STARMATRIX Clever-Pool Pump Inverter Instruction Manual

June 11, 2024
STARMATRIX

STARMATRIX Clever-Pool Pump Inverter

STARMATRIX-Clever-Pool-Pump-Inverter-PRODUCT

Product Information

Clever-Pool Energy Saver
The Clever-Pool Energy Saver is a highly precise electronic device designed by STARMATRIX GROUP INC. It is compliant with the EN61800-5-1:2007 safety standard and is intended for use in swimming pool maintenance. The device uses vector frequency technology to save energy and ensure efficient pool operation. It is suitable for both indoor and outdoor use and has an IP65 rating. It should be installed in an environment with an ambient temperature of -10°C to +40°C, away from direct sunlight, corrosive fluids, radioactive or flammable substances, dust, and metal scraps.

Product Usage Instructions

  1. Before installation, read the instruction manual carefully and follow all safety and caution guidelines.
  2. Check the product for any damage caused during transportation before connecting it to the power supply.
  3. Ensure that the correct power supply is used and that the control panel is closed before connecting the power to avoid electric shock or explosion
  4. Do not confuse the input and output terminals.
  5. If the Clever-Pool has been in stock for over 2 years, use a voltage adjuster to increase the voltage gradually when connecting the power.
  6. Do not touch the wire terminals when power is connected to avoid electric shock.
  7. Wait for at least 10 minutes after cutting off the power when all indication lights are off before performing maintenance.
  8. Do not use wet hands for operation.
  9. If you need to change any parts, ask for professional help and do not leave any metal objects inside the Clever-Pool.

Note: Only professionals should perform installation and maintenance. Do not touch the terminals or CMOS elements, disconnect the wire connection when power is connected, or perform a voltage duration test on the Clever-Pool.

Installation, Operation & Maintanence Instructions

Please leave this instruction booklet with the owner as it contains important maintanence and safty information. Read this manual carefully before commencing installation

SAFTY AND CAUTION

READING BEFORE INSTALLATION
Clever-Pool uses vector frequency technology and is a highly precious electronic device, to ensure for personal and property safty, please read carefully this instruction before using.
There are marks【DANGER】or【CAUTION】in this book,please strictly obey when moving,installing,using or checking the product.

DANGER

  1. Please make sure to use the correct power supply.
  2. Please make sure to close the control panel before power connection to avoid eletricity shock or explosion
  3. Please make sure not to confuse the input and output terminals.
  4. If our Clever-Pool is stocked over 2 years, please use a voltage adjuster to increase the voltage gradually when power connection.
  5. Please DO NOT touch the wire terminals when power is connected.
  6. Please wait after 10 minutes after the power is cut off when all the indication lights are off for further maintanence.
  7. Please DO NOT use wet hands for operation.
  8. Please ask for professional help if you need to change any parts, strictly forbidden to leave any metal things inside our Clever-Pool.

CAUTION

  1. Installation based on local safty rules.
  2. Only professionals for installation and maintanence.
  3. Power connection is required after control panel closed,electricity shock will occure if against this rule.
  4. Do not touch the terminals,electricity shock will occure if against this rule.
  5. Do not disconnect the wire connection if power is connected, serious personal damage will occure if against this rule.
  6. Do not touch CMOS elements.
  7. No voltage duration test allowed for our Clever-Pool, it will get semiconductor elements damaged.
  8. Make sure air ventilation when in summer or high ambient temperature use,this will avoid condensate water formed and electrical faulty.
  9. Please stock our Clever-Pool in a dry,ventilated and cool place.

PRODUCT CHECK BEFORE INSTALLATION

Each Clever-Pool is 100% tested before factory delivery, you need to check by yourself below:

  1. If our Clever-Pool is the right model you ordered.
  2. Any damage caused by transportation, if yes please do not connect to power supply.

ENVIROMENT CAUTION

The correct enviroment for our Clever-Pool determines its right function and life. So the installation must obey below:

  • IP65 for both outdoor and Indoor use
  • No direct sunshine
  • No corrosive fluid
  • Away from radioactive or flammable substances
  • Ambient temperature:-10℃~+40℃
  • No oil or salt
  • No dust or metal scraps
  • No electromagnetic interference

DIMENSION AND PARAMETERS

DIMENSION AND TECHNICAL PARAMETERS

PARAMETER SHEET

Model

Item

| Clever-

Pool/220V

| Clever-Pool

M/220V

| Clever-Pool/380V
Input power| Single-phase AC| Single-phase AC| Three-phase AC
Input voltage| 220V±15%| 220V±15%| 380V±15%
Input frequency| 50/60Hz| 50/60Hz| 50/60Hz
Output voltage| 1~220V| 3~220V| 3~380V
PUMP TYPE| SINGLE-PHASE| THREE-PHASE| THREE-PHASE
Max.Power| MAX 2HP| MAX 3HP| MAX 5HP
Max current| 12A| 10A| 10A
Mode option| Manual or Auto
Cooling| By air


Motor speed range

| 50Hz:1200~3000rpm
60Hz:1200~3600rpm

Dimension

INSTALLATION AND FUNCTION EXPLANATION

INSTALLATION SKETCH AND DESCRIPTION

Procedure and instruction

  1. Use a cross screwdriver to take off the screws as shown 3 and plate 1
  2. Put plate 1 in your installation place and use screws as shown 2 to fix plate 1.
  3. Put the control box 4 on plate 1 and fix with screws as shown 3
  4. Connect the plug from pump to the part as shown 6.
  5. Connect plug 5 as shown to the correct power supply socket.
  6. Strictly follow the operation steps as indicated in this manual.

WIRE CONNECTION

  • Wires has been preconnected before factory delivery as per request, if you need to re-connect the wires, please pay attention as below:
  • WIRE CONNECTION AND DESCRIPTION FOR 2HP AC220V SINGLE PHASE IN – SINGLE PHASE OUT

WIRE CONNECTION SKETCH

Procedure and instruction

  1. Disconnect power before opening the control panel.
  2. Make sure no connection between PE,N,L1 termials and U,V terminals.
  3. Wire connection operated only when power disconnected.
  4. Check if the input voltage from the power supply is compliance with clever-pool.
  5. No voltage duration test
  6. Screw torque for terminal screws more than 1.7N.m
  7. Ground link must be connected before operation.
  8. Must use the copper wires over 3G1.5mm2
  9. Power supply connected only after the control panel is fixed,

WIRE CONNECTION AND DESCRIPTION FOR 3HP AC220V SINGLE PHASE IN – THREE PHASE OUT

WIRE CONNECTION SKETCH

Procedure and instruction

  1. Disconnect power before opening the control panel.
  2. Make sure no connection between PE,N,L1 termials and U,V,W terminals.
  3. Wire connection operated only when power disconnected.
  4. Check if the input voltage from the power supply is compliance with clever-pool.
  5. No voltage duration test
  6. Screw torque for terminal screws more than 1.7N.m
  7. Ground link must be connected before operation.
  8. Must use the copper wires over 3G2.0mm2
  9. Power supply connected only after the control panel is fixed,

WIRE CONNECTION AND DESCRIPTION FOR 5HP AC380V THREE PHASE IN – THREE PHASE OUT

WIRE CONNECTION SKETCH

Procedure and instruction

  1. Disconnect power before opening the control panel.
  2. Make sure no connection between PE,T,S,R termials and U,V W terminals.
  3. Wire connection operated only when power disconnected.
  4. Check if the input voltage from the power supply is compliance with clever-pool.
  5. No voltage duration test
  6. Screw torque for terminal screws more than 1.7N.m
  7. Ground link must be connected before operation.
  8. Must use the copper wires over 4G2.0mm2
  9. Power supply connected only after the control panel is fixed,

RUNNING AND OPERATION

BEFORE RUNNING AND OPERATION

  1. Check if installation and wire connection is 100% correct.
  2. Check if any metal substances left in the product.
  3. Check if wire terminals are well tightened.
  4. Check if there are naked wires on the terminals touching other terminals.
  5. Check if the contral panel is well closed.
  6. A GFCI device must be used in the system.
  7. Check if the power supply frequence is the same as CLEVER-POOL.
  8. If all connection is correct,run with no load. If it is a three-phase pump. Please check the motor rotation direction, you can choose the wire connection between UV,WV or WU.

PROGRAMMING GUIDE

  1. The Clever-Pool has two running modes:Manual mode and Auto mode.

    • Manual mode is used when you are connecting to a pool chlorinator or timer. The system time settings are not required to run in this mode.

    • Auto mode is used when there is no chlorinator or timer and includes up to 4 separate timers with individual speed
      options.This is ideal for when you want to run your pool pump at different times and speeds to take advantage of the different electrical consumption.

    • In stop and manual mode press the SET/RESET button once to switch to Auto Mode. In stop and Auto mode press the RUN/STOP button to switch to Manual Mode.

  2. Manual mode

    • In stop mode the display will now show MANUAL, LOW RPM and the speed in rpm.
    • Press the up or down buttons to select the speed. Alternatively press one of the systems, preset speed buttons LOW RPM, MEDI RPM, HIGH RPM.
    • Press the RUN/STOP button to put it into run mode, this will start the pump. When the chlorinator timer turns off, the CLEVER-POOL will store the speed and resume at that speed when switched on again.
    • To stop the pump simply press the RUN/STOP button again.
  3. Back Wash mode

    • In stop mode press the SET/RESET button once. The display will now show MANUAL, LOW RPM and the speed in rpm.
    • Press the BACKWASH button. The display will now show backwash and the rpm.
    • Press the RUN/STOP button to put it into on mode, this will start the pump.
    • Press the RUN/STOP button to stop the pump
  4. Time setting

    • Current time
    • In stop and Auto Mode, Press UP and Down button to set Current time,
    • Press the SET/RESET button to step over from hours to minutes. The display will then flash the minutes digits.  Press the SET/RESET button to store the time. The display will now show the current time with flashing cursor and the word shown at the top.
  5. Auto Mode timer and Speed setting

    • In stop mode press the SET/RESET button, The display should show CURRENT TIME, START TIME, STOP TIME and the stored
    • Press the up or down button to select the hours.
    • Press the SET/RESET button to step over from hours to minutes and from Start Time to Stop time
    • Press the SET/RESET button to step to SPEED setting. The display will now show the flashing four digits for speed,which is the speed for AUTO MODE 1.Press the up or down button to change motor speed. Alternatively press one of the systems preset speed buttons LOW RPM, MEDI RPM, HIGH RPM.
    • Press the SET/RESET button to store the speed and step over to AUTO MODE 2. The display should show CURRENT TIME, START TIME, STOP TIME and the stored time with hours digits flashing. This is the start time for AUTO MODE 2.
    • Repeat steps above to set speed, start and stop times for AUTO MODE 2 3 and 4. Pressing the SET/RESET button after selecting the speed for Auto mode 4 will finalize the timer settings.
    • The display will go blank and return to stop mode with the current set time displayed.
    • Alternatively if you only require one time period per day press the SET/RESET button to cycle through time a speed settings of the remaining TIMERS ensuring all start and stop times are set to zero’s or to the same time period. Please note all settings for AUTO MODE 1 to 4 will be retained in the event of power loss.
    • After all timers have been set.The CLEVER-POOL will then start and stop the pump at set times and speeds.

BUTTON AND FUCNTION EXPLANATION

Number Name Explanation
1 Power light Power supply connected or disconnected
2 Pump light Pump on or off
3 Increase Increase the parameter
4 Decrease Decrease the parameter
5 Full RPM Pump motor RPM setting
6 High RPM Pump motor RPM setting
7 Medium RPM Pump motor RPM setting
8 Low RPM Pump motor RPM setting
9 LCD screen Showing all parameters
10 Setting Parameter setting or re-set system
11 Run/Stop Manually control pump run or stop

PROTECTION AND TROUBLESHOOTING

ERROR CODE LIST AND EXPLANATION

  PROTECTION CODE EXPLANATION


1

| ****


Too Low voltage

| ****


LU

| When the voltage is below 160V it shows LU on the screen ,when the voltage comes normal from the grid, the error code disappears automatically.



2

| ****


Over voltage

| ****


OU

| When the voltage is over 285V it shows OU on the screen, when the voltage comes normal from the grid, the error code disappears automatically.




3

| ****


Over temperature

| ****



OC

| When the temperature in the casing is over 80 ℃, it shows OC on the screen till the temperature drops down to 55

℃, the error code disappears automatically.




4

| ****



Over load

| ****



OLD

| When the output ampere is 1.6 timers higher than the rated ampere and working for 15 seconds, it shows OLD on the screen, it needs to cut off the power supply and eliminate the problem, then re-plug the power for

normal work.




5

| ****



Short circuit

| ****



OLP

| When the output of the inverter is short-circuit,it shows OLP on the screen, it needs to cut off the power supply and eliminate the problem,then re-plug the power for normal work.




6

| ****


Lack phase (For 380V

version)

| ****



OP

| When there is a phase wire missing connection at the input, it shows OP on the screen and it needs to cut off the power supply and eliminate the problem,then re-plug the power for normal work.

Documents / Resources

| STARMATRIX Clever-Pool Pump Inverter [pdf] Instruction Manual
Clever-Pool Pump Inverter, Clever-Pool Inverter, Pump Inverter, Inverter
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals