IMPORTANT SAFETY INSTRUCTIONS

  • Read, keep, and follow these instructions.
  • Heed all warnings:
    • This D-BOX Haptic System may be harmful to women who are pregnant, persons with heart conditions, the elderly, or those with other pre-existing medical conditions. All such persons should consult their physicians before using this D-BOX Haptic System.
    • Use of this D-BOX Haptic System poses a risk to hands and feet. Do not put hands or feet underneath the seat or near the haptic system. Doing so may lead to serious injury.
    • The use of hot liquids in the vicinity of this D-BOX Haptic System should always be avoided to prevent spillage, which could cause serious injuries to the user.
    • Do not use this device near water.
    • Only clean the device with a dry cloth.
    • Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
    • Protect all the cables (USB, network, power, etc.) from being walked on or pinched, particularly at the ends.
    • Use only attachments/accessories specified by the manufacturer.
    • Use of this D-BOX Haptic System is not recommended for children under the age of ten (10) without adult supervision. Owners and/or users of this D-BOX Haptic System should consult and comply with the user guide enclosed herein.
    • Unplug this device during electrical storms or when unused for long periods of time.
    • Do not install near any heat sources such as radiators, heat registers, stoves or any other appliances (including amplifiers).
    • Refer all servicing to qualified personnel. Servicing is required when the device has been damaged in any way. For example: if liquid has been spilled or objects have fallen onto it, if it has been exposed to rain or moisture, if it does not operate normally or, it has been dropped.

Owners and/or users of this D-BOX Haptic System are responsible for the dissemination of this information to all such persons named herein. Each owner and/or user of this D-BOX Haptic System agrees to evaluate and bear all risks associated with the use of this D-BOX Haptic System for themselves and for any subsequent users of this D-BOX Haptic System. Any subsequent users of this D-BOX Haptic System shall be deemed to be using this D-BOX Haptic System under the direct supervision of such owner/user and such owner/user will be deemed to have communicated this advisory to all persons described herein.
D-BOX Technologies Inc. is in no way responsible for damages of any kind arising from the use of this D-BOX Haptic System. The owners and/or users of this D-BOX Haptic System hereby agree not to hold D-BOX Technologies Inc. responsible for any and all damages of any kind arising from the use of this D-BOX Haptic System. These damages include, but are not limited to, direct or indirect damages, punitive damages, and incidental, special or consequential damages arising out of or in any way connected with the use of this D-BOX Haptic System.

INTRODUCTION

The D-BOX System Configuration is a free software tool used to update and configure your G2, G3 or G5 haptic systems.
Haptic System users can use the System Configurator to:

  • Update the firmware of the KCU-1P and associated D-BOX hardware (G2 & G3).
  • Configure (or modify) your Haptic System.
  • Change the Master – Slave ACMs arrangement (G3 Only).

If you require a reconfiguration on your G1 motion system, please contact our support team.

BEFORE RUNNING THE SYSTEM CONFIGURATOR

Haptic System Generations

For G2 & G3 haptic systems, each ACM holds a programming specific to its actuator’s configuration (firmware + programming).
For G5 haptic systems, firmware & programming are applied to the Haptic Bridge (ACM Master) and Haptic Actuator (ACM Slave).D0-BOX 194-914-0010-EN6 System
Configurator app 9

ACM Arrangement (Master/Slave)

For a G2 or a G3 haptic system, each ACM is assigned following its position in the system. It is programmed either as:

  • ACM Master:  Mandatory to be the first ACM in the chain from the KCU-1P
  • ACM Slave:    All following ACMs in the chain (if needed)

For G2 & G3, the ACM arrangement is shown by a sticker indicating Master or Slave on the ACM itself.
Please refer to your haptic system User Guide for more details about how to connect your system.
For G5, the Haptic Bridge is considered as a Master ACM and each haptic actuator as a Slave ACM.

Haptic Actuator Positions

The logo used to represent the actuator positions is a man sitting on a sofa (top view). The following figure describes the characters used to define the actuator positions:

LEGEND POSITION PICTOGRAM REFERENCE
FL Front-Left
FC Front-Center
FR Front-Right
BL Back-Left
BC Back-Center
BR Back-Right
SU Surge
SW Sway
Y Yaw

SOFTWARE INSTALLATION

The D-BOX System Configurator is compatible with Microsoft Windows 7, 8, 10 & 11 – 64 bits.

STARTING THE SYSTEM CONFIGURATOR

Do not interrupt the update process while it is running. Interrupting the update process before it is completed may cause improper operation. Please contact D-BOX support if you experience improper operation.

  • STEP 1: Connect the hardware to your computer. See your haptic system User Guide if necessary.
  • STEP 2: Start the D-BOX System Configuration software D0-BOX 194-914-0010-EN6 System Configurator app 11
    NOTE: Running the software requires administrative privileges.

FIRMWARE UPDATE

The Firmware update tab is the active tab when you start the application. This tab allows you to update the firmware of the following equipment:

  • Haptic Bridge and Haptic Actuator (G5 only)
  • ACM, KCU-1P, KCA & KCA-T (G2 & G3 only)

A firmware update can also change the actuator model (G3 only). For example, if you replace 1.5-inch actuators by 3-inch actuators, you need to update the firmware. See section 5.1 for more details.
NOTE: Firmware update applies to a KCU-1P and all subcomponents. If you have multiple KCU-1P, you need to update them one at a time.

  • STEP 1: Click the Refresh Firmware Status button. This action refreshes the status of the firmware and updates the status to outdated (if a newer firmware is available) or up to date (if the latest firmware is already in use):
    Example for a G5 Haptic System:
    D0-BOX 194-914-0010-EN6 System Configurator app 12
    Example for G2 or G3 (KCU-1P):
    D0-BOX 194-914-0010-EN6 System Configurator app 13
    The device icon displays its status. The possible values are:Device Icon| Status| Action required
    ---|---|---
    | Unknown: Refresh firmware status| Initial status. Refresh the status using the Refresh Firmware Status button.
    | Outdated firmware should be updated| A newer firmware is available. Update firmware by using the Update Firmware button.
    | Up to date: No action required| The latest firmware is installed. No action required.
  • STEP 2: If your components are outdated, select the Haptic Bridge (G5) or KCU-1P (G2 & G3) you want to update then press the Update Firmware button. A dialog box will appear asking you if you want to proceed with update. Click OK: D0-BOX 194-914-0010-EN6 System Configurator app 17NOTE: The update process may take a few minutes. You can click the Execution Details button at any time to read details about the ongoing operation:
    D0-BOX 194-914-0010-EN6 System Configurator app 18Once the update process is complete, the following window will appear. Click OK:D0-BOX 194-914-0010-EN6 System Configurator app
19
Changing the Actuator Type (G3 Only)

You may only be prompted to change the actuator type if:

  • The G3 hardware connected is the new configuration you wish to use (Ex: 3-inch actuators instead of 1.5-inch actuators).
  • This configuration is different from the old configuration for which the ACM was initially configured (Ex: 1.5-inch actuators).

NOTE: If a G2 system is connected, you may not use this function.
When there is a mismatch between the configured actuator(s) and the connected actuator(s), the following window appears:D0-BOX 194-914-0010-EN6 System
Configurator app 20

  • STEP 1: Select the KCU-1P device then click Update Firmware. Follow the onscreen instructions:
    D0-BOX 194-914-0010-EN6 System Configurator app 21
    D0-BOX 194-914-0010-EN6 System Configurator app 22
    D0-BOX 194-914-0010-EN6 System Configurator app 23Once the operation is completed, click OK. Your haptic system is now up to date:D0-BOX 194-914-0010-EN6 System Configurator app
24

CONFIGURATION UPDATE

The Configuration Update tab allows you to:

  • Configure your Haptic System (haptic actuator positions and axes (Degree of Freedom – DOF))
  • Change the position assigned to each actuator.
  • Change the number of actuators in the configuration.
  • Modify the number of ACM (G2 & G3 only) in the configuration.

NOTE: Here are the possible axes (DOF) that can be configured for a D-BOX Haptic System:

  • STEP 1: From the Hardware Selection box, select the communication device (Haptic Bridge (G5) or KCU-1P (G2 & G3)) linked to the motion system(s) you want to configure, then select the platform number (if multiple haptic systems are connected): D0-BOX 194-914-0010-EN6 System Configurator app 26The Actual DOF Configuration box shows the actual configuration. There is no selection to be done in this section:

  • STEP 2: The DOF Configuration Filter box helps you to find the available configurations for your haptic system:D0-BOX 194-914-0010-EN6 System Configurator app 27 OPTION A: If you know the number of the configuration, you can enter it manually into the Configuration box (see Appendix A & B for common configurations)
    OPTION B: Filter by configuration attributes (see Appendix A & B for common configurations):

    • Validate that the number of ACMs detected is accurate. If it is not the case, check the system connections and click on the Refresh Information button.
      NOTE: The G5 Haptic Bridge is considered an ACM.

    • Validate that the number of actuators detected match your requested configuration. Otherwise, you can manually change the value as desired.

    • Optional: Check the boxes of the desired axes (degrees of freedom) you want.

  • STEP 3: The Configuration and Description section shows the list of all the available configurations using the information you entered in the Configuration Filter. D0-BOX 194-914-0010-EN6 System Configurator app 28By selecting a configuration, its layout appears in the Compatible Configuration Selection box. The layout displays the following elements:

    • The ACM connected and their arrangement – Master and Slave(s).
    • The haptic actuator(s) connected, their assigned connection slot (Haptic Bridge or ACM).
    • The haptic actuator(s) physical positions on the simulatorD0-BOX 194-914-0010-EN6 System Configurator app 30
  • STEP 4 Once the configuration is chosen, click the Apply Configuration button to start the configuration update process, then follow the onscreen instructions: D0-BOX 194-914-0010-EN6 System Configurator app 31
    D0-BOX 194-914-0010-EN6 System Configurator app 32Once the configuration update is complete, the following confirmation window appears. Click OK:D0-BOX 194-914-0010-EN6 System
Configurator app 33

ACM REARRANGEMENT (G3 ONLY)

The ACM Rearrangement tab allows you to change the arrangement of an ACM from Master to Slave and vice-versa.
Please note the following:

  1. If an ACM Master is connected, only the ‘’Switch to Slave ACM’’ button is available.
  2. Conversely, if an ACM Slave is connected, only the ‘’Switch to Master ACM’’ button is available. Connect only one (1) ACM at a time to the KCU-1P to perform this operation.
  • STEP 1 : Click on the Refresh Firmware Status button to view the actual configuration of the ACM.

  • STEP 2: Click the Switch to Slave ACM (or Switch to Master ACM) button if you want to switch your ACM from ‘’Master’’ to ‘’Slave” or vice-versa: D0-BOX 194-914-0010-EN6 System Configurator app 34NOTE: You can click the Execution Details button at any time to read details about the ongoing operation.
    Once the ACM is configured:

    • Replace the ACM arrangement sticker on top of the ACM.
    • Rearrange the connections between ACMs (see User Guide if needed).
    • Run your application to check if your Haptic System is in good operational order.

APPENDIX A: G5 COMMON CONFIGURATIONS (1 – 3 DOF)

D0-BOX 194-914-0010-EN6 System Configurator app 41

APPENDIX B: G2/G3 COMMON CONFIGURATIONS (1 – 3 DOF)

D0-BOX 194-914-0010-EN6 System Configurator app 42