Nasco HEALTHCARE 100-2160 Econo VTA CPR Trainer Instruction Manual

June 12, 2024
Nasco HEALTHCARE

Nasco-HEALTHCARE-LOGO

Nasco HEALTHCARE 100-2160 Econo VTA CPR Trainer

Nasco-HEALTHCARE-100-2160-Econo-VTA-CPR-Trainer-PRODUCT-
IMG

Product Information

  • Product Name: Econo VTA (Visual Training Assistant) CPR Trainer 100-2160
  • Manufacturer: Nasco Healthcare
  • Address: 16 Simulaids Drive, Saugerties, NY 12477
  • Contact: 1-833-NASCOHC (627-2642), [email protected].
  • Website: www.nascohealthcare.com
  • Revision: HC190012INS1 06/21

Product Usage Instructions

Please follow the instructions below for proper usage of the Econo VTA CPR Trainer:

Step 1: Preparation

  1. Ensure that the product is placed on a stable and flat surface.
  2. Check if the product color, materials, supplies, and function match the description in the user manual.
  3. If there are any discrepancies or concerns, contact Nasco Healthcare for assistance.

Step 2: Training Setup

  1. Connect the necessary cables and power supply to the CPR Trainer.
  2. Refer to the user manual for detailed instructions on connecting the cables.
  3. Make sure all connections are secure and properly inserted.

Step 3: Simulator Operation

  1. Press the power button to turn on the CPR Trainer.
  2. Follow the on-screen instructions and prompts to navigate through the simulator’s menu.
  3. Utilize the visual training assistant features to practice CPR techniques.

Step 4: CPR Training

  1. Place the manikin in the correct position for CPR training.
  2. Refer to the user manual for proper positioning guidelines.
  3. Perform CPR techniques following the instructions provided by the visual training assistant.

Step 5: Post-training Steps

  1. After training, turn off the CPR Trainer by pressing the power button.
  2. Disconnect any cables and power supply from the device.

For any further assistance or inquiries, please refer to the user manual or contact Nasco Healthcare directly.

About the Simulator

Nasco-HEALTHCARE-100-2160-Econo-VTA-CPR-Trainer-FIG-1

  • The VTA box with light indicators runs on a 9V DC battery installed in the back of the VTA box. To turn it on, slide the switch to the on position. The lights that indicate the correct depth and correct rate will blink while the VTA box is orienting and calibrating. Compressions can begin once the lights stop blinking.
  • The depth and rate are set to AHA 2015 standards. When the correct depth (2-2.5 inches) and the proper release is achieved, the light will stay illuminated. If the release is not correct after a compression the compression is not counted and the counted compression rate drops. The compression rate has to be within 100- 120 for the rate light to be on.
  • The replaceable lung bag allows for 2 breaths for every 30 compressions but is not measured. If rescue breathing is part of the training it is recommended replacing the lung bag between students. Follow the directions for lung bag replacement outlined in the instructions for the Economy Adult Sani-Manikin. Replace the 9V DC battery when the light indicators fail to illuminate on the VTA box.
  • Actual product may vary slightly from the photo. Nasco Healthcare reserves the right to change product color, materials, supplies, or function as needed.

Nasco Healthcare

©2021 Nasco Healthcare. HC190012INS1 06/21.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Nasco HEALTHCARE User Manuals

Related Manuals