. Muffler D. Mist Tube E. Water Inlet Tank F. Base Chamber G. Control Panel H. LED Display I. Humidifier Base J. Aroma Pad K. Aroma Box / Air Inlet
L. Handles M. Water Tank N. Water Level Window O. Power Cord P. Cable Winder
(Behind) Q. Stand
Inside Water Tank R. Silicone Tube S. Filter
Inside Base Chamber T. Overflow Valve U. Water Inlet V. Air Outlet W. Hot Water Cover X. Heating Element Y. Pump Cover Z. Water Level Sensor AA. Transducer
A B
C
D E
Water Inlet Tank (Upside Down)
F
G J
H
K
W
I X
R
S
L
MT
Y
U
Z
N
V
AA
Base Chamber (Top View)
O
Q
6
GETTING TO KNOW YOUR SMART HUMIDIFIER (CONT.)
Mist Level Indicators
Auto Mode Indicator
Warm Mist Indicator
Power Indicator
Mist Level Button
Auto Mode Button
Warm Mist Button
On/Off Button
Mist Level Indicators
Auto Mode Indicator
Mist Level Indicators Low Mist Medium Mist High Mist
Wi-Fi® Indicator No Water Indicator Relative Humidity (RH) Percentage
Warm Mist Indicator Sleep Mode Indicator
7
CONTROLS
Note: You can also use the VeSync app to control these functions, as well as additional app-only features (see page 11).
On/Off Button · Tap to turn the humidifier
on/off.
Sleep Mode Button
· Tap to turn Sleep Mode on/off (see page 13).
Note: During first use, the humidifier may take 1025 seconds to start
misting.
· Press and hold for 5 seconds to pair with the VeSync app. See the in-app
instructions for more information.
· Press and hold for 15 seconds to reset the humidifier. This will restore the
humidifier’s default settings and disconnect it from Wi-Fi® and the VeSync app
(see page 11).
Mist Level Button · Tap repeatedly to cycle
through mist level settings: low, medium, and high mist. · Press and hold for
3 seconds to turn the display off. Tap any button (except ) to turn the
display back on.
Wi-Fi Indicator · Turns on, off, or blinks to
indicate pairing status. See the VeSync in-app instructions for more
information.
No Water Indicator · Blinks when there is no water
in the tank. After this indicator blinks 10 times, the humidifier will turn
off. Refill the tank to resume using your humidifier. · Lights up when the
humidifier base is removed. Remains on until the humidifier base is replaced.
Warm Mist Button · Tap to turn Warm Mist Mode
on/off (see page 12).
Auto Mode Button · Tap to turn Auto Mode on
(see page 13). · Tap / to turn Auto
Mode off and resume manual controls, or tap for Sleep Mode.
8
REMOTE CONTROL
GETTING STARTED
The remote control can be used to control any of the humidifier’s functions
from a distance. The remote must be within 16 ft / 5 m of the humidifier to
work.
Note:
· Remove the plastic tab from the remote control’s battery compartment before
using.
· To replace the battery, see page 20.
1. Remove all packaging.
2. Flip the water tank over. Use the screwdriver to attach the stand to the
water tank with the 4 included screws. [Figure 1.1]
Display Off Button · Press to turn the humidifier display off. · Press any
button to turn the display
back on.
Humidity Level Button · Press to set a target humidity level from
4080% that’s used with Auto Mode. · Continue pressing to cycle through target
humidity options in increments of 10%.
Timer Button · Press to cycle through timer options from
112 hours. · Press and hold to quickly cycle through
options in increments of 1 hour.
On/Off Button
Display
Off Button
Auto Mode Button
Mist Level Button
Sleep Mode Button
Figure 1.1
Note: Do not overtighten the screws.
3. Take out the filter from inside the water tank. Remove the foam around the
filter.
4. Place the humidifier base on the water tank.
5. Optionally, peel off the sticker cover on the cable winder and attach the
cable winder to the back of the humidifier base.
6. Choose a hard, flat location for the humidifier at least 12 inches / 30 cm
away from any walls. The surface must be waterresistant. [Figure 1.2]
Warm Mist Button
Timer Button
Humidity Level Button
12 in / 30 cm
Figure 1.2
Note: Placing the humidifier away from walls ensures that the humidity sensor
and air inlets function properly.
9
GETTING STARTED (CONT.)
7. Mist should be directed away from walls, furniture, bedding, and
appliances. [Figure 1.3]. Avoid letting too much mist fall on the side of the
humidifier with the aroma box, as this may interfere with the sensor inside
the aroma box.
CAUTION
· Do not remove the water inlet tank during filling.
· Only add water into the water inlet tank or water tank. Do not add water
directly into the base chamber or mist tube.
· Do not add essential oils into the humidifier. Only add essential oils to
the aroma pad. [Figure 1.7]
Figure 1.3
Filling & Refilling
Note: Make sure the water tank is clean before filling.
1. Remove the top cover. [Figure 1.4] 2. Use a pitcher or bottle to fill the
water
inlet tank with room-temperature water. You can also add water directly to the
water tank. [Figure 1.5]
Figure 1.4
Figure 1.5
Note:
· We recommend using purified or distilled water to fill the tank.
· Do not fill with hot water.
· Using tap water may result in a white dust (dried minerals) on surfaces.
Figure 1.7 · Do not use water treatment liquids or
third-party water filters in this humidifier.
3. Use the water level window to see how much of the tank is filled. Do not
fill past the max line or water may overflow out of the vents in the handles.
4. Replace the top cover. [Figure 1.6] Figure 1.6
10
VESYNC APP SETUP
Note: Due to ongoing updates and improvements, the VeSync app may be slightly
different than shown in the manual. In case of any differences, follow the in-
app instructions.
1. To download the VeSync app, scan the QR code or search “VeSync” in the
Apple App Store® or Google Play Store.
Note: For AndroidTM users, choose “Allow” to use VeSync.
Wi-Fi Connection
· To disconnect Wi-Fi, press and
hold
for 15 seconds until the Wi-Fi
indicator turns off. This will restore the
smart humidifier’s default settings and
disconnect it from the VeSync app.
· To reconnect, please follow the instructions in the VeSync app for adding a device.
2. Open the VeSync app. If you already have an account, tap Log In. To create
a new account, tap Sign Up.
Note: You must create your own VeSync account to use third-party services and
products. These will not work with a guest account. With a VeSync account, you
can also allow your family and friends to control your smart humidifier.
3. Follow the in-app instructions to set up your smart humidifier.
Note: · You can use the VeSync app to connect
your smart humidifier to Amazon Alexa or Google AssistantTM. Follow the in-app
instructions to connect VeSync to your voice assistant. · Your phone must have
Location turned on while your phone is connecting to your smart humidifier.
This is required to establish the Bluetooth® connection. You can turn Location
off after your smart humidifier is finished connecting to the VeSync app.
11
USING YOUR SMART HUMIDIFIER
Note: Using the VeSync app allows you to control your smart humidifier
remotely and access additional functions and features (see page 11).
1. Plug in the humidifier. The indicators on the display will light up for 1
second, then turn off.
2. Tap to turn your humidifier on. The humidifier will start misting.
Note: · During first use, the humidifier may take
1025 seconds to start misting. · If there is no water in the tank, will
flash 10 times, and the humidifier will turn off. Fill the water tank (see
Getting Started, page 9).
3. Tap repeatedly to cycle through mist settings: Low, Medium, and High.
[Figure 2.1] Low Mist
Medium Mist
High Mist
Figure 2.1
4. Rotate the nozzle to adjust the direction of the mist. [Figure 2.2]
5. Optionally, use the controls or the VeSync app to turn on Auto Mode,
activate Sleep Mode, and more (see Controls, page 8).
6. When your room has reached your preferred humidity level, turn the
humidifier to a lower setting, or turn it off. A comfortable humidity level is
between 4060%.
Note: You can also set the humidifier to automatically stop misting when the
room reaches a specific humidity level (see Auto Mode, page 13).
7. Tap to turn your humidifier off.
Warm Mist
· Tap to turn Warm Mist Mode on/off. · The humidifier may take 15 minutes to
warm up before producing warm mist.
· Caution: Mist may be hot. Do not place your bare hands, face, or other
exposed skin over the nozzles while using warm mist. [Figure 2.3] Nozzles can
reach temperatures as high as 140ºF / 60ºC.
Figure 2.2
Note: · Direct the nozzle away from any furniture,
walls, or other objects to prevent them from getting wet. · Do not inhale the
mist directly from the nozzle.
12
Figure 2.3
Auto Mode
Auto Mode uses the humidifier’s sensor to automatically adjust the mist level
to maintain a target humidity level. The default target humidity level is 60%.
1. Tap
to turn Auto Mode on.
Note: The humidifier will automatically mist for 15 seconds after being turned on, even if the room has reached the target humidity level.
2. By default, Auto Mode uses Automatic Stop. The humidifier will stop misting when the highest target humidity level is reached (default 60%).
Note:
· In the VeSync app, you can turn Automatic Stop on/off.
· If Automatic Stop is off, the humidifier will keep running on low mist level
when the highest target humidity level is reached.
3. The humidifier will continue detecting the humidity level in the room. It will start and stop misting again according to the following table:
Room
Automatic
Relative Humidity * Mist Level
Under 50%
High
5055%
Medium
5560%
Low
Over 60%
Automatic Stop
*If you change the target humidity from 60%, the humidity percentages will change accordingly.
Setting Target Humidity
You can set a target humidity level from 4080%, in increments of 10%. There are several ways to change the target humidity:
· Change the target humidity in the VeSync app.
· Press on the remote control. Continue pressing to cycle through target humidity options.
· Press and hold
on the control
panel until the display flashes and
shows the target humidity. Continue
tapping to cycle through target
humidity options.
Sleep Mode
Sleep Mode changes the humidifier’s mist setting to low and turns off the
display lights.
· Tap to turn Sleep Mode on/off. · When Sleep Mode is on, you can
tap any button to wake up the display. If you stop touching the display, the
display will turn off again after 6 seconds.
· Once you wake up the display, tap any button again to exit Sleep Mode and
resume manual controls.
Turning Off the Display
The display will automatically dim after 3 seconds of inactivity.
· To turn off the display, press and hold for 3 seconds, or press on the
remote control.
· To turn the display back on, tap any button.
13
Using the Aroma Box
Your humidifier can be used for aromatherapy.
1. Push the aroma box at the back of the base and pull it out. [Figure 3.1]
· The aroma pads can be cleaned and reused after diffusing essential oils (see
Cleaning the Aroma Pad, page 19).
· The aroma is intended to be light.
· For information on replacement aroma pads, see page 19.
Figure 3.1 2. Put 810 drops of essential oils on the
aroma pad. [Figure 3.2] Figure 3.2 3. Insert the aroma box back into
the humidifier. 4. Turn on the humidifier. The humidifier will
automatically diffuse aroma when used. Note: Do not add essential oils, water
treatment liquids, or third-party water filters into the water inlet tank,
base chamber, or water tank. Only add essential oils to the aroma pad. [Figure
3.3]
Memory Function
· If turned off and unplugged, the humidifier will remember your settings for
Sleep Mode, Warm Mist Mode, Mist Level, and Wi-Fi, and will resume those
settings when turned back on.
· If turned off and plugged in, the humidifier will remember your settings for
Auto Mode, Sleep Mode, Warm Mist Mode, Mist Level, and Wi-Fi, and will resume
those settings when turned back on.
Automatic Shutoff
The humidifier will automatically turn off when all of the water in the tank
has been diffused. will show on the display and blink 10 times before the
humidifier turns off. Fill the water tank (see Getting Started, page 9).
If the humidifier base has been removed from the water tank, the humidifier
will automatically stop misting. will show on the display and will turn off
once the base is placed properly back on the water tank.
Figure 3.3 14
VeSync App Functions
The VeSync app allows you to access additional smart functions, including
those listed below.
Remote Control From Your Phone · Turn the humidifier on/off. · Cycle through
mist levels. · Turn Auto Mode on/off. · Set a target humidity level. · Turn
Sleep Mode on/off. · Turn the display lights on/off. · Turn Warm Mist Mode
on/off.
Monitor Humidity Levels · Check current humidity levels in the
humidifier’s environment.
Set Timers & Schedules · Program individual timers or create a
schedule for your smart humidifier.
Third-Party Voice Control · Compatible with Amazon Alexa and
Google AssistantTM for voice commands.
Note: The VeSync app is continually updated and app features will expand.
Important Tips
Your humidifier must have the correct level of water in the base chamber to
work properly. If there is too much water in the base chamber, the humidifier
cannot create mist.
· Do not place the humidifier on an inclined surface.
· Do not add water directly into the base chamber or mist tube. Only add water
to the water inlet tank or directly into the water tank. The humidifier will
automatically deliver the correct amount of water into the base chamber.
· Do not remove the water inlet tank during filling.
· Avoid moving or shaking the humidifier. [Figure 4.1] This may cause the
water tank pump to deliver too much water into the base chamber or reduce the
amount of water in the base chamber.
Figure 4.1
· Before moving the humidifier, turn it off and unplug it.
15
CARE & MAINTENANCE
Note:
· All maintenance should be done on a water-resistant surface.
· Change the water daily to avoid bacteria growth.
· Use a tissue or cloth to clean the nozzle regularly.
· If not using the humidifier for 1 week or longer, do not leave water inside.
Clean and dry the humidifier instead.
4. Pull the mist tube from the narrow end to remove it. [Figure 5.3]
Cleaning
You should clean your humidifier water inlet tank, base chamber, and water
tank every 3 days, and when you’re ready to store it.
Figure 5.3
5. Flip the water inlet tank over and remove the muffler. [Figure 5.4]
Note: · Never immerse the base in water or liquid.
Do not place any part of the humidifier in a dishwasher. · Do not use
detergents to clean the humidifier. · If you’ve been using the warm mist mode,
allow the humidifier to cool before cleaning.
1. Unplug the humidifier.
2. Remove and rinse the water tank cover. [Figure 5.1] 3. Remove the water
inlet tank from the humidifier base. [Figure 5.2]
Figure 5.4
6. Remove the boiling water cover from the humidifier base.
7. Rinse the water inlet tank, mist tube muffler, and boiling water cover.
8. Remove the humidifier base and pour out any water. Pour from the corner of
the base chamber to prevent water from damaging the humidifier. [Figure 5.5]
Figure 5.1
Figure 5.2
Figure 5.5
16
CARE & MAINTENENCE (CONT.)
9. Use a small brush to clean the base chamber. Rinse with roomtemperature
water.
Note: Do not allow water to contact the air outlet, aroma box, or underside of
the humidifier base.
10. Pour out any water in the water tank. Use a brush to clean the inside of
the tank, then rinse with room-temperature water. [Figure 5.6]
6 cups
Descaling Your Humidifier
To descale the humidifier (remove mineral buildup):
1. Remove the humidifier base from the water tank.
2. Fill the water tank with 6 US cups / 1,420 mL of distilled white vinegar.
[Figure 6.1]
Figure 5.6
11. Pull to remove the filter from the silicone tube. Wash the filter with
water and a soft cloth. [Figure 5.7]
Figure 6.1
3. Fill the base chamber with 1 US cup / 240 mL of distilled white vinegar
[Figure 6.2]
Figure 5.7
Note: Do not remove the silicone tube from the water tank.
12. Dry all parts with a cloth. Make sure all parts are completely dry before
reassembling or storing.
Figure 6.2
4. Carefully swish the vinegar around the tank and base chamber. Do not allow
liquid to contact the air outlet. [Figure 6.3]
Figure 6.3 17
DESCALING YOUR HUMIDIFIER (CONT.)
5. Allow the parts to soak for 1520 minutes. Vinegar will loosen scale
(mineral buildup) in the tank and base chamber. [Figure 6.4]
8. Pull to remove the filter from the silicone tube. Place the filter in a container and fill with enough vinegar to cover the filter. Soak for 1 hour. [Figure 6.7]
Figure 6.4 6. Pour out the vinegar. [Figure 6.5]
Figure 6.7
9. Rinse all parts until any vinegar smell is completely gone. [Figure 6.8]
Figure 6.5
7. Use a soft cloth and cleaning brush to remove scale from all parts.
[Figure 6.6]
Figure 6.8
Figure 6.6
18
Cleaning the Aroma Pad
1. Pull out the aroma box and remove the aroma pad. [Figure 7.1] Figure 7.1
2. Rinse the pad under warm, running
water. [Figure 7.2]
Replacing the Aroma Pad
If the aroma pad is stiff even after cleaning, then it needs to be replaced.
Extra pads are included with the humidifier. To maintain the performance of
your humidifier, only use official Levoit aroma pads. For more information,
contact Customer Support (see page 27).
Reassembling
1. Push the filter back onto the silicone tube. Place the filter in the water
tank. [Figure 8.1]
Figure 7.2
3. Dry the pad with a clean cloth. 4. Place the aroma pad back into the
aroma box. [Figure 7.3]
Figure 8.1
2. Replace the boiling water cover on the humidifier base. [Figure 8.2]
Figure 7.3
Note: Do not use liquid cleaners or detergents to clean the pad or any other
part of the humidifier.
Figure 8.2
3. Replace the mist tube on the water inlet tank. [Figure 8.3]
Figure 8.3 19
REASSEMBLING (CONT.) 4. Flip the water inlet tank over and
replace the muffler. [Figure 8.4] Figure 8.4 5. Place the water inlet tank in
the
humidifier base and replace the top cover. 6. Place the humidifier base
properly on the water tank. 7. Refill the tank, if necessary.
Replacing the Remote Control Battery
1. Remove the battery compartment by pinching the tab in and pulling the
compartment out. [Figure 9.1] 2. Remove the old battery 3. Replace with a new
3V CR2025 battery.
Make sure the polarities match. 4. Replace the battery compartment.
Pinch
Pull out
Figure 9.1
Storing
1. Follow the cleaning instructions (see page 16) and allow all parts to dry
completely before storing.
2. Wrap the power cord around the cable winder.
3. Store in a cool, dry location.
20
TROUBLESHOOTING
Problem
Possible Solution
Humidifier doesn’t turn on, or turns off unexpectedly.
Plug the humidifier into a working outlet and turn it on. Add purified or distilled water to the water tank.
Turn the mist level to a higher setting.
Fill the water tank.
Wait 30 seconds after turning the humidifier on. During first use, and after
cleaning or storage, the humidifier may take 1025 seconds to start misting.
Make sure the air inlets on the bottom of the humidifier base and in the aroma
box are not blocked.
Little or no mist comes out.
Clean the humidifier (see Care & Maintenance, page 16). Make sure the nozzles
are not blocked or clogged.
Make sure the humidifier is on a flat, level surface.
If the water tank or humidifier base was washed with detergent, rinse
thoroughly with clean water to remove any detergent. Do not use detergents to
clean the humidifier.
Clean or replace the pump cover. For information on replacements, contact
Customer Support (see page 27).
In Auto Mode, the humidifier will stop misting when the target humidity level is reached. Increase the target humidity or manually select a mist level (see Auto Mode, page 13).
Make sure the humidifier base is properly placed on the water tank.
Humidifier uses water too quickly.
The humidifier uses up water based on the environmental temperature and humidity. If your environment is cold and/or dry, the humidifier will run out of water faster.
Humidifier produces an unusual smell.
If the humidifier is new, unplug and rinse all parts, then place in a cool,
dry place for 12 hours.
If essential oils were placed on the aroma pad, rinse the pad under clean
water and allow it to dry.
Clean the humidifier (see Care & Maintenance, page 16).
21
TROUBLESHOOTING (CONT.)
Problem
Possible Solution
Make sure the water tank is properly in place (see Getting Started, page 9).
Set mist level to a lower setting.
Humidifier makes a loud or unusual noise.
Empty the base chamber. Place the humidifier base properly on the water tank,
then refill the tank.
The water pump makes sound when it is refilling the base chamber. This is
normal.
When using the warm mist function, the heating element may make a gurgling noise if the water level is low. Add more water to the water tank.
The humidifier may be malfunctioning. Stop using the humidifier and contact Customer Support (see page 27).
Mist leaks from the base.
Make sure the water tank is properly in place (see Getting Started, page 9).
White dust appears around the humidifier.
We recommend using purified or distilled water to fill the humidifier. Avoid
using water with high mineral content, such as tap water.
Clean the humidifier (see Care & Maintenance, page 16).
Avoid running the humidifier in a room with over 60% relative humidity.
Wipe any excess water off the top and bottom of the base.
Water visibly leaks from the humidifier.
Do not shake the humidifier. Make sure to place the humidifier on a flat, level surface.
Check the water tank for leaks. If there are leaks, contact Customer Support (see page 27).
Humidity may be too high. Turn down the mist level, turn off the humidifier, or open a door or window to the room.
The area around the humidifier is damp or wet from condensation.
Open a window to ensure proper airflow for the humidifier, or move the
humidifier to a more well-ventilated room.
Make sure the water tank is properly in place (see Getting Started, page 9).
When filling the water tank, wipe off excess water from the water tank and humidifier base.
Mist is not warm after tapping
Allow the humidifier to heat up for about 15 minutes to produce warm mist. Clean the heating element (see Care & Maintenance, page 16).
The mist is warm on the cool mist setting.
The heating element may still be warm after being used for warm mist. Allow the heating element to cool for at least 30 minutes.
22
TROUBLESHOOTING (CONT.)
Problem
Possible Solution
Mold grows inside the Clean the water tank and base chamber regularly (see Care & Maintenance,
humidifier.
page 16).
lights up red.
Fill the water tank. Place the humidifier base properly on the water tank.
Essential oil has little or no smell.
Add more essential oil. For best results, use pure essential oil.
The room may be larger than the humidifier’s effective range. Move to a room smaller than 300600 ft² / 2755 m².
Display shows an incorrect humidity percentage.
Moisture may have built up inside the humidity sensor. Make sure the nozzle is
facing away from the aroma box so that mist does not settle on the sensor
inside the aroma box (see diagram in Getting To Know Your Smart Humidifier,
page 6). Turn off the humidifier, remove the aroma box, and allow the sensor
to air dry.
If the humidifier is placed within 12 inches / 30 cm of a wall or in a corner,
the humidity sensor cannot provide a proper reading for the relative humidity
in the room.
The humidity sensor will give an improper reading if it is exposed to dust. Avoid using the humidifier in dusty rooms. Avoid using tap water in the humidifier as this can increase dust in the air.
Use a higher mist level setting.
The humidity level isn’t changing in my room.
Depending on your environment, the humidifier may take longer to humidify your
air.
The room may be larger than the humidifier’s effective range. If the room is
larger than 300600 ft² / 2755 m², the humidifier will not be as effective.
Display shows Error Code “E1”, “E2”, “E7”.
The humidifier is malfunctioning. Contact Customer Support (see page 27).
If your problem is not listed, please contact Customer Support (see page 27).
23
VESYNC APP TROUBLESHOOTING
Why isn’t my humidifier connecting to the VeSync app?
· Make sure your phone has Bluetooth® turned on and is not currently connected
to another Bluetooth device.
· During the setup process, you must be on a secure 2.4GHz Wi-Fi network.
Confirm that the network is working correctly.
· Make sure the Wi-Fi password you entered is correct.
· Make sure your humidifier and phone are within 30 ft / 10 m of each other.
· Reset the humidifier by pressing and holding for 15 seconds. Then try
connecting again.
My humidifier is offline.
· Make sure the humidifier is plugged in. The humidifier may appear to be
offline if it is unplugged, or if the outlet does not have power.
· Refresh the VeSync menu by swiping down on the screen.
· Make sure your router is connected to the internet and your phone’s network
connection is working.
· Reset the humidifier using one of these options:
a. Delete the humidifier from the VeSync app. Swipe left (iOS®) or press and
hold (Android), then tap Delete. Then reconfigure your humidifier with the
VeSync app.
b. Press and hold for 15 seconds. Then reconfigure your humidifier with the
VeSync app.
Note: Power outages, internet outages, or changing Wi-Fi routers may cause
your humidifier to go offline.
24
The VeSync app is displaying an incorrect humidity percentage while the
humidifier is turned on.
· The room may be larger than the humidifier’s effective range. Move to a room
smaller than 300600 ft² / 2755 m².
· Moisture may have built up inside the humidity sensor. Make sure the nozzles
are facing away from the aroma box so that mist does not settle on the sensor
inside the aroma box (see diagram in Getting To Know Your Smart Humidifier,
page 6). Turn off the humidifier, remove the aroma box, and allow the sensor
to air dry.
· If the humidifier is placed within 12 inches / 30 cm of a wall or in a
corner, the humidity sensor cannot provide a proper reading for the relative
humidity in the room.
· The humidity sensor will give an improper reading if it is exposed to dust.
Avoid using the humidifier in dusty rooms.
If your problem is not listed, please contact Customer Support (see page 27).
ATTRIBUTIONS
Apple App Store is a trademark of Apple Inc.
Google, Android, and Google Play are trademarks of Google LLC.
Wi-Fi® is a registered trademark of Wi-Fi Alliance®.
Amazon, Alexa and all related logos are trademarks of Amazon.com, Inc. or its
affiliates.
iOS is a registered trademark of Cisco Systems, Inc. and/or its affiliates in
the United States and certain other countries.
The Bluetooth® word mark and logos are registered trademarks owned by
Bluetooth SIG, Inc. and any use of such marks by Arovast Corporation is under
license. Other trademarks and trade names are those of their respective
owners.
FEDERAL COMMUNICATION COMMISSION INTERFERENCE STATEMENT – PART 15 This device
complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2)
This device must accept any interference received, including interference that
may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
· Reorient or relocate the receiving antenna. · Increase the separation
between the equipment and receiver. · Connect the equipment into an outlet on
a circuit different from that to which the receiver is connected. · Consult
the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate this
equipment.
FCC Radiation Exposure Statement This equipment complies with FCC radiation
exposure limits set forth for an uncontrolled environment. End users must
follow the specific operating instructions for satisfying RF exposure
compliance. To maintain compliance with FCC RF exposure compliance
requirements, please follow operation instructions as documented in this
manual. This transmitter must not be co-located or operating in conjunction
with any other antenna or transmitter. This equipment should be installed and
operated with a minimum distance of 20 cm between the radiator and your body.
The availability of some specific channels and/or operational frequency bands
are country dependent and are firmware programmed at the factory to match the
intended destination. The firmware setting is not accessible by the end user.
FEDERAL COMMUNICATION COMMISSION INTERFERENCE STATEMENT – PART 18 This device
complies with part 18 of the FCC Rules.
This equipment generates and uses ISM frequency energy and if not installed
and used properly, that is in strict accordance with the manufacturer’s
instructions, may cause interference to radio and television reception. It has
been type tested and found to comply with limits for an ISM Equipment pursuant
to part 18 of FCC Rules, which are designed to provide reasonable protection
against such interference in a residential installation. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause interference to radio or television reception, which
can be determined by tuning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following:
· Reorient the receiving antenna of radio or television. · Relocate the
equipment with respect to the receiver. · Move the equipment away from the
receiver. · Plug the equipment into a different outlet so that the equipment
and receiver are on different branch circuits.
Conduct only the user maintenance found in this manual. Other maintenance and
servicing can cause harmful interference and can void the required FCC
compliance. The manufacturer is not responsible for any radio or TV
interference cause by unauthorized modification to the equipment. It is the
responsibility of the user to correct such interference.
FCC SDOC SUPPLIER’S DECLARATION OF CONFORMITY
Arovast Corporation hereby declares that this equipment is in compliance with
the FCC rules. The declaration of conformity may be consulted in the support
section of our website, accessible from www.levoit.com
25
WARRANTY INFORMATION
Levoit OasisMist1000S Smart Product Ultrasonic Warm and Cool Mist
Tower Humidifier
Model LUH-M102S-WUS
For your own reference, we strongly recommend that you record your order ID
and date of purchase.
Order ID
Date of Purchase
Levoit Limited Product Warranty
Register your products at https://warranty.levoit.com/warranty to stay up to
date with important product information such as product updates, limited
warranties, usage and maintenance recommendations, and notifications
concerning safety warnings or product recalls. Registration is not required to
claim your limited warranty.
Two (2) Year Limited Consumer Product Warranty
Arovast Corporation (“Arovast”) warrants that the product shall be free from
defects in material and workmanship for a period of 2 years from the date of
original purchase (“Limited Warranty Period”), provided the product was used
in accordance with its use and care instructions (e.g., in the intended
environment and under normal circumstances).
Your Limited Warranty Benefits
During the Limited Warranty Period and subject to this limited Warranty
Policy, Arovast will, in its sole and exclusive discretion, either (i) refund
the purchase price if the purchase was made directly from the online Levoit
store, (ii) repair any defects in material or workmanship, (iii) replace the
product with another product of equal or greater value, or (iv) provide store
credit in the amount of the purchase price.
Who is Covered?
This limited warranty extends only to the original consumer purchaser of the
product and is not transferable to any subsequent owner of the product,
regardless of whether the product transferred ownership during the specified
term of the limited warranty. The original consumer purchaser must provide
verification of the defect or malfunction and proof of the date of purchase to
claim the Limited Warranty Benefits.
Be Aware of Unauthorized Dealers or Sellers
This limited warranty does not extend to products purchased from unauthorized
dealers or sellers. Arovast’s
limited warranty only extends to products purchased from authorized dealers or
sellers that are subject to Arovast’s quality controls and have agreed to
follow its quality controls. Please be aware, products purchased from an
unauthorized website or dealer may be counterfeit, used, defective, or may not
be designed for use in your country. You can protect yourself and your
products by making sure you only purchase from Arovast or its authorized
dealers.
If you have any questions about a specific seller, or if you think you may
have purchased your product from an unauthorized seller, please contact our
Customer Support Team via support@levoit.com.
What’s Not Covered?
· Normal wear and tear, including parts that might wear out over time (e.g.,
batteries, filters, cleaning brush, essential oil pads, etc.).
· If the proof-of-purchase has been altered in any way or is made illegible.
· If the model number, serial number or production date code on the product
has been altered, removed or made illegible.
· If the product has been modified from its original condition. · If the
product has not been used in accordance with
directions and instructions in the user manual. · Damages caused by connecting
peripherals,
additional equipment or accessories other than those recommended in the user
manual. · Damages or defects caused by accident, abuse, misuse, or improper or
inadequate maintenance. · Damages or defects caused by service or repair of
the product performed by an unauthorized service provider or by anyone other
than Arovast. · Damages or defects occurring during commercial use, rental
use, or any use for which the product is not intended. · If the unit has been
damaged, including but not limited to damage by animals, lightning, abnormal
voltage, fire, natural disaster, transportation, dishwasher, or water (unless
the user manual expressly states that the product is dishwasher-safe). ·
Incidental and consequential damages. · Damages or defects exceeding the cost
of the product.
Claiming Your Limited Warranty Service in 5 Simple Steps:
1. Make sure your product is within the specified limited warranty period.
2. Make sure you have a copy of the invoice and order ID or proof-of-
purchase.
3. Make sure you have your product. DO NOT dispose of your product before
contacting us.
4. Contact our Customer Support Team via support@levoit.com
5. Once our Customer Support Team has approved your request, please return
the product with a copy of the invoice and order ID.
26
Sole and Exclusive Remedy
THE FOREGOING LIMITED WARRANTY CONSTITUTES AROVAST CORPORATION’S EXCLUSIVE
LIABILITY, AND YOUR SOLE AND EXCLUSIVE REMEDY, FOR ANY BREACH OF ANY WARRANTY
OR OTHER NONCONFORMITY OF THE PRODUCT COVERED BY THIS LIMITED PRODUCT WARRANTY
STATEMENT. THIS LIMITED WARRANTY IS EXCLUSIVE, AND IN LIEU OF ALL OTHER
WARRANTIES. NO EMPLOYEE OF AROVAST CORPORATION OR ANY OTHER PARTY IS
AUTHORIZED TO MAKE ANY WARRANTY IN ADDITION TO THE LIMITED WARRANTY IN THIS
LIMITED PRODUCT WARRANTY STATEMENT.
Disclaimer of Limited Warranties
TO THE FULLEST EXTENT PROVIDED BY APPLICABLE LAW, EXCEPT AS WARRANTED IN THIS
LIMITED PRODUCT WARRANTY POLICY, AROVAST CORPORATION PROVIDES THE PRODUCTS YOU
PURCHASE FROM AROVAST CORPORATION “AS IS” AND AROVAST CORPORATION HEREBY
DISCLAIMS ALL WARRANTIES OF ANY KIND, WHETHER EXPRESS OR IMPLIED, STATUTORY,
OR OTHERWISE, INCLUDING BUT NOT LIMITED TO ANY WARRANTIES OF MERCHANTABILITY,
NON-INFRINGEMENT, AND FITNESS FOR PARTICULAR PURPOSE.
Limitations of Liability
TO THE FULLEST EXTENT PROVIDED BY APPLICABLE LAW, IN NO EVENT WILL AROVAST
CORPORATION, ITS AFFILIATES, OR THEIR LICENSORS, SERVICE PROVIDERS, EMPLOYEES,
AGENTS, OFFICERS, OR DIRECTORS BE LIABLE FOR:
(a) DAMAGES OF ANY KIND ARISING OUT OF OR IN CONNECTION WITH PRODUCTS
PURCHASED FROM AROVAST CORPORATION IN EXCESS OF THE PURCHASE PRICE PAID BY THE
PURCHASER FOR SUCH PRODUCTS, OR
(b) INDIRECT, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR PUNITIVE DAMAGES EVEN IF
AROVAST CORPORATION OR ONE OF ITS SUPPLIERS HAS BEEN ADVISED OF THE
POSSIBILITY OR LIKELIHOOD OF SUCH DAMAGES.
AND REGARDLESS OF WHETHER CAUSED BY TORT (INCLUDING NEGLIGENCE), BREACH OF
CONTRACT, OR OTHERWISE. OUR LIABILITY SHALL UNDER NO CIRCUMSTANCES EXCEED THE
ACTUAL AMOUNT PAID BY YOU FOR THE DEFECTIVE PRODUCT, NOR SHALL WE UNDER ANY
CIRCUMSTANCES BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, SPECIAL OR PUNITIVE
DAMAGES OR LOSSES, WHETHER DIRECT OR INDIRECT.
EXCEPT AS COVERED BY THIS LIMITED PRODUCT WARRANTY STATEMENT, AROVAST
CORPORATION SHALL NOT BE LIABLE FOR COSTS ASSOCIATED WITH THE REPLACEMENT OR
REPAIR OF PRODUCTS PURCHASED FROM IT, INCLUDING, BUT NOT LIMITED TO, LABOR,
INSTALLATION, OR OTHER COSTS INCURRED BY THE USER AND, IN PARTICULAR, ANY
COSTS RELATING TO THE REMOVAL OR REPLACEMENT OF ANY PRODUCT.
OTHER RIGHTS YOU MAY HAVE
SOME JURISDICTIONS DO NOT ALLOW FOR: (1) EXCLUSION OF IMPLIED WARRANTIES; (2)
LIMITATION ON THE DURATION OF IMPLIED WARRANTIES; AND/ OR (3) EXCLUSION OR
LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES; SO THE DISCLAIMERS IN THIS
POLICY MAY NOT APPLY TO YOU. IN THESE JURISDICTIONS YOU HAVE ONLY THE IMPLIED
WARRANTIES THAT ARE EXPRESSLY REQUIRED TO BE PROVIDED IN ACCORDANCE WITH
APPLICABLE LAW. THE LIMITATIONS OF WARRANTIES, LIABILITY, AND REMEDIES APPLY
TO THE MAXIMUM EXTENT PERMITTED BY LAW.
ALTHOUGH THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, YOU MAY HAVE
OTHER RIGHTS IN YOUR JURISDICTION. THIS STATEMENT OF LIMITED WARRANTY IS
SUBJECT TO APPLICABLE LAWS THAT APPLY TO YOU AND THE PRODUCT. PLEASE REVIEW
THE LAWS IN YOUR JURISDICTION TO UNDERSTAND YOUR RIGHTS FULLY.
CHANGES TO THIS POLICY
We may change the terms and availability of this limited warranty at our
discretion, but any changes will not be retroactive.
This warranty is made by:
AROVAST CORPORATION 1202 N. Miller St., Suite A Anaheim, CA 92806, USA
CUSTOMER SUPPORT
If you have any questions or concerns about your new product, please contact
our helpful Customer Support Team.
Arovast Corporation 1202 N. Miller St., Suite A Anaheim, CA 92806, USA
Email: support@levoit.com Toll-Free:
1-888-726-8520
Support Hours
MonFri, 9:00 am5:00 pm PST/PDT
*Please have your order invoice and order ID ready before contacting Customer Support.
27
A0_23J13_us
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>