Facon CW-T1218 Recreational Vehicle Holding Tank Owner’s Manual
- June 4, 2024
- Facon
Table of Contents
RECREATIONAL VEHICLE HOLDING TANK, STEP, PIPE AND ELBOW HEATER PAD PROGRAM ** Owner’s Manual**
Facon ® Heater Pads are designed and engineered to protect RV holding
tanks, pipes, and steps from freezing. Properly sized and installed Facon
Heater Pads provide consistent & efficient protection as the first signs of
freezing winter weather approaches. Falcon ® offers a full line of products
including tank, pipe, elbow, and step heater pads allowing pleasurable use of
your RV during freezing winter temperatures.
Falcon ® Tank & Step Heater Pads are thermostatically controlled. They will
operate as long as sufficient electrical power is supplied to the RV. The
thermostat
is set to turn itself on at 45 ° ° F (5 C) and turn itself off when the
holding tank temperature reaches 68 ° F (20 0 C). As long as the on/off switch
is in the on position and electrical power is supplied, the thermostat will
continue to cycle preventing freezing.
HEATER PAD OWNER’S MANUAL INDEX
| CW-T825 up to 50gal.120VTANK HEATER
---|---
| CW-T1218 uptoS0gal.13.SVTANK HEATER
| CW-ST725 uptoS0gal.STEP/TANK HEATER
| CW-P312 PIPE HEATER
| CW-P618 PIPE HEATER
| CW-P712 PIPE HEATER
| CW-E38 PIPE ELBOW HEATER
| CW-E313 PIPE ELBOW HEATER
Tank Heater Pad
Model CW-T825 &CW-T825-L
120V AC 84 Watts
Up to 50 Gallons
MINIMUM INSTALLATION TEMPERATURE 68. F (20’C)
Manufacturers Heater Pads for the winter convenience of today’s RV’er. The
Model CW-T82S&CW-T825-L works efficiently up to SOgallons for holding tanks.
The tank heater pads are thermostatically controlled, designed to turn on at
45 ° 0 F (S C) and to turn off at 68 ° F (20ºC). Apply tank heater pads to
smooth and clean surfaces. Identify the lowest point on the holding tank,
closest to the drain. Clean the surface of the holding tank with isopropyl
alcohol and let it dry. Peel back the paper from the adhesive, and then press
firmly and smoothly over the intended placement area. DO NOT STRETCH THE PAD.
The CW-T825&CW-T825-L require 120V AC to operate at maximum efficiency. Please
ensure the connection to the proper voltage and the proper “on-off” switch is
used. The connection must be fused with the correct amperage. If two or more
tank heater pads are to be used they must be connected in parallel. Please
ensure after installation the lead wires are securely located and will not
hang below the surface of the tank.
CAUTION: a ground fault protection device must be used with this heating
device
ATTENTION: ce produit doit etre utilise avec une prctection de mise a la
terre
Specifications
Pad Dimensions | Pad Thickness | Lead Wire | Voltage | Amps | Watts |
---|---|---|---|---|---|
8″x25″ | 3.0mm | 36″ | 120VAC | 0.7 | 84 |
8″x25″ | 3.0mm | 144″ | 120VAC | 0.7 | 84 |
Manufacturers Heater Pads for the winter convenience of today’s RV’er. The
Model CW- T1218 works efficiently with up to 50-gallon holding tanks. The tank
heater pads are thermostatically controlled, designed to turn on at 45 ° F
(5°C)and to turn off at 68 °F (20ºC).
Apply tank heater pads to smooth and clean surfaces. Identify the lowest point
on the holding tank, closest to the drain. Clean the surface of the holding
tank with isopropyl alcohol and let it dry. Peel back the paper from the
adhesive, and then press firmly and smoothly over the intended placement area.
DO NOT STRETCH THE PAD. The CW-T1218 requires 13.5V DC to operate at maximum
efficiency. Please ensure the connection to the proper voltage and the proper
“on-off” switch is used. The connection must be fused with the correct
amperage. If two or more tank heater pads are to be used they must be
connected in parallel.
Please ensure after installation the lead wires are securely located and will
not hang below the surface of the tank.
Specifications
Pad Dimensions | Pad Thickness | Lead Wire | Voltage | Amps | Watts |
---|---|---|---|---|---|
12″ x18″ | 3.0mm | 36″ | 13. SV DC | 4.8 | 65 |
Manufacturers Heater Pads for the winter convenience of today’s RV’er. The
Model CW- ST725 works efficiently with up to 50-gallon holding tanks and
steps. The step/tank heater pads are thermostatically controlled, designed to
turn on at 45 ° 0 F (S C) and to turn off at 68 ° F (20° C).
Apply step/tank heater pads to smooth and clean surfaces. When installing on
tanks: identify the lowest point on the holding tank, closest to the drain.
Clean the surface of the holding tank with isopropyl alcohol and let it dry.
Peel back the paper from the adhesive, and then press firmly and smoothly over
the intended placement area. When installing on steps: clean the surface of
the step with isopropyl alcohol and let dry. Peel back the paper from the
adhesive, and then press firmly and smoothly over the intend es placement
area, DO NOT STRETCH THE PAD.
The CW-ST725 requires 13. SV DC to operate at maximum efficiency. Please
ensure the connection t9 the proper voltage and the proper “on-off” switch is
used. The connection must be fused with the correct amperage. If two or more
step/tank heater pads are to be used they must be connected in parallel.
Please ensure after installation the lead wires are securely located and will
not hang below the surface of the tank.
Specifications
Pad Dimensions | Pad Thickness | Lead Wire | Voltage | Amps | Watts |
---|---|---|---|---|---|
71/4″x 25″ | 3.0mm | 36″ | 13. SV DC | 5.8 | 78 |
Manufacturers Heater Pads for the winter convenience of today’s RV’er. The
Model CW- P312 works efficiently on 1/2″ pipes.
Apply pipe heater pads to smooth and clean surfaces. Clean the surface of the
pipe with isopropyl alcohol and let it dry. Peel back the paper from the
adhesive then press firmly and smoothly over the intended placement area. DO
NOT STRETCH THE PAD.
The CW- P312 requires 13. SV DC to operate at maximum efficiency. Please
ensure the connection to the proper voltage and the proper “on-off” switch is
used. The connection must be fused with the correct amperage. If two or more
pipe heater pads are to be used they must be connected in parallel.
Please ensure after installation the lead wires are properly secured. Pipe
heater pads are not thermostatically controlled. Pipe insulation may be used
with model CW- P312.
Specifications
Pad Dimensions | Pad Thickness | Lead Wire | Voltage | Amps | Watts |
---|---|---|---|---|---|
3″x12″ | 3.0mm | 18″ | 13.5V DC | 0.52 | 7 |
Manufacturers Heater Pads for the winter convenience of today’s RV’er. The
Model CW-P618 works efficiently on 11/2″ pipes.
Apply pipe heater pads to smooth and clean surfaces. Clean the surface of the
pipe with isopropyl alcohol and let it dry. Peel back the paper from the
adhesive then press firmly and smoothly over the intended placement area. DO
NOT STRETCH THE PAD.
The CW-P618 requires 13. SV DC to operate at maximum efficiency. Please ensure
the connection to the proper voltage and the proper “on-off” switch are used.
The connection must be fused with the correct amper age. If two or more pipe
heater pads are to be used they must be connected in parallel.
Please ensure after installation the lead wires are properly secured. Pipe
heater pads are not thermostatically controlled. Pipe insulation may be used
with model CW-P618.Pad Dimensions| Pad Thickness| Lead Wire| Voltage| Amps|
Watts
---|---|---|---|---|---
6″ x18″| 3.0mm| 18″| 13. SV DC| 1.8| 24
Manufacturers Heater Pads for the winter convenience of today’s RV’er. The
Model CW-P712 works efficiently on 3″ pipes.
Apply pipe heater pads to smooth and clean surfaces. Clean the surface of the
pipe with isopropyl alcohol and let it dry. Peel back the paper from the
adhesive then press firmly and smoothly over the intended placement area. DO
NOT STRETCH THE PAD.
The CW-P712 requires 13. SV DC to operate at maximum efficiency. Please ensure
the connection to the proper voltage and the proper “on-off” switch is used.
The connection must be fused with the correct amper age. If two or more pipe
heater pads are to be used they must be connected in parallel. Please ensure
after installation the lead wires are properly secured. Pipe heater pads are
not thermostatically controlled. Pipe insulation may be used with model
CW-P712.
Pad Dimensions | Pad Thickness | Lead Wire | Voltage | Amps | Watts |
---|---|---|---|---|---|
71/2″ X 12″ | 3.0mm | 18″ | 13. SVDC | 1.7 | 23 |
Manufacturers Heater Pads for the winter convenience of today’s RV’er. The
Model CW-E38 works efficiently on 1 1/2″ pipe elbows. Apply pipe elbow heater
pads to smooth and clean surfaces. Clean the surface of the pipe with
isopropyl alcohol and let dry. Peel back of paper from the adhesive then press
firmly and smoothly over the intended placement area. DO NOT STRETCH THE PAD.
The CW-E38 requires 13.SV DC to operate at maximum efficiency. Please ensure
the connection to the proper voltage and the proper “on-off” switch is used.
The connection must be fused with the correct amper age. If two or more pi£>e
elbow heater pads are to be used they must be connected in parallel. Please
ensure after installation the lead wires are properly secured. Pipe elbow
heater pads are not thermostatically controlled. Pipe insulation may be used
with model CW-E38.Pad Dimensions| Pad Thickness| Lead Wire| Voltage| Amps|
Watts
---|---|---|---|---|---
3″x8″| 3.0mm| 18″| 13.SV DC| 0.3| 4
Manufacturers Heater Pads for the winter convenience of today’s RV’er. The
Model CW-E313 works efficiently on 3″ pipe elbows. Apply pipe elbow heater
pads to smooth and clean surfaces. Clean the surface of the pipe with
isopropyl alcohol and let dry.Peel back of the paper from the adhesive then
press firmly and smoothly over the intended placement area. DO NOT STRETCH THE
PAD. The CW-E313 requires 13.SV DC to operate at maximum efficiency. Please
ensure the connection to the proper voltage and the proper “on-off” switch is
used. The connection must be fused with the correct amper age. If two or
r:nore pipe elbow heater pads are to be used they must be connected in
parallel.
Please ensure after installation the lead wires are properly secured. Pipe
elbow heater pads are not thermostatically controlled. Pipe insulation may be
used with model CW-E313.
Pad Dimensions | Pad Thickness | Lead Wire | Voltage | Amps | Watts |
---|---|---|---|---|---|
3″ X 13″ | 3.0mm | 18″ | 13. SVDC | 0.55 | 7.5 |
FREQUENTLY ASKED QUESTIONS
Question: What is the warranty period?****
– Answer: All Heater Pads have a two-year Limited Warranty.
Question: What maintenance must be performed on the Heater Pads?****
– Answer: No maintenance is required. Simply turn the ON/OFF switch to the ON position when the weather approaches 45 ° F.
Question: How do I ensure proper operation of the Heater Pad?****
– Answer: The thermostatically controlled Tank & Step
Heater Pads will operate efficiently and automatically. Turn the ON/OFF switch
to ON when the outside temperature approaches 45 ° F.
For pipe and elbow heater pads, connect wiring directly to the ON/OFF switch.
Question: What if no water is in the tank?****
– Answer: No harm will come to the tank if there is no water in the tank.
However, if the tanks have been drained the ON/OFF switch should be turned
off.
If turned on the thermostat will continue to cycle, turning the Heater Pad off
and on.
R COGN IZED COM PON l:NT E10681
Certified to CSA STD C22.2
NO.130-03 and UL499
US PATENT: us10.2;1.888 Bl
CHINA PATENT: ZL 20082009576 <,_2 ZL 200 20095767.7
Read User Manual Online (PDF format)