endeavour Tools ET6797 Replacement 12V Jump Starter Cable Instruction Manual
- June 12, 2024
- Endeavour Tools
Table of Contents
- endeavour Tools ET6797 Replacement 12V Jump Starter Cable
- Product Information
- SAFETY WARNINGS
- PRODUCT OVERVIEW
- VEHICLE JUMP START INSTRUCTIONS
- MANUAL ACTIVATION / RESET BUTTON
- MOBILE PHONE /TABLET / PC CHARGING
- SPECIFICATIONS
- WARRANTY STATEMENT
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
endeavour Tools ET6797 Replacement 12V Jump Starter Cable
Read all safety warnings and instructions. Failure to follow warnings and instructions may result in electric shock, re, and/or serious injury. FOR 12V AUTOMOTIVE BATTERIES ONLY.
Product Information
- Product Model: ET6797
- Product Name: 1,400A Peak CCA Jump Starter | Power Bank
- Product Overview:
- ON/OFF button
- USB output
- DC15V input
- 1W LED light
- DC12~16V output
- Battery indicator
- EC5 output/Dust cover
SAFETY WARNINGS
- Use only the 240V adaptor supplied with this unit. Do not modify this adaptor in any way.
- Do not expose this unit to rain or wet conditions. Water entering this unit risks electric shock. If use in a damp location is unavoidable, use a residual current device (RCD) protected supply.
- Do not use this unit in explosive atmospheres, for example, in the presence of gases, dust or
- Do not allow children to use this unit, especially because the device has large current discharge characteristics.
JUMPSTART USAGE
- When using the jump start function, do not allow the positive and negative poles to contact each other. This may cause sparking and result in a safety hazard, and cause a short circuit of the unit.
- When using the jump start function, use for 3 seconds only. Allow 1 minute for unit to cool before attempting a further jump start. Disconnect the cable from the unit immediately upon engine starting.
- Use only the jump start cables supplied with this unit.
BATTERY
- This unit contains a lithium polymer battery. Always comply with transport and safety regulations in the use and disposal of such batteries.
- Do not open this unit. Opening may break or damage the components, and will void the warranty.
- Do not store in a location where the temperature may exceed 70oC. Charge only in temperatures between 0oC and 60oC.
PRODUCT OVERVIEW
- ON/OFF button
- USB output
- DC15V input
- 1W LED light
- DC12~16V output
- Battery indicator
- EC5 output/Dust cover
BATTERY INDICATOR
Press the POWER button to power ON the unit. The BATTERY CAPACITY indicator
will light up. If no device is connected to the unit, it will power off
automatically. When charging this unit, the battery indicator lights will
flash indicating the charging level. When all lights are on, the charging
process is complete.
VEHICLE JUMP START INSTRUCTIONS
- Use this unit with 12V automotive batteries ONLY, with a CCA rating of 1400CCA or less.
- Use the supplied ET6797 SMART START cable ONLY with this ET6797 jump starter. Do NOT connect this SMART START cable to any other jump starter. Do NOT connect this SMART START cable to any battery with a voltage greater than 15V. Do NOT use any other jump start cables with this unit
- This unit is for emergency jump starts ONLY. Do NOT use as a replacement for the car battery.
In order to avoid damage to this unit, do not attempt to repeatedly start the vehicle. If the vehicle does not immediately start, you must wait for at least one minute to allow the unit to cool down. As additional protection, the SMART START starts actions, or b) after 90 seconds. Please refer to the MANUAL ACTIVATION / RESET button section below for instructions on resetting the cable.
-
A. Make sure that the jump start unit has two or more power indicator lights on (to ensure it has sufficient charge to jump start the vehicle). If the jump start capacity is too low when you connect the SMART START cable, the indicator light will flash red. Recharge the unit.
-
B. Open the DUST COVER and insert the SMART START cable into the EC5 port on your jump start unit.
-
C. Connect the red alligator clip on the SMART START cable to the red battery positive pole (+) and the black alligator clip to the black negative battery pole (-).
-
D. The jump start unit should now be ready to start the car. The green indicator light will light up solidly. This indicates that the connection is correct, and you may now attempt to turn your ignition key to start the engine. Do this within 30 secs. Otherwise the SMART START cable will automatically disconnect and will need to be reset.
When the green indicator lights up solidly, the jump starter is active. Do not disconnect the battery clamps from the battery to avoid risk of electric shock. -
E. If the SMART START cable detects a problem, the indicator light will turn RED. The problems may be due to (a) a short circuit, (b) a reverse polarity connection, (c) over current, or (d) over temperature. The SMART START cable will also not function if the battery voltage is less than 3V. Correct the problem first, then hold down the RESET button for 5 seconds to start again.
-
F. After jump starting the vehicle, immediately remove the SMART START cable from the jump starter and then remove the cable from the car battery.
MANUAL ACTIVATION / RESET BUTTON
The SMART START cable provides important safety protections. These include short circuit protection, reverse charging protection and reverse polarity protection. The SMART CABLE will also automatically disconnect (in which case the indicator light will flash green):
-
After after no activity for 90 seconds;
Solution: Depress the MANUAL ACTIVATION / RESET button for 5 seconds to reset the cable. The green light will light up solid. Refer from (D) above. -
The car battery voltage is less than 3V;
Solution: The jump start unit will not start automatically. Override this protection by depressing the MANUAL ACTIVATION / RESET button for 5 seconds. Refer from (D) above. -
A short circuit or reverse polarity situation is detected;
Solution: Resolve the problem first. Then press the MANUAL ACTIVATION / RESET button for 5 seconds to reset the cable. The green indicator light will light up solid. Refer from (D) above.
Only use the MANUAL ACTIVATION / RESET button when a problem has been detected, and after you have resolved the issue causing the problem. Pressing the MANUAL ACTIVATION / RESET button will cause the REVERSE POLARITY protection to be DISABLED until such time as the SMART CABLE is physically disconnected / reconnected to the jump start unit. Be very careful NOT to reverse the polarity once the RESET button has been pressed. Otherwise you may cause damage to the cable and the jump start unit.
MOBILE PHONE /TABLET / PC CHARGING
We recommend using the charging cable supplied with your original product. For phones / tablets, plug the USB port of the charging cable into the USB 5V output port, and the adaptor to your device. The 12V DC connection can be used for charging 12V devices. The maximum output current is 15A.
RECHARGING THIS UNIT
Press the POWER switch to start charging. This unit should be charged using
the 240V AC (15V / 1A) adaptor supplied. Using the 240V AC adaptor, it will
take approximately 6 hours to fully charge the unit. To extend the battery
life, it is recommended to fully charge the unit every 3 – 6 months.
LED LIGHTS
Further pressing the power switch will cycle between SOS mode, flashing mode,
and then off. Depress the POWER switch for 3 seconds to directly turn off the
LED light.
SPECIFICATIONS
- Capacity 20,000mAh
- Peak current 1400CCA
- Charging DC15V/1A (6 hrs)
- USB output USB5V1A + USB5V2.1A
- DC output 12V – 16V/15A
- Working temperature -20oC to 60oC
- Storage temperature -20oC to 60oC
WARRANTY STATEMENT
Endeavour Tools guarantees this unit against defects in material and workmanship for a period of twelve (12) months from the date of purchase. This warranty excludes consumable items in the kit.
- A. Endeavour Tools warrants the quality of these goods against defects in material and workmanship only.
- B. Defective goods shall only be replaced, repaired or purchase price refunded if:
- a. The customer notifies Endeavour Tools by providing a full report describing the defect in writing within 7 days of the discovery of the defect; and
- b. The notification above provided to Endeavour Tools is prior to the expiry of the warranty period;
- c. The customer forwards the defective goods together with proof of purchase from Endeavour Tools or its authorized distributor at their expense, within 14 days of any request by Endeavour Tools to do so;
- d. The goods since the date of delivery to the customer have been properly maintained, stored and housed and the goods have not been abused or modified or the case opened; and the use of a defective material.
- C. Endeavour Tools may replace or repair the defective good (or part thereof) or refund the purchase price of the defective good at its option.
- D. Endeavour Tools shall not be responsible for any loss or damage arising from or in any way connected with the use of the goods.
- E. To the maximum extent permitted by law, a claim in respect to a defective good shall not be permitted in the event that the goods have not been installed, used, maintained, or housed in a proper and workmanlike manner or in accordance with the usual standards or manufacturers specifications or instructions or if the goods have been modified, repaired or altered by any person apart from Endeavour Tools.
Notwithstanding our warranty terms above, our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. The benefits under our warranty are in addition to other rights and remedies under law in relation to the goods.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>