Overview

Aptronics Pettway Indoor/Outdoor Ethernet over Fiber Poe+ Hardened Switches provide a 1Gb SFP port and three (3) Poe+ (30W) ports or up to two (2) Hi-Poe (60W) ports, passing data and power to Poe/Poe+ compliant devices. Cameras/edge devices may be located up to 100m from the unit. Features also include an integral battery charger for applications requiring backup and embedded LINQ Technology to monitor, control, and report power and diagnostics from anywhere.

Features

Agency Listings:

  • UL/cull Listed for Information Technology Equipment (UL 60950-1), Information Technology Equipment to Be Installed Outdoors (UL 60950-22).
  • CE European Conformity.

Input:

  • 115VAC, 60 Hz, 2.5A or 230VAC, 50/60 Hz, 1.3A. NetWaySP3B/NetWaySP3WPN:
    48- 55V UL Listed ITE power supply (up to 120W).

Power Output:

  • Three (3) ports Poe+ (30W) or up to two (2) Hi-Poe (60W) ports.
  • IEEE 802.3at (30W) and IEEE 802.3af (15W) compliant.
  • 120W total power.
  • Integral surge protection.

Fiber Port:

  • One (1) Gigabit SFP port.
  • Use with SFP module 1000Base-X (1Gb), compliant to Class 1 laser product (not included).

Ethernet:

  • Three (3) 10/100/1000 MPs ports.
  • Connectivity: RJ45, auto-crossover.
  • Wire type: 4-pair CAT5e or better structured cable.
  • Distance: up to 100m.
  • Speed: 10/100/1000Mbps, half/full duplex, auto negotiation.

Battery Backup:

  • Built-in charger for sealed lead acid or gel type batteries.
  • Battery charging circuit: 48VDC, 300mA.
  • Automatic switch over to stand-by battery when AC fails.

LEDs:

  • Individual PoE On LEDs for each port.
  • Individual IP Link status, 10/100Base-T/active

LEDs for each port.

  • ALOS LED indicates fiber connection for SFP port.
  • Heartbeat LED indicates proper operation of the unit.

Applications:

  • Provides Poe / Poe+ / Hi-Poe for cameras/devices.
  • Aptronics Spectrum switches can be used as a switching node in daisy chain and ring network

Configurations.

  • Spectrum switches can pass VLAN 802.IQ protocol.
  • Spectrum switches can pass SNMP protocol.

Environmental:

  • Refer to Technical Specifications Chart on page 4 for Environmental Conditions.

LINQ Technology:

  • Remote network management allows for camera/device reset and monitoring.
  • Poe port management via Dashboard IP management program.
  • Provides local and/or remote access to critical information via LAN/WAN.
  • Report real-time diagnostics.
  • Event log tracks history.

Accessories:

  • NetWaySP1A – Ethernet over Fiber Media Converter/Repeater -for applications requiring an additional SFP (Fiber) port (Fig. 2, pg. 6).
Mechanical

NetWaySP3WP

  • NEMA4/4X, IP66 Rated enclosure for outdoor use.
  • Dimensions (H x W x D approx.):13.31” x 11.31” x 5.59”(338.1mm x 287.3mm x 142mm).

NetWaySP3WPN

  • NEMA4/4X, IP66 Rated enclosure for outdoor use.
  • Dimensions (H x W x D approx.):13.31” x 11.31” x 5.59”(338.1mm x 287.3mm x 142mm).

NetWaySP3WPX

  • NEMA4/4X, IP66 Rated enclosure for outdoor use.
  • Accommodates four (4) 12VDC/4AH batteries(48V of backup).
  • Dimensions (H x W x D approx.):17.53” x 15.3” x 6.67”(445.3mm x 388.6mm x 169.4mm).

NetWaySP3X

  • Dimensions (H x W x D approx.):13.5” x 13” x 3.25”(342.9mm x 330.2mm x 82.6mm)

NetWaySP3PL

  • Dimensions (H x W x D approx.):10.75” x 8.875” x 2.375”(273.1mm x 225.4mm x 60.3mm).

NetWaySP3B

  • Dimensions (L x W x D approx.):5.625” x 4.5” x 0.625”(158.8mm x 142.9mm x 15.9mm).

Mounting Instructions

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. All units should be installed by a trained service personnel.

NetWaySP3WP/SP3WPN/SP3WPX Enclosure Mounting and Installation:

Altronix-NETWAYSP3PL-3-Port-Ethernet-over-Fibe-PoE-plus-Hardened-
Switches-01

  1. Remove backplane from enclosure prior to drilling. Do not discard hardware.
    Note: Make sure that hardware will not interfere with components of the circuit board.

  2. Mark and drill desired inlets on the enclosure to facilitate wiring. Maximum NEMA type 4X rated fittings to be used are 0.5”. Follow manufacturer’s specifications for the appropriate size opening.
    Note: Inlets for conduit fittings should only be made on the bottom of the enclosure. UL Listed NEMA type 4X rated conduit connector/hubs shall be used for the appropriate size inlets.

  3. Clean out the inside of enclosure before remounting circuit board.

  4. Mounting NEMA4/4X rated enclosure (Enclosure Dimensions, pgs. 11-12): Wall mount: Mount unit in desired location. Mark and drill holes to line up with the top and bottom holes of the enclosure flange. Secure enclosure with appropriate fasteners (e. g. screws and anchors; bolts and locking nuts, etc.) that are compatible with mounting surface and are of sufficient length/construction to ensure a secure mount (Fig. 4, pg. 8). Pole Mount: Refer to Figs. 5 – 9, pg. 8.
    Note: All inlets for conduit fittings should be on the bottom of the enclosure.

  5. Mount backplane in enclosure with hardware.

  6. To facilitate wire entry utilize weather-tight NEMA rated connectors (supplied), bushings, and cable.

NetWaySP3X Enclosure Mounting and Installation:

  1. Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the enclosure. Install two (2) upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two (2) upper screws; level and secure. Mark the position of the lower two (2) holes. Remove the enclosure. Drill the lower holes and install two fasteners. Place the enclosure’s upper keyholes over the two (2) upper screws. Install the two (2) lower screws and make sure to
    tighten all screws (Enclosure Dimensions, pg. 9). Secure enclosure to earth ground.

NetWaySP3B/SP3PL Mounting and Installation:

  1. Mount board/backplane in the desired location/enclosure with hardware supplied. NetWaySP3B: Connect 56VDC/120W max power source to terminal marked [+] and [–].
  2. Note: For proper earth ground connections on NetWaySP3B fasten metal spacers (provided) to threaded studs at indicated board mounting holes (shown on the right). This is recommended for better environmental immunity.

Installation Instructions:

  1. For NetWaySP3WP, NetWaySP3WPX, NetWaySP3X, and NetWaySP3PL: Before powering unit, set input voltage selection switch to proper Input Voltage position (Fig. 2a, pg. 6).
    Units are factory set for 115VAC.

  2. Secure cabinet to earth ground. Connect AC power from overcurrent protective device circuit breaker (20A @ 115VAC, 60Hz, 16A @ 230VAC, 50/60Hz) to the terminals marked [L, N] on power supply board (Fig. 2, pg. 6). Use 14AWG or larger for all power connections (Battery, DC output, AC input). Connect ground lug to earth or green branch wire (12AWG min.).
    Note: For NetWaySP3WPN use external 48-55V UL Listed ITE power supply, carefully observing correct polarity (Fig. 3, pg. 7). Keep power-limited wiring separate from non power-limited wiring by utilizing separate knockouts/ inlets. Minimum 0.25” spacing must be provided.
    CAUTION: Do not touch exposed metal parts. Shut branch circuit power before installing or servicing equipment. There are no user serviceable parts inside. Refer installation and servicing to qualified service personnel.

  3. Connect structured cables from port marked [Port 1], [Port 2] or [Port 3] on Pettway unit to Poe compliant cameras/edge devices (Fig. 2, pg. 6).
    Note: All interconnected devices must be UL Listed.

  4. Insert SFP module into port marked [SFP], then connect cable to the SFP module on NetWaySP3B to the corresponding input of an SFP switch (Fig. 2, pg. 6).

  5. Battery Backup (if desired): Connect four (4) 12VDC batteries wired in series to terminals marked [+ BAT –] (Fig. 2, pg. 6), carefully observing polarity. When use of stand-by batteries is desired, they must be lead acid or gel type.
    Note: When batteries are not used, a loss of AC will result in the loss of output voltage.

  6. Please ensure that the cover is secured with: Key lock and screws for NetWaySP3X, Security bolt for NetWaySP3WP, NetWaySP3WPN and NetWaySP3WPX.

Recommended Altronix SFP Modules

Altronix P1MM, P1SM10, P1AB2K and P1GCE are hot-pluggable SFP fiber transceiver modules and are readily usable with all Altronix Spectrum fiber optic equipment for 1Gb transmission rates.

  • P1MM – For use with Multi-Mode Fiber for distances up to 550m.
  • P1SM10 – For use with Single-Mode Fiber for distances up to 10km.
  • P1AB2K – For use with Single Strand Single-Mode Fiber for distances up to 2km.
  • P1GCE – For use with CAT5e or better for distances up to 100m.

Technical Specifications:

Parameter Description
Number of Ports Three (3) ports PoE+ (30W) or up to two (2) Hi-PoE (60W)

ports. One (1) Gigabit SFP Port.
Input Power Requirements| 115VAC, 60Hz, 2.5A or 230VAC, 50/60Hz, 1.3A.NetWaySP3B/NetWaySP3WPN: 48-55V UL Listed ITE power supply
Environmental Conditions| Operating Ambient Temperature: NetWaySP3WP/NetWaySP3WPX:60W: – 40ºC to 75ºC (– 40ºF to 167ºF);75W: – 40ºC to 70ºC (– 40ºF to 158ºF);100W: – 40ºC to 55ºC (– 40ºF to 131ºF);120W: – 40ºC to 45ºC (– 40ºF to 113ºF).NetWaySP3X:120W: – 40ºC to 50ºC (– 40ºF to 122ºF).NetWaySP3B/NetWaySP3WPN: 120W: – 40ºC to 75ºC (– 40ºF to 167ºF).
| Relative Humidity: 85%, +/– 5%Storage Temperature: – 40ºC to 85ºC (– 40ºF to 185ºF). Operating Altitude: – 304.8 to 2,000m.
| Model| Product Weight| Shipping Weight
| NetWaySP3WP| 10.32 lbs. (4.68kg)| 11.7 lbs. (5.3kg)
Weights (approx.)| NetWaySP3WPN NetWaySP3WPX NetWaySP3X| 7.7 lbs. (3.49kg)15 lbs. (6.8 kg)65 lbs. (3.02 kg)| 10.0 lbs. (4.54kg)17.5 lbs. (7.9kg)7.55 lbs. (3.42kg)
| NetWaySP3PL| 2.6 lbs. (1.18 kg)| 4.0 lbs. (1.81kg)
| NetWaySP3B| 0.25 lbs. (0.11 kg)| 0.75 lbs. (0.34kg)

Configuring Units for Network Connection

Please be sure to visit altronix.com for latest firmware and installation instructions

Factory Default Settings
  • IP Address: 168.168.168
  • User Name: admin
  • Password: admin
  1. Set the static IP address for the laptop to be used for programming to the same network IP address as the The default address of the NetwaySP3 is 192.168.168.168, E.I. 192.168.168.200.
  2. Connect one end of the network cable to the network jack on the NetwaySP3 and the other to the network connection of the
  3. Open a browser on the computer and enter “192.168.168.168” into the address A dialog box Authentication Required will appear requesting both user name and password. Enter the default values here. Click on the button labeled Log In.
  4. The status page of the NetWaySP3 will Click on the tab labeled Network Settings. This will open the Network Setting screen. In this screen the MAC Address of the NetWaySP3 module will be found along with the Network Settings and Email Settings.
Network Settings:

In the IP Address Method field select the method that the IP Address for the NetWaySP3 will be obtained (STATIC or DHCP), then follow the appropriate steps.

Static:
  1. IP Address: Enter the IP address assigned to the NetWaySP3 by the network
  2. Subnet Mask: Enter the Subnet of the
  3. Gateway: Enter the TCP/IP gateway of the network access point (router) being Gateway configuration is required to properly receive emails from the device.
  4. HTTP Port: Enter the HTTP port number assigned to the NetWaySP3 module by the network administrator to allow remote access and The default inbound port setting is 80. HTTP is not encrypted and unsecure. Even though HTTP can be used for remote access, it is recommended primarily for use with LAN connections.
  5. HTTPS Port: Enter the HTTPS port number assigned to the NetWaySP3 module by the network administrator to allow remote access and The default inbound port setting is 443. Being encrypted and more secure, HTTPS is highly recommended for remote access.
  6. Click the button labeled Submit Network

A dialog box will display “New network settings will take effect after the server is rebooted”. Click OK.

DHCP
  • After selecting DHCP in the IP Address Method field click the button labeled Submit Network Settings. A dialog box will display “New network settings will take effect after the server is rebooted”. Click OK. Next, click on the button labeled Reboot Server. After rebooting the NetWaySP3 will be set in the DHCP mode. The IP address will be assigned by the router when the NetWaySP3 is connected to the network. It is recommended to have the assigned IP Address reserved to ensure continued access (see the network administrator).
  • Subnet Mask: When operating in DHCP, the router will assign the subnet mask values.
  • Gateway: Enter the TCP/IP gateway of the network access point (router) being used.
  • HTTP Port: Enter the HTTP port number assigned to the NetWaySP3 module by the network administrator to allow remote access and monitoring. The default inbound port setting is 80. HTTP is not encrypted and unsecure. Even though HTTP can be used for remote access, it is recommended primarily for use with LAN connections.
Secure Network Setup (HTTPS)

In order to setup HTTPS for a Secure Network Connection, a Valid Certificate and Key must be used. Certificates and Key should be in a “.PEM” format. Self Certifications should only be used for testing purposes as no actual authentication is being performed. In a Self-Certified mode, the connection will still state that it is unsecure. How to upload Certificate and Key to setup HTTPS:

  1. Open Tab Labeled “Security”
  2. Select Tab Labeled “Email/SSL”
  3. Scroll to bottom under “SSL Settings”
  4. Click “Select Certificate”
  5. Browse and select valid Certificate to upload from server
  6. Click “Select Key”
  7. Browse and select valid Key to upload from server
  8. Click “Submit Files”

Once the Certificate and Key is uploaded successfully you can proceed with setting up HTTPS in Network Settings.

  • HTTPS Port: Enter the HTTPS port number assigned to the NetWay4E module by the network administrator to allow remote access and monitoring. The default inbound port setting is 443. Being encrypted and more secure, HTTPS is highly recommended for remote access.
  • Click the button labeled Submit Network Settings.
    A dialog box will display “New network settings will take effect after the server is rebooted”. Click OK.

Factory Reset Option

  1. Power the unit down. Allow approximately 30 seconds for the unit to power down completely.
  2. Depress Factory Reset button on NetWaySP3B while reapplying power to the unit (Fig. 1, pg. 5; Fig. 2b, pg. 6). Continue holding the button until the LEDs on board go through the start up cycle, then release the button.
  3. The unit returns to the original factory settings.

Altronix-NETWAYSP3PL-3-Port-Ethernet-over-Fibe-PoE-plus-Hardened-
Switches-01

Altronix-NETWAYSP3PL-3-Port-Ethernet-over-Fibe-PoE-plus-Hardened-
Switches-17000000Altronix-NETWAYSP3PL-3-Port-Ethernet-over-
Fibe-PoE-plus-Hardened-Switches-180000

Altronix-NETWAYSP3PL-3-Port-Ethernet-over-Fibe-PoE-plus-Hardened-
Switches-05

Wall Mount Installation

  1. Place unit at desired location and secure with mounting screws (not included) (Fig. 4, pg. 10).

Altronix-NETWAYSP3PL-3-Port-Ethernet-over-Fibe-PoE-plus-Hardened-
Switches-06

Pole Mounting Using Optional Pole Mount Kit
PMK1 (NetWaySP3WP and NetWaySP3WPN) or PMK2 (NetWaySP3WPX): This installation should be made by qualified service personnel. This product contains no serviceable parts. PPMK1 and PMK2 outdoor pole mount kits are designed to simplify the installation of Aptronics outdoor rated power supplies
and accessories housed in models WP1, WP2, WP3 and WP4 NEMA rated enclosures. PMK1 and PMK2 can be
mounted on 2” to 8” (50.8mm to 203.2mm) diameter round or 5” (127mm) square poles. Brackets are designed for use with the Wormer Quick Release Straps (two included).

  1. Thread one (1) wormer quick release strap through the slots on the back of a mounting bracket (Fig. 5, pg. 10).
  2. Once the desired height of the top Pole Mount bracket is achieved, tighten the straps down by sliding open end of the strap through the locking mechanism on the strap, then tighten the screw with flat head screwdriver or 5/16” hex socket driver (Fig. 5, pg. 10 and Fig. 8, pg. 10).
  3. Altronix-NETWAYSP3PL-3-Port-Ethernet-over-Fibe-PoE-plus-Hardened-Switches-07Attach the bottom bracket to the enclosure by inserting bolts through the flange of the enclosure and into the bracket, tightening bolts with a 7/16” hex socket (Fig. 9, pg. 10).
  4. Thread the second wormer quick release strap through the slots on the back of the bottom mounting bracket (Fig. 7, pg. 10).
  5. Mount enclosure onto the top bracket by inserting bolts through flange of the enclosure and into the bracket, tightening bolts with a 7/16” hex socket (Fig. 9, pg. 10).
  6. Tighten the straps of the bottom bracket down by sliding the open end of the strap through the locking mechanism on the strap, then tighten screw with flat head screwdriver or 5/16” hex socket driver (Fig. 8, pg. 10).
  7. Clip excess straps.

Altronix-NETWAYSP3PL-3-Port-Ethernet-over-Fibe-PoE-plus-Hardened-
Switches-08

NetWaySP3X

Mechanical Drawing and Dimensions (H x W x D approx.)

Altronix-NETWAYSP3PL-3-Port-Ethernet-over-Fibe-PoE-plus-Hardened-
Switches-09

Altronix-NETWAYSP3PL-3-Port-Ethernet-over-Fibe-PoE-plus-Hardened-
Switches-10

Altronix-NETWAYSP3PL-3-Port-Ethernet-over-Fibe-PoE-plus-Hardened-
Switches-11

NetWaySP3WP and NetWaySP3WPN

Mechanical Drawing and Dimensions (H x W x D approx.)

Altronix-NETWAYSP3PL-3-Port-Ethernet-over-Fibe-PoE-plus-Hardened-
Switches-13

Altronix-NETWAYSP3PL-3-Port-Ethernet-over-Fibe-PoE-plus-Hardened-
Switches-14

NetWaySP3WPX

Mechanical Drawing and Dimensions (H x W x D approx.)

Altronix-NETWAYSP3PL-3-Port-Ethernet-over-Fibe-PoE-plus-Hardened-
Switches-16

Documents / Resources

| Altronix NETWAYSP3PL 3-Port Ethernet over Fiber PoE plus Hardened Switches [pdf] Instruction Manual
NETWAYSP3PL, 3-Port Ethernet over Fiber PoE plus Hardened Switches, NETWAYSP3PL 3-Port Ethernet over Fiber PoE plus Hardened Switches, Fiber PoE plus Hardened Switches, Hardened Switches, Switches
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Altronix User Manuals

Related Manuals