Haier HSU-07HC03 Split Type Room Air Conditioner Instruction Manual

June 13, 2024
Haier

Haier-logo

Haier HSU-07HC03 Split Type Room Air Conditioner

Product Information

  • Edition: 2005/11/18

Model Numbers:

  • HSU-07HC03/R2, HSU-09HD03/R2, HSU-09HC03/R2,
  • HSU-12HD03/R2, HSU-12HC03/R2, HSU-14HB03/R2, HSU-07HE03/R2,
  • HSU-18HB03/R2, HSU-09HE03/R2, HSU-22HC03/R2, HSU-12HE03/R2,
  • HSU-22HD03/R2, HSU-07HD03/R2, HSU-22HB03/R2

Cautions

  • The machine is adaptive in the following situations:
    • Applicable ambient temperature range for cooling:
    • Indoor Maximum: 32oC (D.B) / 23oC (W.B)
    • Indoor Minimum: 18oC (D.B) / 14oC (W.B)
    • Outdoor Maximum: 43oC (D.B)
    • Outdoor Minimum: 18oC (D.B)
    • Applicable ambient temperature range for heating:
    • Indoor Maximum: 27oC (D.B)
    • Indoor Minimum: 15oC (D.B)
    • Outdoor Maximum: 24oC (D.B) / 18oC (W.B)
    • Outdoor Minimum: -7oC (D.B) / -8oC (W.B)
  • If the supply cord is damaged, it must be replaced by the manufacturer its service agent, or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F.
  • If the fuse on the PC board is broken, please change it to the type of T. 3.15A/250V.
  • The distance between the indoor unit and the floor should be more than 2m.
  • The wiring method should be in line with the local wiring standard.
  • After installation, the power plug should be easily reached.
  • The waste battery should be disposed of properly.
  • The appliance is not intended to be used by young children or infirm persons without supervision.
  • Youth children should be supervised to ensure that they do not play with the appliance.
  • The appliance must be installed on a strong enough supporter.
  • The wiring diagram is attached to the machine.

Parts and Functions

Indoor Unit

  • Inlet grille
  • Air filter
  • Vertical flap – Use a remote controller to adjust up and down airflow. (Don’t adjust it manually.)
  • Power indicator – Lights up when the unit starts.
  • Timer mode indicator – Lights up when Timer operation is selected.
  • Test running switch (manual) – Used only for test running in cooling when room temp. is below 16oC. Don’t use it in normal operation.
  • Emergency switch (manual) – Used when the remote controller is lost or defective. The unit will run temporarily.
  • Remote signal receiver – A beeping sound is generated when a signal from the remote controller is received.
  • Operation mode indicator – Lights up during compressor running.

Outdoor Unit

  • OUTLET
  • INLET
  • CONNECTING PIPING AND ELECTRICAL WIRING
  • DRAIN HOSE

Product Usage Instructions

  1. Read the operation manual before using the air conditioner.
  2. Ensure that the ambient temperature is within the specified range for cooling or heating.
  3. If the supply cord is damaged, contact the manufacturer or a qualified person for replacement.
  4. If the fuse on the PC board is broken, replace it with a T. 3.15A/250V fuse.
  5. Ensure that the distance between the indoor unit and the floor is more than 2m.
  6. Follow the local wiring standard for proper installation.
  7. After installation, make sure the power plug is easily accessible.
  8. Dispose of waste batteries properly.
  9. Do not allow young children or infirm persons to use the appliance without supervision.
  10. Supervise young children to ensure they do not play with the appliance.
  11. Ensure the appliance is installed on a strong enough supporter.

Cautions

The machine is adaptive in the following situation

  1. Applicable ambient temperature range:

Cooling

| Indoor| Maximum: D.B / W.B

Minimum: D.B / W.B

| 32oC/23oC

18oC/14oC

---|---|---|---
Outdoor| Maximum: D.B

Minimum: D.B

| 43oC/26oC

18oC

Heating

| Indoor| Maximum: D.B

Minimum: D.B

| 27oC

15oC

Outdoor| Maximum: D.B / W.B

Minimum: D.B / W.B

| 24oC/18oC

-7oC/-8oC

  1. If the supply cord is damaged, it must be replaced by the manufacturer its service agent or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F
  2. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.
  3. The distance between the indoor unit and the floor should be more than 2m.
  4. The wiring method should be in line with the local wiring standard.
  5. After installation, the power plug should be easily reached.
  6. The waste battery should be disposed of properly.
  7. The appliance is not intended to be used by young children or infirm persons without supervision.
  8. Young children should be supervised to ensure that they do not play with the appliance.
  9. The appliance must be installed on a strong enough supporter.
  10. The wiring diagram is attached to the machine.

Parts and Functions

Indoor Unit

Haier-HSU-07HC03-Split-Type-Room-Air-Conditioner-fig-
\(1\)

Actual inlet grille may vary from the one shown in the manual according to the product purchased

Outdoor Unit

Haier-HSU-07HC03-Split-Type-Room-Air-Conditioner-fig-
\(2\)

  1. OUTLET
  2. INLET
  3. CONNECTING PIPING AND ELECTRICAL WIRING
  4. DRAIN HOSE
Operation

Buttons and display of the remote controller. If the unit that you purchased has a healthy function, the Remote controller should like the following figure:

  1. Mode display

    • AUTO
    • COOL
    • DRY
    • HEAT
    • FAN
  2. SWING display

  3. FAN SPEED display

  4. SLEEP display

  5. LOCK display

  6. SIGNAL SENDING

  7. TIMER OFF display

  8. TIMER ON display

  9. CLOCK display

  10. TEMP display

  11. POWER ON/OFF Used for unit start and stop.

  12. MODE
    Used to select AUTO run, COOL, DRY, HEAT, and FAN operation

  13. FAN
    Used to select fan speed LO, MED, HI, AUTO

  14. HOUR
    Used to set clock and timer settings.

  15. SWING
    Used to set auto fan direction.

  16. SLEEP
    Used to select sleep mode.

  17. LOCK
    Used to lock buttons and LCD display.

  18. TEMP.
    Used to select your desired temp.

  19. SET
    Used to confirm timer and clock settings.

  20. TIMER
    Used to select TIMER ON, TIMER OFF, TIMER ON-OFF

  21. CLOCK
    Used to set the correct time

  22. RESET
    Used to reset the controller back to normal condition.

  23. HEALTH
    Used to set healthy operation

Clock set

  • When the unit is started for the first time and after replacing the batteries in the remote controller, the  clock should be adjusted as follows:
  • Press the CLOCK button, and “AM” or “PM” flashes.
  • Press or to set the correct time. Each press will increase or decrease by 1 minute. If the button is kept depressed, time will change quickly.
  • After the time setting is confirmed, press SET, “AM “and “PM” stop flashing, while the clock starts working.
  • NOTE: Cooling units do not have displays and functions related to heating.

Hints
After replacing it with new batteries, the remote controller will conduct a self-check, displaying all information on the LCD. Then, it will become normal.

If the unit that you purchased has a healthy function, the Remote controller should like the following figure:

Haier-HSU-07HC03-Split-Type-Room-Air-Conditioner-fig-
\(10\)

  1. Mode display

    • AUTO
    • COOL
    • DRY
    • HEAT
    • FAN
  2. SWING display

  3. FAN SPEED display

  4. SLEEP display

  5. LOCK display

  6. SIGNAL SENDING

  7. TIMER OFF display

  8. TIMER ON display

  9. CLOCK display

  10. TEMP display

  11. POWER ON/OFF
    Used for unit start and stop.

  12. MODE
    Used to select AUTO run, COOL, DRY, HEAT and FAN operation

  13. FAN
    Used to select fan speed LO, MED, HI, AUTO

  14. HOUR
    Used to set clock and timer setting.

  15. SWING
    Used to set auto fan direction.

  16. SLEEP
    Used to select sleep mode.

  17. LOCK
    Used to lock buttons and LCD display.

  18. TEMP.
    Used to select your desired temp.

  19. SET
    Used to confirm timer and clock settings.

  20. TIMER
    Used to select TIMER ON, TIMER OFF, TIMER ON-OFF

  21. CLOCK
    Used to set correct time

  22. RESET
    Used to reset the controller back to normal condition.

BRIEF INTRODUCTION TO HEALTH OPERATION
The anion generator in the air conditioner can generate a lot of anion to effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room.

NOTE:
Cooling-only units do not have displays and functions related to heating.

Hints
After replacing it with new batteries, the remote controller will conduct a self-check, displaying all information on the LCD. Then, it will become normal.

Remote controller’s operation

  • When in use, put the signal transmission head directly to the receiver hole on the indoor unit.
  • The distance between the signal transmission head and the receiver hole should be within 7m without any obstacles as well.
  • Don’t throw the controller, prevent it from being damaged.
  • When an electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals so the distance to the indoor unit should be shorter.

Loading of the battery

  • Load the batteries as illustrated. 2 R-03 batteries, resetting key (cylinder)
  • Remove the battery cover:
  • Slightly press “ ” and push down the cover.

Load the battery:
Be sure that the loading is in line with the” + “/”-” pole request as illustrated.

Put on the cover again

Confirmation indicator:
In disorientation, reload the batteries or load the new batteries after 6mins.

Note:

  • Use two new same-typed batteries when loading.
  • If the remote controller can’t run normally or doesn’t work at all, use a sharp pointed item to press the reset key.

Hint:

  • Remove the batteries in case the unit won’t be in use for a long period.
  • If there are any displays after taking out just need to press the reset key.

Power failure resume(please set and apply as necessary)
If a sudden power failure occurs, the unit will resume its original operation when power is supplied again.

Note:
When sudden power failure happens during unit operation in power failure resume mode, if the air conditioner is not desired for use in a long period, please shut off the power supply in case that the unit automatically resume operation when power is re-supplied, or press ON/OFF to turn off the unit when power resumes.

Autorun, Fan operation
Enjoy yourself with just a gentle press.

  1. Unit start

    • Press the ON/OFF button, and the unit starts.
    • Previous operation status appears on display. (Not Timer setting)
    • The power indicator on the indoor unit lights up.
  2. Select operation mode
    Press the MODE button. For each press, the operation mode changes as follows:

  3. The unit will run in the selected mode.

  4. Stop display at “ ” AUTO or ” “FAN.

  5. FAN
    Press the FAN button. For each press, the fan speed changes as follows:

    • The unit will run at the selected fan speed. Note: AUTO is not available in FAN mode.
  6. Unit stop

    • Press the ON/OFF button.
    • Only time remains on LCD.
    • All indicators on the indoor unit go out. The vertical flap closed automatically.Haier-HSU-07HC03-Split-Type-Room-Air-Conditioner-fig- \(19\)

Hints
The remote controller can memorize settings in each operation mode. To run it next time just select the operation mode and it will start with the previous setting.

No reelecting is needed. (TIMER ON/OFF needs reelecting)

Cautions:

On only one unit, the heating mode is not available, After replacing the batteries, press ON/OFF, and the display becomes as follows:

  • Operation mode: AUTO, Temp. No
  • Timer mode: No, Fan speed: AUTO

Note:
The above information is the explanation of the displayed information and therefore varies with those displayed in actual operation.

COOL, HEAT, and DRY operation

Recommendations:

  • Use COOL in summer.
  • Use HEAT in winter Use DRY in spring, autumn, and in damp climates.
  1. Unit start
    Press the ON/OFF button, and the unit starts.
    Previous operation status appears on display. (Not Timer setting) The power indicator on the indoor unit lights up.

  2. Select operation mode
    Press the MODE button. For each press, the operation mode changes as follows:
    The unit will run in operation mode displayed on LCD. Stop display at your desired mode.

  3. Select temp. setting
    Press the TEMR button.

  4. Every time the button is pressed, temp. setting increases 1oC

  5. Every time the button is pressed, temp. setting decreases 1oC Unit will start running to reach the temp. setting on LCD.

  6. Fan speed selection
    Press the FAN button. For each press, the fan speed changes as follows:
    The unit runs at the speed displayed on LCD.
    In DRY mode, when room temperature becomes lower than temp.setting+2oC, unit will run intermittently at LOW speed regardless of the FAN setting.Haier-
HSU-07HC03-Split-Type-Room-Air-Conditioner-fig- \(22\)
    Hints
    On the cooling-only unit, the heating mode is not available. The remote controller can memorize each operation status. When starting it next time, just press the ON/OFF button and the unit will run in the previous status.

  7. Airflow direction adjustment
    After the operation mode is selected, the vertical flap will open automatically according to the mode. Referring to the Fig.Haier-HSU-07HC03
-Split-Type-Room-Air-Conditioner-fig- \(24\)

    • Up and down (Use remote controller)
      Press the SWING button, vertical flap will move within the range shown in Fig. Press the SWING button to stop it at a fixed position.
      Cautions:
      It is advisable not to keep the vertical flap at the downward position for a long time in COOL or DRY mode, otherwise, condensate water might occur.

    • Left and right airflow adjustment (manual)
      Move the horizontal blade by a knob on the air conditioner to adjust the left and right direction referring to Fig.
      Cautions:
      When humidity is high, condensate water might occur at the air outlet if all horizontal louvers are adjusted to the left or right.

  8. Unit stop

    • Press the ON/OFF button.
    • Only time remains on LCD.
    • All indicators on the indoor unit go out. The vertical flap closes automatically.

Cautions:
Unit won’t restart until 3 minutes have elapsed, due to system protection. HEAT mode is not available on a cooling-only unit.

Hints

  • As cold air flows downward in COOL mode, adjusting airflow horizontally will be much more helpful for better air circulation.
  • As warm air flows upward in HEAT mode, adjusting airflow downward will be much more helpful for better air circulation.
  • Be careful not to catch a cold when cold air blows downward.
  • It is harmful to your health in summer to go frequently in and out of places where temp. the difference is above 7oC. Temp. difference of 3-5oC will remove your fatigue.
  • More than this, the unit’s load can be reduced and power consumption cut down as well. So, you’d better set a temp. difference of 3-5oC between indoor and outdoor temp. in COOL mode.

TIMER Operation

Set the Clock correctly before starting the Timer operation
You can let the unit start or stop automatically at the following times: Before you wake up in the morning, or get back from outside or after you fall asleep at night.

TIMER ON/OFF

  1. After the unit starts, select your desired operation mode.
    Operation mode will be displayed on LCD.
    The power indicator on the indoor unit lights up.

  2. TIMER mode selection
    Press the TIMER button to change the TIMER mode.
    Every time the button is pressed, the display changes as follows:Haier-HSU-
07HC03-Split-Type-Room-Air-Conditioner-fig- \(27\)
    Select your desired TIMER mode (TIMER ON or TIMER OFF) ON or OFF will flash.

  3. (3)Timer setting

    • Press the HOUR / button.
    • Every time the button is pressed, time increases by 10 min. If the button is kept depressed, time will change quickly.
    • Every time the button is pressed, time decreases by 10 min. If the button is kept depressed, time will change quickly. Time will be shown on LCD. It can be adjusted within 24 hours.
  4. Confirming your setting

    • After setting the correct time, press the SET button to confirm, that “ON” or “OFF” stops flashing
    • Time displayed: Unit starts or stops at x hour x min. (TIMER ON or TIMER OFF).
    • The timer mode indicator on the indoor unit lights up.Haier-HSU-07HC03-Split-Type-Room-Air-Conditioner-fig- \(28\)

To cancel the TIMER mode
Just press the TIMER button several times until TIMER mode disappears.

Hints
After replacing batteries or a power failure happens, the Time setting should be reset. The remote controller possesses a memory function, when using TIMER mode next time, just press the SET button after the mode selecting if the timer setting is the same as the previous one.

TIMER ON-OFF

  1. After the unit starts, select your desired operation mode Operation mode will be displayed on the LCD.
    The power indicator on the indoor unit lights up.

  2. Press the TIMER button to change TIMER mode. Every time the button is pressed, the display changes as follows:Haier-HSU-07HC03-Split-Type-Room-Air-Conditioner-fig- \(29\)
    Select TIMER ON-OFF. “ON” will flash.

  3. Time setting for TIMER ON

    • Press HOUR button.
    • Every time the button is pressed, time increases 10 min.
    • If button is kept depressed, time will change quickly.
    • Every time the button is pressed, time decreases 10 min.
    • If button is kept depressed, time will change quickly.
    • Time will be shown on LCD.
    • It can be adjusted within 24 hours.
    • AM refers to morning and PM to afternoon
  4. Time confirming for TIMER ON

    • After time setting, press TIMER button to confirm.
    • “ON” stops blinking, While “OFF” starts blinking.
    • Time displayed: Unit starts at x hour x min.
  5. Time setting for TIMER OFF
    Follow the same procedures in “Time setting for TIMER ON”.

  6. Time confirming for TIMER OFF
    After time setting, press SET button to confirm, “OFF” stops flashing Time displayed: Unit stops at X hour X min.Haier-HSU-07HC03-Split-Type-Room-Air-
Conditioner-fig- \(30\)

To cancel TIMER mode
Just press TIMER button several times until TIMER mode disappears.

Emergency operation and test operation

Emergency Operation:

  • Carry out this operation only when the remote controller is defective or lost.
  • When the emergency operation switch is pressed, a” Pi “sound starts once, which means the start of this operation.
  • In this operation, it is not possible to change the settings of temperature and air flow speed, it is also impossible to do an operation by the timer.
  • Follow the requirements below.

Room temperature| Designated temperature| Timer mode| Air flow speed| Operation mode
---|---|---|---|---
More than 23oC| 26oC| CONTINUOUS| AUTO| COOL
Less than 23oC| 23oC| CONTINUOUS| AUTO| HEAT

  • If an air conditioner is a model for both cooling and heating.
  • Cooling when the room temperature at the start of operation is above 23oC.
  • Heating when the room temperature at the start of operation is below 23oC

Test operation:

  • Use this switch in the test operation when the room temperature is less 16oC, do not use it in the normal operation.
  • Continue to press the test operation switch for more than 5 seconds. After you hear the “Pi” sound twice, release your finger from the switch, the cooling operation starts with the air flow speed setting “Hi”.

Removal of the restriction of emergency or test operation:

  • Press the emergency operation switch, or manipulate it through the remote controller, and a “Pi” sound causes the restriction of emergency or test operation to be removed.
  • When the remote controller is manipulated for the removal, then the selected operation by the remote controller.

Comfortable SLEEP
Before going to bed at night, you can simply press the SLEEP button and the unit will bring you a sound sleep in the selected mode.

In COOL mode
One hour after SLEEP mode starts, temp. will become 1oC higher than temp. setting. After running for another 1 hour, temp. rises by 1oC further. Unit will run for 6 hours and then stop automatically. Temp. is higher than temp. setting so that room temp. won’t be too low for your sleep. (As shown in Fig.l)

In HEAT mode
One hour after SLEEP mode starts, temp. will become 2oC lower than temp. setting. After running for another 1 hour, temp. decreases by 2oC further. Unit will run for 3 hours at this temp. then increases another 1oC and stops automatically 3 hours later. Temp. is lower than temp. setting so that room temp. won’t be too high for your sleep. (As shown in Fig .2)

Power Failure Resume Function
If the unit is started for the first time, the compressor will not start running unless 3 minutes have elapsed. When the power resumes after a power failure, the unit will run automatically, the power indicator lights up, and 3 minutes later the compressor starts running with the indicator lighting up.

Note:
In AUTO mode, the unit will run in SLEEP function according to the operation mode. In FAN mode, comfortable sleep is not available.

Maintenance

Different models have different appearance

Haier-HSU-07HC03-Split-Type-Room-Air-Conditioner-fig-
\(36\)

  1. Open inlet grille by pulling it upward.

  2. Remove air filter Push up the filter’s center tab slightly until it is caesura of the stopper. Remove it by pulling down.

  3. Clean the filter
    Use a vacuum cleaner to remove dust,or wash the filter with water. After washing, dry the filter completely in the shade.

  4. Attach the filter
    Attach filter behind the stopper so that the “Front” indication is facing to the front. Make sure that it is completely behind the stopper, otherwise problems might occur.

  5. Close the inlet grille.

Better use of air conditioner

Haier-HSU-07HC03-Split-Type-Room-Air-Conditioner-fig-
\(41\)

Never fail to observe the followings

Haier-HSU-07HC03-Split-Type-Room-Air-Conditioner-fig-
\(42\)

Trouble shooting

Before asking for service, check the following first.

| Phenomenon| Cause or check points
---|---|---

Normal Performance inspection

| The system does not restart immediately.| When unit is stopped, it won’t restart immediately until 3 minutes have elapsed to protect the system.

When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the air conditioner.

Noise is heard

| During unit operation or at stop, a swishing or gurgling noise may be heard. At first 2-3 minutes after unit start, this noise is more noticeable. (This noise is generated by refrigerant flowing in the system.)

During unit operation, a cracking noise may be heard. This noise is generated by the casing expanding or shrinking because of temperature changes

Should there be a big noise from air flow in unit operation, air filter may be too dirty.

Smells are generated.

| This is because the system circulates smells

from the interior air such as the smell of furniture, cigarettes.

Mist or steam are blown out.

| During COOL or DRY operation, indoor unit may blow out mist. This is due to the sudden cooling of indoor air.

Multiple check

| Does not work at all.

| Is power plug inserted? Is there a power failure? Is fuse blown out?
| Poor cooling

| Is the air filter dirty? Normally it should be cleaned every 15 days.

Are there any obstacles before inlet and outlet? Is temperature set correctly?

Are there some doors or windows left open? Is there any direct sunlight through the window during the cooling operation?(Use curtain)

Are there too much heat sources or too many people in the room during cooling operation?

Application temp. range of air conditioner -7oC~43oC.

Including electrically controlled function introduction of air conditioners:

Introduction of electrically controlled functions

Automatic running (applicable to fan-coil model)
When the running mode is turned to automation after starting the system, the system will first determine the running mode according to the current room temperature and then will run according to the determined mode. Tr in the following selection conditions means room temperature, Ts means setting temperature, Tp means temperature of indoor coil pipe

  • Tr>23°C
    • running cooling mode Ts=26°C
  • Tr~23°C
  • running heating mode Ts=23°C

After turning to the automation mode, the running mode can be switched between refrigerating mode, fan mode and heating mode according to the change of the indoor ambient temperature. But the automatic conversion between refrigerating mode and heating mode must be conducted after 15 minutes.

Indoor temperature control

Haier-HSU-07HC03-Split-Type-Room-Air-Conditioner-fig-
\(48\)

Dehumidification running
The compressor, outdoor fan and indoor fan will run as per the following working pattern so as to realize the cooling running of dehumidification:

  1. Tr> Ts+2°C, compressor, outdoor fan run continuously, indoor fan runs as per setting wind speed (State 1);
  2. Ts+2 ·c ?:Tr?:Ts, compressor, outdoor fan run intermittently with 10 minutes ON, 6 minutes OFF. (Compressor and outdoor fan are synchronous) indoor fan runs in fixed lower wind speed, and will cease at the stand-by time of3 minutes (State 2)
  3. Tr <Ts, compressor, outdoor fan ceases, indoor fan runs in lower wind speed. (State 3)

Warm start (preventing cold wind when heating running begins, applicable to fan-coil model)) When heating running begins, indoor fan will conduct the following fan control:

  1. If the temperature of indoor coil pipe is ;=:: 28°C, start lower wind speed;
  2. If the temperature of indoor coil pipe is ;=:: 38 ·c or the running time of compressor;=:: 4 minutes, turn to setting wind speed.

Control of indoor fan under heating OFF state (applicable to fan-coil model)
Under heating state, the compressor will cease; if the indoor coil pipe s temperature Tp;,::23 ·c, indoor fan will run in lower wind speed.

Defrosting control (applicable to fan-coil model)

  1. Defrosting beginning condition:
    • After the state of Tp-Tr< ·c is continued for 5 minutes, the accumulated running time of the compressor exceeds 45 minutes, the continuous running time of the compressor exceeds 20 minutes;
    • The accumulated running time of the compressor exceeds 3 hours, the continuous running time of the compressor exceeds 20 minutes, indoor unit s Tp < ·c ;
    • The continuous running time of the compressor exceeds 20 minutes, the temperature of indoor coil pipe decreases 1 ·c every 6 minutes, which lasts for more than 3 times, indoor unit s Tp < °C;
    • When the indoor unit is in the state of overload protection and the outdoor unit ceases, when the rerunning time of outdoor unit exceeds 10 minutes, the accumulated running time of the compressor exceeds 45 minutes, the continuous running time of the compressor is over 20 minutes, and Tp < ·c . Defrosting will begin if one of the above conditions is met.
  2. Defrosting finishing condition:
    If the defrosting time exceeds 9 minutes, the original heating state will be resumed;
    Note: Sequence of defrosting actions:

Freezing prevention function
Under refrigerating and dehumidifying state, the air conditioner will control the outdoor fan as per the temperature Tp of the indoor coil pipe according to the following conditions:Haier-HSU-07HC03-Split-Type-Room-Air-Conditioner-
fig- \(51\)

3 minutes stand-by time
When the compressor ceases due to the sensor OFF, unit On or OFF or fault, it will maintain pause for 3 minutes.

Overload protection during heating running
Temperature protection of indoor coil pipe: Under heating state, the air conditioner will control the running of the fan as per the temperature Tp of the indoor coil pipe and according to the following conditions:

  • 56°C< S;Tp, outdoor fan ceases; Tp< S;52°C, outdoor fan resumes; the time from ceasing to resuming is about 45 seconds;
  • 72 ·c< S; Tp, outdoor fan of compressor ceases after 5 seconds; Tp< S; 64 ·c, compressor resumes after 3 minutes.

Compensatory function of power failure
If the unit is suddenly off during running due to power failure, or closed for maintenance or troubleshooting, it will restart to run after the power resumes with the original condition before the unit is off

Note:

  1. Function setting: Pressing the SLEEP button on the remote control unit for 10 times until hearing 4 sounds from the buzzer on the panel.
  2. Memory content: Running mode, setting wind speed, setting temperature, sleep state, flap state.
  3. Cancellation of function: Pressing the SLEEP button on the remote control unit for 10 times until hearing 2 sounds from the buzzer on the panel.

Trial run function
When the air conditioner is in OFF state, press the emergency switch for 5 seconds till hearing 2 sounds of click from the buzzer, then the air conditioner will turn to the trial run state. The unit will run in the refrigerating mode and the indoor fan will run in high wind speed mode.

Emergency running mode
When the air conditioner is in stand-by state, press the emergency switch till hearing a sound from the buzzer, then the air conditioner will turn to the emergency run state. The rules of emergency run are as follows:

  • Tr> 23 °C, running refrigerating mode, Ts = 26 °C;
  • Tr< 23 °C, running heating mode, Ts = 2 = °C.

Temperature compensation
There is the function of automatic temperature compensation when heating, with heating temperature setting = Ts(remote setting) + 4 °C.

Sleeping function

  • After setting the sleeping function, the refrigerating mode and dehumidification mode will run as per the following rules:Haier-HSU-07HC03-Split-Type-Room-Air-Conditioner-fig- \(52\)
  • After setting the sleeping function, the heating mode will run as per the following rules:Haier-HSU-07HC03-Split-Type-Room-Air-Conditioner-fig- \(53\)
    As shown and de in the above diagram, after running for 1 hm r under refrigera ting mode hum ification mode the setting ternp erature will increase 1 °C; after another 1 hour, it will increase 1 °C again, and after 6 hours, it will cease; after running for 1 hour under heating mode, the setting temperature will decrease 2 °C, after another 1 hour, it will decrease the 2 °C again, and after 3 hours, it will increase 1 °C, and after other 3 hours, it will cease.

Trouble displaying method

  • The temperature sensor of coil pipe of indoor unit is in short circuit or broken circuit: the timing indicator of indoor unit is on, the power indicator is flickered in 1 Hz;
  • The room temperature sensor of indoor unit is in short circuit or broken circuit: the timing indicator of indoor unit is off, the power indicator is flickered in 1 Hz;
  • The motor of indoor unit has nor backfeed of signal, the power indicator of indoor unit and running indicator are flickered twice, then the power indicator, running indicator and timing indicator are all flickered for 1 second, then repeating the cycle.

For the abnormal phenomenon occurred, please conduct trouble analysis and troubleshooting according to the following table:

No Reason of trouble Phenomena Remarks
1 The sensor of indoor ambient temperature is in short circuit or broken
circuit The compressor indictor and timing    indicator extinguish, and
the running indicator flickers
2 The temperature sensor of indoor coil pipe is in short circuit or broken
circuit The compressor indictor and timing indicator are on, and the running
indicator flickers
3 Theindoormotoris damagedo,r the computer board is damaged The power

indicator and running indicator of indoor unit flicker twice, thepower indicator, running indicator and timing indicator flicker togetherfor 1 second,then repeating the cycle.| The motorhasno signal feedback of Hall unit

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals