Haier 24KC-HSU-24KCSOC Split Type Room Air Conditioner Instruction Manual
- June 12, 2024
- Haier
Table of Contents
SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
24KC-HSU-24KCSOC Split Type Room Air Conditioner
- Please read this operation manual before using the air conditioner.
Keep this operation manual for future reference.
0010579916
**Cautions
**
WARNING
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper
works may cause electric shock, fire, water leakage.
- If the supply cord is damaged. it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- This appliance is not intended for use by persons (including children) with reduced physical. sensory or mental capabilities. or lath of experience and knowledge. unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- The appliances are not intended to be operated by means of an external timer or separate remote-control system.
- Keep the appliance and its cord out of reach of children less than 8 years.
- The appliance shall be installed in accordance with national wiring regulations.
- Means for disconnection. such as circuit breaker. which can provide full disconnection in all poles. must be incorporated in the fixed wiring in accordance with the wiring rules. Details of type and rating of fuses. or rating of circuit breakers / ELB is detailed in below part.
- The method of connection of the appliance to the electrical supply and interconnection of separate components is detailed in below part. The wiring diagram with a clearindication of the connections and wiring to external control devices and supply cord is detailed in below part. The size and type of the cord is detailed in below part.
- The information of dimensions of the space necessary for correct installation of the appliance including the minimum permissible distances to adjacent structures is detailed in below part.
- Instructions on addition charging of refrigerants are detailed in below part.
- To avoid danger of suffocating.keep this plastic bag away from babies and children.Do not use this bag in cribs.beds.carriages or playpens.This is not a toy.
WARNING
When abnormality such as burnt-small found, immediately stop the operation
button and contact sales shop.| Use an exclusive power source with a circut
breaker| Check proper installation of the drainage securely
---|---|---
Connect power supply cord to the outlet completely| Use the proper voltage| Do
not use power supply cord in a bundle.
Take care not to damage the power supply cord| 1. Do not use power supply
cord extended or connected in halfway
2. D0 not install in the place where there is any possibilty of inflammable
gas leakage around the unit.
3. Do not get the unit exposed to vapor or oil steam.| Do not start or stop
the operation by disconnecting the power supply cord and so on
Do not channel the air flow directly at people, especially at infants or the
aged| Do not try to repair or reconstruct by yourself.| Connect the earth
cable.
Do not insert objects into the air inlet or outlet| |
CAUTION
Do not use for the purpose of storage of food, art work, precise equipment,
breeding, or cultivation.| Take fresh air occasionally especially when gas
appliance is running at the same time.| Do not operate the switch with wet
hand.
---|---|---
Do not place animals or plants in the direct path of the air flow| Do not
install the unit near a fireplace or other heating apparatus.| Check good
condition of the installation stand
Do not pour water onto the unit for cleaning| Do not place any objects on or
climb on the unit.| Do not place flower vase or water containers on the top of
the unit.
Parts and Functions
Indoor Unit Display board A
- Signal receiver
- Tempddisplay
- Operation mode indicator
Display board B
- Signal receiver hole
- Temp. display
- Operation mode indicator (lights up when the compressor is on.)
- TIMER ON/OFF display
TIMER ON= OFF display
SLEEP display
Display board C
- Remote signal receiver (A beeping sound is generated when a signal from remote contrller isreceived.)
- Power indicator (Lights up when unit starts.)
- Timer mode indicator (Lights up whenTimer operation is selected.)
- Operation mode indicator (lights up when the compressor is on.)
- Temp display
Display board D
- Signal receiver hole
- Temp.display
- O cooL display
- HEAT display
- HEALTH display
- DRY display
Actual inlet grille may vary from the one shown in the manual according to the
product purchased
Outdoor Unit
- ouTLET
- INLET
- CONNECTING PIPING AND ELECTRICAL WIRING
- DRAIN HOSE
Remote controller
Remote controller A: Cooling capacity test guidance:Step 1,press the button “ON/OFF”; step 2,press the button “COOL”;step 3,press the button “TURBO”.
-
Mode display
Operation mode| AUTO| COOL| DRY| FAN
---|---|---|---|---
Remote controller| | | | -
Signal sending display
-
SWING display
-
FAN SPEED display
-
LOCK display
-
TIME OFF display
TIME ON display -
TEMP display
-
Additional functions display
Operation mode| QUIET| SLEEP| Supplemented electrical heating| HEALTH| TURBO
---|---|---|---|---|---
Remote controller| | | | | -
TURBO button Fan speed reach the mix value
-
FAN button
-
COOL button
-
SWING LEFT/RIGHT button
-
FAN SPEED button
-
HEALTH button
-
SLEEP button
-
LOCK button
-
LIGHT button
Control the lightening and extinguishing of the indoor LED display board. -
POWER ON/OFF button
-
DRY button
-
TEMP button
-
TIME OFF/ON button
-
SWING UP/DOWN button
-
EXTRA FUNCTION button
Function: HEALTH AIRFLOW AUTO FAN -
CANCEL/CONFIRM button
Function: Setting and cancel to the timer and other additional functions. -
RESET button
When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote.
Healthy function is not available for some units.
Remote controller B: Cooling capacity test guidance:Follow remote
controller A. Heating capacity test guidance:Step 1,press the button “ON/OFF”;
step 2,press the button “HEAT”;step 3,press the button “TURBO”.
-
Mode display
Operation mode| AUTO| COOL| DRY| FAN| HEAT
---|---|---|---|---|---
Remote controller| | | | | -
Signal sending display
-
SWING display
-
FAN SPEED display
-
OCK display
-
TIME OFF display
TIME ON display -
TEMP display
-
Additional functions display
Operation mode| QUIET| SLEEP| Supplemented electrical heating| HEALTH| TURBO
---|---|---|---|---|---
Remote controller| | | | | -
TURBO button Fan speed reach the mix value
-
HEAT button
-
COOL button
-
SWING LEFT/RIGHT button
-
FAN SPEED button
-
HEALTH button
-
SLEEP button
-
LOCK button
-
LIGHT button
Control the lightening and extinguishing of the indoor LED display board. -
POWER ON/OFF button
-
DRY button
-
TEMP button
-
TIME OFF/ON
-
SWING UP/DOWN button button
-
EXTRA FUNCTION button
Function: HEALTH AIRFLOW AUTO FAN -
CANCEL/CONFIRM button
Function: Setting and cancel to the timer and other additional functions. -
RESET button
When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote.
Healthy function is not available for some units.
Operation
Base Operation
-
Unit start
Press ON/OFF on the remote controller, unit starts. -
Select temp.setting
Press TEMP4 / TEMPw button
TEMP Every time the button is pressed, temp.setting increase 1°C,if kept depressed, it will increase rapidly
TeMP Every time the button is pressed, temp.setting decrease 1°C,if kept depressed, it will decrease rapidly
Select a desired temperature. -
Fan function
Remote controller A: Press FAN button.
Remote controller B: Press button to enter additional options, when cycle
display to will flash. And then press enter to FAN function.
For each press button fan speed
changes as follows:
Remote controller: Air
conditioner is running under displayed fan speed. When FAN is set to AUTO, the
air conditioner automatically adjusts the fan speed according to room
temperature.
Operation Mode | Controller | Remote Note |
---|---|---|
AUTO | Under the mode of auto operation, air conditioner will automatically |
select Cool or Heat operation according to room temperature. When FAN is set
to AUTO. the air conditioner automatically adjusts the fan speed according to
room temperature.
COOL| | Cooling only unit do not have displays and functions related with
heating
DRY| | In DRY mode, when room temperature becomes lower than
temp.setting+2=C,unit will run intermittently at LOW speed regardless of FAN
setting.
HEAT| | In HEAT mode,warm air will blow out after a short period of the time
due to cold-draft prevention function.
FAN| | In FAN operation mode, the unit will not operate in COOL or HEAT mode
but only in FAN mode AUTO is not available in FAN mode.And temp.setting is
disabled.
When FAN is set to AUTO. the air conditioner automatically adjusts the fan
speed according to room temperature. In FAN mode.SLEEP operation is not
available.
Emergency operation and test operation
Emergency Operation:
- Use this operation only when the remote controller is defective or lost, and with function of emergency running, air conditoner can run automatically for a while.
- When the emergency operation switch is pressed, the ” Pi ” sound is heard once, which means the start of this operation.
- When power switch is turning on for the first time and emergency operation starts, the unit will run automatically in the following modes:
Room temperature| Designated temperature| Timer mode| Fan speed| Operation
mode
---|---|---|---|---
Above 23 °C| 26 °C| No| AUTO| COOL
- It is impossible to change the settings of temp. and fan speed,It is also not possible to operate in timer or dry mode.
Test operation:
Test operation switch is the same as emergency switch.
- Use this switch in the test operation when the room temperature is below 16 °C, do not use it in the normal operation.
- Continue to press the test operation switch for more than 5 seconds . After you hear the “Pi” sound twice, release your finger from the switch: the cooling operation starts with the air flow speed “Hi”.
- Under this operation mode,the fan motor of indoor unit will run in high speed.
Air Flow Direction Adjustment
-
Status display of air flow Vertical flap
Pos.1 (Auto swing)
Pos.2 No initial state disaplayed on remote controller, the vertical flap will be fixed on the current position -
Left and right air flow adjustment
For each press of button, remote controller
displays as follows:
remote controller:
Cautions:
- When adjusting the flap by hand,turn off the unit.
- When humidity is high,condensate water might occur adjusted to left or at air outlet if all vertical louvers are right.
- It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY mode, otherwise, condensate water might occur.
Comfortable SLEEP
Press button , the remote controller will show , and then achieve to the sleep
function. Press again this button , the sleep function will be cancelled.
Operation Mode
-
In COOL,DRY mode
1 hours after SLEEP mode starts,temp. will become 1 °C higher than temp.setting.After another 1 hours, temp.risesby 1 futher .The unit will run for further 6 hours then stops Temp. is higher than temp.setting so that room temperature won’t be too low for your sleep. -
In HEAT mode
1 hours after SLEEP mode starts, temp will become
2 C lower than temp.setting. After another 1 hours, temp decrease by 2 °C further. After more another 3 hours, temp.risesby 1 °C further.The unit will run for further 3 hours then stops.Temp. is lower than temp. setting so that room temperature won’t be too high foryour sleep. -
In AUTO mode
The unit operates in corresponding sleep mode corresponding sleep mode adapted to the automatically selected operation mode. -
In FAN mode
It has no SLEEP function. -
When quiet sleeping function is set to 8 hours the quiet sleeping time can not be adjusted.When TIMER function is set,the quiet sleeping function can’t be set up.After the sleeping function is set up,if user resets TIMER function, the sleeping function will be cancelled; the machine will be in the state of timing-on,if the two modes are set up at the same time,either of their operation time is ended first,the unit will stop automatically,and the other mode will be cancelled.
Note
When TIMER function is set, the sleeping function can’t be set up .After the
sleeping function is set up,if user resets TIMER function, the sleeping
function will be cancelled; the machine will be in the state of timing-on.
Note to the power failure resume:
press the sleep button ten times in five seconds and enter function after
hearing four sounds.And press the sleep button ten times within five seconds
and leave this function after hearing two sounds.
Power Failure Resume Function
If the unit is started for the first time, the compressor will not start
running unless 3 minutes have elapsed. When the power resumes after power
failure, the unit will run automatically, and 3 minutes later the compressor
starts running.
Healthy airflow Operation
-
Press to starting
Setting the comfort work conditions. -
The setting of healthy airflow function
Press button to enter additional options,Press this button continuously, the louvers location will cycle between in the following three locations, to choose the swing location what you needed,and then press button to confirm. -
The cancel of the healthy airflow function
Press button to enter additional options,Press this button continuously, the louvers location will cycle between in the following three locations again,and then press button to cancel.
Notice: Do not direct the flap by hand. Otherwise, the grille will run
incorrectly. If the grille is not run correctly, stop for a minute and then
start, adjusting by remote controller.
Note:
- After setting the healthy airflow function, the position grill is fixed.
- In cooling, it is better to select the mode.
- In cooling and dry, using the air conditioner for a long time under the high air humidity, condensate water may occur at the grille .
Time On/Off On-Off Operation
-
After unit starts, select your desired operation mode.
-
Press / button to change TIMER mode.
Press button ” ON 0.5 ” will appear ,after 10 seconds the time display will be blank.
Press button ” OFF0.5 ” will appear ,after 10 seconds the time display will be blank.
Then select your desired TIMER mode (TIME ON or
TIME OFF ). ” “or ” “will flash. -
Press / button to set time.
Press the button for each time, setting time in the first 12 hours increased by 0.5 hour every time, after 12 hours,increased by 1 hour every time. -
Confirm timer setting
After adjust the time,press button and confirm the time ON or OFF button will not flash any more. -
Cancel timer setting
Press the button the time display eliminated.
Hints:
After replacing batteries or a power failure happens, time setting should be
reset.
According to the Time setting sequence of TIME ON or TIME OFF, either Start-
Stop or Stop-Start can be achieved.
HEALTH Operation (This function is unavailable on some models.)
Press HEALTH button , the remote controller will show and then achieve to the
health function.
Press again this HEALTH button , the health function will be cancelled.
The anion generator in the airconditioner can generate a lot of anion
effectively balance the quantity of position and anion in the air and also to
kill bacteria and speed up the dust sediment in the room and finally clean the
air in the room.
TURBO Operation (This function is unavailable on some models.)
TURBO Operation
When you need rapid heating or cooling, you can use this function. Press TURBO
button, the remote controller will show , and then achieve to the turbo
function. Press again this TURBO button , the turbo function will be
cancelled.
Note
- During TURBO operation, in rapid COOL mode,the room will show inhomogeneous temperature distribution.
- The “TURBO” button will make the fan speed of the indoor unit reach the maximum value. The nameplate nominal value is tested in this mode.
Loading of the battery
- Remove the battery cover;
- Load the batteries as illustrated. 2 R-03 batteries, resetting key (cylinder);
- Be sure that the loading is in line with the” + “/”-“;
- Load the battery,then put on the cover again.
Note:
- The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well.
- When electronic-started type fluorescent lamp or change- over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals, so the distance to the indoor unit should be shorter.
- Full display or unclear display during operation indicates the batteries have been used up. Please change batteries.
- If the remote controller can’t run normally during operation, please remove the batteries and reload several minutes later.
Maintenance
For Smart Use of The Air Conditioner
Setting of proper room temperature| Do not block the air inlet or
outlet| Close doors and windows during
operation
---|---|---
Use the timer effectively| If the unit is not to be used for a long time, turn
off the power supply main switch.| Use the louvers effectively
Remote Controller Do not use water ,wipe the controller with a dry
cloth.Do not use glass cleaner or chemical cloth.
Indoor Body Wipe the air conditioner by using a soft and dry cloth.For
serious stains,use a neutral detergent diluted with water.Wring the water out
of the cloth before wiping.then wipe off the detergent completely.
Do not use the following for cleaning Gasoline,benzine, thinner or
cleanser may damage the coating of the unit. Hot water over 40°C(104°F) may
cause discoloring or deformation.
Air Filter cleaning
-
Open the inlet grille by pulling it upward.
-
Remove the filter. Push up the filter’s center tab siightly unti i is released from the stopper, and remove the fiter downward.
-
Clean the fiter.
Use a vacuum cleaner to remove dust, or wash the fiter with water.
After washing, dry the fiiter completely in the shace. -
Attach the filter. Attach the fiter correctly so that the “FRONT” indication is facing 10 the front Make sure that the ftr is completely fixed behind the slopper.If the right and left fiters are not attached correctly, that may cause defeds.
-
Close the inlet grille.
Replacement of Air Purifying Filter
(NOTE: Air purifying filter is optional part)
-
Open the lnlet Grille Prop up the inlet grille by using a small device named grille-support which located in the right side of the indoor unit.
-
Detach the standard air filter Slide the knob slightly upward to release the filter, then withdraw it.
-
Attach Air Purifying Filter Put air purifying filter appliances into the right and left filter frames.
-
Attach the standard air filter (Necessary installation) ATTENTION:
The white side of the photocatalyst air purifying filter face outside,and the black side face the unit. The green side of the bacteria-killing medium air purifying filter face outside, and the white side face the unit. -
Close the Inlet Grille
Close the Grille surely
NOTE:
- The photocatalyst air purifying filter will be solarized in fixed time. In normal family, it will be solarized every 6 months.
- The bacteria-killing medium air purifying filter will be used for a long time,no need for replacement. But in the period of using them ,you should remove the dust frequently by using vacuum cleaner or flaping them lightly,otherwise , its performance will be affected.
- Please keep the bacteria-killing medium air purifying filter in avoid long time directly sunshine the cool and dry conditions when you stop using it,or its ability of sterilization will be reduced.
Trouble shooting
Before asking for service, check the following first.
| Phenomenon| Cause or check points
---|---|---
Normal Performance inspection| The system does not restart immediately.| •
When unit is stopped, it won’t restart immediately until 3 minutes have
elapsed to protect the system.
• When the electric plug is pulled out and reinserted, the protection circuit
will work for 3 minutes to protect the air conditioner.
Noise is heard| • During unit operation or at stop, a swishing or gurgling
noise may be heard.At first 2-3 minutes after unit start, this noise is more
noticeable (This noise is generated by refrigerant flowing in the system.)
• During unit operation, a cracking noise may be heard.This noise is generated
by the casing expanding or shrinking because of temperature changes.
• Should there be a big noise from air flow in unit operation, air filter may
be too dirty.
Smells are generated.| • This is because the system circulates smells from the
interior air such as the smell of furniture, paint, cigarettes.
Mist or steam are blown out.| • During COOL or DRY operation, indoor unit may
blow out mist.
This is due to the sudden cooling of indoor air.
In dry mode, fan speed can’t be changed.| • In DRY mode, when room temperature
becomeslower than temp.setting+2°C,unit will run intermittently at LOW speed
regardless of FAN setting.
Multiple check| | • Is power plug inserted?
• Is there a power failure?
• Is fuse blownout?
Poor cooling| • Is the air filter dirty?
Normally it should be cleaned every 15 days.
• Are there any obstacles before inlet and outlet?
• Is temperature set correctly?
• Are there some doors or windows left open?
• Is there any direct sunlight through the window during the cooling
operation?(Use curtain)
• Are there too much heat sources or too many people in the room during
cooling operation?
T1: Application temp. range of air conditioner -7°C~43C
T3: Application temp. range of air conditioner -7°C~52C
Lifespan of the Air condition is 7 years.
In Warranty period: Haier Electric Egypt LTD warrants to provide after sales
service as per warranty card;
Out of Warranty period (within lifespan): Haier Electric Egypt LTD
warrants to provide service at customer expense;
Out of the lifespan: The product still can be used, Haier Electric Egypt
LTD will provide service based on company’s service policy.
Cautions
The machine is adaptive in following situation
- Applicable ambient temperature range:
For: T1Cooling| Indoor| Maximum: D.B / W.B
Minimum: D.B / W.B| 32°C/23°C
21°C/15°C
---|---|---|---
Outdoor| Maximum: D.B
Minimum: D.B| 43°C/26°C
21°c
Heating| Indoor| Maximum: D.B
Minimum: D.B| 27°C
20°C
Outdoor| Maximum: D.B / W.B
Minimum: D.B / W.B| 24°C/18°C
-7°C/-8°C
For: T3
Cooling| Indoor| Maximum: D.B / W.B
Minimum: D.B / W.B| 32°C/23°C|
21°C/15°C
---|---|---|---
Outdoor| Maximum: D.B / W.B
Minimum: D.B| 52°C/31°C|
21°C
Heating| Indoor| Maximum: D.B
Minimum: D.B| 27°C
20°C
Outdoor| Maximum: D.B / W.B
Minimum: D.B / W.B| 24°C18°C
-7°C/-8°C
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F
3. If the fuse on PC board is broken please change it with a fuse type T. 3.15A/250V.
If the fuse of outdoor unit on PC board is broken, please change it with the
type of T. 25A/250V.
- The distance between the indoor unit and the floor should be more than 2m.
- The wiring method should be in line with the local wiring standard.
- After installation, the power plug should be easily reached..
- The used batteries should be disposed of properly.
- The appliance is not intended to use by young children or infirm persons without supervision.
- Young children should be supervised ensure that they do not play with the appliance.
- The appliance must be installed on a strong enough support.
- The wiring diagram is attached inside the machine.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>