The Personal Alarm Device, model #1329196/001, is part of a complete iWAREHOUSE Field Sense System. This device built by Frederick Energy Products provides warnings to both individuals and to vehicle operators to alert them that the individual has entered too close to an operating piece of equipment and is in a dangerous situation. The Personal Alarm Device is worn by the pedestrian to alert them of impending danger. It comprises two components: the base PAD module and a warning module permanently connected to the base module by an electrical cable.

Theory of Operation

Functions of the Personal Alarm Device are

  • To sense the 73 kHz field generated around a vehicle or piece of machinery equipped with a Magnetic Field Generator.
  • To echo a signal back to the Magnetic Field Generator to confirm signal recognition.
  • To transmit a 916.48 MHz RF signal to the Magnetic Field Generator.
  • Turn on its own alarm when the 73 kHz signal from the Magnetic Field Generator is confirmed

When a Personal Alarm Device (PAD) is in close proximity of the Magnetic Field Generator, the PAD will detect the 73 kHz magnetic field from the generator and analyze its field strength. When the 73 kHz field strength received by the PAD is above a certain threshold it will indicate that the distance of the Magnetic Field Generator is close enough to the PAD to signify a Warning or Danger condition. The PAD is calibrated to differentiate the magnetic field into two zones: Warning and Danger. The PAD will echo back to the Magnetic Field Generator with a 916.48 MHz transmission to confirm the signal recognition and then send the alert to the Magnetic Field Generator. The Magnetic Field Generator has its 916.48 MHz receiver ON when it is transmitting the 73 kHz field and is “listening” to receive any 916.48 MHz transmissions from a pedestrian with a PAD to indicate the individual is too close to the vehicle and warrants a warning or danger condition. When an alert condition has been confirmed between the PA  and Magnetic Field Generator, the PAD will activate its own alarm. The signal in the Warning Zone will activate an LED light a sounder as a continuing series of 3 rapid flashes/beeps followed by an OFF period every three seconds. If the pedestrian is in the Danger Zone, the alarm will change to a continuing pattern of alternating ON/OFF flashes/beeps (0.5 sec ON and 0.5 sec OFF).

Frequency of Operation

The Personal Alarm Device will receive on a frequency of 73 kHz and transmit on a frequency of 916.48 MHz.

FCC/IC Information

The FCC ID for the Personal Alarm Device is QUI-BC-PAD-2. This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received including interference that may cause undesired operation

Any intentional or unintentional changes or modifications to the configuration of the Personal Alarm Device, not expressly approved by Frederick Energy Products LLC, could void the user’s authority to operate the equipment.

Note : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is not guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

The required notices are specified in the RSS documents (including RSS-Gen) applicable to the equipment model. These notices are required to be shown in a conspicuous location in the user manual for the equipment, or to be displayed on the equipment model. If more than one notice is required, the equipment model(s) to which each notice pertains should be identified. Suppliers of radio apparatus shall provide notices and user information in both English and French

This device complies with Industry Canada license-exempt RSS-standards(s). Operation is subject to the following two conditions:

  1. this device may not cause interference, and
  2. this device must accept any interference, including interference that may cause undesired operation of the device.

Operation

Installation Information

The Personal Alarm Device (PAD) is a two-part device that includes a Warning Module permanently connected to a Base Module via a flexible electronic cable. The Warning Module has a metal clip that allows the user to clip the Warning Module to clothing or safety vest near the chest where the user can better hear the audible alert and see the LED light. The preferred way to wear a PAD is on a Safety Vest. THE PAD IS POWERED AT ALL TIMES EXCEPT WHEN ITS BATTERY IS BEING CHARGED.

Inoperability Warning

When a PAD battery voltage drops to approximately 3.5 Vdc or below while connected to a PAD, the PAD will signal a low battery condition. This alert is two rapid beeps of the sounder every 1.6 seconds. When the PAD determines the battery to have low voltage, the PAD will cease to give zone warnings and will give only a low battery alert. CAUTION: WHEN A LOW BATTERY IS SIGNALED, THAT PAD SHOULD NOT BE USED UNTIL ITS BATTERY IS RECHARGED.

Charging

The 3.7V Li-ion PAD battery is charged from a special charging cable provided with each PAD. The special charging cable has a USB male connector on one end and a plug on the other endthat magnetically attaches to the PAD. The charging cable provided with each PAD includes a 100-240 Vac Wall Charger. The Wall Adapter provides an output current of 0.1 A at a voltage of 5 Vdc. A LED light on the PAD displays a solid red light while the battery is charging and changes to solid green when the battery is fully charged. When the charging cable is disconnected, the sounder on the PAD will activate for approx. 2 seconds to indicate it is in proper working order.

The PAD should to be charged daily and connected to the charger over weekends and holidays.

Alerts

The Personal Alarm Device is to be worn on the chest of the pedestrian. The PAD has an LED visual indicator and an 80 dBA sounder to alert the user. If the battery voltage in the PAD drops to approximately 3.5 Vdc the PAD will signal a low battery condition with two rapid beeps every 1.6 seconds. NOTE: THE PAD WILL CEASE TO GIVE WARNINGS TO THE WEARER WHILE SENDING THE LOW BATTERY ALERT.

Maintenance

The Lithium Ion Battery in the Personal Alarm Device has a finite life and eventually will need replacement. Battery life is based on the number of times recharged. There are no published data about the exact number of charges the battery can undergo before its life is over, but literature suggests it’s at least 300 charges. Batteries in the PAD are designed to be replaced by the user. Only use an approved, protected Lithium Ion replacement battery. Contact FEP for the approved replacement battery list.

A daily check to verify the PAD is functioning visually and audibly is advised. Any PAD can be shown to be working properly by an approaching truck with a generator and verify that a warning is given at the expected distance

Adjustments

Factory settings of the Personal Alarm Device are expected to be stable and change very little with time. Adjustment capability of the PAD by the user is not available for field use.

Interferences

There are instances when the magnetic field generated from other sources such as an electrical panel, motorized machinery, large conductor cables etc. can generate intermittent alarm signals that are picked up by the Personal Alarm Device. The PAD is designed to be fairly sensitive to pick up the energy from the Magnetic Field Generator though it is also fairly selective. This sensitivity can cause the PAD to be triggered by some sources that are producing a strong magnetic frequency (that happen to fall within our guidelines) if the PAD is very close to the sources usually within a few inches.

If a user stands against a wall near a vehicle path, it is advisable that they do so with the PAD sticking furthest away from the wall as the wall may have interference sources such as high current cables or power panels etc. that may silence the PAD.

PAD Specifications

Part Number: 1329196/001
Size : 3.58” x 2.35” x 1.14” / 91mm x 60mm x 29mm
Weight : 7oz./ 198g
Input Voltage : 3.5 to 4.2 VDC
Magnetic Field Frequency : none
Receiver Frequency: 73 kHz signal
Transmitter Frequency: 916.48 MHz
Transmitter Power: 0.001W (typical)
PAD Battery: 3.7 VDC Lithium Ion
PAD Battery Capacity : 900 mAh
Charging Specifications : 0.75A at 5V max
Only use Lithium Ion Battery Charger
Operating Temperature Range: -30°C to + 70°C ; -22°F to 158°F
Environmental Considerations: 80 dBa minimum
Shipping Considerations: Contains a Lithium Ion Battery (packed in equipment)