BLISS piave1700 Massage Bathtub User Manual
- June 13, 2024
- BLISS
Table of Contents
- BLISS piave1700 Massage Bathtub
- Installation & User Manual
- Suggested Tools For Installation
- Installation
- Product Description
- TouchPad Usage Instructions
- Electric Parameters
- Panel function description
- Usage
- Troubleshooting
- Cleaning & Maintenance
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BLISS piave1700 Massage Bathtub
Product Information
- Massage Bathtub BLISS
- Dimensions: 1700 x 800 x 600mm
- Version: 202308.8
Installation & User Manual
Your massage bathtub includes a detailed Installation & User Manual. Follow all instructions in the Installation & User Manual closely.
Warning! Improper installation, usage, or maintenance can lead to loss of warranty, injury, or property damage.
Spa Bath to be installed in accordance with BCA and local regulatory standards by qualified persons only. An isolation switch is recommended.
Electrical installation must comply with AS:3000-Electrical Wiring Rules.
Suggested Tools For Installation
The following tools are required to install your bathtub:
- Water level
- Sealant
- Adjustable spanner or spanner in required sizes
- Screw driver
- PTFE sealing tape or suitable substitute
Product Description
By default, the massage bathtub is equipped with the following features:
- Water jets
- Suction
- Touch control pad
- Regulator
- Air jets
- Underwater light
TouchPad Usage Instructions
-
Press this button, the system will start, the indicator light will be on; Press this button again, the system will be closed and the indicator light will be off.
-
Water pump function: This function is controlled by the water level and will not be activated until the system detects the water.
The indicator light will indicate when the pump is started. It will be automatically turned off when there is no water. -
Windpump function: It is not controlled by the water level. It also operates for a maximum of 30 minutes.
-
Underwater lamp function: Press this button to turn on/off the underwater lamp.
Electric Parameters
- Rated Voltage: 220 – 240 V
- Rated Frequency: 50 / 60 Hz
- Rated Maximum Power: 800 W
- Rated Maximum Current: 3.6 A
Panel Function Description
- Windpump
- Water pump
- Underwater lamp
- Power switch
Installation
Your massage bathtub includes a detailed Installation & User Manual. Follow
all instructions in the Installation & User Manual closely.
Please record your Spa Bath Serial Number here.
If you have any questions regarding installation, maintenance or usage of your
product please contact the seller for detailed information.
Please Note: If you need any service please contact ENTREND DESIGN
TEL: (02) 96006166
Installation & User Manual
Warning! Risk of fire, electric shock and water leakage.
Your massage bathtub includes a detailed Installed Installation & User Manual.
Follow all instructions in the Installation & User Manual closely.
Warning! In-proper installation, usage or maintenance can lead to loss of
warranty, injury or property damage.
Spa Bath to be installed in accordance with BCA and local regulatory standards
by qualified persons only. An isolation switch is recommended.
Electrical installation must comply with AS:3000-Electrical Wiring Rules.
Suggested Tools For Installation
The following tools are required to install your bathtubs. Additional tools may be required depending on the installation circumstances.
- Water level
- Sealant
- Adjustable spanner or spanner in required sizes
- Screw driver
- PTFE sealing tape or suitable substitute
Installation
- No silicon onto top and around the spa bath.
- Silicon the feet only.
- No shower over spa bath.
Product Description
By default the massage bathtub is equipped with the following features as indicated in the illustration above:
- Water jets
- Suction
- Touch control pad
- Regulator
- Air jets
- Underwater light
TouchPad Usage Instructions
-
On/off:
Press this button, the system will start, the indicator light will be on; Press this button gain, the system will be closed and the indicator light will be off. -
Water pump function:
This function is controlled by the water level and will not be activated until the system detects the water. And the indicator light will flash when there is not enough water. After the pump is started, it will be automatically shut down after 60 minutes working. -
Wind pump function:
It is not controlled by the water level. It also will be automatically shut down after 60 minutes working.
The massage bathtub may be available with additional specification options
which may have been fitted on your bathtub. Please contact the seller if you
are unsure about the fitted op- tions.
Due to technological advance features on the bathtub may have been upgraded or
the position optimized by the manufacturer. Installed features shown on the
illustration are symbolic and for clarification only.
Carefully check the product specifica- tion to ensure that the bathtub is the model that you ordered. Do not install the bathtub if it is different from the model you ordered.
Electric Parameters
- Rated Voltage: 220 – 240 V
- Rated Frequency: 50 / 60 Hz
- Rated Maximum Power: 800 W
- Rated Maximum Current: 3.6A
Warning! Risk of fire and electric shock. All electrical connections should be made by a licensed, locally certified electrician, in accordance with the requirements of the national electrical codes and procedures.
Panel function description
Underwater lamp function:
Press this button can turn on off the underwater lamp.
System wiring diagram
Your massage bathtub includes a detailed Installed Installation & User Manual. Follow all instructions in the Installation & User Manual closely.
Electric Parameters
- Rated Voltage: 220 – 240 V
- Rated Frequency: 50 / 60 Hz
- Rated Maximum Power: 800 W
- Rated Maximum Current: 3.6A
Preparation of Connections
Due to technical advance positioning of relevant connections on the bathtub may be optimized. Literature dimen-sions are for reference only. Instal-lation dimensions should be taken directly from the tub.
Connection Position Chart
1. As the picture shows below, turn over the bathtub, wrap the drainer hole with thread PTFE tape, and then screw the drainer. We recommend using a Flexible Connector. Ensure the Flexible Connector is cut to the correct length for easier installation & to prevent drainage issues.
Usage
- Switch on the power supply
- Let water in.
- Don’t press the water pump switch unless the water level in the bathtub reaches higher than the jets position.
- Press the touch control pad and switch the regulator to adjust the intensity of the jets.
- Press the touch control pad, turn off the pumps and drain the water after use.
- Then turn off the power supply.
Troubleshooting
Trouble | Possible Reason | Try this to solve |
---|---|---|
Water pump Don’t work. | Power supply is not well connected, the leakage | |
protector disconnected. | Turn on the power supply, and connect the leakage |
protector.
Water pump impeller was stuck by sundries.| Clean the water pump impeller.
The water pump switch is off.| Press the water pump switch.
Power supply plug is not connected or not enough powery.suppl| Plug the power
supply in.
Water pump trouble.| Repair or replace the water pump.
Massage power can’t be adjusted.| Voltage problem.| Check voltage.
Adjust switch is off or has problem.| Check, replace the switch.
Water Circulation is blocked.| Clean the water circulation.
Bathtub don’t stand horizontally.| Adjustable foot is not well-adjusted.|
Adjust the adjustable foot.
Water leakage.| Seal ring is not good.| Replace the seal ring.
Nut is loose.| Screw down the nut.
Connecting part is not well connected.| Pay attention to the connecting part
connection.
Cleaning & Maintenance
- Should be cleaned with a soft cloth using warm saop water. Don’t use detergent that with acetone or ammonia. Disinfector with formic acid and formaldehyde is forbidden during disinfection.
- DO NOT USE BATH SALTS, IF SO, THIS AVOID WARRANTY.
- If there is scratch on the bathtub surface, use 2000# waterproof abrasive paper to polish it and lay toothpaste on. Then use soft cloth to furbish it.
- Scale deposit can be wiped off with warm citric acid or vinegar by a soft cloth.
- Screw off the Water Circulation and jets for cleaning when plug up by litter, such as hair
- Frequent cleaning is not necessary for the parts gilded and silver-gilt
- Don’t clean the tub with hard or coarse material to avoid any scratches; and don’t clean the tub by detergent with chemical menstrum to avoid any damages.
- Be sure to drain off the water and disconnect the power supply after use
- Don’t hit and score the bathtub by hard or keen-edged material. And don’t touch the bathtub by cigarette end or heat source that over 70 °C
- Water massage system cleaning: fill the bathtub with 40°C hot water, and add detergent(2g/L). Then run the water massage system for 5 minutes. After that, stop the pump and drain the water. Fill the bathtub with cold water, and run the water massage system for 3 minutes. Clean the bathtub after stopping the pump and draining off the water.
- Regular maintenance cycle is recommended. Please follow the above procedures for water massage system cleaning monthly and scale deposit cleaning as required.
Precautions
- The installation should be carried out by a qualified technician, and should be according to the manual.
- The appliance electric parameter should be tally with the National Safety Standard. And there should be creepage protector on the power supply. Make sure the ground wire is safe. Don’t touch the switch, electrical outlet and plug with water.
- Don’t use overheated water. Put cold water first, then hot water. Don’t run the appliance until the water level is higher than the jets.
- The rated voltage of this appliance is 220-240V.
- Disconnect the power supply after use
- Don’t take a bath for a long time. Recommended time: less than 30 minutes
- Please restart the appliance for occasional system halt
- If the supply cord is damaged, it must be replaced by the manufacturer, its service gent or similarly qualified persons in order to avoid a hazard.
- This manual is attached with the product. Before installation, please read it carefully. All the installation and usage should conform to this manual, to avoid damage or other accident.
- Spa bath to be installed in accordance with BCA and local regulatory standards by qualified person only.
- All isolation switch is recommended.
- The non return check valve is closed under normal operating pressure. It does not require plumbing into sewer since outflow is not expected in normal conditions.
Caution:
- When the bathtub can’t work, please check according to the troubleshooting list. If you can’t judge the reason or unable to repair it. please contact us.
- To insure the customers’ safety, the installation should be carried out by a qualified technician.
Please use eligible creepage protector. The ground wire should be well connected to the ground.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>