TROTEC BZ15M Thermo Hygrometer User Manual

June 12, 2024
TROTEC

TROTEC BZ15M Thermo Hygrometer User Manual
TROTEC BZ15M Thermo Hygrometer

Notes regarding the instructions

Symbols

Warning
This signal word indicates a hazard with an average risk level which, if not avoided, can result in serious injury or death.

Caution
This signal word indicates a hazard with a low risk level which, if not avoided, can result in minor or moderate injury.

Note
This signal word indicates important information (e.g. material damage), but does not indicate hazards.

Note Icon  Info
Information marked with this symbol helps you to carry out your tasks quickly and safely.

Note Icon  Follow the manual
Information marked with this symbol indicates that the instructions must be observed.

You can download the current version of the instructions and the EU declaration of conformity via the following link:

QR Code

Safety

Read this manual carefully before starting or using the device. Always store the manual in the immediate vicinity of the device or its site of use.

Warning
Read all safety wamings and all instructions. Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury. Save all wamings and instructions for future reference.

  • Do not use the device in potentially explosive rooms or  areas and do not install it there.
  • Do not use the device in aggressive atmosphere.
  • Do notimmerse the device in water. Do not allow liquids to penetrate into the device.
  • The device may only be used in dry surroundings and must not be used in the rain or at a relative humidity exceeding the operating conditions.
  • Protect the device from permanent direct sunlight.
  • Do not expose the device to strong vibrations.
  • Do not remove any safety signs, stickers or labels from the device. Keep all safety signs, stickers and labels in legible condition.
  • Do not open the device.
  • Observe the storage and operating conditions (see Technical data).

Intended use
Only use the device for indoor temperature and humidity measurements within the measuring range specified in the technical data. Observe and comply with the technical data. To use the device for its intended use, only use accessories and spare parts which have been approved by Trotec.

Foreseeable misuse
Do not use the device in potentially explosive atmospheres, for measurements in liquids or at live parts. Trotec accepts no liability for damages resulting from improper use. In such a case, any warranty claims will be voided. Any unauthorised modifications, alterations or structural changes to the device are forbidden.

Personnel qualifications
People who use this device must:

  • have read and understood the instructions, especially the Safety chapter.
Residual risks

Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may use it as a dangerous toy.

  Warning
The device is not a toy and does not belong in the hands of children.

Warning
Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way! Observe the personnel qualifications!

Caution
Keep a sufficient distance from heat sources.

Note
To prevent damages to the device, do not expose it to extreme temperatures, extreme humidity or moisture.

Note
Do not use abrasive cleaners or solvents to clean the device.

Information about the device

Device description
The device BZ15M is a thermohygrometer for measuring the indoor humidity level and temperature.

An easy-to-read colour scale helps you to quickly determine whether the room needs to be aired out to reduce the humidity level.

Device depiction

Device Depiction

No. Designation
1 Humidity scale
2 Temperature scale

Technical data

Parameter Value
Model BZ15M
Relative humidity measuring range 0% to 100 % RH
Temperature meaning range
Accuracy Humidity: +3 % RH (20…100 %), +1 scale graduation Temperature: +2 °C
Operating and storage conditions -10to +50 °C with 0 to 100 % RH
Dimensions 0103 mm / height 24 mm
Weight 155g
Housing material Stainless steel

Transport and storage

Note
If you store or transport the device improperly, the device may be damaged.

Note
the information regarding transport and storage of the device.

Transport
The manufacturer packed the device to the best of his abilities to protect it against transport damage.

Storage
When the device is not being used, observe the following storage conditions:

  • dry and protected from frost and heat
  • protected from dust and direct sunlight
  • the storage temperature complies with the values specified in the Technical data

Operation

Before positioning the device, observe the following:

  • Do not expose it to direct sunlight.
  • Do not position it directly above a heater.
  • If possible, position it at an interior wall; avoid cooler exterior walls.
    Operating Instruction

Tips and notes on the humidity level in living spaces

General information:

Medical studies of recent years have demonstrated that an increased indoor humidity level of well above 50 to 60 % RH promotes asthma and allergies. A low relative humidity of 30 to 40 %, on the other hand, is harmless. Occasionally, the relative humidity level in flats with a good air exchange can even drop below 30 % during harsh winters without being detrimental to human health.

For the most part, it is the residents themselves who determine the humidity level in their living spaces during the heating period from October to April. A household of 3 to 4 persons emits about ten litres of water vapour into the room air every day, inter alia by taking showers, washing, cooking and breathing. As modern window seals are very tight to save energy costs and provide noise protection, this large amount of humidity must be released to the outside by airing several times a day.

The type of heating and ventilation determines the average relative humidity level in a flat during the winter. Since cold air always has a lower absolute moisture content than normal room air, the humid air can easily be exchanged by fresh, dry air in the winter by repeated brief and intensive airing throughout the day. Every living space that is not equipped with a ventilation system requires air changes several times a day, depending on the occupancy and moisture emission.

A limitation of the relative humidity to prevent too high humidity levels is only required during the heating period starting in autumn. It is recommended to maintain a temperature of approx. 20 °C in the entire flat. In winter:

In case of average outside temperatures below approx. +5 °C, sufficient air changes and a room temperature of approx. 20 °C, a relative humidity level between 40 and 50 % can easily be obtained. If it exceeds 50 %, the room should be ventilated.During frost periods, an indoor humidity level of less than 40 % RH is perfectly normal. The upper limit of 40 to 50 % RH (at approx. 20 °C) needs to be observed particularly in old buildings with little thermal insulation, as exceeding this value for a prolonged time increases the risk of mould formation. In autumn or spring:

At milder outside temperatures between 5 and 15 °C on average, the humidity level may reach 50 to 60 % RH. Please note:

Relatively speaking, warmer rooms are drier and colder rooms get more humid. This is why it is recommended to maintain a room temperature of at least 16 °C.

Correct airing:

If your window panes mist up frequently or mould starts to grow on walls, it is high time to review and, if necessary, break your old habits. The answers to the following questions can be useful:

  • How often should | air out?
    This question can be answered by taking a look at the hygrometer scale. Whenever the hygrometer and temperature pointers are outside the designated colour range, it is a good idea to air out the room.

  • For how long should | air out?
    This is also indicated on the hygrometer: During the winter, at temperatures below approx. +5 °C, a maximum of 5 minutes should be sufficient. If the outdoor air is warmer (5to 15 °C), about 10 to 15 minutes of airing are required.

  • How should | air out?
    An effective air exchange can only be obtained by leaving a window or window door in the room wide open. It is not  necessary to create a draught. Airing a room by tilting a  window or door over an extended period of time is generally insufficient and a waste of energy, especially considering that the affected room will cool down much more over time if the temperatures are low.

  • What should | do if | am not at home during the day?
    Airing your rooms sufficiently while you are at home will do. Ideally, this means airing out once every moming before you leave, once when you come home, and once before you go to bed. It is equally important not to switch off the heating completely during the day (16 to 18 °C).

  • Should | also ventilate in case of fog or rain?
    This is certainly recommendable. Even very moist, cold air always has a lower moisture content than normal indoor air. Besides, you also need a sufficient supply of fresh air when the weather is damp.

  • What do | have to note in the summer?
    Except for the basement, you can air out all rooms asneeded. There is no limitation on the hygrometer scale; the humidity level always corresponds to the outdoor climate. This is not harmful since the walls (except basement walls) are usually warm enough to prevent the temperature from falling below the dew point in normal living areas, and thus to avoid the formation of condensation e.g. on wall surfaces, which would promote mould growth.

  • How should | air out basement rooms?
    Basement rooms are at risk in the summer because during this season the warm outdoor air contains much moisture, which precipitates on cold surfaces.

  • Can | dry laundry in the flat?
    The ideal solution is a drying room that can be aired out permanently (even in the summer or in case of frost). Apart from that, laundry may only be dried in the flat if the room is closed and very well heated. The room should be aired out intensively several times during drying.

Information regarding the hygrometer

The measurement accuracy is +/- 3 % RH in the range from 20 to 100 % RH. The hygrometer’s measuring element is a specially pre-treated synthetic fibre which, unlike real hair, guarantees a high measurement accuracy without requiring maintenance.

Please note that the hygrometer must not be exposed to hot water or water vapour, otherwise the measurement accuracy can no longer be guaranteed. If deviations occur in comparative measurements carried out with a reference device, the hygrometer indication can be corrected, see chapter Maintenance and repair.

Reading the humidity level and temperature
After the device has been situated in the room for some hours, you can read the humidity level and temperature on the dial.

  1. Read the room temperature on the lower dial (2) and  match this temperature with the corresponding colour range:
    • Dark range for little heating: 16 to 18 °C
    • Medium range for normal heating: 18 to 22 °C
    • Bright range for intensive heating: 22 to 24 °C
  2. Now read the relative humidity level on the upper dial (1). Please note the different scales for winter %: (average temperatures below +5 °C) and autumn/spring & (average temperatures between 5 and 15 °C).
  3.  Compare whether the humidity value corresponds to the arget value depending on temperature and season.
    Device Depiction

Example:
At a room temperature of 20 °C in the winter, the relative humidity should not exceed 40 to 50 %, otherwise you may reduce the humidity level by airing.

Maintenance and repair

Adjusting the hygrometer
If the hygrometer displays a deviating humidity value e.g. during a reference measurement, the set screw at the side of the device can be used to adjust the indication.
Maintenance and Repair

In addition, the device should be moistened once a year. This is recommended in particular after longer periods with a low humidity level. To do so, wrap the entire device into a damp, warm cloth for approx. 30 minutes. It must then display 95 to 98 %. If the pointer is not within this range, the indication must be adjusted.

Cleaning
Clean the device with a soft, damp and lint-free cloth. Make sure that no moisture enters the housing. Do not use any sprays, solvents, alcohol-based cleaning agents or abrasive cleaners, but only clean water to moisten the clot

Repair
Do not modify the device or install any spare parts. For repairs or device testing, contact the manufacturer.

Disposal

The device does not contain any electrical or electronic elements. At the end of its life, please dispose of this device according to the valid legal requirements.

Trotec GmbH
Grebbener Str. 7 D-52525 Heinsberg ) +49 2452 962-400 .1+49 2452 962-200
[email protected]
www.trotec.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

TROTEC User Manuals

Related Manuals