FISHER PAYKEL 900MR805 Heater Wire Adapter Instruction Manual

June 10, 2024
Fisher & Paykel

Heater Wire Adapter
USER INSTRUCTIONS

900MR805 Heater Wire Adapter

FISHER PAYKEL 900MR805 Heater Wire Adapter - fig 1

Heater Wire Adapter User Instructions

Intended Use
The Heater Wire Adapter is designed for making electrical connection between Fisher & Paykel Healthcare MR850 and HC550 humidifiers and Fisher & Paykel Healthcare heated breathing circuits.
The 900MR805 adapter may be used with single or dual-limb heated breathing circuits, while the 900MR806 adapter can only be used with single-limb heated breathing circuits.

Specifications

Model Length (A) – (B) Length (A) – (C)
900MR805 450 mm (17.7 ”) 830 mm (32.7 “)
900MR806 450 mm (17.7 ”) N/A

Expected Service Life
3 years, if used in accordance with this User Instruction.
Note:
Service life may vary depending on usage pattern.

Setup

  1. Visually inspect entire product for damage before use. Discard if damaged.
  2. Insert the Heater Wire Adapter connector (A) to the yellow socket on the Humidifier.
  3. Connect the other end(s) (B, C) of the Heater Wire Adapter to the Breathing Circuit socket(s), as outlined in diagram.

Maintenance

Maintenance should be routinely performed. For further information, refer to the MR850 or HC550 Technical Manual (available from your local Fisher and Paykel Healthcare
representative).

Cleaning:
Using a damp cloth, clean the Heater Wire Adapter with either of the following – Isopropyl Alcohol or normal dishwashing detergent.

Notes

  • Follow these recommended cleaning procedures and the user instructions of the cleaning agents. It is the user’s responsibility to qualify any deviations from these procedures, both for disinfecting efficacy and physical effect.
  • Do not immerse this product in any liquid.
  • This product is not designed for autoclave sterilization process

WARNINGS

  • The use of breathing circuits, chambers, other accessories or parts which are not approved by Fisher & Paykel Healthcare may impair performance or compromise safety.
  • Failure to perform routine visible damage checks may impair performance or compromise safety.
  • No automated method for cleaning and disinfection is recommended.
  • California residents please be advised of the following, pursuant to Proposition 65: This product contains chemicals known to the State of California to cause cancer, birth defects and other reproductive harm. For more information, please visit: www.fphcare.com/prop65

Disposal
Dispose according to standard hospital guidelines for electrical and electronic equipment.

Symbol definitions

**** Consult operating instructions
Lot number
Reference number
**** Dispose of product in correct manner
Transportation and storage temperature limits
European Union authorised representative
Prescription only
CE Marking 93/42/EEC
Date of manufacture
Manufacturer
Transportation and storage humidity limitation
Medical Device

Manufacturer
Fisher & Paykel Healthcare Ltd, 15 Maurice Paykel Place, East Tamaki, Auckland 2013,
PO Box 14 348 Panmure, Auckland 1741, New Zealand
Tel: +64 9 574 0100 Fax: +64 9 574 0158
Email: info@fphcare.co.nz
Web: www.fphcare.com Importer/ Distributor
UK Fisher & Paykel Healthcare Ltd, Unit 16,
Cordwallis Park, Clivemont Road, Maidenhead, Berkshire SL6 7BU, UK
Tel: 0800 132 189
Fax: +44 1628 626 146
USA/Canada
Tel: 1800 446 3908 or +1 949 453 4000
Fax: +1 949 453 4001

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Fisher & Paykel User Manuals

Related Manuals