AUTOTROL 400 Series Demand Controls Instruction Manual

June 13, 2024
AUTOTROL

AUTOTROL 400 Series Demand Controls Instruction Manual
Demand Controls

MAN

UAL OVERVIEW

How To Use This Manual
This installation manual is designed to guide the installer through the process of installing and starting conditioners featuring the 400 series controllers. This manual is a reference and will not include every system installation situation. The person installing this equipment should have:

  • Training in the 400 series controllers and water conditioner installation
  • Knowledge of water conditioning and how to determine proper control settings
  • Basic plumbing skills
  • The directional instructions “left” and “right” are determined by looking at the front of the unit.

SAFETY INFORMATION

Electrical
There are no user-serviceable parts in the AC adapter, motor, or controller. In the event of a failure, these should be replaced:

  • All electrical connections must be completed according to local codes.
  • Use only the power AC adapter that is supplied.
  • The power outlet must be grounded.
  • To disconnect power, unplug the AC adapter from its power source.

Mechanical

  • Do not use petroleum based lubricants such as petroleum jelly, oils, or hydrocarbon based lubricants. Use only 100% silicone lubricants.
  • All plastic connections should be hand tightened. Plumber’s tape may be used on connections that do not use an O-ring seal. Do not use pliers or pipe wrenches.
  • All plumbing must be completed according to local codes.
  • Soldering near the drain line should be done before connecting the drain line to the valve. Excessive heat will cause interior damage to the valve.
  • Do not use lead-based solder for sweat solder connections
  • The drain line must be a minimum of 1/2″ diameter. Use 3/4″ pipe if the backwash flow rate is greater than 5 GPM (18.9 Lpm) or the pipe length is greater than 20 feet (6 m).
  • Do not support the weight of the system on the control valve fittings, plumbing, or the bypass.

General

  • Keep the media tank in the upright position. Do not turnon side, upside down, or drop. Turning the tank upside down will cause media to enter the valve.
  • Operating ambient temperature is between 34ºF (1ºC) and 120ºF (49ºC).
  • Operating water temperature is between 34ºF (1ºF) and 100ºF (38ºC)
  • Working water pressure range is 20 to 125 psi (1.38 to 8.61 bar). In Canada the acceptable working water pressure range is 20 to 100 psi (1.38 to 6.89 bar).
  • Use only regenerant salts designed for water softening. Do not use ice melting, block, or rock salts.
  • Follow state and local codes for water testing. Do not use water that is micro-biologically unsafe or of unknown quality.
  • When filling media tank, do not open water valve completely. Fill tank slowly to prevent media from exiting the tank.
  • When installing the water connection (bypass or  manifold) connect to the plumbing system first. Allowheated parts to cool and cemented parts to set before installing any plastic parts. Do not get primer or solvent on O-rings, nuts, or the valve.

California Proposition 65 Warn

WARNING: This product contains chemicals known to the State of California to cause cancer or birth defects or other reproductive harm.

SYSTEM SPECIFICATIONS

Grounding Icon
The systems below have been tested and certified by the WQA to NSF/ANSI Std. 44 and NSF/ANSI 372for “lead free” compliance

The 255 valve has been tested and certified by the WQA to NSF/ANSI Std. 61 Section 8 Mechanical Devices
WQA Certified 255-460i Systems:

255-460i-075-844
255-460i-100-948

Working Pressure: 20-125 psi (1.38 – 8.61 bar

Standard 12 Volt Transformer Input Electrical Rating : 115V 60 Hz Optional 12 Volt Transformer
Input Electrical Rating: 115V 50 Hz, 230V 50 Hz, 230V 60 Hz, 100V 60 Hz, 100V 50 Hz

Operating Ambient Temperature : 34-120°F (1-49°C)
Operating Water Temperature: 34-100°F (1-38°C

For service or parts, please contact your local professional water treatment dealer.

WATER SOFTENER PERFORMANCE DATA SHEET

Model| 255-460i-075-844| 255-460i-100-948| | |
---|---|---|---|---|---
Rated Service Flow (gpm)| 6.0| 10.0| | |
Pressure Drop at Rated Service Flow Rate (psi)| 9.0| 15.0| | |
Rated Capacity (grains @ lb. of salt)| 15, 362 @ 3.7521,197 @ 7.523,148 @ 10.5| 20,483 @ 5.028,263 @ 10.030,865 @ 14.0| | |
Rated Efficiency(grains/lb Salt @ lb. of salt)| 4,096/lb. salt @ 3.75| 4,096/lb. salt @ 5.0| | |
Maximum Flow Rate During Regeneration (gpm)| 1.7| 2.1| | |
Sybron C-249NSIon Exchange Resin (cu. ft)| 0.75| 1.0| | |
Backwash – GPM| 1.7| 2.1| | |
Fast Rinse/Purge – GPM| 1.7| 2.1| | |
Operating Pressure :20 -125 psi or 1.4 – 8.8 kg/Centimeter2,
Operating Temperature : 34 – 100° F or 1.1 – 38° C Acceptable Salt Type: Sodium Chloride – Pellet or solar salt for water softeners All Systems above tested at 35psi +/- 5 psi, pH of 7.5 +/- 0.5, Capacity Testing Flow Rate = 50% of the rated service flow rate for the various size systems.

SYSTEM SPECIFICATIONS continued

These water softener systems have been tested by WQA and conform to NSF/ANSI 44 for specific performance claims as verified and substantiated by test data. The rated salt efficiencies above were also determined in accordance with NSF/ANSI 44 and are only valid at the salt dosage referenced above. An efficiency rated water softener is a demand initiated regeneration (DIR) softener which also complies with specific performance specifications intended to minimize the amount of regenerant brine and water used in its operation. Efficiency rated water softeners shall have a rated salt efficiency of not less that 3350 grains of total hardness exchanged per pound of salt (based on NaCl equivalency) (477 grams of total hardness exchanged per kilogram of salt), and shall not deliver more salt than its listed rating. The rated efficiency of the water softener, the salt dosage at that efficiency, the capacity atthat salt dosage and that of the efficiency is only valid at the stated salt dosage. Efficiency is measured by a laboratory test described in NSF/ANSI 44. The test represents the maximum possible efficiency the system can achieve. Operational efficiency is the actual efficiency achieved after the system has been installed. It is typically less than the efficiency due to individual application factors including water hardness, water usage, and other contaminants that reduce the water softener’s capacity. These systems are not intended to be used for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Refer to the system Installation and Service Manuals for set-up and programming instructions. Contact your local Autotrol dealer for parts and service. See your owner’s manual for warranty information.

Important Notice: For conditions of use, health claims certified by the California Department of Public Health and replacement parts, see product data sheet Iowa Requirement

Seller: __
Date:
Buyer: ____

Date:

Grounding Icon Tested and Certified by WQA against NSF/ANSI Standard 44 & NSF/ANSI 372 for “lead free” compliance.
The valve used on this unit is Tested and Certified by WQA to NSF/ANSI Std. 61 Section 8 for Material Safety Only

PENTAIR Residential Filtration, LLC
5730 North Glen Park Road Milwaukee, Wisconsin 53209
PHONE:
(262)-238-4400

EQUIPMENT INSTALLATION

Autotrol 255 Valve Control Module Features

Optional i-lid Cover
Optional i-lid Cover
Figure 1
Product Overview
AUTOTROL 400 Series Demand Controls Instruction Manual

Optional Bypass
Optional Bypass
Figure 2
Product Overview

System Regeneration Cycles

  1. Service (Downflow):
    Untreated water is directed down through the resin bed and up through the riser tube. The hardness ions attach themselves to the resin and are removed from the water. The water is conditioned as it passes through the resin bed.

  2. Backwash (Upflow):
    The flow of water is reversed by the control valve and directed down the riser tube and up through the resin bed. During the backwash cycle, the bed is expanded and debris is flushed to the drain.

  3. Brine/Slow Rinse (Downflow):
    The control directs water through the brine injector and brine is drawn from the regenerant tank. The brine is then directed down through the resin bed and up through the riser tube tothe drain. The hardness ions are displaced by sodium ions and are sent to the drain. The resin is regenerated during the brine cycle. Brine draw is completed when the air check closes.

  4. Fast Rinse (Downflow):
    The control directs water down through the resin bed and up through the riser tube to the drain. Any remaining brine residual is rinsed from the resin bed.

  5. Brine Refill (Downflow):
    Brine refill occurs during a portion of the fast rinse cycle. Water is directed to the regenerant tank at a controlled rate, to create brine for the next regeneration.

  6. Repressurize Cycle — (No Flapper Open):
    This cycle closes all flappers for a short time to allow the air and water to hydraulically balance in the valve before continuing the regeneration.

Figure 3
SERVICE C0
Machine
BACKWASH C1 and C6
Machine
BRINE/SLOW RINSE C2 and C3
Machine
REPRESSURIZE C4
Machine
FAST RINSE5 and C7
Machine
BRINE REFILL C8
Machine

NOTE : All plumbing must conform to local codes. Inspect unit carefully for carrier shortage or shipping damage

Location Selection

  1. The distance between the unit and a drain should be as short as possible.
  2. If it is likely that supplementary water treating equipment will be required, make certain adequate additional space is available.
  3. Since salt must be added periodically to the brine tank, the location should be easily accessible.
  4. Do not install any unit closer to a water heater than a total run of 10 feet (3 m) of piping between the outlet of the conditioner and the inlet to the heater. Water heaters can sometimes overheat to the extent they will transmit heat back down the cold pipe into the unit control valve. Hot water can severely damage the conditioner. A 10 foot (3-m) total pipe run, including bends, elbows, etc., is a reasonable distance to help prevent this possibility. A positive way to prevent hot water from flowing from heat source to the conditioner, in the event of a negative pressure situation, is to install a check valve in the soft water piping from the conditioner. If a check valve is installed, make certain the water heating unit is equipped with a properly rated temperature and pressure safety relief valve. Also, be certain that local codes are not violated.
  5. Do not locate unit where it or it’s connections (including the drain and overflow lines) will ever be subjected to room temperatures under 34°F (1°C) or over 120°F (49°C).
  6. Do not install unit near acid or acid fumes.
  7. The use of resin cleaners in an unvented enclosure is not recommended.

Water Line Connection
The installation of a bypass valve system is recommended to provide for occasions when the water conditioner must be bypassed for hard water or for servicing.

[The most common bypass systems are the Autotrol® Series 256 bypass valve ( Figure 4 ) and plumbed-in globe valves (Figure 5). Though both are similar in function, the 256 Autotrol bypass offers simplicity and ease of operation.
Figure 4 Autotrol Series 256 Bypass Valve

In Bypass

Figure 5 Typical Globe Valve Bypass System
Not in Bypass
Not in Bypass
In Bypass
In Bypass
Drain Line Connection

  1. Ideally located, the unit will be above and not more than 20 feet (6.1 m) from the drain. For such installations, use an appropriate adapter fitting (not supplied), to connect 1/2 inch (1.3 cm) plastic tubing to the drain line connection of the control valve.
  2. If the unit is located more than 20 feet (6.1 m) from drain, use 3/4 inch (1.9 cm) tubing for runs up to 40 feet (12.2 m). Also, purchase appropriate fitting to connect the 3/4 inch tubing to the 1/2 inch NPT drain connection.
  3. If the unit is located where the drain line must be elevated, you may elevate the line up to 6 feet (1.8 m) providing the run does not exceed 15 feet (4.6 m) and water pressure at conditioner is not less than 40 psi (2.76 bar). You may elevate an additional 2 feet (61 cm) for each additional 10 psi (0.69 bar).
  4. Where the drain line is elevated but empties into a drain below the level of the control valve, form a 7-inch (18 cm) loop at the far end of the line so that the bottom of the loop is level with the drain line connection. This will provide an adequate siphon trap.
  5. Where the drain empties into an overhead sewer line, a sink-type trap must be used.

IMPORTANT: Never insert drain line into a drain, sewer line or trap. Always allow an air gap between the drain line and the wastewater to prevent the possibility of sewage being back siphoned into conditioner.
Figure 6
Product Instruction
NOTE:
Standard commercial practices have been expressed here. Local codes may require changes to these suggestions.

Brine Line Connection
It will be necessary to install the brine tube and line to a fitting installed on the air check. Apply plumber tape on all threaded connections.

Be sure all fittings and connections are tight so that prematurechecking does not take place. Premature checking is when the ball in the air check falls to the bottom before all brine is drawn out of the brine tank. See Placing Conditioner into Operation section.

Overflow Line Connection
In the absence of a safety overflow and in the event of a malfunction, the BRINE TANK OVERFLOW will direct “overflow” to the drain instead of spilling on the floor where it could cause considerable damage. This fitting should be on the side of the cabinet or brine tank.

To connect overflow, locate hole on side of brine tank. Insert overflow fitting (not supplied) into tank and tighten with plastic thumb nut and gasket as shown (Figure 7). Attach length of 1/2 inch (1.3 cm) I.D. tubing (not supplied) to fitting and run to drain. Do not elevate overflow line higher than 3 inches (7.6 cm) below bottom of overflow fitting. Do not tie into drain line of control unit. Overflow line must be a direct, separate line from overflow fitting to drain, sewer or tub. Allow an air gap as per drain line instructions ( Figure 6).
Figure 7
Product Instruction

Low Voltage Transformer
Use only the included transformer for powering the 400 series timers. Connect the plug of the transformer secondary cable to the mating socket on the control ( see Figure 8).
Cable
Cable
Be certain that the transformer is plugged into a correct voltage source that is not controlled by a wall switch.

Increasing the Length of the Transformer Cord
If it is necessary to extend the length of the transformer cord, an optional 15 foot (4.6 m) extension is available (see Figure 9).
Control Valve
Figure 9 –
Control Valve

SYSTEM STARTUP

Initial Startup
After the water conditioning system is installed, the conditioner should be disinfected before it is used to treat potable water. Refer to the Disinfection of Water Conditioners section in this manual. Complete the following steps to place the conditioner into operation:

  1. Remove control valve cover.
    NOTE: The following steps will require turning the indicator knob (Figure
  1. to various positions. Insert a  wide-blade screwdriver into arrow slot in indicatorknob and press in firmly. With knob held in, rotate COUNTERCLOCKWISE only until arrow or knob points to desired position. Rotation is made much easier if you grasp the camshaft with your free hand and turn it at the same time. Then permit knob to spring back out.
  1. Insert screwdriver into slot in indicator knob (Figure 11). Press in and rotate knob COUNTERCLOCKWISE until arrow points directly to the word BACKWASH.

  2. Fill resin tank with water.
    a. With water supply off, place the bypass valve(s) into the “NOT IN BYPASS” position.
    b. Open water supply valve very slowly to approximately the 1/4 open position.
    IMPORTANT: If opened too rapidly or too far, resin may be lost. In this position, you should hear air escaping slowly from the drain line.
    c. When all of the air has been purged from the tank (water begins to flow steadily from the drain), open the water supply valve all the way.
    d. Allow water to run to drain until clear.
    e. Turn off water supply and let the unit stand for about five minutes. This will allow all trapped air to escape from the tank.

  3. Add water to brine tank (initial fill). With a bucket or hose, add approximately 4 gallons (15 liters) of water to brine tank. If the tank has a salt platform above the bottom of the tank, add water until the level is approximately 1 inch (25 mm) above the platform.

  4. Put into operation.
    a. Open water supply valve slowly to full open position.
    b. Carefully advance indicator knob COUNTERCLOCKWISE to center of FAST RINSE/REFILL position and hold there until air check (Figure 10) fills with water and water starts to flow through brine line into brine tank. Do not run for more than two minutes.
    c. Advance indicator knob COUNTERCLOCKWISE until arrow points to the center of the BRINE/SLOW RINSE position.
    d. With the conditioner in this position, check to see if  water is being drawn from the brine tank. The waterlevel in the brine tank will recede very slowly. Observe for at least three minutes. If the water level does not recede or goes up, or if air enters the transparent air check chamber and the ball falls and seats, reference Troubleshooting section.
    e. Advance indicator knob COUNTERCLOCKWISE to CONDITIONED WATER.
    f. Run water from a nearby faucet until the water is clear and soft

PROGRAMMING

440i Control (obsolete)
Indicator knob
Figure 10

Programming

  1. Set days of regeneration on skipper wheel (Figure 11).
    • Pull all skipper pins outward (away from control).
    • Rotate skipper wheel until day arrow points to current day or number 1.
    • Depress skipper pin(s) at day(s) for which regeneration is desired.
  2. Set the time of day.
    • Grasp timer knob and pull outward.
    • Rotate in either direction until the timer arrow points to the actual time of day.
    • Release timer knob.

NOTE: With the time of day properly set, the conditioner will regenerate at about 2:30 a.m. If you prefer to have the unit regenerate at an earlier or later time, simply set current time-of-day accordingly (e.g., to have the unit regenerate at 4:30 a.m.—two hours later—set the clock two hours earlier than the actual time of day.)
NOTE: The Timer Locking Pin should always be horizontal ( Figure 11 ) during operation.
Figure 11
Control

Programming
Plug the wall-mount transformer into a functioning electrical outlet that is not controlled by a switch. Plug the transformer into the transformer plug receptacle on the control. Open the access door by pushing the raised tab on the door toward the left while pulling the tab out (Figure 12).

Time of Day Setting
With the jumper on the set of pins next to the word TIME (Figure 13) , set the time of day to the closest hour by pressing the black TIME SET button. PM hours are indicated by a light next to the letters PM on the display window

NOTE: The use of a small needle-nose pliers will aid in moving the jumper.
NOTE: The unit is factory set to regenerate at 2:00 a.m. If you prefer to have the unit regenerate at an earlier or later time, simply set the current time of day accordingly (e.g., to have the unit regenerate at 4:00 a.m.—two hours later—set the clock two hours earlier than the actual time of day).
NOTE: The Timer Locking Pin should always be horizonta l (Figure 12 ) during operation.

Hardness Setting
Move the jumper to the set of pins next to the word HARDNESS (Figure 14). Press the black TIME SET button until the hardness of the incoming water supply is displayed. The hardness range is from 1 to 99 grains per gallon. To change water hardness stated in parts per million (PPM) to grains per gallon (GPG) use this formula:

Parts per Million = Grains Per Gallon
17.

Capacity Setting
Move the jumper to the set of pins next to the word CAPACITY (Figure 15). Press the black TIME SET button until the correct capacity value is displayed. The capacity range is 1 to 99 kilograins. Refer to the Suggested Salt Dial Settings table. Return the jumper to the top set of pins next to the word TIME and replace the access door. The jumper must NOT be left on any pins other than the top pair next to the word TIME. Otherwise, the unit may show a blank display.

NOTE: A spare jumper is located on the bottom set of pins. In the event that the hardness or capacity setting must be changed, simply follow the appropriate steps described above.

Calendar Override Setting

Disconnect power.

  1. Place jumper on Pin A and reconnect power.
  2. Move jumper to Pin B. A zero will appear, indicating zero days of calendar override. All 460i controllers are preprogrammed in this manner at the manufacturer.
  3. Depress the black TIME SET button. The numbers will roll from “0” to “15.” Release the switch at the desired number of days for the calendar override. For example, releasing the switch at “10” would program a 10-day calendar override.
  4. Disconnect power.
  5. Place jumper back on TIME and reconnect power.
  6. The calendar override program is maintained during power outages by the NOVRAM circuitry.
  7. To remove the calendar override, follow the same steps above and program back to “0.”

460TC Control

Figure 15
Control

Programming
Plug the wall-mount transformer into a functioning electrical outlet that is not controlled by a switch. Plug the transformer into the transformer plug receptacle on the control. Open the access door by pushing the raised tab on the door toward the left while pulling the tab out ( Figure 16).

Time of Day Setting
With the jumper on the set of pins next to the word TIME ( Figure 17 ), set the time of day to the closest hour by pressing the black TIME SET button. PM hours are indicated by a light next to the letters PM on the display window.

NOTE: The use of a small needle-nose pliers will aid in moving the jumper.

NOTE: The unit is factory set to regenerate at 2:00 a.m. If you prefer to have the unit regenerate at an earlier or later time, simply set the current time of day accordingly (e.g., to have the unit regenerate at 4:00 a.m.—two hours later—set the clock two hours earlier than the actual time of day).

NOTE: The Timer Locking Pin should alway  be horizontal (Figure 16) during operation.

Days Setting
Move the jumper to the set of pins next to the word DAYS (Figure 18). Press the black TIME SET button until the desired number of days between regeneration is displayed. The range is from 1 to 30 days.

Clock Setting
Move the jumper to the set of pins next to the word CLOCK (Figure 19). Press the black TIME SET button until the desired clock setting is displayed. The clock range is 0 to 1. Select 0 for the standard AM/PM clock or select 1 for a 24 hour clock. Return the jumper to the top set of pins next to the word TIME and replace the access door. The jumper must NOT be left on any pins other than the top pair next to the word TIME. Otherwise, the unit may show a blank display.

NOTE: A spare jumper is located on the bottom set of pins.

Common Features
When using the 255 valve with the 440i or 460i controls, there are several features and procedures that are unique to the 400 series controls. They are as follows:

Salt Dial Adjustment

Table 1 – Suggested Salt Dial Settings (Pounds of Salt) For Various Size Softeners

Capacity Setting (Kilograins)| 0.5 FT 3| 0.75 FT 3| 1.0 FT 3| 1.25 FT 3| 1.5 FT 3| 1.75 FT 3| 2.0 FT 3
12| 4.5| —| —| —| —| —| —
16| 9.0| 5.5| —| —| —| —| —
20| —| 8.5| 6.0| —| —| —| —
24| —| 14.0| 8.5| 7.0| —| —| —
30| —| —| 15.0| 11.0| 9.0| —| —
32| —| —| 18.5| 12.5| 10.0| 9.0| —
35| —| —| —| 16.0| 12.0| 10.0| 9.0
40| —| —| —| 11.5| 17.0| 14.0| 12.0
48| —| —| —| —| 14.0
| 10.5| 17.0
60| —| —| —| —| —| —| 15.0

  • This setting requires the use of “XS” (extra salt) cam and doubles the amount of the setting.

These models may be adjusted to produce maximum to  minimum conditioning capacities by setting the salt dial, which controls the amount of salt used per regeneration. When desired, the minimum setting may be used on installations if the frequency of regeneration is increased to compensate for lower regenerated conditioning capacity. The installing dealer will set the unit for proper salt usage. Further adjustments are needed only if the hardness of the water supply changes or if water use changes dramatically. Capacity will need to be adjusted accordingly.

To adjust salt dosage, insert a small screwdriver into the white indicator knob and move pointer to proper salt setting (Figure 13).

NOTE: To convert the salt settings from English to metric, divide by 2.2 (e.g., 12 pounds ÷ 2.2 = 5.5 kg of salt).

The amount of salt placed in the brine tank has nothing to do  with the amount of salt used during the regeneration cycle. Water will dissolve and absorb salt only until it becomes saturated. A given amount of brine (salt-saturated water) contains a specific amount of salt. The salt dial controls the amount of brine used during the regeneration cycle (e.g., when set at 15 pounds (6.8 kg) the amount of brine the conditioner will use for each regeneration will contain 15 pounds (6.8 kg) of salt, etc.)

Never let the amount of salt in the brine tank be lower than the normal liquid level. Do not overload the brine tank with salt.

Guest Cycle (Manual Regeneration)
When abnormally high water usage exhausts your water conditioner’s capacity ahead of schedule, an extra regeneration can be achieved. Depress the indicator knob on the 440i (Figure 11 ) with a wide-blade screwdriver and turn COUNTERCLOCKWISE to START to initiate a regeneration. For the 460i, simply depress the indicator knob ( Figure 12). It will take a few minutes for regeneration to start. A normal regeneration will take approximately two hours.

SERVICE AND Mainte

Inspect and clean brine tank and screen filter on end of brine pickup tube once a year or when sediment appears in the bottom of the brine tank.

Clean injector screen and injector once a year:

  1. Unplug the wall-mount transformer.
  2. Shut off water supply or put bypass valve(s) into bypass position.
  3. Relieve system pressure by opening valve No. 5 (at rear) with a screwdriver.
  4. Using a screwdriver, remove injector screen and injector cap (Figure 16).
  5. Clean screen using a fine brush. Flush until clean.
  6. Using a needle-nose pliers, pull injector straight out.
  7. Flush water into the injector screen recess of the valve body to flush debris out through the injector recess.
  8. Clean and flush the injector.
  9. Lubricate the o-rings on the injector, injector cap and injector screen with silicone lubricant.
  10. Reinstall the injector, injector cap and injector screen. See IMPORTANT note.
  11. Plug the wall-mount transformer into outlet; reset time of day.
  12. Slowly open water supply valve or return bypass valve(s) to the “not in bypass” position

IMPORTANT: Do not overtighten the plastic cap. Seat the cap lightly into position. Overtightening may cause breakage of the plastic cap that may not be immediately evident
Figure 20
Installation

Disinfection Of Water Conditioners
The materials of construction of the modern water conditioner will not support bacterial growth, nor will these materials contaminate a water supply. During normal use, a conditioner may become fouled with organic matter, or in some cases with bacteria from the water supply. This may result in an off-taste or odor in the water.

Some conditioners may need to be disinfected after installation and some conditioners will require periodic disinfection during their normal life.

Depending upon the conditions of use, the style of conditioner, the type of ion exchanger, and the disinfectant available, a choice can be made among the following methods.

Sodium or Calcium Hypochlorite Application
These materials are satisfactory for use with polystyrene resins, synthetic gel zeolite, greensand and bentonites.

5.25% Sodium Hypochlorite
These solutions are commonly known as household bleach. If stronger solutions are used, such as those sold for commercial laundries, adjust the dosage accordingly.

  1. Dosage
    g. Polystyrene resin; 1.2 fluid ounce (35.5 ml) per cubic foot.
    h. Non-resinous exchangers; 0.8 fluid ounce (23.7 ml) per cubic foot.

  2. Brine tank conditioners
    a. Backwash the conditioner and add the required amount of hypochlorite solution to the well of the regenerant tank. The regenerant tank should have water in it to permit the solution to be carried into the conditioner.
    b. Proceed with the normal regeneration

Calcium Hypochlorite
Calcium hypochlorite, 70% available chlorine, is available in several forms including tablets and granules. These solid materials may be used directly without dissolving before use.

  1. Dosage
    a. Two grains (approximately 0.1 ounce [3 ml]) per cubic foot.

  2. Regenerant tank conditioners
    a. Backwash the conditioner and add the required amount of hypochlorite to the well of the regenerant tank. The regenerant tank should have water in it to permit the chlorine solution to be carried into the conditioner.
    b. Proceed with the normal regeneration.

255 Valve & Tank Adapter module
Product Parts

255 Valve & Tank Adapter module 

255 Seri

Product Instruction
Product Instruction
NOTE: Do not use pipe joint compound when threading pipe into the Noryl piping boss. Use only plumber pipe tape. Do not overtighten pipe into Noryl piping boss.

Troubleshooting

The technology upon which the Series 255 control is based is well established and proven in service over many years. However, should a problem or question arise regarding the operation of the system, the control can be very easily serviced. The control module can be quickly replaced or adjustments can be made at the installation. We recommend that you contact your local professional water treatment dealer for most concerns. For parts mentioned, refer to exploded views in the Replacement Parts section of this manual

IMPORTANT: Service procedures that require the water pressure to be removed from the system are marked with a ! after the possible cause. Refer to Preventative Maintenance section for instructions.

Valve Troubleshooting

Problem Cause Correction
Brine tank overflow. Uncontrolled brine refill flow rate. Remove brine

control to clean ball and seat.
Air leak in brine line to air check.| Check all connections in brine line for leaks. Refer to instructions.
Drain control clogged with resin or other debris.| Clean drain control.
Flowing or dripping water at drain or brine line after regeneration.| Valve stem return spring weak.| Replace spring. (Contact dealer.)
Hard water leakage after regeneration.| Improper regeneration.| Repeat regeneration after making certain correct salt dosage was set.
Leaking of external bypass valve.| Replace bypass valve. (Contact dealer.)
O-ring around riser pipe damaged.| Replace o-ring. (Contact dealer.)
Control will not draw brine.| Low water pressure.| Make correct setting according to instructions.
Restricted drain line.| Remove restriction.
Injector plugged !| Clean injector and screen.
Injector defective !| Replace injector and cap. (Contact dealer.)
Valve disc 2 and/or 3 not closed.| Remove foreign matter from disc and check disc for closing by pushing in on stem. Replace if needed. (Contact dealer.)
Air check valve prematurely closed.| Put control momentarily into brine refill. Replace or repair air check if needed. (Contact dealer.)

255/440i Troubleshooting

Problem Cause Correction
No water flow display when water is flowing. Bypass valve in bypass. Shift

bypass valve to not-in-bypass position.
Meter probe disconnected or not fully connected to meter housing.| Fully insert probe into meter housing.
Restricted meter turbine rotation due to foreign material in meter !| Remove meter housing, free up turbine and flush with clean water. Turbine should spin freely. If not, replace meter. (Contact dealer.)
Defective meter probe.| Replace meter cable (no meter cable for the 460TC) (Contact dealer.)
Continuous regeneration. Camshaft does not stop at the end of regeneration.| Misaligned optical sensor.| Replace optical sensor (no sensor for the 460TC). (Contact dealer.)
Run out of soft water between regenerations.| Improper regeneration.| Repeat regeneration, making certain that correct salt dosage is used.
Incorrect salt setting.| Set salt control to proper level. See salt setting chart.
Incorrect hardness or capacity settings.| Set to correct values. See Programming section.
Water hardness has increased.| Set hardness or days to new value. See Programming section.
Restricted meter turbine rotation due to foreign material in meter !| Remove meter housing, free up turbine and flush with clean water. Turbine should spin freely; if not, replace meter. (Contact dealer.)

FLOW DIAGRAMS

Service Position
Valve No.

  1. Closed
  2.  Open
  3.  Open
  4. Closed
  5. Closed
  6. Closed

Backwash Position

Valve No.

  1. Open
  2. Closed
  3. Closed
  4. Open
  5. Open
  6. Closed

Brining Position

Valve No.

  1. Closed
  2. Closed
  3. Open
  4. Open
  5. Closed
  6. Open

Slow Rinse Position

A Valve No.

  1. Open
  2. Closed
  3. Closed
  4. Open
  5. Open
  6. Closed

Repressurize Position

Valve No.

  1. Closed
  2. Closed
  3. Closed
  4. Open
  5.  Closed
  6. Closed

Fast Rinse Position

Valve No.

  1. Open
  2. Open
  3. Open
  4. Closed
  5. Closed
  6. Closed

Brine Refill Position

Valve No.

  1. Closed
  2. Open
  3. Closed
  4. Open
  5. Open
  6. Closed

FLOW DATA CHARTS

255 Valve Flow Data
Data Chart

Injector Performance Graphs

**Injector “F” (Peach) For 7-inch Tanks

**

Injector “G” (Tan) For 8-inch Tank
Data Chart

Injector “H” (Light Purple) For 9-inch Tanks

Injector “J” (Light Blue) For 10-inch Tanks

**Injector “K” (Pink)  For 12-inch Tanks

Injector “L” (Orange) For 13- and 14-inch Tanks

**

Charger Water Treatment Products
8150 N. Lehigh Ave, Morton Grove, IL 60053
www.chargerwater.com/FAQcharger
Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals