RS210/310 Electric Strike Installation Instructions
The RS210/310 Electric Strike is surface mounted and designed with the strength and durability for use with rim exit devices with a 1/2” (RS210) or 3/4” (RS310) throw Pullman latchbolt. No cutting on the frame is required for installation. Unit is field selectable for fail-safe and fail-secure operation, and for 12 or 24VDC. The RS210 has a 1/2” (12.7mm) thick metal housing. The RS310 has a 3/4” (19mm) thick metal housing.
Specifications
Operating Voltage | 12/24VDC |
---|---|
Current Draw | 540mA/12VDC, 270mA/24VDC |
Operating Temperature | 14°F to 1200F(-100C–i-49°C) |
Static Strength | 1500 lbs |
Dynamic Strength | 70 ft-lbs |
Endurance Rating | 250,000 cycles |
Lock Mode | Field selectable fail-safe and fail-secure Non-fire rated model |
UL Requirements
- The RS210/310 series is intended to be used with UL Listed Exit hardware
- The RS210/310 series shall not impair the intended operation of an emergency exit
- The RS210/310 series shall not impair the operation of panic hardware mounted on the door
UL294
Performance Level| Destructive Attack: Level I
Line Security: Level I
Standby Power: Level I
Endurance: Level IV
---|---
Wiring Diagrams
CAUTION
Overheated or burnt coils caused by incorrect voltage/wire harness
combinations will not be covered under warranty
Latch Monitor
(On select models)
WARNING
Warnings indicate potentially hazardous conditions, which if not avoided or
corrected, may cause death or serious injury.
CAUTION
Cautions indicate potentially hazardous conditions, which if not avoided or
corrected, may cause minor or moderate injury. Cautions may also warn against
unsafe practices.
NOTICE
Notices indicate a condition that may cause equipment or property damage only.
Surface Mount Installation
Changing Fail-safe/Fail-secure
Fail-secure (factory default) or fail-safe is field selectable for NON-FIRE RATED MODELS ONLY by changing position of screws as shown.
- Loosen and remove the locking screw.
- Loosen and move the sliding screw to the desired setting, and replace/retighten both screws.