DELTA REGIS DR-XTC Series Transducer Controller Instruction Manual

June 13, 2024
DELTA REGIS

DR-XTC Series Transducer Controller

DR-XTC Series Transducer Controller

Product Specifications

  • Model: DR-XTC1, DR-XTC2

  • Input Voltage: AC 115/230V, 50/60 Hz,
    6.3A

  • I/O Output Voltage: DC 24V 50mA / 12V
    100mA

  • Count: 1-99

  • Count Method: Incremental/Decremental

  • Torque Detection Value: Based on Screwdriver
    Specifications

  • Screw Thread Number: External Connection
    Input

  • External Connection Output: Interface
    Compatible Software

  • External Dimensions: 185 x 241.4 x 127 mm
    (DR-XTC1), 185 x 241.4 x 146.8 mm (DR-XTC2)

  • Weight: 2.5 Kg (DR-XTC1), 3.7 Kg
    (DR-XTC2)

Product Usage Instructions

  1. Step 1: Power Connection
    Connect the AC power socket to the appropriate power source using
    the provided power cable. Set the 110/220VAC switch to the correct
    voltage setting.

  2. Step 2: Tool Connection
    Connect the tool connector to the screwdriver model specified in
    the product specifications.

  3. Step 3: Data Storage
    Insert a Micro SD card into the Micro SD card slot for data
    storage.

  4. Step 4: Data Cable Connection
    Connect a data cable to the RS-232 port for data transfer.

  5. Step 5: Firmware Update
    If required, connect a firmware update port to update the firmware
    of the controller.

  6. Step 6: Optional Connections
    Connect additional devices such as a barcode scanner or LAN
    communication port, if needed.

  7. Step 7: Input/Output Signal Terminals
    Connect input and output signal terminals as per the requirements
    of your application.

  8. Step 8: Panel Operation
    Familiarize yourself with the panel buttons and LEDs described in
    the user manual. Use the buttons to navigate through the settings
    and monitor the status displayed on the LCD screen.

  9. Step 9: System Programming
    To enter programming mode, press and hold the ESCAPE button for 3
    seconds. Enter the password and press the Enter button to access
    programming mode. Use hot keys and buttons to navigate and make
    necessary programming changes.

DR-XTC Series Transducer Controller Operation Manual

CAUTION — Please read, understand, and follow all operating and safety instructions in this manual before using a DR-XTC controller.
If you have any questions or concerns, please contact us at:

Delta Regis Tools Inc. 7370 Commercial Circle Fort Pierce, FL 34951 USA

Ph +1-772-465-4302 Fx +1-772-465-4368 Email: sales@deltaregis.com Website: www.deltaregis.com
Delta Regis_DR-XTC Series_M_R0.4 Copyright © 2023 Delta Regis Tools Inc

Table of Contents
1. Product Specifications……………………………………………………………. 2 2. Appearance………………………………………………………………………….. 3
2.1 – Panel…………………………………………………………………… 3 2.2 – Connections…………………………………………………………. 4 2.3 – Upper Case………………………………………………………….. 4 2.4 – Settings display ……………………………………………………. 5 3. System Programming…………………………………………………………….. 5 3.1 – Hot Key Function…………………………………………………… 5 3.2 – Programming Mode……………………………………………….. 5 4. Control Setting………………………………………………………………………. 6 5. Program Setting…………………………………………………………………….. 8 6. Screw Setting………………………………………………………………………… 8 7. Extra Function……………………………………………………………………….. 9 8. CONFIRM Mode…………………………………………………………………….. 10 9. External Output Control Function Description…………………………….. 12 10. External Input Control Function Description……………………………… 13 11. Data transmission and flow control suggestion…………………………. 14 12. EXPLODED VIEW & PARTS LIST…………………………………………..

1. Product Specifications

Model Input Voltage I/O Output Voltage Count Count Method Torque Detection Value Screw Thread Number External Connection Input External Connection Output Interface Compatible Software External Dimensions
Weight DC Screwdriver model

Specifications

DR-XTC1

DR-XTC2

AC 115/230V, 50/60 Hz, 6.3A

DC 24V 50mA / 12V 100mA

1-99

Incrimental/Decremental

Based on Screwdriver Specifications

0.0-999.9

Start/Forward/Reverse/Disable/Confirm

OK/NG/OK ALL/Start/Reverse

RS-232, Micro SD, LAN, USB, I/O Terminals

deltaOnpoint

185 x 241.4 x 127 mm 185 x 241.4 x 146.8 mm

(7.3 x 9.5 x 5″)

(7.3 x 9.5 x 5.8″)

2.5 Kg (7.5 lbs)

3.7Kg (8.2 lbs)

ESL-XTE1/3/5/7 Series ESL-XTE12/18/25 Series

7370 Commercial Circle
Fort Pierce, FL 34951 ( 772.465.4302

www.deltaregis.com sales@deltaregis.com
3

2. Overview
2.1 Panel

1. OK Signal LED 2. NG Signal LED 3. OK ALL Signal LED 4. Torque Value Screen 5. ESC button (Return/ Leave/Enter Programming Mode) 6. Up/Down/Left/Right Buttons

7. Tool Run Signal LED 8. Tool Reverse Signal LED 9. Tool Disabled Signal LED 10. LCM Display Screen 11. Enter Button (Select/ Confirm)

10. LCD Screen
4

Job: Job/Project JS: Job Sequence Time: Run Time TP: Tightening Program TR: Tightening Repeat Thread: Rotations Torque: Torque Value Status: (OK/NGT/NGQ/NGC/OKALL)

7370 Commercial Circle
Fort Pierce, FL 34951 ( 772.465.4302

www.deltaregis.com sales@deltaregis.com

2.2 Bottom Housing Connections
1. Micro SD card slot (Data Storage) 2. RS-232 Port (Data Cable) 3. Firmware update port 4. Tool connector 5. AC power socket, fuse, power switch

6. 110/220VAC Switch 7. Barcode Scanner Port 8. LAN comm port 9. Output Signal Terminal 10. Input Signal Terminal

2.3 Top Housing
1. DC Fuse (10A/250V) 2. Grounding Screw

7370 Commercial Circle
Fort Pierce, FL 34951 ( 772.465.4302

www.deltaregis.com sales@deltaregis.com
5

2.4 Settings Display (LCD)

1. Display Job Number 2. Display Sequence 3. Display Status (OK/NGT/NGO/OK ALL) 4. Display Job Sequence Number

5. Display Repeat Number 6. Display Run Time 7. Display Rotation Number 8. Display Torque Value

3. System Programming
3.1 Hot Keys
1. Left button: Hold 3 seconds to jump to the first job sequence. 2. Down button: Hold 3 seconds to jump to the last job sequence. 3. Up button: Use up and down button to scroll through tool settings. 4. Right button: Hold for 3 seconds to jump to the next job sequence.
3.2 Programming Mode
5. Hold “ESCAPE” button for 3 seconds to enter programming mode. 6. Input password and press Enter button to enter programming mode.
**Default password is 0000. Once in programming mode use Up and Down arrows to select appropriate setting to change. Use Enter button to move forward through settings and use Escape button to move back.

7370 Commercial Circle

www.deltaregis.com

Fort Pierce, FL 34951

sales@deltaregis.com

6

( 772.465.4302

4. Control Setting

Name
OPERATION MODE
DEVICE ID TOOL START METHOD SETTING TOOL LED SETTING EDIT JOB SEQUENCE SETTING
PROGRAM DEFAULT TORQUE UNIT GATE MODE

Value

Function Description

STD/ADV

Connection mode. STD: Standalone mode. ADV: KL-AMS network system. (STD/ADV) connection mode.

001~250

Equipment No.

Both Push Lever

Choose tool start mode.

Start on Always on Off

Set tool work-light LED on or off.

Job: 01~50 JS: 01~50 TP: 00~99 TR: 00~99
Reverse Button Setting: 1. Direction: CW/CCW 2. Force Level: 0~9 3. RPM: Please refer to the specification of screwdrivers

Setup screw sequence and repeats in job project, save up to 50 projects.
JS: display job sequence. TP: display tightening program. TR: display repeat times.
Reverse button settings: Forward (CW) and reverse (CCW) Force Level: Number of force segments Force 0(disabled) 1~9(10%~100%) RPM: Set reverse speed.

00~50

Select Program

N/Y

Return to factory default settings.

kgf.cm, N.m, kgf.m, lbf.in

Set up torque display unit.

Off, Once, Twice

OFF: Function off. Once: Workpiece in position (Short signal.) Twice: Workpiece in/out position (Open signal).

Default STD
01 Both Off Job: 01 JS: 01 TP: 00 TR: 00
00 N kgf.cm Off

7370 Commercial Circle
Fort Pierce, FL 34951 ( 772.465.4302

www.deltaregis.com sales@deltaregis.com
7

4. Control Setting Continued

Name

Value

Function Description

Default

OKALL SIGNAL Once/Each

OKALL signal output method Once: Output OKALL signal after all sequences completed. OKALL signal output time depends on At setting. Each: Output OKALL signal after each sequence completed. OKALL signal output time depends on At setting.

Once

STORE JOB BARCODE

1~50

“Scan job barcode “will show after

01

pressing. After using scanner to scan

barcode, it will save barcode into

controller automatically. Setup sequence

1 to 50, will switch to barcode sequence.

Barcode length should not exceed 20 bits.

BARCODE SETTING How to select/ switch Job by barcode scanning

Define a valid barcode range From: 01~20 Bits: 01~20 To Binding Job (01~50)

Below steps will show you how to use certain section of a barcode to select/ switch Job. Step 1. Determine the initial point of the section (01-20) Step 2. Determine section size (01-20) Step 3. Assign selected section to Job (01-50)

Job: 01 From: 01 Bits:01

BATCH MODE INC/DEC

Select count up or count down

DEC

TIME SETTING YYYY/MM/DD Set up controller time

HH:MM:SS

Year/Month/Day/Hour/Minute /Second.

2018/01/01 01:01:01

SETUP

Serial Number Display device product serial number.

PRODUCT

serial number

Product Barcode

PASSWORD 0000~9999 Set up password lock

0000

INTERNET SETTING

Offline/Online/ Select data output from offline to online Offline RS -232

ACOUSTIC

On/Off

Setup beep.

On

MODE

LANGUAGE

Chinese/ English

Select language

English

FIRMWARE V1.XXX

Display controller firmware version

V1.XXX

7370 Commercial Circle

www.deltaregis.com

Fort Pierce, FL 34951

sales@deltaregis.com

8

( 772.465.4302

5. Program Setting

Name

Value

Function Description

Default

Screw Step 001~250

Step can set the speed, target value 01 (torque / time / number of turns)

Program Name


Setup program name


RPM

Please

Setup rotation speed

Please

refer to the

(According to screwdriver type)

refer to the

specification of

specification of

screwdrivers

screwdrivers

Option

Q/C

Setup tightening target

Q

Direction

CW/CCW

Setup rotation direction

CW

Delay Time 0.0~9.9

Setup interval time between screws 0.8

Target Thread 000.0~999.9 Setup target number of threads

005.0

Target Torque

Please refer to the specification of screwdrivers

Setup target torque

Please refer to the specification of screwdrivers

Hi Torque Kg.cm 000.01~99.99 Setup max. torque value

005.00

Lo Torque Kg.cm 000.00~99.98 Setup min. torque value

000.00

Hi Thread Lo Thread

000.1~499.9 000.0~499.8

Setup max. thread value Setup min. thread value

499.9 000.0

6. Screw Setting

Name

Value

Screw Sequence 01~99

Screw Name


Screw Reverse 001~250

Sequence 1

001~250

Sequence 2

001~250

Sequence 3

001~250

Sequence 4 Sequence 5

001~250 001~250

OKALL Hold Time 0.0~9.9

Function Description
Setup screw parameter. Setup screw parameter name. Setup screw reverse strategy Setup 1st sequence Setup 2nd sequence Setup 3rd sequence Setup 4th sequence Setup 5th sequence AT: OKALL signal holding time

Default 01 ** 01 01 00 00 00 00 1.0

7370 Commercial Circle
Fort Pierce, FL 34951 ( 772.465.4302

www.deltaregis.com sales@deltaregis.com
9

6. Screw Setting Continued

Name

Value

OK One Hold Time 0.0~9.9

NOK Disable Screwdriver

ON/OFF

OKALL Disable Screwdriver

ON/OFF

Function Description Default

OT: OK signal holding time

0.0

Disables screwdriver when

OFF

error occurs.

ON: When malfunction signal

“NS” occurs, it will disable

screwdriver immediately;

User will need to press

“ENTER” button to deactivate

rotation(For I/O part. But

screwdriver can reverse.)

OFF: When malfunction “NG”

occurs, screwdriver will not

be disabled & it will not affect

next activation. It will provide

a warning

Disable screwdriver when

OFF

batch completed

ON: Disables screwdriver after

batch completed. Users need

to press”ENTER” button (For I/O

part, it is confirm signal)

OFF: Screwdriver is not

disabled after batch

completed.

7.Extra Function

Name
Export to SD Card
Calibration Tool

Function Description
Export to controller internal setting value (Controller setting/Program setting/Screw setting)
Calibration mode

7370 Commercial Circle

www.deltaregis.com

Fort Pierce, FL 34951

sales@deltaregis.com

10

( 772.465.4302

8. Confirm Mode

Code
C1 C2 C3
C4
C5
NS BS OK
OKALL NG

Description

Disable Method

Once external confirmation “GATE” External GATE Signal; Trigger once

Twice external confirmation “GATE” External GATE Signal; Trigger twice

When “OKALL disable screwdriver” function is on, LCM will display “C3″after a batch completed.

Panel Enter button/ External CONFIRM

When “OKALL disable screwdriver” & “Gate mode-trigger once” functions are on; LCM will display “C4” after a batch completed.

External GATE Signal Trigger once + Panel Enter Button/ External CONFIRM

When “OKALL disable screwdriver” & “Gate Mode-trigger twice” functions are on; LCM will display “C5” after a batch completed.

External GATE Signal Trigger twice +Panel Enter Button/ External CONFIRM

When error occurs, LCM will display “NS”

Panel Enter Button/ External CONFIRM

When Barcode Enabled, “BS” will be Barcode scan function displayed before the job is executed.

When screwdriver has completed

NA

proper tightening, LCM will

display”OK”

When a batch is completed LCM will NA display “OK ALL”

NG-F: Sequence incomplete

NA

NS-F: Press Confirm/Enter for next

action.

NGQ: When output torque isn’t inside

set torque range. Output torque could

be lower than “LQ” or higher than

“HQ”

NGC: When number of output shaft

rotations isn’t inside set range. No. of

rotation could be lower than “LC” or

higher than “HC”.

7370 Commercial Circle
Fort Pierce, FL 34951 ( 772.465.4302

www.deltaregis.com sales@deltaregis.com
11

8. Confirm Mode Continued

Code
E3
E4
E5
E7
E8 E9 Er ES EOC ELS

Description

Disable Method

Voltage-drop protection: When the voltage of the

NA

electric screwdriver drops suddenly, the electric

screwdriver will be disabled, and the LCM displays “E3”

symbol, representing that the screwdriver is currently

under low-voltage protection.

Over-temperature protection: When the internal

NA

temperature of the electric screwdriver is too high,

the electric screwdriver will be disabled, and the LCM

displays “E4” representing that the screwdriver is

currently under over-temperature protection.

Stall protection: When the startup of the electric

NA

screwdriver motor is abnormal, the electric

screwdriver will be stopped, and the LCM displays “E5”

representing that the screwdriver is currently under

motor stall protection.

Torque abnormal: When sensor has received the

NA

abnormal parameters form screwdriver, it will stop the

actions of the screwdriver and display “E7” symbol on

the LCM.

Temp cooling down state: When the screwdriver

NA

enters the temperature protection, it will disable the

screwdriver and display “E8” symbol on the LCM.

Abnormal operation: When the screwdriver runs

NA

continuously for more than 20 seconds, it will disable

the screwdriver and display “E9” symbol on the LCM.

GATE function abnormal: When the GATE function is NA on and function abnormal, the buzzer will alarm and LCM displays “ER”.

Screwdriver communication error: If a

NA

communication error occurs, the electric screwdriver

will be disabled and the LCM displays “ES”.

EOC Calibration is required

NA

When LCM displays the word ELS, it indicates that the SD card capacity is less than 100MB, and it will disable the screwdriver. Press the Enter key to release the screwdriver.

Press Enter Button

7370 Commercial Circle

www.deltaregis.com

Fort Pierce, FL 34951

sales@deltaregis.com

12

( 772.465.4302

9. External Output Control Function Description

Connector No. Definition

CN 1

START

CN 2

COM

CN 3

CN 4

CN 5

REVERSE

CN 6

COM

CN 7

OK

CN 8

COM

CN 9

NG

CN 10

COM

CN 11

OKALL

CN 12
CN 13 CN 14

COM
VDC GND

Description
RUN FWD: When the screwdriver is on, CN1 & 2 short. When it short, CN1+CN2 short. When it open, CN1+CN2 open.

RUN BWD: When the screwdriver reverse, CN5 & 6 short. When it short, CN5+CN6 short. When it open, CN5+CN6 open.
OK: When a screw is fastened, CN7 & 8 short. When it short, CN7+CN8 short. When it open, CN7+CN8 open.
NOK: When there is malfunction, CN9 & 10 short When it short, CN9+CN10 short. When it open, CN9+CN10 open.
OK SEQUENCE: When it completed sequence setting screw, CN11 & 12 short. When it short, CN11+CN12 short. When it open, CN11+CN12 open.
Output voltage 24Vdc/50mA & 12Vdc/100mA
Output voltage GND

7370 Commercial Circle
Fort Pierce, FL 34951 ( 772.465.4302

www.deltaregis.com sales@deltaregis.com
13

10. External Input Control Function Description

Connector No. Definition

Description

CN 1 CN 2

External start signal input START_IN
GND

1. When CN1+CN2 short (CLOSE) screwdriver starts. 2. When CN1+CN2 open (OPEN) screwdriver stops.

CN 3 CN 4

External reverses signal input REVERSE
GND

1.When external reverse signal CN3+CN4 short (CLOSE) first and activates signal CN1+CN2 short (CLOSE), screwdriver will start in reverse. 2.When external reverse signal CN3+CN4 open (OPEN) first and activates signalCN1+CN2 short (CLOSE), screwdriver will start regular.

CN 5 CN 6

External disable signal input DISABLE
GND

1.When CN5+CN6 short (CLOSE), screwdriver cannot be activated. 2.When CN5+CN6 open (OPEN), screwdriver can be activated.

CN 7 CN 8

External confirm signal input CONFIRM
GND

1.When system requests to press confirm button, we can short CN7+CN8 (CLOSE) instead. 2. After CONFIRM is executed, the NG signal is also cleared.

CN 9 CN 10

External clear signal input CLEARED 1.To clear sequence/program, it can be activated by shorting CN9+CN10(CLOSE) GND

CN 11 CN 12

External sensor switch GATE
GND

1.By inputting a confirm signal, it makes unit to judge its effective value. 2.Sensor switch: Switch in process can be CN 12 GND one or two.

CN 13 CN 14

External confirm SEQUENCE CLEARED
GND

When we need to clean sequence, it can be activated by shorting CN13+CN14 (CLOSE).

7370 Commercial Circle

www.deltaregis.com

Fort Pierce, FL 34951

sales@deltaregis.com

14

( 772.465.4302

9. Data transmission description & flow control suggestion
1. Controller power on and time synchronization After controller is powered on, it will send data {REQ100…} every second to external device such as computer PLC/AMS. The external device needs to reply {CMD100,….} to sync the external device time to the controller. If the controller does not receive {CMD100,….},{REQ100,…}will be sent again after 10 seconds.
2. When controller receives barcode information, it will send scanned data and data format as {REQ101,…} to external device for control judgement or record saving. External device needs to reply {CMD100,….}.
3. After controller is powered on and screwdriver shuts off, brake signal format as {DATA100,….} will be sent. Every shut off will cause column 14 (no. of total tightenings on controller) to increase by 1. External device needs to reply {CMD100,….}, if not, the controller will keep sending DATA100(only update date time) and column 14 (no. of total tightenings on controller) value will remain unchanged.
4. Shut off data will be sent after each shut off. Use the column 14 (no. of tightenings on controller) to judge if there is new shut off data or not.
5. When controller receives feedback and format as {CMD100,….} from external device, controller will resume automatically sending {REQ100,…} and be able to configure controller time.
6. Recommended software control flow as below: P.S: The content of [CMD100] in flow as the below:
{CMD100,YEAR,MONTH,DAY,HOUR,MINUTE,SECOND,0000,0000,0,1}
Str2 0001~9999 YEAR Str3 01~12 MONTH Str4 01~31 DAY Str5 00~23 HOUR Str6 00~59 MINUTE Str7 00~59 SECOND Str8 0000-9999 Check Sum (YEAR+MONTH+DAY+HOUR+MINUTE+SECOND = Check Sum) Str9 0000-9999 Key Code (Check Sum + 5438 = Key Code) Str10 (default: 0) Str11 Instruction number (Same as the Instruction number of REQ100)

7370 Commercial Circle
Fort Pierce, FL 34951 ( 772.465.4302

www.deltaregis.com sales@deltaregis.com
15

7. When the screwdriver is running, it will start transmitting {DATA101,….} until the screwdriver status (for example: NG,OK…) is generated.

7370 Commercial Circle

www.deltaregis.com

Fort Pierce, FL 34951

sales@deltaregis.com

16

( 772.465.4302

7370 Commercial Circle
Fort Pierce, FL 34951 ( 772.465.4302

www.deltaregis.com sales@deltaregis.com
17

7370 Commercial Circle

www.deltaregis.com

Fort Pierce, FL 34951

sales@deltaregis.com

18

( 772.465.4302

7370 Commercial Circle
Fort Pierce, FL 34951 ( 772.465.4302

www.deltaregis.com sales@deltaregis.com
19

7370 Commercial Circle

www.deltaregis.com

Fort Pierce, FL 34951

sales@deltaregis.com

20

( 772.465.4302

7370 Commercial Circle
Fort Pierce, FL 34951 ( 772.465.4302

www.deltaregis.com sales@deltaregis.com
21

7370 Commercial Circle

www.deltaregis.com

Fort Pierce, FL 34951

sales@deltaregis.com

22

( 772.465.4302

DR-XTC Series Transducer Controller

7370 Commercial Circle

www.deltaregis.com

Fort Pierce, FL 34951

sales@deltaregis.com

24

( 772.465.4302

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)