Linshang LS233 Coating Thickness Gauge User Manual
- June 9, 2024
- Linshang
Table of Contents
LS233 Coating Thickness Gauge
User Manual LS233
Coating Thickness Gauge
User Manual V2.02
Please read this manual carefully before using and reserve it for reference.
Product Introduction
The coating
thickness gauge is professionally used for measuring the thickness of car
paint. The car body shell material is generally metal materials such as iron,
aluminum and non-metallic materials such as carbon fiber, plastic, etc. The
coating thickness gauge can measure the car paint thickness on iron and
aluminum substrates. . Moreover, it can identify not only non-metal car
bodies, but also the ferrous putty layer as well as the galvanized iron. The
gauge has two displays on the front and the top separately. The two displays
simultaneously display the test data. When measuring different positions of
the car body, it is convenient to view the test data. Among them, the front
display uses LCD, LCD ensures that the test results are clearly visible under
strong light. The top display uses OLED, OLED ensures normal display in a low
temperature environment of -40°C.
Standards for the product:
- DIN EN ISO 2808 Paints and Varnishes-Determination of Film Thickness
- JJG-818-2005 Verification Regulation of Magnetic and Eddy Current Measuring Instrument for Coating Thickness
- GB/T 4956-2003 Non-magnetic Coatings on Magnetic Substrates-Measurement of Coating Thickness-Magnetic Method
- GB/T 4957-2003 Non-conductive Coatings on Non-magnetic Basis Metals-Measurement of Coating Thickness-Eddy Current
Parameters
Probe tip | Ruby |
---|---|
Measuring principle | Fe: Hall Effect / NFe: Eddy current |
Probe type | Built-in integrated probe |
Measuring range | 0.0-3000pm |
Resolution | 0.1 pm:(Opm – 99.9pm) 1pm:(100pm – 999pm) 0.01mm:(1.00mm – 3.00mm) |
Accuracy | 5±(3(Y0H+2pm), H is the standard value |
Unit | μm / mil |
Measuring interval | 0.5s |
Minimum measuring area | Ø = 25mm |
Minimum curvature | Convex:5mm / Concave:25mm |
Minimum substrate thickness | Fe:0.2mm / NFe:0.05mm |
Display | Front: 128×48 dot matrix LCD, top: 128×64 dot matrix OLED |
Power supply | 2 pcs of 1.5V AAA alkaline battery |
Operation temperature range | -40℃-50℃ |
Storage temperature range | -50℃-60℃ |
Gauge size | 1006024 mm |
Weight(with battery) | 80g |
Features
- No calibration, just zero adjustment.
- Simple operation by pressing one button.
- Fast measurement, 0.5s measuring interval.
- Dual display design, display the measured value simultaneously. It is convenient to view the test data in real time when measuring at different angles.
- Using LCD and OLED as display devices simultaneously, LCD ensures that the test results are clearly visible under strong light and OLED ensures normal display in a low temperature environment of -40°C.
- The device can identify the ferrous putty as well as the galvanized iron substrate.
- Wear-proof ruby probe tip for long-term use.
- Dual-use probe for both iron and aluminum. The gauge can automatically identify the substrate and switch measurement mode rapidly.
- “Fe”, “NFe”, “Fe/NFe” three measurement modes can be set.
- The gauge can measure the non-magnetic coating thickness on metal substrates and nonconductive coating thickness on non-magnetic substrates.
- Use advanced digital probe technology, these sensors are unsusceptible to interference and provide an excellent measuring accuracy. Even temperature change will not affect measurement and data remain stable to ensure a very good reproducibility over the complete measuring range.
Operation
1. Power on/off
Power on:
Short press the power button to turn on the gauge. Display the version number
and serial number, then the recorded data of last measurement are displayed
after the gauge is turned on.
Power off:
Long press the button to shut down the gauge, or the gauge will automatically
shut down in 3 minutes without any operation.
2. Device setting
In the off state, long press the button for 3s to enter the setting
interface.After entering the setting interface, if there is no operation for
more than 20 s, the gauge will automatically shut down.Short press the button
can select the settings; Long press the button for 3 s and less than 5 s to
confirm the settings; long press the button for 5 s, the gauge exits the
setting and shuts down and the setting is invalid.
Language settings
The instrument is available in Chinese, English, Russian, Turkish.
Setting method: In the main setting interface, short press power button to
select “Language” option, long press the button for 3 seconds to confirm the
selection, short press the button again to select the desired language, long
press the button for 3 seconds to confirm the selection, and return to the
main setting interface. Measurement modes selection
It has three measurement modes: ferromagnetic substrate measurement mode (Fe),
non-ferrous substrate measurement mode (NFe) and automatic identification mode
(Fe/NFe). In general, the Fe/NFe mode is recommended. This mode features
identification of the ferrous putty and galvanized iron substrate. For
application with clearly indicated substrate, the Fe or NFe mode can be set as
a fixed mode.
Setting method: In the main setting interface, select “mode” option by short
pressing power button, and long press the button for 3 seconds to confirm the
selection. Shortly press the button to select the measurement mode. And long
press the button for 3s to confirm the selection and back to the main setting
interface. Unit setting
The device can be set to the metric or imperial unit, and the factory default
is metric.
Setting method: In the main setting interface, shortly press the button to
select “Unit”. Long press the button for 3s to confirm and then enter the unit
selection interface. Shortly press the button to select your unit and long
press the button for 3s to confirm and back to the main setting interface.
Exit
In the main setting interface, short press power button to select “Exit”, long
press the button for 3 seconds to confirm and enter the measurement interface
3. Zero adjustment
A zero-adjustment is required when using the gauge for the first time, after
inserting new batteries, working with different materials or ambient
temperature changes. Using iron-base and aluminum – base adjustment plates
respectively to carry out zero adjustment. We strictly recommend carrying out
the reference check on the uncoated original substrate, due to the difference
of magnetic and conductive properties of the material, some measurement
deviation will be caused. If this is not possible, please use the zero
reference plates supplied by Linshang technology, there are Fe plate and NFe
plate, please choose correctly according to the measuring materials.
3.1 Measuring the plate or uncoated original substrate, a measured value will
be displayed on the gauge, please make sure the probe tip is placed
perpendicularly and evenly on the surface.
3.2 Hold the probe still, long press the button for 3s, the gauge will display
“zero reference place probe” (as shown in below picture). 3.3 After hearing a buzzer sound, the gauge will display “Lift
off probe at least 15 cm” (as shown in below picture), release the button and
lift the probe away from the plate (substrate) for at least 15 cm. 3.4 The zero adjustment completed when there is the buzzer
sound again, and the LCD screen displays 0.0. 3.5 After the zero adjustment is completed, place the standard
film on the plate (substrate), if the measurement value is stable and
deviation from standard value within ±3μm, the gauge can be used normally.
Note: After the zero adjustment completed,when repeating measurement on the
same spot, the reading may not always be 0μm, since surface roughness, dirt,
scratches etc. It might cause variances. The operation of the gauge should be
correct and proficient; otherwise, it will lead to instability of the measured
values.
4. Measurement
- Use fingers to hold gauge where there is non-slip groove.
- Press the gauge vertically on the surface of the object to be measured. Keep the gauge steady and do not tilt or shake it. The result will be shown on the screen, and there will be a buzzer.
- To continue measuring, lift the gauge away from the object. Repeat the operation of step 2).
- When the device identifies the ferrous putty, the buzzer alerts for two times. And the interface of the device will prompt: “Ferrous putty”. When the device identifies the galvanized iron, it will turn on the green backlight. The substrate is displayed as “FeZn”.
5. Check measurement records
In measurement mode, short press the button to check historical data. The
gauge stores 9 sets of data.
When more than 9 sets of data are stored, the earliest recorded value is
automatically deleted, and “No.1” is the last test data. Recorded data will
not loss after powering off.
Precaution
- The device must be zero adjusted respectively with the iron-base and aluminum-base zero adjustment plates. Otherwise, there may be abnormal identifications of the ferrous putty and galvanized iron substrate.
- Do not slide the probe on the car surface, which will result in damage to the paint and the gauge.
- Please keep the car paint surface clean, the dust and dirt on the paint surface will affect the measurement accuracy.
- When the gauge displays “low battery”, the battery needs to be replaced.
Packing list
No. | Description | Quantity | Unit |
---|---|---|---|
1 | Coating Thickness Gauge | 1 | Set |
2 | Fe zero-adjustment plate | 1 | pcs |
3 | NFe zero-adjustment plate | 1 | pcs |
4 | Standard film | 1 | pcs |
5 | User manual | 1 | pcs |
6 | Drawstring bag | 1 | pcs |
7 | Certificate / Warranty card | 1 | pcs |
8 | 1.5V AAA alkaline battery | 2 | pcs |
Service
- The gauge has one-year warranty. If the gauge works abnormally, please send the whole gauge to our company for maintenance.
- Provide users with spare parts and lifelong maintenance services.
- Provide the users with the gauge calibration service.
- Free technical support for long term.
Manufacturer: Shenzhen Linshang Technology Co., Ltd.
Website: www.linshangtech.com
Service hotline: +86-755-86263411
Email: sales21@linshangtech.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>