ROLO
CENTRAL HEATING INSTALLATION INSTRUCTIONS
Determine Correct Orientation for Installation Removable stickers on the
product will indicate which way up you need to install, as follows:
– TOP if C/Heating – (Vertical Bar Orientation)
– TOP if C/Heating – (Horizontal Bar)
In CENTRAL HEATING installation you will require the threaded plug found in
the bracket box and an 8 mm Allen Key (not supplied). This threaded plug will
act as a flow diverter, forcing the flow of the water up and over inside the
radiator, to achieve even heat distribution of all bars.
Where to install the threaded plug
When the product is to be mounted portrait the threaded plug will need to be
screwed in on the FLOW side. When portrait you can choose to have the flow on
the left or right-hand side. IMAGE A: The plug is screwed in on the left-hand
side, where the flow is coming in. Where to install the threaded plug
When the product is to be mounted landscape the threaded plug needs to be
screwed into the left-hand side of the radiator.
IMAGE B: This will force the water efficiently around the radiator whether the
flow is coming from the left or the right-hand side.
Fully Balance System
The radiator has a big capacity, before commissioning bleeds the heating system and checks the pressure in the system![TERMA 2736BTU Rolo Room Radiator
- fig](https://manuals.plus/wp-content/uploads/2022/09/TERMA-2736BTU-Rolo- Room-Radiator-fig.png)