MACTRON WMP2157 21.5 Inch Medical Premium Windows Touch Panel PC User Manual

June 13, 2024
MACTRON

MACTRON WMP2157 21.5 Inch Medical Premium Windows Touch Panel PC

MACTRON-WMP2157-21-5-Inch-Medical-Premium-Windows-Touch-Panel-PC-
PRODUCT

Product Information

The WMP2 1 5 7 is an electronic device with specific product specifications. The illustrations in the user’s manual are for reference only, and the actual product specifications may vary with territories. The information in the user’s manual is subject to change without notice. The manufacturer or reseller shall not be liable for any errors or omissions contained in this manual and shall not be liable for any consequential damages that may result from the performance or use of this manual.

The information in the user’s manual is protected by copyright laws. No part of this manual may be photocopied or reproduced in any form without prior written authorization from the copyright owners. Product names mentioned herein may be trademarks and/or registered trademarks of their respective owners/companies.

The software described in this manual is delivered under a license agreement and may be used or copied only by the terms of the agreement. This product incorporates copyright protection technology that is protected by U.S. patents and other intellectual property rights. Reverse engineering or disassembly is prohibited.

When discarding, do not throw this electronic device into the trash. To minimize pollution and ensure the utmost protection of the global environment, please recycle. For more information on the Waste from Electrical and Electronics Equipment (WEEE) regulations, visit http://ec.europa.eu/environment/waste/weee/index_en.htm.

Product Usage Instructions

Preface Regulations information
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

CAUTION! Any changes or modifications not expressly approved by the guarantee of this device could void the user’s authority to operate the equipment.

Release history

  • Version 1.0
  • Revision note: First released
  • Date: 06.2023

Safety instructions
The following safety precautions will increase the life of the PPC (Panel PC). Follow all precautions and instructions:

  • Do not place this device underneath heavy loads or in an unstable position.
  • Do not use or expose this device around magnetic fields as magnetic interference may affect the performance of the device.
  • Do not expose this device to high levels of direct sunlight, high humidity, or wet conditions.
  • Do not block the air vents to this device or impede the airflow in any way.

Notice

  • The illustrations in this user’s manual are for reference only.

  • Actual product specifications may vary with territories.

  • The information in this user’s manual is subject to change without notice.

  • THE MANUFACTURER OR RESELLER SHALL NOT BE LIABLE FOR ERRORS OR OMISSIONS CONTAINED IN THIS MANUAL AND SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL DAMAGES, WHICH MAY RESULT FROM THE PERFORMANCE OR USE OF THIS MANUAL.

  • The information in this user’s manual is protected by copyright laws. No part of this manual may be photocopied or reproduced in any form without prior written authorization from the copyright owners.

  • Product names mentioned herein may be trademarks and/or registered trademarks of their respective owners/companies.

  • The software described in this manual is delivered under a license agreement. The software may be used or copied only by the terms of the agreement.
    This product incorporates copyright protection technology that is protected by U.S. patents and other intellectual property rights.

  • Reverse engineering or disassembly is prohibited.

  • Do not throw this electronic device into the trash when discarding it. To minimize pollution and ensure the utmost protection of the global environment, please recycle.

  • For more information on the Waste from Electrical and Electronic Equipment (WEEE) regulations, visit http://ec.europa.eu/environment/waste/weee/index_en.htm

Preface

Regulations information

CE compliance
This device is classed as technical information equipment (ITE) in class A and is intended for use in commercial, transport, retailer, public, automation…field.

FCC rules
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

CAUTION!  Any changes or modifications not expressly approved by the guarantee of this device could void the user’s authority to operate the equipment.

Release history

Version Revision note Date
1.0 First released 05.2020

Safety instructions

The following safety precautions will increase the life of the PPC (Panel PC). Follow all Precautions and instructions.

  • Do not place this device underneath heavy loads or in an unstable position.
  • Do not use or expose this device around magnetic fields as magnetic interference may affect the performance of the device.
  • Do not expose this device to high levels of direct sunlight, high humidity, or wet conditions.
  • Do not expose to or use near liquid, rain, or moisture. Never pour any liquid into an opening. This may cause damage or electrical shock.

For CLASS I ME EQUIPMENT
The instructions for use shall include a warning statement to the effect:

WARNING : To avoid the risk of electric shock, this equipment must only be connected to a supply main with protective earth.

  • The user must not modify the internal circuit design. Only the manufacturer may carry out modifications or maintenance work.
  • The unit can be operated at an ambient temperature of max.40°C (104°F). Do not subject it to temperatures below 0°C (32°F) or above 40°C (104°F).

CAUTION!
Incorrectly replacing the RTC battery may damage this PPC. Replace only with the same or equivalent as recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.

Explanation of symbols

On the device, you may find the following symbols (nonrestrictive list ):MACTRON-WMP2157-21-5-Inch-Medical-Premium-Windows-Touch-Panel-PC-FIG-
\(1\)

On the box of the device, you may find the following symbols (nonrestrictive list):MACTRON-WMP2157-21-5-Inch-Medical-Premium-Windows-Touch-Panel-PC-FIG-
\(2\)

Rechargeable Coin Cell Replacement Notice

  1. A hazardous situation might develop by the incorrect polarity connection or replacement of a coin cell on the desired Control PCBA.
  2. The coin cell is intended to be changed only by Service personnel with the use of soldering.
  3. The terminals of the Coin Cell have a clear polarity design and the location for mounting the Coin Cell has been designed to prevent accidental short-circuiting and/or block ventilation.
  4. Seek medical advice immediately if a coin cell has been swallowed.
  5. Store batteries out of reach of children so that they are not accidentally swallowed.

EMC notice

WARNING : Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally.

WARNING : Use of accessories, transducers, and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation.

WARNING : Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the WMP2157, including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result

Model definition

  1. WMP2157 is a Panel PC which is regarded as a Medical Device Data System (MDDS). It is a hardware product that transfer, store, convert formats, and display medical device data. These products do not modify the data or modify the display of the data, and it does not by itself control the functions or parameters of any other medical device.
  2. WMP2157 does not deliver the energy to or extract the energy from the patient.
  3. WMP2157 does not deliver the substances to or extract the substances from the patient.
  4. WMP2157 does not supply sterile or intended to be sterilized by the user, or other applicable microbiological controls.
  5. WMP2157 is not intended to modify the patient environment.
  6. WMP2157 is not intended for use in conjunction with medicines or other medical technologies.
  7. WMP2157 did not hold data critical to patient care.

Notes for this manual

CAUTION!  Important information must be followed for safe operation.

WARNING : Describes hazards or dangers that might result in personal injury or death.

NOTE:  Information for special situations.

Getting to know the basics

Product specification

This User’s Manual provides instructions and illustrations on how to operate this PPC. It is recommended to read this manual carefully before using this PPC.

Physical   characteristic

Dimension 543 x 334 x 49.9 mm
Weight 7.6~8 kg (Net)

(Depends upon the actual shipping product)

Atmospheric pressure| 500 to 1060hPa
Transport /

storage environment

| Temperature: -20°C (-4°F) ~ 60°C (140°F)

Humidity: 20% ~ 80%

Operating

environment

| Temperature: 0°C (32°F) ~ 40°C (104°F)

Humidity: 20% ~ 80% relative humidity, non-condensing

Usage field| Hospital, medical institution
Purpose| Will be used for general purposes in healthcare-related fields as an assisting device for data access and bedside

terminal.

Operator| Is to assist clinicians to access and display medical data at the bedside. It connects to the internal database through the Ethernet and displays the information to

doctors, nurses, patients, and so on. The doctors, nurses, and patients can record data back to the hospital information system.

Product service life| Over 5 years

CPU

Support processor| Intel Whiskey Lake-U platform
Intel Core i5 Processor: i5-8365UE vPro
Intel Core i7 Processor: i7-8665UE vPro (Optional)
Intel Core i3 Processor: i3-8145UE (Optional)
Intel Celeron Processor: 4305UE (Optional)
---|---

Memory

DDR5| 1 x SO-DIMM, DDR5 8GB, 4800MHz (Max.32GB)

1 x SO-DIMM, DDR5, 4800MHz (Max.32GB)

---|---

Power

AC adapter 90 watts, 3 pins (FSP GROUP/ FSP090-RBBM1)
**** CAUTION! MODEL WMP2157 IS DESIGNED TO USE

WITH THE DC INPUT: (19Vdc / 4.74A) ADAPTERS.

****| CAUTION! The adapter watt should follow the default setting or

refer to rating label information.

Storage

SATA-7pin SSD 2.5″, 7mm, Slidable design
M.2 M 2280 1x PCIe or SATA I/F (optional)

**I/O port**

USB 3.0 X 4
LAN (RJ45) X 2 (1st LAN on MB, 2nd LAN via daughter board)
HDMI X 1
Audio jacks X 2 (Mic-in & Line-out)
DC-in X 1
DVI-I-I (Single Link) X 1 (optional)
DB9 (RS232) X 1
Optional Super IO RS232 /422 /485 via IO board – RS232 with power

supply : 5V (standard) &12V (with specific optional board)

Audio

Audio controller

Internal speaker

| Realtek ALC662VDO-GR / ALC888S-VD

2 x 2W

---|---

Display

LCD 21.5″ FHD, 16:9 LED type
Resolution 1920*1080 supported
Touch True-Flat PCAP touch

Webcam

2M HD Webcam Built-in webcam module

Packing List

  • WMP2157  X 1
  • Power cord  X 1
  • Medical adapter  1 x 90W/ 19V

Product Overview

Refer to the following illustration to identify the components on this side of the PPC. Features and configurations vary by model.

NOTE: The product’s color, I/O port, indicator location, and specification will depend upon the actual shipping product.MACTRON-
WMP2157-21-5-Inch-Medical-Premium-Windows-Touch-Panel-PC-FIG-
\(3\) MACTRON-WMP2157-21-5
-Inch-Medical-Premium-Windows-Touch-Panel-PC-FIG- \(4\)

  1. Webcam
  2. 21.5″ FHD LCD (True-Flat PCAP touch)
  3. SSD 2.5″, 7mm
  4. Potential equalization pin (POAG) (Optional)
  5. DVI-D port
  6. COM 3 port (RS232/RS422/RS485)
  7. COM 2 port (RS232/RS422/RS485)
  8. Headphone / Line-out jack
  9. Microphone jack
  10. LAN (RJ45) ports
  11. USB 3.0 ports
  12. HDMI port
  13. COM 1 port (RS232 only)
  14. Power jack (DC-IN)
  15. Power button
  16. Power switch: alternative (Depending on the model)
  17. Magnet

Getting started
Before using the rear I/O connectors, you need to remove the connector cover first.

CAUTION!  For safety reasons, please ensure that the power cord is disconnected before opening the case.

  • Follow the steps (1 2 3) to remove the connector cover.
  • Follow the steps (3 2 1) to install the connector cover.MACTRON-WMP2157-21-5-Inch-Medical-Premium-Windows-Touch-Panel-PC-FIG- \(5\)

How to replace the 2.5″ SSD

  1. If you want to replace the 2.5″ SSD, unscrew the thumbscrew and two screws of the bracket, then remove it.MACTRON-WMP2157-21-5-Inch-Medical-Premium-Windows-Touch-Panel-PC-FIG- \(6\)
  2. Unfasten the two screws (M3*4) and remove the old SSD.
    • As shown, install a new SSD in the bracket and secure it with the two screws (M3*4).
  3. Slide the bracket back into the chassis, then tighten the thumbscrew and two screws.MACTRON-WMP2157-21-5-Inch-Medical-Premium-Windows-Touch-Panel-PC-FIG- \(8\)

CAUTION!  The thumbscrews should be tightened with a tool after both initial installation and subsequent access to the panel.

Powering on the system
Follow the steps (1-3) below to connect the AC adapter to the power jack (DCIN). Press the power switch (4) to turn on the system.MACTRON-
WMP2157-21-5-Inch-Medical-Premium-Windows-Touch-Panel-PC-FIG-
\(10\)
Method   1 : Depending on the model, press the power switch (a or b) to turn on the system.
Method   2 : Press the power switch (c) to turn on the system.

NOTE: Press and hold the power button (a b or c) for 5 seconds to force shutdown.

CAUTION!  Do not use inferior extension cords as this may result in damage to your PPC. The PPC comes with its own AC adapter. Do not use a different adapter to power the PPC and other electrical devices.

NOTE:  The power adapter may become warm to hot when in use. Be sure not to cover the adapter and keep it away from your body.

Potential equalization (Optional)
When potential equalization between the PPC and other devices is required then connect the potential equalization pin (POAG) to the potential equalization terminal of the equipment.MACTRON-WMP2157-21-5-Inch-Medical-
Premium-Windows-Touch-Panel-PC-FIG- \(11\)

Place the cable/cord/wire inside the box and stow the extra cable lengths before closing the cover.

Cleaning the screen
Follow these rules for cleaning the outside and handling your screen on the PPC:

  1. Turn off the system and disconnect all cables.
  2. Use a damp or cleaning cloth, a soft, lint-free cloth with gentle water only, and gently wipe the screen surface.
  3. Do not spray liquid directly on the screen.

CAUTION! Do not use or spray water and strong solvents such as alcohol, benzine, thinner, or any other solvent.

VESA mounting to the wall (Optional)
Standard VESA to let the user guide the wall/arm mount kit you bought to install it.MACTRON-WMP2157-21-5-Inch-Medical-Premium-Windows-Touch-Panel-PC-
FIG- \(12\)

NOTE: Panel PC can be mounted on a wall using a VESA-compatible 100mm x 100mm wall/arm bracket, a maximum loading capacity > 10 kg, and only for mounting at heights 2 m.

How to use the touch panel (Optional)
The touch panel brings digital life for an easy touch experience. Experience the ease of managing your digital life with a few touches. Your touch functions like a mouse device and all you need to interact with the touch panel.

  1. Touch = left-click on the mouse
  2. Touch and hold = Right-click on the mouseMACTRON-WMP2157-21-5-Inch-Medical-Premium-Windows-Touch-Panel-PC-FIG- \(13\)

CAUTION! No matter the PPC with or without a stand, the usage angle can’t be less than 90 degrees.

BIOS setup

About BIOS setup
The default BIOS (Basic Input/ Output System) is already properly configured and optimized, there is normally no need to run this utility.

When to use BIOS setup?
You may need to run the BIOS Setup when:

  • An error message appears on the screen during the system booting up and is requested to run SETUP.
  • You want to change the default settings for customized features.
  • You want to reload the default BIOS settings.

CAUTION!  We strongly recommend that you change the BIOS settings only with the help of trained service personnel.

How to run BIOS setup?
To run the BIOS setup Utility, turn on the PPC and press the [Del] or [F2] key during the POST procedure. If the message disappears before you respond and you still wish to enter setup, either restart the system by turning it OFF and ON or simultaneously pressing [Ctrl]+[Alt]+[Del] keys to restart. The setup function only can be invoked by pressing the [Del] or [F2] key during POST provides an approach to change some settings and configurations the user prefers, and the changed values will save in the NVRAM and will take effect after the system reboot. Press the [F7] key for the Boot Menu.

When OS support is Windows 10:

  1. Click the Start menu  and select Settings.
  2. Select Update and Security.
  3. Click Recovery
  4. Under Advanced Startup, click Restart now.
  5. The system will restart and show the Windows 10 boot menu.
  6. Select Troubleshoot.
  7. Choose Advanced options.
  8. Select UEFI Firmware Settings.
  9. Click Restart to restart the system and enter UEFI (BIOS).

Manufacturer Information
MACTRON GROUP CO., LTD. Address : 2F., No.86, Xinhu 1st Road, Neihu District, Taipei, Taiwan Phone : +886-2-2795-1668 Website : https://www.mactrongroup.com/

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)