DELL A03 LCD Monitor User Manual
- June 9, 2024
- Dell
Table of Contents
- DELL A03 LCD Monitor
- Revision history
- Product Description
- New features
- Known issues
- 2 and is routed to the port group #1.
- Limitations
- Environment and system requirements
- Software media, organization, and files
- Documentation
- Where to get help
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
DELL A03 LCD Monitor
These release notes contain supplemental information about this Unity
release. Current Release Version: 5.2.2.0.5.004
Release Type : Minor (MI)
Revision history
This section provides a description of document changes.
Document revision | Date | Description |
---|---|---|
A03 | January 2023 | Rele a se 5.2.2.0.5.004 |
A02 | July 2022 | Release 5.2.1.0.5.013 |
A01 | June 2022 | Updates to New and Changed Features sections for system |
hardware
A00| April 2022| Initial release, 5.2.0.0.5.173
Product Description
- Dell Unity is targeted for midsized deployments, remote or branch offices, and cost-sensitive mixed workloads. Unity systems are designed for all-Flash, deliver the best value in the market, and are available in purpose-built (all Flash or hybrid Flash), converged deployment options (through VxBlock), and a software-defined virtual edition.
The Dell Unity Family consists of:
-
Unity (purpose built): A modern midrange storage solution, engineered from the ground-up to meet market demands for Flash, affordability and incredible simplicity. The Unity XT Family consists of 4 Hybrid Flash configurations
(380/480/680/880) and 4 All Flash configurations (380F/480F/680F/880F) models. -
VxBlock (converged): Unity storage options are also available in Dell VxBlock System 1000.
-
UnityVSA (virtual): The Unity Virtual Storage Appliance (VSA) allows the advanced unified storage and data management features of the Unity family to be easily deployed on VMware ESXi servers, for a ‘software defined’ approach. UnityVSA is available in two editions:
-
Community Edition is a free downloadable 4 TB solution recommended for non-production use.
-
Professional Edition is a licensed subscription-based offering available at capacity levels of 10 TB, 25 TB, 50 TB, and 350 TB. The subscription includes access to online support resources, EMC Secure Remote Services (ESRS), and on-call software- and systems-related support.
-
All three Unity, UnityVSA, and Unity-based VxBlock deployment options enjoy one architecture, one interface with consistent features and rich data services.
Unity is Redefining Storage Simplicity and Value
- Here are some of the features and supporting statements that allows Unity to redefine midrange storage:
- Simple: Simplified ordering, all-inclusive software, rack-and-stack in less than 2 minutes, customer installable, a new slick HTML5 user interface, proactive assist, and CloudIQ internet-enabled monitoring.
- Modern : Unity is designed to support the latest dense Flash drives such as 3D TLC NAND with a Linux-based architecture, new Intel Haswell, Broadwell, and Skylake multicore processors, up to 440K IOPS, 2U dense configurations, scalable 64bit file system & file system shrink, unified snapshots & replication, Data-at-Rest-Encryption (D@RE), support for public and private cloud access, deep ecosystem integration with VMware (native vVols) and Microsoft, and much more.
- Affordable: Unity delivers the best midrange Flash economics with a great entry price and overall TCO. Unity All Flash configurations start under $15K and Unity Hybrid Flash configurations start under $10K. UnityVSA allows anyone to get started for free and upgrade into the supported virtual edition, a purpose-built hybrid or all-Flash system, or into converged infrastructure.
- Flexible: You can meet any storage deployment requirement with Unity from virtual to purpose-built to converged infrastructure. All deployment options support the same data unified data services (SAN/NAS and vVols) to support any workload with traditional file (file consolidation, VDI user data, home directories) as well as transactional workloads for both file and block on both all Flash and hybrid configurations (Oracle, Exchange, SQL Server, SharePoint, SAP, VMware and Microsoft Hyper-V).
Unity XT Platform (380/F, 480/F, 680/F, 880/F series)
- The Unity Next Generation Platform refresh, also known as the Unity XT Series, consists of 8 hardware models, including 4 Hybrid Flash and 4 All Flash configurations—the Dell Unity 380, 380F, 480, 480F, 680, 680F, 880, and 880F. The XT series increases performance of I/O, maximizes storage efficiency features like Advanced Data
- Reduction with inline deduplication, and supports a 25Gb interface card.
- The Unity 380(F) is based on the existing platform today for the 350F model, but with additional memory (64GBs per SP).
- The Unity 480/F, 680/F, and 880/F are built on an Intel Skylake platform. For more information, see the Unity 380/F, 480/F, 680/F, and 880/F Hardware Information Guide.
- The Unity XT series supports Advanced Data Reduction in both dynamic and traditional pools in All Flash (F) models, and All Flash pools in Hybrid models.
- Unity software OE version 5.x and later supports the new x80 series models, in addition to all existing x00 and x50 series models.
- Note: The Unity XT 480/F, 680/F, and 880/F are available for both high-line (200v-240v) and low-line (100v-120v) power environments, but you must select the appropriate option when ordering your system. Low-line is used in a select countries that supply 100-120V, typically through a wall outlet, while high-line is used in environments that supply 200-240V. Country-specific cables are available for plugging a Unity system directly into a wall outlet that either supplies 100-120V or 200-240V.
- If supplying 100-120V to a Unity XT 880/F, a step-up transformer is required.
New features
- No new features in this release.
Changed features
- No changed features in this release.
Resolved issues
- This table lists the issues fixed in this release. For all issues fixed in previous releases, refer to the release notes for that specific Unity OE.
Resolved issues in the product version
Issue ID | Functional area | Description |
---|---|---|
UNITYD-58433/ UNITYD-56826 | Connectivity – networks | When a static global IPv6 |
address is used for Unisphere, an IPv6 link local address cannot be used as a
gateway for Unisphere.
UNITYD-58434/
UNITYD-57571
| Serviceability| Calls home are stopped, requiring a restart of the primary
SP.
UNITYD-58432/ UNITYD-54738| Serviceability| When the service command
svc_topstats is used with the “fs.qtreeFile” statistic to monitor multiple
file system quotas, an exception error might occur.
UNITYD-58425/ UNITYD-54591| Serviceability| A large number of events prevents
Unisphere event logs from updating.
UNITYD-58427/ UNITYD-56489| Storage – Block| If you use Veritas Infoscale, you
might see a Data Unavailable (DU) condition after you upgrade to Unity OE
version 5.2.0.x. or later.
UNITYD-58423/ UNITYD-52054| Storage – Block| Dropped Fibre Channel data frames
might cause unexpectedly high latencies.
Issue ID| Functional area| Description
---|---|---
UNITYD-58494/ UNITYD-58032| Storage – File| When you run OE version 5.2.0.x or
5.2.1.x and use Kerberos authentication, the SP might reboot unexpectedly and
go into service mode if the DC server sends an empty subkey.
UNITYD-58435/ UNITYD-58040| Storage – File| When you perform a failover and
reboot the primary SP, ConnectEMC will likely be disabled on the primary SP
after failover.
UNITYD-58431/ UNITYD-55206| Storage – File| A timestamp later than 19-Jan-2038
03:14 a.m. UTC cannot be set using SMB.
UNITYD-58430/ UNITYD-54096| Storage – File| When a file is opened as read-only
and that file is later flushed, Unity incorrectly reports a “success” status.
UNITYD-58429/ UNITYD-56481| Storage – File| If you are running OE versions
5.2.0.x or 5.2.1.x, running SFTP as a regular workload might cause an
unexpected SP reboot.
UNITYD-58428/ UNITYD-57480| Storage – File| If you are running OE versions
5.2.0.x or 5.2.1.x, some HP printers and scanners might fail to create files
under the root directory of the file system.
UNITYD-58426/ UNITYD-55225| Storage – File| A storage processor might reboot
unexpectedly when you try to set attributes using NFSv4.
UNITYD-58424/ UNITYD-55075| Storage – File| When you create a thick file
system and then shrink it to a smaller size, the free space on the file system
cannot be returned to the pool.
Known issues
Known issues in the product version
Issue ID | Functional area | Description | Workaround/Solution |
---|---|---|---|
UNITED-59598 | Storage – File | If SFTP compression is enabled, an unexpected SP | |
reboot might occur if you are running OE versions 5.2.1.x or 5.2.2.x. | None. | ||
869166 | Common Event Enabler | When a host is configured to use CAVA for the |
CEPA server, there is a host IO error on SMB protocol with the following message in the logs:
“Too many access from CAVA server xx.xx.xx.xx without the EMC VirusChecking privilege:>>> User credential (xx.xx.xx.xx address of the host).”
| Do not use CAVA/CEPA NAS servers for regular host IO.
UNITED-50686| Connectivity – Hosts| LED light may not be On when inserting
either a 32G or 16G SFP into a 4-port 32Gb Fibre Channel I/O module slot.|
Remove and reinsert the SFP card.
UNITYD-55879/ UNITYD-56227| Connectivity – Networks| The NAS Server cannot
ping the hostname through the IPv6 interface in Unisphere UI
NAS/Network/Ping/Trace page, even though the hostname has an IPv6 address.|
Use the ping6 command on the SP where the NAS Server is located. For example:
ping6
UNITED-52587| Connectivity – Networks| During an SP reboot, mgmt_dev may not
have an IP address configured correctly, causing the operation to fail with
error code 0x100000a and the following message:
“The system was unable to connect to the storage server.”
| Reboot the primary SP.
UNITED-46552| Connectivity – Networks| When a NAS server networking base is on
a hierarchy fail-safe network (FSN) which has| Reboot the affected SP.
Issue ID| Functional area| Description| Workaround/Solution
---|---|---|---
| | Link Aggregation (LACP) bonds as child ports, and the MTU of the FSN is
changed, the child LACP bonds may be degraded or inaccessible.|
UNITYD-42194| Connectivity – Networks| In rare cases, if a link aggregation or
fail-safe network (FSN) link is composed of two or more ports on a 4-port
1-GbE BaseT I/O module, changing the MTU speed for the link aggregation or FSN
may cause an SP reboot.| First, modify the MTU speeds of the ports on the
4-port 1-GbE BaseT I/O module to the expected values. Then, modify the MTU
speed of the link aggregation or FSN.
932347/ UNITYD-
5837
| Connectivity – Networks| Immediately upon creation, the Fail-Safe Network (FSN) appears in a “Link Down” state. An alert similar to the following is displayed. “System XXX has experienced one or more problems that have had a minor impact” With a detailed description of
“The system has experienced one or more minor failures. Check related alerts and fix the underlying problems.”
| If all Ethernet ports participating in this FSN port, either directly or
using Link Aggregation, are connected properly, the FSN port will
automatically recover from “Link Down” state within 30 seconds or less. It is
also possible that FSN port recovery goes through “Degraded” state, for
approximately 60 seconds after the FSN creation. This alert can be ignored,
unless the FSN port fails to enter the “Link Up” and “Health OK” state
approximately 60 seconds after creation.
UNITYD-46251| Data collection| When performing a minimum data collection, the
collection result may be named as “minimumspa(b).tar”, indicating it is
for one SP only, instead of “minimumunity.tar”.| Collect a minimum
profile data collection on the two SPs separately. Normal data collection may
work correctly after 1000 seconds.
UNITYD-55786/ UNITYD-56194| Data mobility| Migration session stops when
importing a node fails.| When a node has failed, remove the node from the
migration session.
When the migration session enters the “Commit” state, select to Commit the session. Then manually copy the failed node to the Unity side.
UNITYD-54629| Data mobility| Only the SMB1 protocol is supported for a Unified
VNX (VNX1 or VNX2) storage system as the source storage system in a VDM file
migration.| If either the SMB2 or SMB3 protocol is used on the VNX source
system, the protocol must be changed to SMB1 before performing the migration.
UNITYD-54862| Data mobility| If you use an atypical advanced replication
configuration, such as using asynchronous replication inbound and synchronous
replication outbound, the synchronous replication destination NAS server
sometimes becomes faulted during a planned failover of asynchronous
replication.| Before performing the planned failover asynchronous replication
session, pause the synchronous replication session first. After the planned
failover asynchronous replication session completes, resume the synchronous
replication session.
UNITYD-51634| Data mobility| In MetroSync when the MetroSync Manager is
configured, if the MetroSync Manager detects that the source pool is offline,
it initiates an unplanned failover. Even if the unplanned failover succeeds,
the source site may not be cleaned up correctly, and the subsequent failback
may fail.| Delete the synchronous session and recreate it but note that a full
synchronization will occur.
UNITYD-51288| Data mobility| When deleting a synchronous replication of a NAS
server, if the peer SP is rebooting gracefully, the delete operation may
fail.| Retry to delete the synchronous replication operation.
Issue ID| Functional area| Description| Workaround/Solution
---|---|---|---
UNITYD-46362| Data mobility| When the system in a busy status, there is a rare
chance that the local move operation returns an error message such as “Failed
to clean up NAS server replication service”.| Wait some time and retry the NAS
server local move operation.
UNITYD-46339| Data mobility| There is a very small chance an asynchronous
replication session gets stuck at 99%, and the session cannot be paused.|
Reboot the owner SP of the asynchronous replication destination LUN. Refer to
Knowledge Base article 000187383 for more information.
UNITYD-45838| Data mobility| When verifying a remote system, if one local
replication interface on the current Unity system can successfully ping a
remote replication interface on another remote Unity system, but the ping
fails the other way around, the verification will fail with error code
0x65002db and the corresponding error message will display:
“Failed to retrieve connectable replication interfaces between the local system and the remote system. Verify that there is at least one connectable replication interface between the local SP and the remote SP by running the ‘uemcli /net/util ping -srcIf \{0} – addr \{1}’ command. Then retry the original command again.”
The \{0} and \{1} values will display the actual interface ID value and IP address value respectively, but do not.
| Go to the remote Unity system and verify the same remote system, then the
same error message will be correctly displayed with \{0} and \{1} values
properly populated.
943734/ UNITYD-
4469
| Data mobility| The “Last sync time” of a replication session is updated, but
“transfer remaining size” is not zero.| Wait about 2 minutes, then view the
replication session details again.
906249/ UNITYD-
2788
| Data mobility| A request to create a replication session for VMware NFS
datastore which resides in a multiprotocol NAS server will fail until the
first synchronization of the associated NAS server replication session.|
Synchronize the NAS server replication session at least once prior to creating
a replication session for a VMware NFS datastore residing on the multiprotocol
NAS server.
UNITYD-46300| Data protection| Rarely, a replication session reports a ‘Non-
recoverable error’.| Pause and resume the replication session.
UNITYD-45110| Data protection| When the system is configured with a large
number of replications (over 1000) and both SPs are rebooted simultaneously,
one storage processor may experience an additional reboot after system comes
back up.| No manual operation needed.
The system will automatically recover after the reboot.
UNITYD-45005| Data protection| When failing back or resuming a file synchronous replication session after an unplanned failover, if an asynchronous replication is also configured on the NAS server, this triggers an unexpected storage processor reboot.| Before failing back or resuming the synchronous replication session, pause the asynchronous replication on the NAS server.
After the synchronous replication session is failed back, resume the
asynchronous replication session.
UNITYD-36280| Data protection| The snapshot schedule function failed to create
a scheduled snapshot of a synchronous replication-protected file system during
the session failback operation.| None.
Issue ID| Functional area| Description| Workaround/Solution
---|---|---|---
UNITYD-31870| Data protection| The snapshot schedule timer reset (restarted
from 0) after the Unity management service was rebooted, or a new resource was
assigned to it. This leads to this schedule being applied to existing
resources.| None.
981344/ UNITYD-6289| Data protection| There are three Arrays: A, B, C. The
following scenario occurs:
1. Site A-B set up synchronous replication sessions.
2. Site A-C set up asynchronous replication sessions.
3. Shut down site A and do a cabinet failover on B.
4. Preserve all asynchronous replication sessions immediately on B.
Some asynchronous replication sessions are not preserved. (No Error message in Site B. The asynchronous replication sessions which are not preserved will be “Lost Communication” in Site C.)
| 1. To prevent this issue, wait two minutes after the failover, then run the preserve operation.
2. If this issue occurs, rerun the preserve operation.
949119 / UNITYD-
4769/ UNITYD-
5112
| Data protection| If an NDMP restore restores a file which exceeds a quota
hard limit, the file will be restored as owned by the root user.| The
administrator should manually increase the quota limitation for the user and
correct the file ownership.
821501| Data protection| When a user runs a token-based incremental backup
using Networker, a full backup is performed instead.| Add ATTEMPT_TBB=Y to
Application Information while configuring the NDMP client, or change the value
in the NDMP client properties.
875485| Data protection| The following error could be returned when multiple
snap diff REST API requests were sent in parallel.
“‘{ “error”: { “created”:
“2016-12-05T17:34:36.533Z”,
“errorCode”: 131149826,
“httpStatusCode”: 503, “messages”:
[ { “en-US”: “The system is busy. Try again later. If the problem persists, search for the error code on the support website or product forums, or contact your service provider, if available. (Error Code:
0x7d13002)” } ] } }”
| Reduce the number of parallel operations and try again.
917298| Data protection| NAS_A or NAS_B and related user VDMs failed to
recover due to error occurs in the system VDM NAS_A or NAS_B, as seen in the
Unisphere CLI or UI.
After following the recommended resolution steps in the health details, the NAS servers are recovered and go into a ready state. However, the replication sessions on these system VDMs and related user VDMs will no longer be visible.
| After recovery, reboot the primary SP. After the SP reboot, system NAS
servers will be recovered successfully, allowing replication sessions to be
recovered.
Issue ID| Functional area| Description| Workaround/Solution
---|---|---|---
UNITYD-52402/ UNITYD-53032| Hardware| Unity OE versions do not support a Fibre
Channel direct attach of either the Emulex LPe 31/3200x or LPe 35/3600x host
HBAs running their version 12.8 or later firmware.| For a Fibre Channel direct
attach, use either Emulex HBAs that use firmware version 12.8 or earlier, or
use Qlogic HBAs.
17379| Hardware| In some Unity XT 480/F, 680/F, and 880/F model DPEs, the Non-
maskable Interrupt (NMI) (hard reset) button is misaligned.| Press the NMI
button at an angle. Refer to KB 000022355 for more information.
UNITYD-46441| Import| A VNX VDM configured with a standalone DFS is not
supported by a CIFS-only migration.| None.
UNITYD-45678| Import| When both SPs are recovered from a power outage or
rebooted at the same time an in- progress SMB or multiprotocol migration
session could be impacted in one of the following ways:
1. The session could be stuck in initial copy stage.
2. The session could report a “Major failure” during the incremental copy stage.
3. Cancelling the session could fail while turning down the destination interface.
| Reboot the VDM owner SP on the VNX source system.
UNITYD-31523| Import| When using a “UNIX” access policy, if a domain user
belongs to “domain admin” or the “administrators” group, files created by the
user will use “administrators” as owner, which is expected behavior for
Windows.
If using an NFS client to list these files, the file owner is the user.
After migration, the owner of the files from the CIFS client will be the “administrator”, and the owner of files from NFS client will be “2151678452”. This may cause some files created by the CIFS client before migration cut over to be inaccessible by the NFS client after migration cutting over.
| Change the owner to the correct user.
938977/ UNITYD-
4327
| Import| When creating a remote system for file import, when the SANCopy
connection is created and the remote system is verified prior to starting a
block import, the SANCopy host is not created, so the user cannot create a
block import session.| Delete and recreate the remote system. After re-
creating the remote system, the SANCopy host can be created successfully.
969495| Import| If a pool out-of-space event occurs on a destination Unity
array after a file migration session cutover from VNX to Unity, it is possible
that some folders and files are lost on the Unity array. Although the
migration session can resume and complete after expanding the destination
pool, no warning or error message will occur mentioning that data may be
missing.| 1. Always plan to have enough space on the destination pool
before starting a migration. Extra buffer space may be needed if there might
be continuous large I/O during the migration.
2. If a pool out-of-space event does occur after cutover, cancel the migration session, and start again by creating a new session.
Issue ID | Functional area | Description | Workaround/Solution |
---|
952772/ UNITYD-
5971
| Notifications and Alerts| A misleading alert
“Unable to detect Ethernet port or link aggregation for the network interface N/A configured on NAS server %1.”
displays during NAS server deletion, even though it completes successfully.
| Ignore the erroneous alert.
999112| Notifications and Alerts| The health description for Ethernet port is
incorrect; it shows that this port was not in used, but in fact it was used
for some file interfaces.| Bring up the ethernet port and then the health
status and description will be updated.
UNITYD-29557| REST API| Normally a REST API user authentication failure
returns a 401 or 403 error code. However, if a session ticket is reused after
the associated user account is deleted from the system, the request will
instead fail with a ‘500’ error.| Clear the browser or REST client cache to
remove the stale session ticket.
UNITYD-44958| Software Install and Upgrade| During an upgrade from Unity OE
5.0.x to
5.1.x on Unity XT 480/480F, 680/680F, 880/880F systems, due to the firmware contents change between 5.0 and 5.1, in the first reboot cycle, a firmware upgrade was started.
During this short time window, if an unexpected firmware issue occurred, this leads to the firmware becoming corrupted and it cannot be recovered by a system reboot or power cycle. The SP goes into service mode after the firmware upgrade fails.
| None. Refer to Knowledge Base article 000195767 for more information.
908930| Storage – Block| Even when snap auto delete is disabled on the storage
pool, the storage pool may still show a degraded state indicating it could not
reach low water mark.| Use the CLI to increase the pool space low water mark
in order to bring the pool back to normal state. For example:
uemcli -u xxx -p xxx / stor/config/pool
–id pool_97 set – snapPoolFullLWM 40
UNITYD-54408| Storage – File| Running a user quota command with the
“-async” parameter when a file system has millions of files, a performance issue may occur.
| Reboot the SP.
UNITYD-54287| Storage – File| Using Unisphere to manually shrink a file system
to the Used Size causes the operation to stop responding.| Cancel the shrink
operation from Unisphere.
UNITYD-54010| Storage – File| VDM failover happens when a file system auto-
extend operation begins due to a file system running out of space, which
results in an SP reboot and I/O write failure.| Reboot the SP in which the
extend operation was last run to recover the system.
UNITYD-53835| Storage – File| A trusted subdomain user cannot access an SMB
share when using an incorrect “\\nas_server\share /user:subDomain\user
Password” command.| Use the “\\nas_server\share
/user:user@subDomain Password” command instead.
128333021/ UNITYD-52094/ UNITYD-53457| Storage – File| After upgrading to
Unity OE version 5.1.x, the audit log path and size are reset to the
defaults.| Change the “cifs userDefinedLogFiles” parameter to 0 and restart
the VDM. Refer to Knowledge Base article 000193985 for more information.
Issue ID| Functional area| Description| Workaround/Solution
---|---|---|---
UNITYD-51284| Storage – File| When creating many asynchronous replication
sessions concurrently by using automatic scripts, the sessions may partially
fail.| Delete any failed replication sessions from the destination system, and
reconfigure them one at a time.
119078191 / UNITYD-48904/ UNITYD-53251| Storage – File| When adding a new
interface to a NAS server, if the preferred interface has an “auto” setting,
the preferred interface is not switched to the newly added one if it has same
gateway availability and number of routes as the currently active preferred
interface.| Either make a specific interface to be the preferred interface, or
make sure the DNS servers added with the new interface are active before
adding it.
20199488/ UNITYD-45132/ UNITYD-53297| Storage – File| During specific
circumstances when a file system becomes full and is made Read-Only, the file
cannot be deleted as expected.
However, the return code from Unity system does not adhere to the RFC. There is no loss of functionality.
| None.
855767/ UNITYD-
1261
| Storage – File| When you customize a list of CIFS Shares Access Control Entries (ACEs) by either making a REST API call, editing the share permission using the Windows MMC console, or by using the SMI-S API, isACEEnabled might erroneously indicate false.| Ignore the value isACEEnabled=false in this case. When ACEs are properly set, they are always enabled, despite this value in the REST API attribute. A REST API request for list of ACEs will return the correct list of custom ACEs for the share, and those ACEs will all apply.
Alternatively, force a reload of the management model for the share by changing the share description, or for the whole system by restarting the management software.
942923/ UNITYD-
7663
| Storage – File| If you have set different user quotas on a non-
multiprotocol SMB file system that you are changing to a multiprotocol file
system, the Remapping File Owner process will not preserve the specific user
quotas you had set previously. If the user quotas are all the same or (have
default value), this issue does not occur.| After remapping users to their
Unix user counterpart, re-issue the specific User Quota settings.
959208/ UNITYD-
5257
| Storage – File| If an LDAP user is configured before Directory Services
(LDAP) is configured, and a local user account with the same name exists, the
array will report that the LDAP user already exists, instead of ‘not found in
the LDAP database’.| Configure LDAP and reboot the SP Then, add the LDAP user
(role) again. This will be allowed even if a local user with the same account
name exists.
974999| Storage – File| When opening or deleting a locked file from an FLR-
enabled file system on a Windows client, sometimes there are several
additional log events generated in the FLR activity log.| This issue will not
happen on NFS client, and it just generates some additional log events, which
can be seen by administrator. Ignore these log events.
975192| Storage – File| When automatic file locking is enabled on an FLR-
enabled file system, a file on an SMB share can be locked automatically.
However, the file mode property might not be updated and will not indicate the
file is read-only even though it is protected.| Use the FLR Toolkit to
determine whether the file is automatically locked instead of the SMB client.
Issue ID| Functional area| Description| Workaround/Solution
---|---|---|---
1035681/ UNITYD-
| Storage – File| If the LDAP configuration on a destination NAS server is different from the source NAS server, such as the following scenarios, the LDAP password will be lost and the new source NAS server cannot connect to the LDAP server after failover.
1. DST NAS overrides the IP.
2. SRC NAS changes the configuration, such as the authentication type, server IP, etc., but did not sync to the DST NAS server.
| Re-enter the password in the new source NAS server after failover.
UNITYD-52201| System management| When trying to create or expand a traditional
pool with the following conditions, the listed drive count available for a
tier might be 0 due to an internal timeout error (>10mins):
1. RAID5 with maximum capacity option.
2. The disk group for this tier has 500+ free drives.
| Use one of the following options to fix the issue:
· Use the CLI to expand the pool.
· Use either Unisphere or the CLI to create a dynamic pool that contains some of the drives in the large disk group, reducing the free drive count in the disk group to be less than 500. Then use Unisphere to expand the original traditional pool.
896002| System management| If a Unity system uses NTP forsynchronization, when
the time is adjusted to an earlier time from the current time, real-time
system metrics do not appear, and the system generates “Query ID not found
(0x7d1400c)” errors.| In Unisphere, navigate to another page and then return
to the metrics page, or log out of Unisphere and log in again.
973979| System management| When you create a file system named \”\’, the SMB
share page in the GUI does not display the proper description for the shares
associated with file system named \”\’ and the UEMCLI does not display the
proper values for the shares associated with file system named
\”\’.
| Do not name file system \”\”.
998582/ UNITYD-7835| Unisphere UI| When there are many storage resources
configured on the array, (for example, 6000 LUNs and 2000 file systems),
filtering the LUNs using a keyword for the LUN name in the Unisphere UI may
take over five minutes, and then show an error message if there are multiple
matches (1500+ matches).| Reload the Unisphere UI, then choose a more specific
keyword that matches fewer LUNs, or do not use keyword filters on large
configurations.
UNITYD-46074| Unisphere UI| On the Unisphere UI File Systems properties dialog
Snapshots tab, the “Last Refresh Time” attribute is not available.| Use the
CLI to obtain the “Last Refresh Time” attribute value for the file system
snapshot.
UNITYD-46064| Unisphere UI| If the size of source thin file system is greater
than the destination pool size, it will show the following warning message
“The selected pool doesn’t have enough free space to create destination File System” when changing the recommended destination pool
| Close the view and reopen it.
Issue ID| Functional area| Description| Workaround/Solution
---|---|---|---
| | for the file system to the smaller destination pool.|
921511/ UNITYD-3397| Unisphere UI| Unisphere returns the following message:
“Your security session has expired. You will be redirected to the loginpage.”|
Confirm that the Unisphere login account in use is still active has Storage
Admin privileges. Be sure to close the active browser session before logging
with another account.
946287/ UNITYD-
4572
| Unisphere UI| When logging into Unisphere as one user and then trying to log
in as another user without restarting the browser, some login information is
cached by the browser and this will result in afailure.| Restart the browser
to log in successfully.
968227/ UNITYD-
5636
| Unisphere UI| In rare circumstances, when a user creates a snapshot by using the Unisphere UI, an unexpected error may occur. However, the actual snapshot creation completed successfully. The newly created snapshot will display immediately.
The unexpected error occurs because the REST API failed to fetch the snapshot ID.
| Ignore the error if the newly created snapshot appears.
849914| Unisphere UI| The Job Details page in Unisphere does not display the
name of a LUN group after it failed to be deleted.| There is no workaround for
this issue.
907158| Unisphere UI| After upgrading from a system running Unity OE 4.0 or
4.1, the Unisphere UI did not allow the NAS server SP owner to be changed|
Clear browser cookies to and refresh Unisphere.
995936
UNITYD-7474
| Unisphere UI| Incorrect drive health information may display in the Unisphere UI if switching a SAS cable from an onboard SAS port to backend SLIC port. FBE show these drives as “OK” while Unisphere shows these drives as faulted.
For example, if switching the SAS cable from SAS port 0 to backend SLIC port 0, then DAE 0_0 becomes DAE 2_0, and the related disks change from Disk 0_0_X to Disk 2_0_X . Unisphere will display these drives as faulted.
| 1. Identify the primary SP in Unisphere under Service à Service tasks.
2. Reboot the primary SP using the svc_shutdown -r service command.
895052| UnityVSA| SSH is disabled after a single-Storage Processor UnityVSA
upgrade.| After performing a Unity OE upgrade, re-enable SSH using Unisphere
or the following Unisphere service command: svc_ssh -e.
945773| UnityVSA| The following error displays on the UnityVSA:
“Error : <CPU of the physical server hosting UnityVSA does not meet the CPU instruction set minimum requirement (SSE4.2 or greater) for upgrading to this release or later.> Action: Migrate the UnityVSA to a server with a CPU that supports SSE4.2 or greater, or deploy a new UnityVSA on a CPU that supports SSE4.2 or greater. Then retry the upgrade.”
| When upgrading the UnityVSA to Unity
4.3 or deploying a new 4.3 UnityVSA on an older server that does not support CPU instruction set SSE4.2, migrate the VSA offline to another VMware ESXi server or cluster.
If the upgrade fails on the ESXi cluster and that cluster contains any servers that do not support CPU instruction set SSE4.2, modify the Enhanced vMotion Capability (EVC) settings within the
VMware cluster to disallow vMotion
Issue ID | Functional area | Description | Workaround/Solution |
---|---|---|---|
from the newer servers that support SSE4.2 to the older servers. |
Remove the older servers from their cluster. Power cycle the UnityVSA and retry the upgrade.
933016| UnityVSA| The system reports an alert that the network heartbeat is questionable on the peer when the local physical network cable is broken.
This occurs when:
1. UnityVSA SPA runs in the physical server #1, UnityVSA SPB runs in the physical server #2.
2. The physical network cable #1 connects the uplink #1 of server #1 and the physical switch.
3. The physical network cable #2 connects the uplink #2 of server #2 and the physical switch.
4. The physical network cable #3 connects the uplink #1 of server #1 and the physical switch.
5. The physical network cable #4 connects the uplink #2 of server #2 and the physical switch.
6. When one of the physical network cables #1 or #2 is broken or pulled out, the system reports the alert. But if you pull out cable #1, the alert would be reported on SPB. If you pull out the cable #2, the alert would be reported on SPA.
7. When one of the physical network cables #3 or #4 is broken or pulled out, the system would report alert. But if you pull out cable #3, the alert would be reported on SPB. If you pull out the cable #4, the alert would be reported on SPA.
This happens because the UnityVSA vNIC #1 is connected to the port group #1 and NIC #2 to the port group #2. Also, by the VMware teaming function, port group #1 has been bound to uplink #1 and port group #2 to uplink #2. It is expected that after pulling out cable #1 (the physical uplink #1 is down), the traffic going through NIC #1, port group #1, uplink #1 should be cut off. However, because of a VMware limitation, the teaming only controls the egress, but not the ingress. The traffic sent from NIC #1 is truly cut off, but the traffic from the peer’s port group #1 still comes through the physical uplink
2 and is routed to the port group #1.
| None.
801368 /
802226
| UnityVSA| The storage system restarts unexpectedly with a monitor timeout or software watchdog timeout. This occurs when the system and user data share the same datastores (physical disks) and the system is overloaded with aggressive I/O workloads.| It is recommended that user storage be on a separate data store than the system data store where UnityVSA is deployed.
If that is not possible, ensure that there are no more than four virtual disks on
Issue ID | Functional area | Description | Workaround/Solution |
---|---|---|---|
For example, a system can become overloaded when the workload includes | |||
heavy sequential write block I/O mixed with random file read and write I/O. |
the system data store. If user data is allocated on the system data store, it
can be migrated to a different data store. See the vSphere documentation for
details. For UnityVSA deployment considerations, see the UnityVSA
Installation Guide.
809371| UnityVSA| When configuring a NAS server for replication from a Unity
system to a UnityVSA system, the user can choose a storage processor on the
destination, although a single-SP UnityVSA has only one storage processor (SP
A). Choosing SP B and continuing to create the session results in an error.|
Choose SP A when replicating to a single-SP UnityVSA.
UNITYD-44726| Virtualization| If a VMware traditional datastore is extended
which does not have any host access, then host access cannot be added later.|
Delete the VMware datastore and recreate it. A datastore that has never had
any host access is supposed to be a clean datastore with no data.
940223 /
945505 / UNITYD-4468
| Virtualization| A VM migration (using vMotion) to or from NFS3-NFS4
datastore sporadically fails when an SP is rebooted during migration.|
Manually restart the vMotion migration when the SP is back online.
811020| Virtualization| When there are no datastores enabled for access to a
target ESXi host during replication, the storage system iSCSI targets are not
registered on the target ESXi server. When the Storage Replication Adapter
(SRA) requests that the storage system enable Snaps-Only access to the target
ESXi server, the operation succeeds, but rescan does not discover the
snapshots.| Manually configure iSCSI target discovery of the storage systems
iSCSI addresses on the ESXi hosts.
987324| Virtualization| With multiple VM clones from the same source VM, part
of clone could fail.
vCenter Server reports events similar to:
Unable to access file xxx.vmdk since it is locked.
| To work around the issue in ESXi 5.0 or later, increase the number of times to retry opening the disk:
1. Log in to the ESXi host with root credentials.
2. Open the /etc/vmware/config file using a text editor.
3. Add this line to the end of the file: diskLib.openRetries=xx
[Where xx depends on the number of virtual machines being deployed in the vApp. VMware recommends a value between 20 and 50.]
4. Save and close the file.
5. Reboot the host for the changes to take effect.
988933| Virtualization| When using Dell Virtual Storage Integrator (VSI), VMware datastore creation fails on Unity All Flash and UnityVSA systems.| The issue is fixed in VSI 8.1. Refer to the following Knowledgebase articles for details:
· UnityVSA: KB# 163429
· Unity All Flash: KB# 36884
989789| Virtualization| When a VM migration in VMware vSphere is in progress,
a planned failover of the underlying synchronous replication file system| Do
not perform a synchronous replication planned failover on Unity while
migrating a VM on VMware
Issue ID| Functional area| Description| Workaround/Solution
---|---|---|---
| | on Unity at the same time may cause VM migration failure on vSphere.|
vSphere at the same time. If the error occurs, wait until planned failover
completes and retry the VM migration in VMware vSphere.
Limitations
Learn about limitations in Unity.
Limitations in the product version
Limitation | First affected release | Limitation lifted |
---|
In a replication cascading topology from an asynchronous replication session
to a synchronous replication session, the synchronous replication destination
data integration is not integrated.| 5.2.0.0.5.173| Still in effect.
Moving drives between Unity x80/F models and non-x80/F models is not
supported. This ensures that the drives are qualified and configured for the
correct platform and will provide optimal performance and longevity.|
5.1.0.0.5.394| Still in effect.
After a failover, the UNIX and Windows names may not display immediately and
could take up to 24 hours to display. You can manually refresh the username
for a UID or wait until the next system refresh to see the correct names.|
5.1.0.0.5.394| Still in effect.
A large thick file system (TB level) takes time to provision, even after the
operation returns a success message in Unisphere. While the provisioning
operation is in progress, many operations, such as asynchronous replication
creation, cannot be run and will fail due to timing out. Operating on a newly-
created thick file system after a certain amount of time is recommended. Run a
query to check the status of the operation.| All versions| Still in effect.
When replicating VMware VMFS datastores, they are treated like Consistency
Groups in that they are subject to the same replication limits as CGs (for
example, the maximum number of replication sessions for CGs is 64, which also
applies to VMFS datastores).| All versions| Still in effect.
Using VSI 7.4 or VSI 8.0 to create a VMFS Datastore on a Unity all Flash array
or UnityVSA will fail. It is recommended to always provision VMFS datastores
and vVols through the Unity Unisphere UI or CLI.| All versions| Still in
effect.
VMware vSphere 6.5 is not supported on the UnityVSA 4.1.x.| 4.1.0.8940590|
4.2.0.9392909
When setting I/O limit policies, observe the following restrictions:
· For a shared KBPS I/O limit policy, set the limit to be at least 2048 KBPS.
· For a non-shared KBPS I/O limit policy, set the limit to be at least 1024 KBPS.
· The IOPS I/O limit policy’s minimum is 100 IOPS.
| 4.0.0.7329527| Still in effect.
The current Unity vVol implementation has not yet been fully certified for use
with VMware Horizon View. Although it may work, it is recommended that you do
not deploy VDI desktops using Unity vVol datastores. Support and issue
resolution will not be available for this integration.| 4.0.0.7329527| Still
in effect.
Environment and system requirements
- In order for your Unity Family system to function properly, ensure that your environment meets these minimal requirements.
Support matrix
- Refer to the Unity Support Matrix on the support website for compatibility and interoperability information.
Screen size
- The minimum resolution for using the Unisphere GUI is 1024 x 768 pixels. Smaller screens may be able to display the GUI in full screen mode.
SRSVE (Centralized) and DHCP
- Dynamic IP addresses (DHCP) cannot be used for any EMC Secure Remote Services Virtual Edition (ESRS VE or Centralized ESRS) component (ESRS VE servers, Policy Manager, or managed devices). You must assign static IP addresses to those devices that you plan to have managed by ESRS VE.
- Unity Hybrid and All Flash support both the Centralized and Integrated versions of ESRS VE. UnityVSA supports the Centralized version of ESRS VE only. More information about the ESRS VE is available in the Dell Unity Secure Remote Services Requirements and Configuration document.
- Note : If the system automatically assigns a dynamic IP address to any ESRS VE component, you must change it to a static IP address. Also, leases for the IP addresses that Dell devices use cannot be set to expire.
Software media, organization, and files
- Learn about software media, organization, and files required for the Unity Family.
Required update
- It is recommended that you keep your Unity Family system up to date by upgrading to the latest software version at your earliest opportunity.
Problems downloading this release
- If you have difficulty downloading this release using Microsoft Internet Explorer version 7, try using a newer version of Microsoft Internet Explorer, Google Chrome, or
- Mozilla Firefox version 4 or greater.
Obtain and install product licenses
Before you begin:
- Register your product. This provides you instant access to easy-to-use tools to plan, install, maintain, and service your product. It also entitles you to software updates, installation tools, and more.
- Ensure that you have the following:
- License authorization code (LAC)—The LAC is sent by email from Dell.
- The system serial number (physical systems) or the system UUID (virtual systems).
- Before you can create storage, you must install product and feature licenses on your system.
Initial Configuration
- On the Unisphere Licenses page of the Initial Configuration wizard, select Get License Online.
- Follow the instructions on the licensing website and download the license file locally.
- Note: Do not change the name of the license file.
- Select Install License and use Chose File to browse to the license file you downloaded locally.
- Select Open.
- The Results page will confirm the license was successfully installed.
Obtaining and installing additional licenses after initial configuration
- In Unisphere, select the Settings icon, and then select Software and Licenses > License Information.
- Select a product license from the list to display a description of that license.
- To obtain a product license, select Get License Online.
- a. Use the link provided in the LAC email or access the product page on the support website, and download the license file locally.
- Note: Do not change the name of the license file.
- b. Transfer the license file to a computer that has access to the storage system, or connect the computer you used to obtain the license file to the same subnet of the storage system.
- To upload a product license, select Install License.
- a. Review the Software License and Maintenance Agreement and select Accept license agreement.
- b. Locate the license file, select it, and select Open to install the license file on the storage system.
- The license file is installed on the storage system.
- For sites with restricted internet access, or for more information on obtaining your license, go to the Unity Info Hub at dell.com/unitydocs.
Unique identifier for UnityVSA
- For UnityVSA, use the License Activation Key instead of the serial number or UUID as the unique identifier for setting up EMC Secure Remote Services (ESRS) and for obtaining customer support (professional editions).
Installing and enabling language packs
To install a language pack:
- Review the considerations included in the Software Media, Organization, and Files section.
- In Unisphere, select the Settings icon, and then select Software and Licenses > Language Packs.
- Select Obtain Language Pack Online and enter your Support credentials when prompted.
- Download the appropriate language pack file to your local system.
- Return to Unisphere and select Install Language Pack to launch the Install Language Pack wizard.
- Select Choose File and then select the language pack you want to upload.
- Select Next to begin the installation of the language pack onto your system.
- Select Finish.
- Once language package installation completes, view the results and close.
To enable a language pack on your system:
- In Unisphere, select the My Account icon and select Preferences.
- Select the preferred language from the Language list.
- Select OK.
Firmware
- Drive firmware bundle version 20 is included in this software OE bundle. Once the software OE installation has completed, a prompt appears if updates are available. However, it is recommended to upgrade to the latest drive firmware prior to a software upgrade to help mitigate any non-disruptive upgrade issues. For a list of all drive firmware and their respective drives, refer to Knowledge Base article 000021322 (previously article 000490700).
The following firmware variants are included with this release:
- If a lower revision is installed, the firmware is automatically upgraded to the revision contained in this version.
- If a higher revision is running, the firmware is not downgraded to the revision contained in this version.
Enclosure Type | Firmware |
---|---|
3U, 15-drive DAE | 2.38.10 |
2U, 25-drive DAE | 2.38.10 |
3U, 80-drive DAE | 2.38.10 |
DPE expander | 2.38.10 |
Platform Type | BIOS |
--- | --- |
2U, 25-drive DPE | 60.02 |
2U, 12-drive DPE | 60.02 |
2U, 25-drive DPE Unity XT 480/F, 680/F, and 880/F | 66.07 |
Documentation
Unity Family Info Hubs
- Additional relevant documentation can be obtained from the Unity Family Info Hub. Visit the Info Hub for your Unity Family product to access helpful utilities, videos, and other guides and https://www.dell.com/unitydocs.
Where to get help
- The Dell Technologies Support site ( https://www.dell.com/support) contains important information about products and services including drivers, installation packages, product documentation, knowledge base articles, and advisories.
- A valid support contract and account might be required to access all the available information about a specific Dell Technologies product or service.
Advisories
- For information on an individual technical or security advisory, go to the Online Support website and search by using the DSA number or “Dell Security Advisories” as the keyword.
- You can also select an option to receive alerts for Dell Technical Advisories (DTAs) and Dell Security Advisories (DSAs) to stay informed of critical issues and prevent potential impact to your environment. Go to your account settings and preferences in Online Support, type the name of an individual product, click to select it from the list, and then click Add Alert. For the individual product or All Dell Products, enable the DTA’s and/or DSA’s toggle.
Notes, cautions, and warnings
- NOTE: A NOTE indicates important information that helps you make better use of your product.
- CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates potential for property damage, personal injury, or death.
- © 2016 – 2023 Dell Inc. or its subsidiaries. All rights reserved. Dell Technologies, Dell, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners.
References
- Dell Unity Info Hub: Product documents and information | Dell US
- Dell Unity Info Hub: Product documents and information | Dell US
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>