AirDance OL12-D001GA Pints 100 Sq. Ft. Dehumidifier Instruction Manual

June 12, 2024
AirDance

AirDance OL12-D001GA Pints 100 Sq. Ft. Dehumidifier

AirDance-OL12-D001GA-Pints-100-Sq.-Ft.-Dehumidifier-
PRO

CAUTIONS

  • Please read all instructions carefully.
  • Retain instructions for future reference.
  • Separate and count all parts and hardware.
  • Read through each step carefully and follow the proper order.
  • We recommend that, where possible, all items are assembled near to the area in which they will be placed in use, to avoid moving the product unnecessarily once assembled.
  • Always place the product on a flat, steady and stable surface.
  • Keep all small parts and packaging materials for this product away from babies and children as they potentially pose a serious choking hazard.

Please keep this manual carefully for further reference!
Thank you for selecting our dehumidifier. Be sure to read this manual carefully before using it. Any questions, please contact our customer for help.

BEFORE YOU BEGIN
Please read the operating instructions carefully before using your dehumidifier for the first time.

PRODUCT DESCRIPTION
The dehumidifier is used to remove excess moisture from the air. The resulting reduction in relative humidity protects buildings and their contents from the adverse effects of excess humidity.

FOR YOUR SAFETY
Your safety is the most important thing we are concerned! Please read this manual carefully and fully understand it before operating your dehumidifier.

OPERATIONAL PRECAUTIONS
WARNING- To reduce the risk of fire, electric shock or injury to persons or property:

  • If the supply cord is damaged, it must be replaced by the manufacturer, in order to avoid a hazard.
  • The appliance shall be disconnected from its power source during maintenance.
  • Always operate the unit from a power source of equal voltage, frequency and rating as indicated on the product identification plate.
  • Always use a power outlet that is grounded.
  • Unplug the power cord when cleaning or when not in use.
  • Do not operate with wet hands. Prevent water from spilling onto the unit.
  • Do not immerse or expose the unit to rain, moisture or any other liquid.
  • Do not leave the unit running unattended.
  • Do not tilt or turn over the unit.
  • Do not unplug while the unit is operating.
  • Do not unplug by pulling on the power cord.
  • Do not use an extension cord or an adapter plug.
  • Do not put objects on the unit.
  • Do not climb or sit on the unit.
  • Do not insert fingers or other objects into the air outlet.
  • Do not touch the air inlet or the aluminum fins of the unit.
  • Do not operate the unit if it is dropped, damaged or showing signs of product malfunction.
  • Do not clean the appliance with any chemicals.
  • Ensure the unit is far away from fire, inflammable, or explosive objects.
  • The unit shall be installed in accordance with national wiring regulations.
  •  Do not use means to accelerate the defrosting process or to clean, other than those recommended bythe manufacturer.
  • The appliance shall be stored in a room without continuously operation sources(for example: open flames, an operating gas appliance or an operating electric heater).
  • The appliance shall be stored so as to prevent mechanical damage from occurring.
  • Do not piece or burn, even after use.
  • Be aware that refrigerants may not contain an odour.
  • Pipe work shall be protected from physical damage and shall not be installed in an unventilated space, If that space is smaller than 43 sq.ft.
  • Compliance with national gas regulations shall be observed.
  • Keep any required ventilation openings clear of obstruction.
  • The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation. Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with industry, recognized assessment specification.

PARAMETERA

AirDance-OL12-D001GA-Pints-100-Sq.-Ft \(1\)

FEATURE

  • Powerful moisture removal (up to 30Pints/day dehumidification)
  • Humidity Monitor shows current air humidity
  • Auto mode automatically adjusts humidity levels
  • A 24-hour timer to set the time of operation
  • Effectively removes moisture, dust from the air
  • Low power consumption-energy efficient
  • Quiet fan has two speed settings
  • Auto-Defrost at low temperature
  • Auto shut-off/ auto restart
  • Electronic control Laundry drying function
  • Continuous drainage or 6Boz.water tank

PRODUCT DESCRIPTION

AirDance-OL12-D001GA-Pints-100-Sq.-Ft \(2\) AirDance-OL12-D001GA-Pints-100-Sq.-Ft \(3\)

OPERATIONS

AirDance-OL12-D001GA-Pints-100-Sq.-Ft \(4\)

  • Power On/Off
    When the power is off, press the power button once to turn the dehurnidifer on. Atthis tirne, the power indicator will light up and the fan will run at high speed by default, and the dehurnidifier will begin running at the default target humidity of 60%. When the power is on, press the power button once to turn the dehurnidifer off, the light goes off and the compressor stops functioning irnrnediately, the fan turns off after a 7 Os delay.

  • Humidity Change
    Touch the humidity button to view the current ambient humidity. Touch again to set the target humidity. Each time you press this button, a beep will sound off, the screen flashes once, then the target humidity increases by 5% at a tirne. The range of target humidity is 20%-25%-30%-35%-40%-45%-50%-55%- 60%-65%-70%-75%-80%-85%-90%-95%. After 3 seconds, the system will confirm the input value and exit the humidity-setting mode, displaying the current humidity value. *Under the clothes-drying mode: the target humidity remains unchanged. Press and hold the humidity button for 5s to display the current arnbient ternperature.

  • Timer
    Press this button to activate the tirner that spans frorn 0-24 hours. Each tirne you press the button, the timer increases by 1 hour and the corresponding time is displayed on the screen. If the value is “00” , the timer is cancelled, and the indicator goes out. When the dehumidifier is running, activate the tirner to turn off the machine. When the dehumidifier is in the standby state, activate the timer to turn on the dehumidifier. Once the timer is set, the indicator light for the timer will stay on. Once the tirne runs out, the indicator lightturns off automatically.

  • Sleeping Mode
    Press this button to activate the sleeping mode: all indicator lights dim down, and the fan speed will be changed to low. When the sleeping mode is on, press the button again to turn it off.

  • Mode Selection
    Press this button to switch between three dehumidification modes: intelligent, sleeping and clothes-drying, and the corresponding indicator light for each mode will be on.

    • Intelligent mode: The default target humidity is 60% and the target temperature is adjustable.
    • Rainy day mode: The default target humidity is 40% and the target temperature is adjustable.
    • Clothe-drying mode: The dehumidifier runs continuously and the target humidity is non-adjustable.
  • Wind Speed/Child Lock

    • Press this button once to switch between high and low wind speed.
    • Press and hold this button for 3 seconds to enable/disable the child lock function.

INDICATOR LIGHTS

Power Indicator
The power indicator will only be on when the dehumidifier is powered on, and it will display different colors according to the ambient humidity as well as the current mode:

  • Ambient humidity<60%: the indicator turns blue (always on).
  • 60% ,;ambient humidity<80%: the indicator turns green (always on).
  • Ambient humidity 80%: the indicator turns red (always on).
  • When the error codes E2, CL, CH, LO and HI appear, the indicator turns red (always on).
  • When the tank is full, the indicator turns red (flashing).
  • When the dehumidifier is defrosting, the indicator turns blue (flashing).

Water Full Indicator
When the tank is full, the indicator will turn red, and the compressor and fan will stop running. At the same time, the buzzer will beep to remind the user to empty the tank and place the water tank in the right position.

Mode Selection Indicator

  • Under the intelligent mode, the corresponding indicator will be on.
  • Under the sleeping rnode, the corresponding indicator will be on.
  • Under the clothe-drying mode, the drying mode indicator will be on.

Speed/Child Lock Indicator

  • When the fan speed is low, the corresponding indicator will be on.
  • When the fan speed is high, the corresponding indicator will be on.
  • When the child lock function is enabled, the corresponding indicator will be on.

Water-full indicator
When the water tank is full, the water-full indicator turns red, and the buzzer beeps as a rerninder to empty the tank. Atthis time, the dehumidifier will temporarily stop working until the tank is emptied.

Disabling the water-full Alarm
When the water tank is full and the dehumidifier starts beeping, you can press any button to cancel the alarm, but the water-full status remains.

Emptying the Tank

  1. Grasp the handle at the bottom of the tank and pull the tank out of the body.
  2. Emptythe tank.AirDance-OL12-D001GA-Pints-100-Sq.-Ft \(21\)

MAINTENANCE

Notice: In order to avoid electric shocks, please power the dehumidifier off and unplug it before cleaning. Clean the air filter (every 2 weeks):
Dust collects on the air filter to restrict airflow. Limited airflow will reduce the efficiency of the dehumidifier. If the airflow is blocked, damage may be caused to the dehumidifier. Air filter needs to be cleaned regularly. Air filters are detachable for easy cleaning. It is forbidden to operate the dehumidifier without an air filter, otherwise the evaporator may be polluted.

  1. Take out the air filter.AirDance-OL12-D001GA-Pints-100-Sq.-Ft \(22\)
  2. Gently brush the dust off the air filter using the brush of the vacuum cleaner. Gently suck the dust off the surface using a vacuum cleaner. In case of a very dirty filter, wash it with clean water and soft detergent, then dry it thoroughly.AirDance-OL12-D001GA-Pints-100-Sq.-Ft \(23\)
  3. Install the air filter.

Storage
When not using the product for a long time and intend to store it, please pay attention to the following steps:

  1. Empty the water in the water tank and wipe the water droplets on bottom of inside machine.
  2. collect the power cord and store it in a dry water tank.
  3. Clean the filter.
  4. Place the machine in a cool, dry environment.

Spacing
When the dehumidifier is in operation, make sure that the rear of the dehumidifier has a minimum spacing of 20 cm as shown in the following figure:

AirDance-OL12-D001GA-Pints-100-Sq.-Ft \(25\)

Trouble Shooting

  1. Compressor running and stop conditions
    When the ambient temperature <5°C, or Ambient temperature> 38°C, or the humidity sensor fails, the compressor does not work: When 5°C< Ambient temperature< l 6°C, the compressor automatically defrosts at intervals; during the defrosting, the compressor does not work, The fan still works.

  2. BEFORE CALLING FOR SERVICE
    Before contacting professional service, review the troubleshooting list that includes common occurrences that are not the result of a defect in workmanship or materials.

AirDance-OL12-D001GA-Pints-100-Sq.-Ft \(26\)

Storage and disposal

  1. Store
    Long-term storage – If you are not going to use the appliance for an extended period of time (more than a few weeks), it is the best to clean and dry it completely.
    Follow these steps to store the device:

    • Take the instrument out
    • Clean the water tank off materials and dry it with a towel
    • Wash the filter and let it dry completely in a shaded area
    • Collect the power cord in the tank
    • Re-install the filter at its position
    • Preserving the appliance in a ventilating, dry, corrosive gas-free, and safe indoor space
    • The appliance must be kept in an upright position when in storage.|
      Note that in order to avoid the damage of parts and mold, the carburetor in the device must be dried. Take the instrument out and leave it in a ventilated place for a few days to dry. Another method is to adjust the moisture level to 5 percent higher than the ambient moisture level, so that a fan can blow to dry the evaporator for several hours.
  2. disposal
    Note: If anything happens, turn off the power and turn on the grid immediately. Then call a qualified electrician Don’t treat electronic devices as garbage, but use them separately. Please contact the authorities for information on the existing collection system.

Please read this manual before operating and save it for future reference. You are covered with 1-year free warranty offered by AirDance that is automatically valid from the date of purchase. To extend the warranty or express any questions or concerns, please emailAirDance at support@airdance.us

Read User Manual Online (PDF format)