Haier HP250M1-U1 Monoblock Heat Pump Water Heater User Guide
- June 15, 2024
- Haier
Table of Contents
Haier HP250M1-U1 Monoblock Heat Pump Water Heater
Product Information
- The Heat Pump Water Heater is available in two models:
- HP200M1-U1 and HP250M1-U1. It features various controls and modes for efficient operation.
- The controller has a power ON/OFF button and a MODE key to switch between four working modes:
- AUTO, ECO, ELEC, and VAC.
- It also allows you to adjust clock settings, set timer functions, and confirm changes to settings.
- The controller has indicators for the heat pump and electric heating operation and a lock screen display icon.
- It can be used with a supplementary photovoltaic (PV) solar power supply.
Product Usage Instructions
- Temperature:
- Turn on the appliance by pressing the power button if in Standby mode.
- Set the desired temperature using the temperature adjustment buttons.
- After 6 seconds of keyless operation, the settings will be confirmed and you will return to the operational mode.
- Note: It is recommended to set a minimum temperature of 60 to prevent bacteria growth in stored hot water.
- Time:
- Turn on the appliance by pressing the power button if in Standby mode.
- Press the TIMER key until the display shows the hours flashing 00:00.
- Set the desired hours using the TIMER key.
- Press the TIMER key until the display shows the minutes flashing at 00:00.
- Set the desired minutes using the TIMER key.
- After 6 seconds of keyless operation, the current time settings will be confirmed and you will return to the operational mode.
- AUTO Mode:
- Note: The appliance must be connected to a power supply providing electricity 24 hours per day for this mode to work.
- Turn on the appliance by pressing the power button.
- Press the MODE keys until the display shows the AUTO icon.
- Set the desired temperature using the temperature adjustment buttons.
- Your appliance will begin operating in AUTO mode to reach the set temperature. It may take up to 5 minutes for the heat pump to start working.
- If hot water is required immediately after installation, you can use the BOOST key to activate the electric element along with the heat pump for faster recovery. This is not a working mode but a temporary boost until the set temperature is reached.
- Your appliance will reach the set temperature and hot water will be available for use.
- For more advanced settings and fault codes, refer to the user manual.
INFORMATION
Start-Up Controls
This guide is designed to better explain the controls and operation of the basic modes currently available to you with your Heat Pump Water Heater.
- Temperature and Time
- AUTO mode (Automatic operation)
- ELEC mode (Electric element)
- VAC mode (Vacation)
- BOOST function
- Lock screen
- Service mode (advanced settings)
- Fault codes (advanced settings)
Temperature and Time
Temperature
- Turn on the appliance by pressing the key if in Standby, otherwise disregard this step. _
- Press the + or – keys to adjust the temperature in 1℃ increments until the desired temperature is reached.
- Note: A minimum of 60℃ is recommended for stored hot water to help prevent undesirable bacteria.
- Once the desired set temperature is displayed, the settings will be confirmed after 6 seconds of keyless operation and you will return to the operational mode.
Time
- Turn on the appliance by pressing the key if in Standby, otherwise disregard this step. _
- Press the TIMER key until the display shows the hours flashing “00:00.”
- Press the + or – key to adjust the 24 hour time. _
- Press the TIMER key until the display shows the minutes flashing “00:00.”
- Press the + or – key to adjust the minutes.
- Once the current time is displayed, the settings will be confirmed after 6 seconds of keyless operation and you will return to the operational mode.
AUTO mode
Note: This appliance must be connected to a power supply providing electricity 24 hours per day. This mode is designed to automatically operate the heat pump when the temperature has dropped by a specified amount, just like a thermostatically controlled hot water cylinder.
AUTO Mode (under default settings)
- Turn on the appliance by pressing the key.
- Press the MODE keys until the display shows the AUTO icon.
- Press the + or – key to adjust the temperature to the desired settings as described in step 01.1. A minimum of 60℃ is recommended.
- Your appliance should begin to operate in AUTO mode to reach the set temperature. It may take up to 5 minutes for the heat pump to initiate operation.
- If hot water is required as soon as possible after installation, the BOOST key can operate the electric element in addition to the heat pump for faster recovery. This is not a working mode but will assist until the set temperature is reached, returning to the previous working mode. As this is an energy-efficient appliance, the heat pump should remain the main source of heating wherever possible.
- Your appliance should reach the set temperature and hot water will be available for use.
- The default temperature differential is 10℃ for the HP200 model and 9℃ for the HP250 model. This means that at any time of the day or night, when the actual water temperature drops by this amount below the set temperature, the heat pump will operate.
- The temperature differential can be adjusted in the Service mode further in this guide.
ELEC mode
Note: This mode is designed to provide heating if the heat pump is not
operating for any reason. If there is a fault with the heat pump module,
follow this guide to ensure available hot water until a technician can resolve
the issue.
- Turn on the appliance by pressing the key if in Standby, otherwise disregard this step.
- Press the MODE keys until the display shows the ELEC icon.
- The water heater should now heat via the electric element until the set temperature is reached. The element icon will be displayed to indicate its operation.
- If there is a fault with the heat pump module, call Fisher & Paykel for service support.
VAC mode
Note: This mode is designed to maintain a minimum water temperature to
conserve energy during a period of absence from the property. The unit
automatically reheats the water in advance of the return date set.
- Turn on the appliance by pressing the key if in Standby, otherwise disregard this step.
- Press the MODE keys until the display shows the VAC icon.
- The two-digit temperature display flashes “01.” Press the + or – key to adjust the number of days you will be away on vacation. The selectable range is between 1–99 days.
- Press the SET key to confirm. The temperature display status will return and the value from the previous mode will be used.
- If the appliance is switched off or the mode is changed, VAC mode will be reset and the number of days entered will be lost.
- According to the vacation days entered by the user, heating will begin at 12:00 on the second to last day of the vacation period. The first heating cycle will heat to 65℃ to ensure that the water sterilization requirements have been reached. After the heating is completed, the appliance with switch to AUTO mode.
Boost function
- BOOST mode will take priority over other modes.
- This mode will run for a single heating cycle, then revert back to the previous mode set.
- In this mode, the heat pump and backup electric element operate simultaneously to reduce the heating time.
- When operating, the icon will appear. After the set temperature has been reached, the icon will disappear and the appliance will operate in the mode used prior to the BOOST function.
Lock screen
- With the appliance turned on, hold the TIMER and BOOST keys simultaneously for 6 seconds.
- The controller will beep twice and the lock screen icon will appear, indicating the screen is locked.
- To exit the lock screen, hold the TIMER and BOOST keys simultaneously for 6 seconds. The controller will beep 4 times and the lock screen icon will disappear. The controller will now be adjustable.
Service mode Note:
Many of the features in service mode are for advanced configurations with
connections to off-peak power switching or solar, however, there are some
settings in here that could be beneficial for adjustments to your system such
as water sterilization, heat pump maximum working time, setting the day of the
week and temperature differential.
Enter Service Mode:
- Enter the Standby Mode by pressing the key, only the temperature and time will be displayed.
- Press and hold the + and SET keys for 6 seconds to enter Service Mode.
- “LL” will be displayed. The options are “NO” normally open (default) and “NC” normally closed. This setting is used for off-peak or solar switching signals. Advanced technical use only. Press the SET key to enter the next setting.
- “LP” will be displayed. The options are for the off-peak logic type used in ECO mode;
- Manual timer (user-defined time periods of operation)
- Off-peak power switching signals (for meters capable of off-peak automatic power switching.)
- Photovoltaic (PV) switching signals (for supplementing with photovoltaic (PV) solar energy.) Advanced technical use only. Press the SET key to enter the next setting.
- “LA” will be displayed. The PV function will work in AUTO mode, the options are “ON” or “OFF”, Press + or – key to cycle through settings. This will switch PV operation mode on when there is a PV signal in AUTO mode, if using PV, we recommend this setting is “ON.” Disregard if no PV in use. Press SET key to enter the next setting.
- “Lb” will be displayed. This setting is used to set the heating temperature when connected to PV solar panels. The adjustable range is between 65-75℃, the default is 65℃. Press + or – key to cycle through settings. Disregard if no PV in use. Press SET key to enter the next setting.
- “LC” will be displayed. This setting is used to determine the heating source when connected to PV solar panels, a signal is active and there is sufficient solar electricity supply. The options are; “01” The heat pump and electric element will operate simultaneously. Default. “02” The heat pump will operate and if set temperature is not reached within the differential setting, the electric element will assist in heating. “03” Only the electric element will be used for heating. Disregard if no PV in use. Press + o rkey to cycle through settings. Press SET key to enter the next setting.
- “AL” will be displayed. Periodic water sterilization by heating can be selected. The options are “ON” to enable this function (default) or “OFF” to disable the function, press + or – key to cycle through settings. Press SET key to enter the next setting.
- “Ah” will be displayed. The temperature of water sterilization can be adjusted if the above function is “ON,” press + or – key to cycle through settings between 65–75℃. Press SET key to enter the next setting.
- “Ad” will be displayed. The frequency of the water sterilization can be adjusted by days between 7–30, the default is 7. Press + or – key to cycle through settings. Press SET key to enter the next setting.
- “AA” will be displayed. This is the maximum working time of the heat pump before auxiliary heating activates. The hours can be adjusted between 5–15, the default is 10. Press + or – key to cycle through settings. Press SET key to enter the next setting.
- “Ct” will be displayed. This setting is used to set the current day of the week, adjustable from 1–7, with Monday being 1 and Sunday being 7. Press + or – key to cycle through settings. Press SET key to enter the next setting.
- “Bt” will be displayed. This is the temperature differential. This setting controls when the heat pump will start operation after the actual temperature drops below the set temperature. The adjustable range is between 5–15℃, the default is 10℃. Press + or – key to cycle through settings. Press SET key to confirm.
- You will now return to the standby mode display. Press the key to enter operational mode. Your system should begin operating within the next 5 minutes.
Fault codes
Enter Fault code query:
- Enter the Standby Mode by pressing the key, only the temperature and time will be displayed.
- Press and hold the + and – keys for 6 seconds to enter Fault codes.
- “E0” will be displayed if there is no fault. If there is a fault, it will be displayed in order of the last known fault. Press the – key to scroll back to previous faults until the oldest stored fault E01 is displayed. The last 10 fault codes are stored in the appliance.
- If no keys are pressed for 6 seconds, the appliance will exit this mode. Pressing the key will also exit and return to Standby Mode.
- To clear the fault code memory, press and hold the + and – keys simultaneously for 6 seconds whilst in the fault code mode.
E0 | No faults found | E4 | Ambient temperature sensor fault |
---|---|---|---|
F0 | Communication fault (Wi-Fi) | E5 | Evaporation temperature sensor fault |
F2 | Operating temperature protection | E6 | Air exhaust temperature sensor fault |
F3 | Air exhaust temperature protection | ED | Air intake temperature sensor |
fault
F5| Evaporation high temperature protection| E7| Communication fault (display-
control panel)
F6| Compressor over-current protection| E8| Pressure switch protection
E1| Electrical leakage alarm| E9| Ambient temperature protection
E2| Over temperature alarm (stored water)| EF| Off-peak power switching signal
fault
E3| Inner temperature sensor fault| L7| Fan fault
ECO Mode Controls
This guide is designed to better explain the controls and operation of the three economy modes currently available to you with your Heat Pump Water Heater
- Manual timer
- Off-peak power signal
- Photovoltaic (PV) solar power
Manual timer operation
Note: This appliance must be connected to a power supply providing
electricity 24 hours per day. This mode is designed to manually set the times
of operation for either the off-peak time, in preparation for periods of high
hot water usage, to take advantage of higher ambient temperatures for maximum
gains or to limit operational noise during certain periods (eg; night time.)
These settings should be available under the appliances default settings. If
the settings are different to default this guide will also explain how to
achieve the desired settings in the first 12 steps.
Enter Service Mode:
- Enter the Standby Mode by pressing the key, only the temperature and time will be displayed. Note: Skip to step 12 if all settings remain default or the appliance is in its first-time use.
- Press and hold the + and SET keys for 5 seconds to enter Service Mode.
- “LL” will be displayed. Disregard if using manual timer. Press SET key to enter the next setting.
- “LP” will be displayed. For manual timer, press + or – key to cycle through settings until “01” is displayed. Press SET key to enter the next setting. 5. Press the SET key to cycle through the next three settings, disregarding “LA” “Lb” “LC” .
- “AL” will be displayed. Periodic water sterilization by heating can be selected. The options are “ON” to enable this function (default) or “OFF” to disable the function, press + or – key to cycle through settings. Press SET key to enter the next setting.
- “Ah” will be displayed. The temperature of water sterilization can be adjusted if the above function is “ON,” press + or – key to cycle through settings between 65–75℃. Press SET key to enter the next setting.
- “Ad” will be displayed. The frequency of the water sterilization can be adjusted by days between 7–30, the default is 7. Press + or – key to cycle through settings. Press SET key to enter the next setting.
- “AA” will be displayed. This is the maximum working time of the heat pump before auxiliary heating activates. The hours can be adjusted between 5–15, the default is 10. Press + or – key to cycle through settings. Press SET key to enter the next setting.
- “Ct” will be displayed. This setting is used to set the current day of the week, adjustable from 1–7, with Monday being 1 and Sunday being 7. Press + or – key to cycle through settings. Press SET key to enter the next setting.
- “Bt” will be displayed. This is the temperature differential. This setting controls when the heat pump will start operation after the actual temperature drops below the set temperature. The adjustable range is between 5–15℃, the default is 10℃. Press + or – key to cycle through settings. Press SET key to confirm.
- You will now return to the Standby Mode display. Press the key to enter operational mode.
- Press the MODE key until you are in ECO mode, the icon will be displayed.
- Press the SET key to begin entering times of operation.
- “L1” will be displayed. This is the first time period during the week (Monday–Friday.) “START” will be displayed indicating the start time of the heating cycle, and the hours will begin flashing 00:00. Press + or – key to adjust the start hour of the first timer. Press the SET key to move on to adjusting start minutes, the minutes will begin flashing 00:00. Press + or – key to adjust the start minutes of the first timer.
- Press the SET key to confirm and move on to “L1 STOP.” The hours will begin flashing 00:00. Press + or – key to adjust the stop hour of the first timer. Press the SET key to move on to adjusting start minutes, the minutes will begin flashing 00:00. Press + or – key to adjust the stop minutes of the first timer.
- Press the SET key to confirm the first timer and move on to “L2 START.” A second timer can be added during the week (Monday–Friday) using the same method described above. If no additional timer is required, this setting can remain as 00:00.
- Press the SET key to confirm the first timer and move on to “L3 START.” A timer can be added during the weekend (Saturday–Sunday) using the same methods described above.
- Press the SET key to confirm the first timer and move on to “L4 START.” A second timer can be added during the weekend (Saturday–Sunday) using the same methods described above. If no additional timer is required, this setting can remain as 00:00.
Note: This is user preference and settings may need adjustment over time
depending on needs.
Considerations:
- a) Does your power supplier provide an off-peak period of time that you can take advantage of?
- b) At certain times of the day hot water usage will be higher, such as showering. The timer can be set to ensure a sufficient supply of hot water is available for these periods.
- c) Do you want to take advantage of the peak ambient temperatures of midday–on, to assist the Heat Pump for maximum efficiency?
- d) Do you want to limit the Heat Pumps operation during the night to keep noise levels to a minimum?
Off-peak power signal
Note: This appliance must be connected to a power supply providing electricity 24 hours per day. This mode is designed for situations where a meter (eg; smart meter) is constantly supplying electricity but automatically switches depending on peak hours. This is not suitable for situations and meters where tariff or ripple control turns off electricity supply for a period of time (peak.) Please engage your electrician or power provider for further information on the suitability of your electrical devices.
Off-peak power signal operation
- Enter the Standby Mode by pressing the key, only the temperature and time will be displayed.
- Press and hold the + and SET keys for 5 seconds to enter Service Mode.
- “LL” will be displayed. The options are “NO” normally open (default) and “NC” normally closed. You must know if the signal from the switching device or meter is Normally Open or Normally Closed to meet this setting. Press SET key to enter the next setting. 4. “LP” will be displayed. For an Off-peak power signal, press the + or – key to cycle through settings until “02” is displayed. Press the SET key to enter the next setting.
- “LA” will be displayed. This setting is only used when connected to PV solar panels. Press the SET key to enter the next setting.
- “Lb” will be displayed. This setting is only used when connected to PV solar panels. Press the SET key to enter the next setting.
- “LC” will be displayed. This setting is only used when connected to PV solar panels. Press the SET key to enter the next setting.
- “AL” will be displayed. Periodic water sterilization by heating can be selected. The options are “ON” to enable this function (default) or “OFF” to disable the function, press + or – key to cycle through settings. Press SET key to enter the next setting.
- “Ah” will be displayed. The temperature of water sterilization can be adjusted if the above function is “ON,” press the + or – key to cycle through settings between 65–75℃. Press SET key to enter the next setting.
- “Ad” will be displayed. The frequency of the water sterilization can be adjusted by days between 7–30, the default is
- Press the + or – key to cycle through settings. Press the SET key to enter the next setting.
- “AA” will be displayed. This is the maximum working time of the heat pump before auxiliary heating activates. The hours can be adjusted between 5–15, the default is 10. Press + or – key to cycle through settings. Press SET key to enter the next setting.
- “Ct” will be displayed. This setting is used to set the current day of the week, adjustable from 1–7, with Monday being 1 and Sunday being 7. Press + or – key to cycle through settings. Press SET key to enter the next setting.
- “Bt” will be displayed. This is the temperature differential. This setting controls when the heat pump will start operation after the actual temperature drops below the set temperature. The adjustable range is between 5–15℃, the default is 10℃. Press + or –key to cycle through settings. Press the SET key to confirm.
- You will now return to the Standby Mode display. Press the key to enter operational mode.
- Press the MODE key until you are in ECO mode, the icon will be displayed. Validation of operation will be confirmed by the icon being illuminated, confirming a signal between the appliance and off-peak metering.
Note: This mode operates the heat pump only when an off-peak connected signal is detected! Confirm with your power provider the time and duration of this service to ensure suitability for ample heating time and household periods of high hot water usage are sufficient. For example: If the power company provides off-peak metering between 0000-0500, the water heater will operate only during these hours until the set temperature is reached. If the main period of hot water usage is late evening or nighttime and hot water has been drawn off throughout the day without re-heating due to peak time, there may not be sufficient hot water for high-demand fixtures such as showers or baths.
Photovoltaic (PV) solar power signal operation
- Enter the Standby Mode by pressing the key, only the temperature and time will be displayed. _
- Press and hold the + and SET keys for 5 seconds to enter Service Mode.
- “LL” will be displayed. The options are “NO” normally open (default) and “NC” normally closed. You must know if the signal from the switching device or solar controller are Normally Open or Normally Closed to meet this setting. Press SET key to enter the next setting.
- “LP” will be displayed. For PV power signal, press + or – key to cycle through settings until “03” is displayed. Press SET key to enter the next setting.
- “LA” will be displayed. The PV function will work in AUTO mode, the options are “ON” or “OFF”, Press + or – key to cycle through settings. This will switch PV operation mode on when there is a signal in AUTO mode, if using PV, we recommend this setting is “ON.” Press SET key to enter the next setting. _
- “Lb” will be displayed. This setting is used to set the heating temperature when connected to PV solar panels. The adjustable range is between 65-75℃, the default is 65℃. Press + or – key to cycle through settings. Press SET key to enter the next setting.
- “LC” will be displayed. This setting is used to determine the heating source when connected to PV solar panels, a signal is active and there is sufficient solar electricity supply. The options are; “01” The heat pump and electric element will operate simultaneously. Default. “02” The heat pump will operate and if set temperature is not reached within the differential setting, the electric element will assist in heating. “03” Only the electric element will be used for heating. Press + or – key to cycle through settings. Press SET key to enter the next setting. “AL” will be displayed. Periodic water sterilization by heating can be selected. The options are “ON” to enable this function (default) or “OFF” to disable the function, press + or – key to cycle through settings. Press SET key to enter the next setting.
- “Ah” will be displayed. The temperature of water sterilization can be adjusted if the above function is “ON,” press + or – key to cycle through settings between 65–75℃. Press the SET key to enter the next setting.
- “Ad” will be displayed. The frequency of the water sterilization can be adjusted by days between 7–30, the default is 7. Press + or – key to cycle through settings. Press the SET key to enter the next setting.
- “AA” will be displayed. This is the maximum working time of the heat pump before auxiliary heating activates. The hours can be adjusted between 5–15, the default is 10. Press the + or – key to cycle through settings. Press the SET key to enter the next setting.
- “Ct” will be displayed. This setting is used to set the current day of the week, adjustable from 1–7, with Monday being 1 and Sunday being 7. Press + or – key to cycle through settings. Press the SET key to enter the next setting.
- “Bt” will be displayed. This is the temperature differential. This setting controls when the heat pump will start operation after the actual temperature drops below the set temperature. The adjustable range is between 5–15℃, the default is 10℃. Press + or – key to cycle through settings. Press SET key to confirm.
- You will now return to the standby mode display. Press the key to enter operational mode. You can now choose between ECO mode, or AUTO mode if select “ON” in step 5 “LA.” For AUTO mode: Press the MODE key until you are in the mode, and the icon will be displayed. Validation of operation will be confirmed by the PV icon being illuminated, confirming a signal between the appliance and PV solar.
- Note: AUTO mode will operate via the power company’s electrical supply if no signal is detected!
- For ECO mode: Press the MODE key until you are in the mode, and the icon will be displayed. Validation of operation will be confirmed by the PV icon being illuminated, confirming a signal between the appliance and PV solar.
- Note: ECO mode operates the heat pump only when sufficient solar electricity supply is available!
Additional functions
This guide is designed to better explain the controls and operation of additional functions and controls available with your Heat Pump Water Heater.
- Real-time parameter query
- Sterilization (Anti-legionella)
- Stored hot water display
- Demo (display) mode
Parameter query Enter parameter query:
- Enter the Parameter Query Mode with the appliance powered on , The operational working mode will be displayed. _
- Press and hold the MODE and SET keys for 6 seconds to enter Parameter Query.
- The controller will beep 8 times indicating you have entered the real-time parameter query mode. Press and hold the + and – key to scroll through parameters. _
- If no keys are pressed for 6 seconds, the appliance will exit this mode.
Sensor | Code | Definition |
---|---|---|
Ambient temperature | n15 | Real-time ambient temperature reading |
Exhaust temperature | n6 | Real-time exhaust temperature reading |
Suction temperature | n18 | Real-time suction temperature reading |
Evaporator temperature | n4 | Real-time evaporator temperature reading |
Storage tank water temperature | n122 | Real-time water storage tank reading |
Opening of the electronic expansion valve | n123 | Flashing represents 360 steps |
Fan speed | n124 | Blinking represents 580 revolutions |
Sterilization (Anti-legionella)
The sterilization function can be adjusted in the Service Mode. The settings below are relevant for this function: _
- “AL” will be displayed. Periodic water sterilization by heating can be selected. The options are “ON” to enable this function (default) or “OFF” to disable the function, press the + or – key to cycle through settings. Press the SET key to enter the next setting.
- “Ah” will be displayed. The temperature of water sterilization can be adjusted if the above function is “ON,” press + or – key to cycle through settings between 65–75℃. Press the SET key to enter the next setting. _
- “Ad” will be displayed. The frequency of the water sterilization can be adjusted by days between 7–30, the default is 7. Press + or – key to cycle through settings. Press the SET key to enter the next setting.
- Note: If the sterilization function is set to “OFF,” it is recommended that the set temperature be a minimum of 60℃.
Stored hot water display
This display indicates the temperature of water in the storage tank, not the
total volume. The hot water service is a pressurised system and should remain
full of stored water.
Demo (Display) mode
This display mode allows for certain display functions to be operational,
whilst the appliance itself is not operating. This setting should only be used
for display purposes eg; retailers, and wholesalers.
- Enter the Standby Mode by pressing the key, only the temperature and time will be displayed.
- Press and hold the MODE key for 6 seconds to enter Service Mode.
- “A1” represents Operational Mode. “A2” represents display (demo) mode.
- Press + or – key to cycle through Operational or Demo modes.
- Press the key to confirm and exit the selection.
- The default is “A1” Operational Mode.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>