The Volante v6C is a fragrance diffusion device from Viveur. It is the sixth- generation model and is designed to distribute fragrances into the atmosphere. The device utilizes purpose-built technology and features fragrances created by Master Perfumer Lorenzo Dante Ferro. The Volante v6C offers an exclusive sensory experience, creating a truly memorable environment.

Features:
Technical Specification:

  • Power Consumption: 5W at 12v, via 230v transformer provided
  • Weight: 800g including full fragrance cartridge
  • Colour: Matt Black
  • Protection Class: IP20
  • Control Method: Customized wireless mesh system, commissioned via app
  • External Wiring Connections: Airflow proof switch via 3.5mm jack plug, 12v power via 2.1mm barrel jack
  • Mounting arrangements: Device is provided with rubber feet on base, or brackets with screw slots for wall-mounting

Usage Instructions

  1. Choose a suitable location for the Volante v6C device. Ensure there is at least 200mm of space above the device for cartridge removal.
  2. If wall-mounting, use the provided brackets with screw slots. If not, place the device on a flat surface using the rubber feet on the base.
  3. Connect the device to power by plugging the 230v transformer into a power outlet and connecting the 2.1mm barrel jack to the device.
  4. Commission the device using the customized wireless mesh system and the accompanying app. Follow the app instructions for setup and control.
  5. If desired, interface the device with DMX and other systems for additional control options.
  6. To connect the device to the airflow duct, use the provided airflow proof switch via the 3.5mm jack plug.
  7. For any sharp bends in the installation, use the RA Bend Duct Insertion Plate provided. Minimize the use of this plate in favor of the hose.
  8. Use the nylon hose provided to distribute fragrances into associated ventilation systems. Connect the hose to the Volante Cartridge Connection and other necessary connectors, such as the straight connector for extension hoses or the pitot tube connector.
  9. Refer to HVAC drawings and consult with Viveur for the best location of the Volante devices and duct access plates.

Please note that Viveur Ltd reserves the right to change the information contained in this datasheet without notice. Users should carefully follow the instructions provided and Viveur Ltd will not accept liability for damages caused by errors or omissions in the information.

Description

Volante v6C is the sixth-generation fragrance diffusion device from Viveur.
Utilising our purpose-built technology, we distribute the fragrances from Master Perfumer Lorenzo Dante Ferro into the atmosphere.
Volante V6C offers an exclusive sensory experience, making your environment truly memorable.

Features

  • Variable speed distribution pumps offer accurate control of fragrance intensity
  • Air pressure diffusion technology preserves the integrity of the fragrance
  • Built to be concealed in plant spaces, to avoid any aesthetic impact on interiors
  • Powerful distribution allows long distances between equipment and interiors
  • Wireless mesh control technology for easy setup, autonomous operation, zero control cabling requirements, and flexible grouping for large spaces.
  • Easy to retrofit in existing interiors
  • Easy-change removable cartridge system, reducing maintenance time

Technical Specification

  • PowerConsumption
    5W at 12v, via 230v transformer provided

  • Weight
    800g including full fragrance cartridge

  • Colour
    Matt Black

  • Protection Class
    IP20

  • Control Method
    Customised wireless mesh system, commissioned via app. Sensors, automation and timing devices available via commissioning. Interface with DMX and other systems available.

  • External WiringConnections
    Airflow proof switch via. 3.5mm jack plug, 12v power via 2.1mmbarrel jack

  • Mounting arrangements
    Device is provided with rubber feet on base, or brackets with screw slots for wall-mounting

Installation Kit – Air Side Components

Volante v6C uses pneumatic hoses and associated push fittings according to BS5409 to distribute fragrances into associated ventilation systems.
Each machine is provided with an appropriate selection of parts for the application.

Components

Volante Cartridge Connection

Viveur-Volante-v6C-Fragrance-Diffusion-Device-3

Connector provided as standard with all Volante fragrance cartridges.

  • Type: Push Fit
  • Diameter: 10mm
  • Temperature Range: 0°C to +60°C
  • Pressure: 0-10 bar

Nylon Hose

Kit of parts provided for installation with each machine includes a hose.

  • Outside Diameter: 10mm
  • Inside Diameter: 8mm
  • Bend radius: 100mm
  • Temperature Range: -20°C to +70°C
  • Rated Pressure: 250psi

RA Bend

Viveur-Volante-v6C-Fragrance-Diffusion-Device-4

Connector provided for any sharp bends, that cannot be achieved with the hose bend radius. Minimise in favour of hose.

  • Type: Push Fit
  • Diameter: 10mm
  • Temperature Range: 0°C to +60°C
  • Pressure: 0-10 bar

Straight Connector

Viveur-Volante-v6C-Fragrance-Diffusion-Device-7

Connector provided for extension hoses, or to connect to the pitot tube.

  • Type: Push Fit
  • Diameter: 10mm
  • Temperature Range: 0°C to +60°C
  • Pressure: 0-10 bar

Duct Insertion Plate

Connector provided for connection to the airflow duct.

  • Type: Screw Fit
  • Duct Access Hole Diameter: 7mm

Viveur-Volante-v6C-Fragrance-Diffusion-Device-7

Other connection parts also available if required, such as bulkhead fittings, manifolds, Y-connectors etc.
Viveur will advise best location of Volante devices and duct access plates, based on finalised HVAC drawings and site visits as necessary.

Installation Kit – Electrical

Volante v6C uses pre-prepared cables for the power supply and airflow proof connections to the device.

Components
Airflow Proof Switch

Airflow pressure switch, provided with prewired cable and 3.5mm jack to connect to Volante.

  • Detection Range: 20-200Pa
  • Pressure Connections: c/w 6mm ID push-on tubing
  • Protection: IP54

Power Supply

AC-DC Power Supply with international plug connectors

  • Input Power: 100-240v AC, 47-63Hz
  • Output Power: 12-15v 6W

Control Interface Options Volt-Free Contact

Powered switch interface with up to 8 inputs, allowing usage of any volt-free control interface to trigger presets. Battery version also available.

  • Power Supply: 100-240v AC, 0.6 Watt
  • Protection Class: IP64
  • Dimensions: 44 x 44 x 23mm

DMX

DMX input device, drive with any DMX master to control Volante presets. 4 channels of DMX available, DMX start address user-defined.

  • Power Supply: 12-24v DC, 0.3A
  • DMX Input: 3-wire non-isolated DMX
  • Dimensions: 72 x 30 x 18mm

Ethernet

POE Gateway interface enables Ethernet-based integration into a cross-system building management system –including a variety of innovation options.

  • Power Supply: Power over
  • Ethernet Protection Class: IP20
  • Dimensions: 121 x 62 x 31 mm

Wall Controller

Native wireless controller with wide range of customer finishes for luxury applications.

Engraving available

  • Type: Battery powered
  • Dimensions: 84 x 84mm

Mounting Guidance

Wall Fixing – Screw Mount Locations

Floor Mounting – Rubber Feet

Where several Volante devices are mounted side by side on the same wall, we would advise that free wall space totaling 200mm wide by 450mm high is allowed per device.
For example, 6 devices in a 3 x 2 configuration would require space of 600mm wide by 900mm high, as per below sketch.

Viveur-Volante-v6C-Fragrance-Diffusion-Device-10

Hose runs may be mounted on cable tray, basket, cable tie bases or similar.
Fixings should be every 500mm, and either side of every change of hose direction.
Maximum bend radius is 100mm, if a tighter bend is needed a right angle connector should be used.

Viveur Ltd
137 Blenheim Road Harrow
HA2 7AA

Viveur Ltd reserves the right to change the information contained in this datasheet as and when required without notice. Users must take care to use the information contained in this leaflet. Viveur Ltd will not accept the liability for damages, loss and expenses that may be caused by omissions and errors in the information provided