covix IFog Cordless Electrostatic Nebuliser Kit User Manual
- June 13, 2024
- covix
Table of Contents
- introduction
- Training service
- Technical service
- symbols used
- know your equipment
- safety warnings
- Personal Protective Equipment
- operating instructions
- troubleshooting guide
- technical specifications
- maintenance and care
- accessories and consumables
- guarantee conditions
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Cordless electrostatic nebuliser kit for effective surface disinfection
user manual
© This instruction manual is protected by copyright. We reserve all rights, especially the rights to produce, translate and prepare it using electronic systems
introduction
Dear Customer,
Thank you for placing your trust in a quality product from TEINNOVA. This
product has been made using modern manufacturing techniques and thorough
quality assurance measures. We do everything possible to ensure that you are
satisfied with this product and can operate it without any issues. Should you
have any questions about this product, please contact your dealer or contact
the company directly. Before use, carefully read the operating instructions
for your equipment. Treat this manual as part of the product and always keep
it nearby for future reference.
Training service
We offer companies optional training that is specific to our products and also teaches their operators how to provide the best service and thus contribute to the success of their end customers. Aspects such as knowing how to prepare a fair and objective quote, to respond to specific problems that may arise, or to offer a more professional and efficient service.
Technical service
Because we produce our own cleaning equipment, we are able to continuously
monitor the quality and performance of every machine we manufacture, and it is
this that has allowed us to maintain very low repair rates which have always
been quickly resolved by our own Technical Support Service, who are managed by
the same team as our factory.
We have all kinds of spare parts for your equipment, as well as related
accessories.
symbols used
All the symbols used in this manual, as well as those on the equipment itself, are explained in this section. It is important to read the text associated with these symbols carefully, since it is about personal safety and equipment safety.
DANGER!
This symbol warns of a potentially dangerous situation that could result in
serious injury or even death if the given instructions are not followed
appropriately. Make sure you read all the instructions in the “Safety
Information” section.
WARNING!
This symbol warns of a potentially dangerous situation which could result in
minor or moderate injuries, or property damage resulting in personal injury if
the instructions are not followed appropriately.
CAUTION!
This symbol warns of a situation that may cause damage to property, without
causing injury, if the instructions provided are not followed properly.
IMPORTANT!
This symbol highlights information on the best way to use the equipment while
avoiding any possible improper operation.
know your equipment
DESCRIPTION AND CONTENT
iFOG is an advanced system for applying biocides and pesticides to indoor and
outdoor surfaces in an economical, fast and efficient way.
It includes all the most advanced technologies; electrostatic induction allows
a 360º wraparound coating of all surfaces with a 60% reduction in the amount
of product used and with the shortest application time.
The lithium-ion batteries provide the user with total cordless autonomy for
several hours, the nebulisation is done by a 5-nozzle injection pump located
in the high volume air cannon, it sprays very fine particles that cover up to
8 metres, the electrostatic charge
allows the solution to adhere to surfaces in the hardest to reach places.
| ELECTROSTATIC INDUCTION TECHNOLOGY
---|---
| FULL COVERAGE OF THE SURFACE TO BE DISINFECTED
| CORDLESS SYSTEM WITH Li-ION BATTERY
| LOW PRODUCT USE BUT HIGHLY EFFECTIVE
| ERGONOMIC AND LIGHTWEIGHT FOR USE AS BACKPACK
APPLICATIONS
| Disinfection of spaces
---|---
| Disinfection of air ducts
| Application of pesticides in farming
know your equipment
EQUIPMENT PARTS AND CONTENTS
CHANGING THE NEBULISER HEAD NOZZLES
DO NOT change the nozzles with the equipment turned on, it may cause an electric shock.
INTERCHANGEABLE NOZZLES
NOZZLE | SIZE | REF No. |
---|---|---|
0.5 mm | 10 microns | BFW-1 |
1.0 mm | 30 microns | BFW-2 |
1.5 mm | 60 microns | BFW-3 |
If you want to cover one or two of the outlet nozzles, remove the nozzle and
screw this cap on.
Use it with water soluble chemical solutions.
HOW ELECTROSTATIC
NEBULISATION WORKS
-
The disinfectant solution is ionised using a high voltage negative electrode. The injection pump generates the microparticles through the 5 nozzles which move with the air produced by the high volume blower.
-
The negatively charged nanoparticles repel each other, keeping them uniformly spaced acting against gravity, to cover the hardest to reach surfaces.
-
The surfaces are positively charged, therefore the disinfectant solution is electrostatically attracted, ensuring a uniform 360º coverage of the whole surface.
safety warnings
- This equipment contains an electrostatic device that can interfere with sensitive medical devices such as pacemakers, defibrillators, or similar devices. DO NOT use this machine or be within 3 metres of it if you use one of these medical devices.
- DO NOT use this equipment in explosive atmospheres, or where there are flammable liquids, gases or powders.
- DO NOT spray people or animals, it could cause damage to health, check the safety sheet for the chemical used.
- DO NOT touch or introduce foreign objects into the nebulisation nozzles, this may cause an electric shock when the equipment is turned on.
- DO NOT use the equipment outdoors when it is raining, or store it in humid or very hot areas.
- DO NOT leave the unit charging for an extended period of time unattended.
Personal Protective Equipment
WARNING
This equipment contains an electrostatic device that can interfere with
sensitive medical devices such as pacemakers, defibrillators, or similar
devices. DO NOT use this machine or be within 3 metres of it if you use one of
these medical devices.
operating instructions
Before use:
Read this user manual carefully, following all the safety measures indicated.
Fill the tank, to no more than the maximum level, with a water-based chemical
solution, charge the battery to 100% capacity.
Operation:
Use the nozzles for the particle size you want 10, 30 or 60 microns, place the
equipment on your back and adjust the straps to fit you, turn on the equipment
and point the nebulisation cannon in the direction of the surfaces and objects
to be sprayed, keeping a suitable spacing. Use the switch on the cannon to
turn on the blower and blow air over the nozzles up to a range of 8 metres.
During use:
Turn the machine off and put the air cannon in the equipment side housing,
fixing it with the elas-tic strap. Empty what’s left from the tank, add a
litre of water and spray for 5 minutes, until the tank is empty. Clean the
nozzles and the rest of the equipment of any debris that may be left. Store in
a dry place with low humidity. After a complete cycle, leave the equipment
charging the battery. If you are working in a small area, do not run the
equipment for more than 30 minutes. The amount of liquid misted will depend on
the type of nozzle fitted.
troubleshooting guide
problem | solution |
---|---|
The power of the fog is low. | Activate the cannon blower. |
The equipment does not produce the mist. | The tank may be empty, fill it with |
the chemical solution.
The nebuliser is behaving erratically, turning itself on and off.| Check the
battery is sufficiently charged, charge the battery.
The nebuliser heats up during normal usage.| Check the equipment temperature
on the control panel and let it rest for a while before turning it on again.
technical specifications
TECHNICAL FEATURES
Nominal voltage Motor power | 24 V- 30 Ah 200 W |
---|---|
Battery operating time | 4 h with blower |
10 h without blower
Droplet size| 10, 30 and 60 micron
3 types of nozzle
Coverage| 8 m with blower
4 m without blower
Tank capacity| 10 litres/2.6 gal
Rechargeable battery type| Lithium 24V. 30 Ah.
4 hour charging time
Sound level| 60 dB
Dimensions (L x W x H)| 740 x 280 x 670 mm 29 x 11 x 26.3 inch
Empty weight| 11 kg/24 lb
maintenance and care
- Always use the charger provided when charging the battery.
- Regularly check soft parts such as hoses and gaskets to check for wear. If they are broken or damaged, they should be replaced.
- Like any apparatus for the application of chemical products, you will need to clean all the parts of your unit to avoid the accumulation of residues which may affect its performance.
- Clean the equipment’s nebulising nozzles frequently.
Spare Parts:
TEINNOVA has spares for all the equipment parts.
If you need any part or consumable, please contact
TEINNOVA Customer Service on +34 941 44 50 56.
accessories and consumables
CONSUMABLES
AK-GERMA 100
Super concentrated disinfectant
for germs, fungi and viruses. Box
of 6 1-litre containers.
CODE PQ8400113
guarantee conditions
-
“TEINNOVA” guarantees its products for a period of 15 days for aesthetic defects or product faults which are noticeable at first sight, and for a period of 1 year when dealing with all other manufacturing defects or product faults.
The “Buyer” must report the existence of any defect as soon as they become aware of it and, in any case, within the maximum period of 5 days from when it becomes apparent. Any notification outside of this deadline shall lead to the non-application of the guarantee.
“TEINNOVA” will collect and send the products to the factory or to the closest official Technical Support Service for inspection. At this point, it will be determined whether the guarantee can be applied or whether it falls under the guarantee exclusions.
If the guarantee is applicable, the transport fees, both those for collecting the product from the client’s facilities and for returning it there will be paid by TEINNOVA. If it is excluded from the guarantee (section 2), the transport fees, both those for collecting the product from the client’s facilities and returning it there will be paid by the client. “TEINNOVA” reserves the right to dismiss the application of the guarantee in the event that there is no evidence of the product’s non-conformity, and it shall not apply said guarantee until coverage has been expressly approved. Should the product be covered, “TEINNOVA” can replace it or determine the necessary repair method. All repair works that are carried out under the product guarantee must be carried out in “TEINNOVA” facilities or in those of the party it designates. The guarantee covers the materials and labour required to repair or replace the parts or elements considered as defective from origin. The maximum guaranteed amount or value shall be the maximum price of the sale of the product to the “Buyer”. Any claims made under the coverage of the guarantee shall not grant the right to delay and/or withhold payment of the corresponding invoice and/or any other pending invoices. -
Guarantee Exclusions: The following are excluded from the guarantee: Usage of, alterations to or handling of the product done without the express prior permission of the Vendor, indirect and/or consequential damage, intentional damage, damage caused by negligence or by improper use or by a use not covered by the product’s instructions, faults due to changes made to the product or the use of parts that were not previously certified or expressly authorised by the Vendor; fault detection costs, costs of collection or replacement (the latter two unless the non-conformity is proven and within the limits set out in section 1).
Product certificate
TECAI INNOVA S.L. certifies that the referenced product meets the essential
health and safety requirements related to design and manufacture provided in
the European Directive.
The company has the following Quality Certificates: Management System ISO
9000:2015 and Environmental Management ISO 14.001:2015.
The company is registered in the Registro Oficial de Establecimientos y
Servicios Biocidas (Official Registry of Biocidal Establishments and
Services).
ROESB registration number: 026-CAR-110
Product details:
iFOG Electrostatic Nebuliser
Manufacturer information:
Manufacturer name: TECAI INNOVA S.L.
Address: C/ Las Balsas 16-B,
Pol. Ind. Cantabria 26009,
Logroño (La Rioja), España
Telephone: +34 941 44 50 56
Website: www.teinnova.net
Under its sole responsibility, TECAI INNOVA S.L. certifies that the machine
model described above complies with all the essential requirements of the
following directives:
– Directive machines 2006/42/CEE
– Electromagnetic Compatibility (EMC) Directive – 2014/30/CEE
– Low Voltage Directive – 2014/35/CEE
The following standards have been followed in its design:
EN ISO 12100:2010/EN ISO 13850:2008
EN 60204-1:2006/EN 614-1:2006+A1:2009
References
- Duct cleaning equipment - Air duct cleaning and Kitchen exhaust cleaning equipment
- Duct cleaning equipment - Air duct cleaning and Kitchen exhaust cleaning equipment