QUANTOFIX MN91315 Ammonium Container with 100 Test Strips User Guide

June 12, 2024
QUANTOFIX

MN91315 Ammonium Container with 100 Test Strips
User Guide
QUANTOFIX MN91315 Ammonium Container with 100 Test
Strips

MN91315 Ammonium Container with 100 Test Strips

QUANTOFIX MN91315 Ammonium Container with 100 Test Strips - fig
1QUANTOFIX MN91315 Ammonium
Container with 100 Test Strips - fig 2

Pack content: **

**

1 aluminium container with 100 test strips
2 bottles NH4+-1
1 measuring vessel with 5 mL mark

Measuring range:

Visually 10­400 mg/L NH4+
Reflectometrically 10­350 mg/L NH4+
Color gradation:
0 · 10 · 25 · 50 · 100 · 200 · 400 mg/L NH4+

Safety precautions:

Reagent NH4+-1 contains sodium hydroxide solution 32 % CAS 131073-2. DANGER Causes severe skin burns and eye damage. Do not breathe vapors. Wear protective gloves/eye protection. IF SWALLOWED: rinse mouth. Do NOT induce vomiting. IF ON SKIN (or hair): Remove / Take off immediately all contaminated clothing. Rinse skin with water / shower. IF INHALED: Remove to fresh air and keep at rest in a position comfortable for breathing. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. For further information, please ask for safety data sheet (see www.mn-net.com/MSDS).

General indications:

Remove only as many test strips as are required. Close the container immediately after removing a strip. Do not touch the test field.

Additional indications:

The yellow colouration of the unused test fields is normal and does not indicate any decomposition of the reagents.

Instructions for use:

  1. Rinse the measuring vessel with the test solution and fill it to the 5 mL mark.
  2. Add 10 drops NH4+-1 (sodium hydroxide solution) to the sample.
  3. Shake carefully.
  4. Dip the test strip into the test solution for 5 s.
  5. . Shake off excess liquid.
  6. Compare with the color scale. If ammonium ions are present, the test field turns orange.

Interferences:

This test is intended for the detection of ammonium in surface and drinking water and in industrial waste water which do not contain high concentrations of interfering ions, such as water hardeners (calcium, magnesium), iron and sulfide ions. The determination of ammonium is not impaired by the following maximum foreign substance concentrations: 10.000 mg/L S2­, 1000 mg/L Cl­, Mg2+, SO42­, 100 mg/L Ca2+, 10 mg/L Fe2+

Disposal:

The used test strips must be collected for special hazard waste treatment.

Storage:

Avoid exposing the strips to sunlight and moisture. Keep container cool and dry (storage temperature 4­30 °C).
If correctly stored, the test strips may be used until the use-by-date printed on the packaging.

**** Item number
**** Warning
Permitted storage temperature range
**** Please read instructions for use
**** Batch identification
Use by
**** Store in a  dry place
Keep container closed
Contains suffi cient for tests

MACHEREY-NAGEL GmbH & Co. KG
Valencienner Str. 11 · 52355 Düren
Germany Tel.: +49 24 21 969-0
[email protected] 
www.mn-net.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

QUANTOFIX User Manuals

Related Manuals