BTU 50000 43 Inch Fire Pit Table Instruction Manual

October 30, 2023
BTU

BTU 50000 43 Inch Fire Pit Table

BTU-50000-43-Inch-Fire-Pit-Table-PRODUCT-IMG

Attention

  1. We are concerned about each customer’s experience, if there is any missing or damage, please contact us at any time, and we will provide effective solutions. We also have the assembled video on the product details page to help you install this fire pit table.
  2. Come with multiple boxes, please check if you already received all boxes we shipped to you. Sometimes these boxes will not arrive on the same date, hope you can wait for 2-3 more days or contact us for more help. If you already have all boxes, please kindly send us messages to let us know the name of the missing part regarding the first page of the instructions. We will send a replacement to you asap.
  3. If there is any damage, please send clear photos of the damaged part to us as an attachment, we will check and offer you the best solution soon.
  4. This fire pit table needs a 1 AAA 1.5V battery to ignite. (Note: The battery is Not included.)

ASSEMBLY INSTRUCTIONS

DANGER

  • FIRE OR EXPLOSION HAZARD
  • If you smell gas:
  • Shut off the gas to the appliance.
  • Extinguish any open flame.
  • If the odor continues, leave the area immediately.
  • After leaving the area, call your gas supplier or fire department.
  • Failure to follow these instructions could result in fire or explosion, which could cause property damage, personal injury, or death.

WARNING

  • Do not store or use gasoline, or other flammable vapors and liquids, in the vicinity of this or any other appliance.
  • An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.

WARNING: For Outdoor Use Only. Installation and service must be performed by a qualified installer, service agency, or gas supplier.

DANGER

CARBON MONOXIDE HAZARD
This appliance can produce carbon monoxide which has no odor. Using it in an enclosed space can kill you. Never use this appliance in an enclosed space such as a camper, tent, car, or home.

  • INSTALLER: Leave this guide with the appliance.
  • CONSUMER: Retain this manual for future reference.

WARNING
If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.

warning
Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.

BTU-50000-43-Inch-Fire-Pit-Table-FIG-2

LP SAFETY

  • Do not store a spare LP gas cylinder under or near this appliance.
  • Never fill the cylinder beyond 80 percent full.
  • If the information in “(a)” and “(b)” is not followed exactly, a fire causing death or serious injury may occur.

MINIMUM CLEARANCES

  • Bottom: Non-Combustible Surface
  • Top: 60 inches
  • Sides: 36 inches
  • For Installation on (or over) non-combustible floors only

Do not use this appliance under overhead combustible surfaces.

  • Max. Input: 50,000 BTU/h
  • Max. Gas Supply Pressure: 250 PSI
  • Min. Gas Supply Pressure: 25 PSI

This appliance shall be used only outdoors in a well-ventilated space and shall not be used in a building, garage or any other enclosed area. If this appliance is not in use, the gas must be turned off at the supply cylinder. Indoor storage of this appliance is permissible only if the cylinder is disconnected and removed from the appliance. Cylinders must be stored outdoors in a well-ventilated area out of the reach of children. Disconnected cylinders must have threaded valve plugs tightly installed and must not be stored in a building, garage or any other enclosed area. The gas pressure regulator provided with this appliance must be used, and must be the same model as that supplied with the unit. The cylinder supply system must be arranged for vapor withdrawal. Cylinders used with this unit must have a collar to protect the cylinder valve. An approved LP-Cylinder stabilizer, such as the stabilizer ring included, must be used when the appliance is in use.

LP CYLINDER

All LP cylinders to be used with this appliance must be:

  • Constructed and marked in accordance with the specifications for LP-gas cylinders Standard, CAN/CSA B339, Cylinders, Spheres, and Tubes for the Transportation of Dangerous Goods.
  • Provided with a listed overfilling prevention device.
  • Provided with a cylinder connection device compatible with the connection for outdoor cooking appliances.
  • Only a 20 lb (9 kg) LP gas cylinder is to be used for this appliance, approximately 18″ (46 cm) high & 12″ (30 cm) diameter.

WARNING

  • Please ensure that all adults and children who use or are near a unit in use are aware of the hazard of high surface temperatures present on the unit during use and should use caution and stay away to avoid burns or clothing ignition.
  • Carefully supervise young children in the area of this appliance.
  • Clothing or other flammable materials should not be hung from the appliance or placed on or near the appliance. Any guard or other protective device removed for servicing the appliance must be replaced prior to operating the appliance.
  • Installation and repair should be done by a qualified service person.
  • The appliance should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required as necessary. It is imperative that control compartment, burners, and circulating air passageways of the appliance be kept clean.

ENCLOSURES FOR SELF-CONTAINED LP GAS SYSTEMS

An enclosure for an LP-gas cylinder shall be ventilated by openings at both the upper and lower levels of the enclosure. This shall be accompanied by one of the following:

  • One side of the enclosure shall be completely open; or
  • For an enclosure having four sides, a top, and a bottom:

At least two ventilation openings shall be provided in the sidewalls of the enclosure, located within 5 in (217 mm) of the top of the enclosure, equally sized, spaced at a minimum of 90 degrees (1.57 rad), and unobstructed. The opening(s) shall have a total free area of not less than 1 in2 per lb (14.2 cm2 per kg) of stored fuel capacity. Ventilation opening(s) shall be provided at the floor level of the enclosure and shall have a total free area of not less than 1/2 in2 per lb (7.1 cm2 per kg) of stored fuel capacity. If ventilation openings at the floor level area are in the side wall, there shall be at least two openings. The bottom of the openings shall be 1 in (25.4 mm) or less from the floor level and the upper edge no more than 5 in (127 mm) above the floor level. The openings shall be equally sized, spaced at a minimum of 90 degrees (1.57 rad), and unobstructed. Every opening shall have minimum dimensions so as to permit the entrance of a 1/8 in (3.2 mm) diameter rod. Ventilation openings in sidewalls shall not communicate directly with other enclosures of the appliance.

CONNECTION

  1. Be sure the cylinder valve and appliance valves are “off”.
  2. Place full LP gas cylinder on tank stabilizer ring. Secure the base of the LP gas cylinder by hand tightening the wing-nut collar.
  3. Center the nipple in the cylinder valve and hold it in place.
  4. Using the other hand, turn the hand wheel clockwise until there is a positive stop. Do not use tools.
  5. Hand tightens only. When making the connection, hold the regulator in a straight line with the cylinder valve, so as not to cross-thread the connection.
  6. Leak test the connection.

DISCONNECTION

  1. Be sure the cylinder valve and appliance valves are “off’ before disconnection.
  2. Using one hand, turn the hand wheel anticlockwise.

LEAK TEST

  1. DO NOT USE OR PERMIT SOURCES OF IGNITION IN THE AREA WHILE DOING THE LEAK TEST. THIS INCLUDES SMOKING.
  2. Leak testing should be done once per year or whenever the LP gas cylinder or any other gas system part is taken apart, serviced or replaced, whichever is more frequent.
  3. Ensure all gas system coupling joints are tight and properly attached.
  4. Prepare a leak-testing solution of half liquid detergent and half water.
  5. Apply the solution to the LP gas delivery system at points as shown in the illustration indicated on page 5.
  6. The leak(s) must be stopped by tightening the loose joints, if possible, or by replacing the faulty parts(s) with the part(s) recommended by the appliance manufacturer.