Prodis HC202R Under Counter White Storage Fridge User Manual
- June 9, 2024
- Prodis
Table of Contents
Prodis HC202R Under Counter White Storage Fridge
- PROPER INSTALLATION, USE AND MAINTENANCE OF THIS MACHINE ARE ALL IMPORTANT FOR MAINTAINING EFFICIENCY AND USER SAFETY. IN ORDER TO REDUCE THE FAILURE RATE PLEASE READ THESE INSTRUCTIONS CAREFULLY. IMPROPER USE COULD RESULT IN EQUIPMENT DAMAGE, PERSONAL INJURY OR EVEN DEATH.
- DO NOT LET CHILDREN PLAY WITH THE CABINET OR ITS PACKAGING MATERIALS.
- AT LEAST TWO PEOPLE ARE REQUIRED TO POSITION AND UNPACK THE CABINET OR IT IS RECOMMENDED THAT A LIFTING DEVICE IS USED TO AVOID INJURY.
- A QUALIFIED ENGINEER MUST PERFORM THE INSTALLATION AND ONGOING MAINTENANCE OF THE REFRIGERATOR.
- WHEN OPERATING ALL PROCEDURES MUST BE FOLLOWED IN ACCORDANCE WITH THESE INSTRUCTIONS TO ENSURE NO DAMAGE OCCURS TO THE REFRIGERATION SYSTEM.
- DO NOT OPERATE THE UNIT IF THERE ARE UNAUTHORISED CHANGES TO THE ORIGINAL MANUFACTURES SPECIFICATIONS OR IF THE MACHINE HAS BEEN MISUSED, ABUSED OR NEGLECTED.
- DO NOT COVER THE FRONT VENTS, THERE MUST BE A MINIMUM CLEARANCE OF 200MM ON ALL SIDES OF THE REFRIGERATOR AT ALL TIMES DURING OPERATION.
- DO NOT STORE FLAMMABLE GASES OR LIQUIDS IN OR NEAR TO THE REFRIGERATOR.
- DO NOT USE HIGH-PRESSURE WATER CLEANING DEVICES TO CLEAN THE REFRIGERATOR.
- IT IS THE USERS RESPONSIBILITY TO TAKE APPROPRIATE MEASURES TO ENSURE THE SAFETY OF STAFF OPERATING REFRIGERATOR.
- IT IS THE USERS RESPONSIBILITY TO ENSURE THE ONGOING MAINTENANCE OF THE REFRIGERATOR IS COMPLETED IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS LAID OUT IN THIS MANUAL.
- TO PREVENT ACCIDENTAL INJURIES KEEP THE AREA SURROUNDING THE REFRIGERATOR CLEAN AND TIDY AND FREE FROM OBSTRUCTIONS.
- ALWAYS USE A DEDICATED ELECTRICAL OUTLET FOR INSTALLATION. DO NOT USE EXTENSION CABLES OR MULTI-PLUG ADAPTORS AS THIS COULD CAUSE ELECTRICAL SHOCK, OVERHEATING OR FIRE.
- NEVER OPERATE THE REFRIGERATOR WITH A DAMAGED POWER CABLE AS THIS COULD CAUSE ELECTRICAL SHOCK, OVERHEATING OR FIRE.
- NEVER TWIST, BUNDLE, STRAIN OR EXCESSIVELY BEND THE POWER CABLE AS THIS COULD CAUSE ELECTRICAL SHOCK, OVERHEATING OR FIRE.
- THIS UNIT IS DESIGNED FOR USE INDOORS ONLY, USING THE CABINET OUTSIDE OR IN AN AREA SUBJECT TO MOISTURE COULD CAUSE DAMAGE, ELECTRICAL SHOCK, OVERHEATING OR FIRE.
- THIS UNIT MUST BE INSTALLED ON A LEVEL FLOOR WHICH IS CAPABLE OF SUPPORTING THE WEIGHT OF THE UNIT WHEN FULLY LOADED. INSTALLATION ON AN UNEVEN SURFACE COULD CAUSE DAMAGE, INJURY AND BREAKDOWNS.
- NEVER INSERT FINGERS OR OBJECTS INTO THE FANS AS THEY ROTATE AT HIGH SPEED.
- NEVER PLACE HEAVY OBJECTS OR ITEMS CONTAINING WATER ON TOP OF THE UNIT AS THIS COULD CAUSE INJURY, OR DAMAGE TO THE CABINET.
- THIS REFRIGERATOR MUST BE INSTALLED AWAY FROM HEAT SOURCES AND OUT OF DIRECT SUNLIGHT. INSTALLATION IN A HOT ENVIRONMENT OR IN DIRECT SUNLIGHT COULD CAUSE BREAK DOWNS AND WILL ADVERSELY AFFECT COOLING EFFICIENCY AND PERFORMANCE.
- ALWAYS TRANSPORT THIS COOLER IN AN UPRIGHT POSITION AND NEVER TILT THE UNIT AT MORE THAN A 45° ANGLE FROM VERTICAL.
IMPORTANT
- THIS MANUAL IS AN INTEGRAL PART OF THE REFRIGERATOR AND SHOULD BE KEPT AND PRESERVED BY THE USER FOR FUTURE REFERENCE. PLEASE READ THE INSTRUCTIONS CAREFULLY FOR THE CORRECT INSTALLATION METHOD, SAFETY WARNINGS AND MAINTENANCE INFORMATION FOR THIS REFRIGERATOR.
- THIS REFRIGERATOR IS DESIGNED FOR COMMERCIAL USE AND SHOULD BE USED FOR THE PURPOSE FOR WHICH IT HAS BEEN EXPRESSLY DESIGNED. ANY OTHER USE SHOULD BE CONSIDERED IMPROPER AND THEREFORE DANGEROUS. THE MANUFACTURER WILL NOT BE LIABLE OR RESPONSIBLE FOR ANY DAMAGE CAUSED BY IMPROPER, INCORRECT OR UNREASONABLE USE.
INSTALLATION
WARNING
THE INSTALLATION OF THIS REFRIGERATOR MUST BE CARRIED OUT BY QUALIFIED
PERSONNEL IN ACCORDANCE WITH CURRENT REGULATIONS AND AS PER THE MANUFACTURERS
INSTRUCTIONS. FAILURE TO CORRECTLY INSTALL THIS REFRIGERATOR COULD RESULT IN
DAMAGE OR INJURY AND WILL VOID THE WARRANTY.
01. UNPACKING
WARNING
KEEP ALL PACKAGING MATERIALS INCLUDING BOXES, PLASTIC BAGS AND POLYTHENE OUT
OF REACH OF CHILDREN
IMPORTANT
- i. REMOVE ALL SHIPPING MATERIALS, TAPE AND PACKAGING FROM THE BOTH OUTSIDE AND INSIDE THE REFRIGERATOR. IF PACKAGING MATERIAL IS LEFT INSIDE THE REFRIGERATOR IT WILL NOT FUNCTION CORRECTLY
- ii. AFTER REMOVING THE PACKAGING MAKE SURE THE REFRIGERATOR IS IN GOOD CONDITION. IF IN DOUBT PLEASE DO NOT INSTALL OR USE THE REFRIGERATOR AND CONTACT YOUR SUPPLIER IMMEDIATELY.
- iii. REMOVE THE SHIPPING TAPE WHICH IS HOLDING THE DOOR CLOSED.
- iv. REMOVE THE PROTECTIVE PLASTIC FILM (IF PRESENT) FROM THE EXTERIOR BEFORE INSTALLATION. IF THE REFRIGERATOR HAS BEEN EXPOSED TO SUN OR HEAT ALLOW THE REFRIGERATOR TO COOL DOWN BEFORE REMOVING THE PROTECTIVE FILM.
- iv. REMOVE THE ACCESSORY PACK AND CHECK THE CONTENTS, IT SHOULD CONTAIN
- 1 x SET OF KEYS (IF LOCK FITTED)
- 1 x INSTRUCTION MANUAL
- 1 x DIGITAL CONTROLLER MANUAL
LOCATION
WARNING
THIS REFRIGERATOR IS NOT INTENDED FOR OUTDOOR USE. NORMAL OPERATING
TEMPERATURES FOR THIS REFRIGERATOR ARE BETWEEN 10°C AND 32°C. USE OF THIS
REFRIGERATOR OUTSIDE OF THE DEFINED OPERATING PARAMETERS WILL AFFECT COOLING
AND MAY DAMAGE THE UNIT.
- ENSURE THERE IS A FREE FLOW OF CLEAN AIR AVAILABLE AT THE FRONT AND REAR OF THE REFRIGERATOR.
- THIS REFRIGERATOR SHOULD NOT BE INSTALLED CLOSE TO A HEAT SOURCE (RADIATOR, STOVE OR HEATER) OR EXPOSED TO DIRECT SUNLIGHT.
- THEINSTALLATIONLOCATIONSHOULD BE FIRM AND LEVEL AND ABLE TO SUPPORT THE FULL WEIGHT OF THE REFRIGERATOR WHEN FULLY LOADED.
- ALLOW AT LEAST 200MM CLEARANCE AT THE ALL SIDES OF THE UNIT FOR PROPER AIR CIRCULATION AND EASE OF MAINTENANCE.
- THIS REFRIGERATOR IS NOT SUITABLE FORINSTALLATION IN AREAS WHERE WATER IS FREEFLOWING OR HIGH PRESSURE WATER JETS AREUSED.
WARNING
ALWAYS TRANSPORT YOUR REFRIGERATOR IN AN UPRIGHT POSITION AND NEVER TILT PAST
A 45° ANGLE.
LEVELLING THE REFRIGERATOR
- CARE SHOULD BE TAKEN TO ENSURE THE REFRIGERATOR IS PERFECTLY LEVEL FOR CORRECT OPERATION. A SPIRIT LEVEL SHOULD BE USED TO CHECK THE UNIT IS PERFECTLY LEVEL, IF THE UNIT IS NOT LEVEL WATER LEAKS MAY OCCUR.
ELECTRICAL CONNECTION
WARNING
ALL WIRING AND ELECTRICAL CONNECTION MUST CONFIRM TO NATIONAL REGULATIONS. ALL
ELECTRICAL CONNECTIONS MUST BE UNDERTAKEN BY A COMPETENT ENGINEER OR A
QUALIFIED ELECTRICIAN.
- THIS REFRIGERATOR MUST BE PLUGGED IN TO AN INDEPENDENT POWER SOURCE OR AN ELECTRICAL SOCKET OF VOLTAGE AND FREQUENCY SPECIFIED. ELECTRICAL RATING INFORMATION CAN BE FOUND ON THE DATA PLATE OF THE REFRIGERATOR.
- THIS REFRIGERATOR MUST BE CONNECTED TO AN INDEPENDENT CIRCUIT BREAKER OR FUSE.
- DUE TO POTENTIAL SAFETY HAZARDS THIS REFRIGERATOR IS NOT RECOMMENDED FOR USE WITH AN EXTENSION LEAD
WARNING
IF THE POWER SUPPLY CABLE IS DAMAGED, DO NOT INSTALL OR OPERATE THE MACHINE UNTIL THE CABLE HAS BEEN REPLACED BY AN AUTHORISED SERVICE PARTNER OR A QUALIFIED ENGINEER.
WARNING
ALL ELECTRICAL CONNECTIONS MUST CONFORM TO LOCAL REGULATIONS AND BE CARRIED OUT BY A QUALIFIED ENGINEER
PRE-INSTALLATION CHECK LIST
ALL REFRIGERATORS HAVE BEEN FACTORY PRESET BEFORE SHIPMENT. ADJUSTMENTS TO THE PROGRAM OR SETTINGS ARE NOT REQUIRED FOR A NEW REFRIGERATOR INSTALLATION. IN ORDER TO ENSURE NORMAL OPERATION OF THE REFRIGERATOR PLEASE REFER TO PART III OF THIS MANUAL. ALWAYS REMEMBER THAT CHECKING AND MONITORING OF THE REFRIGERATOR IS THE RESPONSIBILITY OF THE OPERATOR.
- IS THE REFRIGERATOR INSTALLED ON A SOLID AND LEVEL FLOOR
- HAS ALL OF THE INNER AND OUTER PACKAGING BEEN REMOVED FROM THE UNIT?
- IS THERE PROPER VENTILATION AT THE FRONT AND REAR OF THE REFRIGERATOR?
- HAS THE REFRIGERATOR BEEN CLEANED INSIDE AND OUT?
- IS THE REFRIGERATOR CORRECTLY EARTHED?
- IS THE POWER TO THE MACHINE SWITCHED ON?
- IS THE REFRIGERATOR LOCATED IN A ROOM WITH AN AMBIENT TEMPERATURE BETWEEN 10°C AND 32°C?
- HAVE ALL USERS BEEN FULLY TRAINED IN THE OPERATION OF THE REFRIGERATOR?
- HAS THE REFRIGERATOR BEEN ALLOWED TO STAND FOR A MINIMUM OF 2 HOURS?
OPERATING INSTRUCTIONS
WARNING
AFTER TURNING OFF YOUR REFRIGERATOR YOU MUST WAIT AT LEAST 5 MINUTES BEFORE RESTARTING TO AVOID DAMAGE TO THE COMPRESSOR
ALTERING THE TEMPERATURE
YOUR COOLER FEATURES A DIGITAL CONTROLLER. ALL PARAMETERS ARE PRESET AT THE
FACTORY FOR OPTIMUM COOLING PERFORMANCE AND EFFICIENCY. ALTERING THE
PARAMETERS OF THE DIGITAL CONTROLLER WILL ADVERSELY AFFECT THE COOLING
EFFICIENCY AND PERFORMANCE OF THE COOLER.
TO CHANGE THE SET POINT OF YOUR COOLER PRESS AND HOLD THE SET BUTTON FOR 2
SECONDS, THE DISPLAY WILL FLASH AND THE CURRENT SET TEMPERATURE WILL BE
DISPLAYED. USE THE UP AND DOWN ARROWS TO ADJUST THE TEMPERATURE ACCORDING TO
YOUR NEEDS AND PRESS THE SET BUTTON AGAIN TO STORE THE NEW SET POINT.
CHANGING THE SET POINT WILL AFFECT THE PERFORMANCE AND EFFICIENCY OF THE
COOLER AND SHOULD ONLY BE UNDERTAKEN BY A QUALIFIED REFRIGERATION ENGINEER.
ADJUSTING THE SHELVES
YOUR REFRGERATOR IS FITTED WITH ADJUSTABLE SHELVES WHICH CAN BE MOVED TO SUIT
DIFFERENT SIZE PRODUCTS. TO ADJUST THE SHELVES REMOVE THE SHELF COMPLETELY
FROM THE UNIT AND REINSTALL IN THE NEW POSITION.
DEFROSTING REFRIGERATORS
YOUR REFRIGERATOR IS FITTED WITH AN AUTOMATIC OFF CYCLE DEFROST SYSTEM.
MANUALLY DEFROSTING IS NOT REQUIRED UNDER NORMAL CIRCUMSTANCES.
IN HUMID CONDITIONS MOISTURE IN THE AIR MAY CAUSE AN EXCESS BUILD UP ON FROST
ON THE INSIDE OF THE UNIT.
TO DEFROST YOUR COOLER UNLOAD THE CABINET AND TURN OFF UNTIL ALL FROST AND ICE
BUILD UP HAS NATURALLY MELTED. A TOWEL MAY NEED TO BE PLACED UNDER THE CABINET
TO SOAK UP ANY EXCESS MOISTURE GENERATED DURING DEFROST. IF FROST BUILD UP
REOCCURS AND THE CABINET IS WITHIN ITS NORMAL AMBIENT OPERATING TEMPERATURE
THE THERMOSTAT MAY BE SET TOO LOW, ADJUST THE SET POINT TO THE FACTORY DEFAULT
SETTING OF 2°c.
DEFROSTING FREEZERS
YOUR FREEZER WILL NEED TO BE DEFROSTED PERIODICALLY DEPENDING ON USAGE,
AMBIENT OPERATING TEMPERATURES AND FREQUENCY OF OPENING.
TO DEFROST YOU UNIT FIRST UNLOAD THE FREEZER OF ALL PRODUCE.
TURN OFF THE POWER TO THE UNIT AND OPEN THE DOOR.
A TOWEL MAY NEED TO BE PLACED UNDER THE CABINET TO SOAK UP ANY EXCESS MOISTURE
GENERATED DURING DEFROST.
NEVER SCRAPE FROST AND ICE OFF THE INTERIOR OF THE FREEZER WITH A SHARP
IMPLEMENT OR TOOL AS THIS COULD CAUSE DAMAGE TO THE INTERIOR OF THE CABINET
AND REFRIGERATION SYSTEM.
LOADING YOUR CABINET
ALLOW YOUR CABINET TO RUN FOR 2 HOURS AFTER INSTALLATION BEFORE LOADING
PRODUCTS INTO THE REFRIGERATOR.
ALWAYS LOAD YOUR REFRIGERATOR IN BATCHES, FULLY LOADING YOUR CABINET WITH WARM
PRODUCT WILL INCREASE THE CABINET TEMPERATURE AND MAY CAUSE LOSS OF PRODUCT.
WHEN LOADING YOUR REFRIGERATOR ALWAYS ALLOW ADEQUATE SPACE FOR FLOW OF AIR
INSIDE THE CABINET. NEVER LOAD PRODUCTS TOUCHING THE INTERIOR WALLS OF THE
UNIT. NEVER LOAD PRODUCTS SO THAT THEY ARE OVERHANGING THE SHELVES. THE SPACE
BETWEEN THE FRONT OF THE SHELF AND THE DOOR IS DESIGNED TO ASSIST AIR FLOW,
NEVER BLOCK THIS SPACE.
ALWAYS LOAD YOUR REFRIGERATOR WITH CARE, NEVER THROW OR DROP ITEMS ON TO THE
SHELVES AS THIS COULD CAUSE DAMAGE TO THE INSIDE OF THE CABINET OR DISLOCATE
THE SHELF CAUSING DAMAGE OR INJURY.
EFFICIENT USE
TO PREVENT COLD AIR FROM ESCAPING OPEN AND CLOSE THE DOOR QUICKLY.
ALWAYS LOAD YOUR CABINET TO ALLOW FOR SUFFICIENT AIRFLOW BETWEEN PRODUCTS.
ALWAYS TRY TO KEEP YOUR CABINET AS FULLY LOADED WITH COLD PRODUCE AS POSSIBLE.
INSTALL THE UNIT IS A WELL VENTILATED AREA WHERE THE AMBIENT TEMPERATURE WILL
NOT RISE ABOVE 30°C.
THE CABINET IS SUITABLE FOR USE IN CONDITIONS UP TO 55% RELATIVE HUMIDITY.
CONDITIONS ABOVE THE RATED VALUE WILL CAUSE EXCESS FROST AND ICE BUILD UP
WHICH WILL AFFECT THE PERFORMANCE AND EFFICIENCY OR THE REFRIGERATION SYSTEM
DEFROST YOUR CABINET REGULARLY TO KEEP ICE BUILD UP AND FROST TO A MINIMUM TO
INCREASE EFFICIENCY
EXTERIOR CLEANING
ALWAYS CLEAN THE EXTERIOR OF THE REFRIGERATOR WITH A MICRO-FIBRE CLOTH AND OR
A SPONGE.
DO NOT USE ABRASIVE OR METALLIC PRODUCTS (WIRE WOOL) WHICH COULD SCRATCH AND
DAMAGE THE FINISH OF THE REFRIGERATOR PERMANENTLY.
INTERIOR CLEANING
CLEAN THE INTERIOR OF THE REFRIGERATOR AND ALL REMOVABLE PARTS BY WASHING THEM
WITH A SOLUTION OF LUKEWARM WATER AND A SMALL AMOUNT OF DISH-WASHING LIQUID.
RINSE AND DRY IMMEDIATELY.
WARNING
ALTHOUGH THE REFRIGERATOR HAS BEEN TESTED AND CLEANED AT THE FACTORY DIRT
AND PARTICLES MAY OF ENTERED THE CABINET DURING TRANSIT, UNPACKING AND
INSTALLATION. DUE TO THIS IT IS IMPORTANT THAT YOUR REFRIGERATOR IS CLEANED
INSIDE AND OUT BEFORE OPERATION.
WARNING
NEVER CLEAN THE REFRIGERATOR WITH A PRESSURE WASHER OR BY SPRAYING WATER.
WARNING
NEVER USE ACIDIC OR ABRASIVE DETERGENTS, THESE TYPES OF CLEANERS MAY DAMAGE
THE INTERIOR AND EXTERIOR OF THE REFRIGERATOR AND MAY LEAD TO DISCOLOURATION.
WARNING
DISCONNECT THE MACHINE FROM THE MAINS ELECTRICITY BEFORE PERFORMING ANY
CLEANING OR MAINTENANCE.
CONDENSER CLEANING
A DIRTY OR CLOGGED CONDENSER WILL PREVENT PROPER AIR FLOW. THIS WILL LEAD TO
REDUCED EFFICIENCY AND AN INCREASE IN OPERATING TEMPERATURE WHICH MAY LEAD TO
COMPONENT FAILURE. WE RECOMMEND THE CONDENSER IS CLEANED EVERY SIX MONTHS BY A
QUALIFIED ENGINEER. TO CLEAN THE CONDENSER DISCONNECT THE REFRIGERATOR FROM
THE MAINS ELECTRICITY.REMOVE THE SCREWS FROM THE REAR BOTTOM PANEL AND GENTLY
REMOVE THE GRILL.
REMOVE DIRT AND DUST FROM THE CONDENSER FINS WITH A SOFT BRUSH AND VACUUM
CLEANER. REATTACH THE GRILL AND RECONNECT POWER TO THE MACHINE.
WARNING
CONDENSER CLEANING SHOULD ONLY BE UNDERTAKEN BY A QUALIFIED ENGINEER OR
SERVICE PARTNER.
WARNING
FAILURE TO CLEAN YOUR CONDENSER COULD CAUSE COMPONENT FAILURE AND WILL
INVALIDATE YOUR WARRANTY.
PREPARING YOUR REFRIGERATOR FOR LONG TERM STORAGE OR MOVING
IF THE REFRIGERATOR NEEDS TO BE STORED FOR A LONG PERIOD OF TIME OR IT NEEDS
TO BE MOVED TO A NEW LOCATION THE FOLLOWING STEPS MUST BE TAKEN
DISCONNECT THE UNIT FROM THE MAINS ELECTRICITY.
REMOVE ALL REMAINING PRODUCT FROM THE CABINET.
CLEAN THE INSIDE OF THE REFRIGERATOR AND THOROUGHLY DRY THE INSIDE WITH PAPER
TOWELS.
FOR TRANSPORTING TO A NEW LOCATION TAPE THE DOOR SHUT WITH A LOW TACK TAPE
(MASKING TAPE) OR LOCK THE DOORS (WHERE LOCKS ARE FITTED)
FOR LONG TERM STORAGE LEAVE THE DOOR OPEN AT LEAST 50MM TO ALLOW FOR AIR FLOW
INTO THE REFRIGERATOR. THIS WILL PREVENT MOLD AND MILDEW FORMING.
NEVER STORE THE REFRIGERATOR IN AN AREA WHERE CHILDREN COULD CLIMB INSIDE AND
BECOME TRAPPED.
ALWAYS TRANSPORT YOUR CABINET IN AN UPRIGHT POSITION AND NEVER TILT PAST A 45°
ANGLE.
WARNING
AFTER LONG TERM STORAGE OR TRANSPORT YOU NEED TO FOLLOW ALL INSTRUCTIONS IN
PART II OF THIS INSTRUCTION MANUAL WHEN REINSTALLING THE MACHINE.
WARNING
ALWAYS TRANSPORT YOUR REFRIGERATOR IN AN UPRIGHT POSITION AND NEVER TILT PAST
A 45° ANGLE.
SPECIFICATION
MODEL
| ****
HC202R
| ****
HC202RSS
| ****
HC202F
| ****
HC202FSS
| ****
HC401R
| ****
HC401RSS
---|---|---|---|---|---|---
CABINET TEMPERATURE| ****
2°c to 10°c
| ****
2°c to 10°c
| ****
-18°c to -22°c
| ****
-18°c to -22°c
| ****
2°c to 8°c
| ****
2°c to 8°c
CLIMATE CLASS
| ****
4
| ****
4
| ****
4
| ****
4
| ****
4
| ****
4
FINISH
| ****
WHITE
| ****
STAINLESS STEEL
| ****
WHITE
| ****
STAINLESS STEEL
| ****
WHITE
| ****
STAINLESS STEEL
SHELVES
| ****
2
| ****
2
| ****
2
| ****
2
| ****
4
| ****
4
DEFROST SYSTEM| ****
OFF CYCLE
| ****
OFF CYCLE
| ****
MANUAL
| ****
MANUAL
| ****
OFF CYCLE
| ****
OFF CYCLE
CONTROLLER
| ****
XR02CX
| ****
XR02CX
| ****
XR02CX
| ****
XR02CX
| ****
XR02CX
| ****
XR02CX
DIMENSIONS
(w,d,h mm)
| ****
600 x 620 x 850
| ****
600 x 620 x 850
| ****
600 x 620 x 850
| ****
600 x 620 x 850
| ****
600 x 646 x 1875
| ****
600 x 646 x 1875
ENERGY EFFICIENCY| ****
C
| ****
C
| ****
N/A
| ****
N/A
| ****
D
| ****
D
VOLTAGE
| ****
230V/50Hz
| ****
230V/50Hz
| ****
230V/50Hz
| ****
230V/50Hz
| ****
230V/50Hz
| ****
230V/50Hz
MODEL
| ****
HC401F
| ****
HC401FSS
| ****
HC601R
| ****
HC601RSS
| ****
HC601F
| ****
HC601FSS
---|---|---|---|---|---|---
CABINET TEMPERATURE| ****
-10°c to -25°c
| ****
-10°c to -25°c
| ****
0°c to 8°c
| ****
0°c to 8°c
| ****
-10°c to -25°c
| ****
-10°c to -25°c
CLIMATE CLASS
| ****
4
| ****
4
| ****
4
| ****
4
| ****
4
| ****
4
FINISH
| ****
WHITE
| ****
STAINLESS STEEL
| ****
WHITE
| ****
STAINLESS STEEL
| ****
WHITE
| ****
STAINLESS STEEL
SHELVES
| ****
6
| ****
6
| ****
4
| ****
4
| ****
6
| ****
6
DEFROST SYSTEM| ****
MANUAL
| ****
MANUAL
| ****
OFF CYCLE
| ****
OFF CYCLE
| ****
MANUAL
| ****
MANUAL
CONTROLLER
| ****
XR02CX
| ****
XR02CX
| ****
XR02CX
| ****
XR02CX
| ****
XR02CX
| ****
XR02CX
DIMENSIONS
| ****
600 x 646 x 1875
| ****
600 x 646 x 1875
| ****
780 x 720 x 1895
| ****
780 x 720 x 1895
| ****
780 x 720 x 1895
| ****
780 x 720 x 1895
ENERGY EFFICIENCY| ****
N/A
| ****
N/A
| ****
D
| ****
D
| ****
N/A
| ****
N/A
VOLTAGE
| ****
230V/50Hz
| ****
230V/50Hz
| ****
230V/50Hz
| ****
230V/50Hz
| ****
230V/50Hz
| ****
230V/50Hz
TROUBLESHOOTING
SYMPTOM | POSSIBLE CAUSE | SUGGESTED SOLUTION |
---|
UNIT WILL NOT SWITCH ON
| UNIT IS NOT CONNECTED TO MAINS ELECTRICITY CORRECTLY| ****
• CHECK POWER IS ON AT THE SOCKET
• CHECK CABLE IS CORRECTLY PLUGGED IN
MACHINE IS SWITCHED OFF| • PRESS POWER ON/OFF BUTTON (WHERE FITTED)
FUSE BLOWN OR CIRCUIT BREAKER TRIPPED| • CHECK FUSE IN MAIN 13AMP PLUG
• CHECK FUSE OR CIRCUIT BREAKER AT MAIN DISTRIBUTION BOARD
POWER CABLE IS DAMAGED| • CHECK FOR DAMAGE ON POWER CABLE, USE A QUALIFIED
ENGINEER TO REPLACE IF NECESSARY
LOOSE CONNECTION OR FAULTY CONTROLLER| • CHECK FOR LOOSE CONNECTION,
REPLACE IF NECESSARY
COMPRESSOR IS RUNNING BUT REFRIGERATOR IS NOT COOLING
| REFRIGERANT LEAK| • CHECK FOR REFRIGERANT LEAK AND REPAIR, RECHARGE
SYSTEM AS PER THE DATA PLATE
SET POINT TOO HIGH| • CHECK SET POINT OF THE CABINET, CHANGE IF NECESSARY
BLOCKAGE IN SYSTEM| • CLEAR BLOCKAGE, REPLACE FILTER DRIER AND RECHARGE
SYSTEM AS PER THE DATA PLATE
COMPRESSOR WIRING LOOSE OR DEFECTIVE| • CHECK FOR LOOSE CONNECTION, REPLACE
IF NECESSARY
LOOSE CONNECTION OR FAULTY CONTROLLER| • CHECK FOR LOOSE CONNECTION,
REPLACE IF NECESSARY
REFRIGERATOR IS NOISY
| UNIT IS NOT PROPERLY LEVEL| • ENSURE UNIT IS INSTALLED ON A LEVEL AND
SUITABLE FLOOR
CABINET IS TOUCHING ANOTHER CABINET OR A WALL| • CHECK CORRECT VENTILATION
GAP HAS BEEN ADHERED TO – 200MM AT THE REAR
OBJECT IS FOULING EVAPORATOR FAN| • CHECK FOR CORRECT LOADING OF PRODUCT
AND ENSURE NOTHING IS IN CONTACT WITH THE EVAPORATOR FAN OR FAN GUARD
REFRIGERATOR IS NOT GETTING COLD ENOUGH
| CONDENSER DIRTY| • CLEAN CONDENSER AS NECESSARY
INADEQUATE AIR FLOW AROUND REFRIGERATOR| • CHECK CORRECT VENTILATION GAP
HAS BEEN ADHERED TO – 200MM AT THE REAR
CONDENSER FAN NOT WORKING| • CHECK FOR LOOSE CONNECTION, REPLACE IF
NECESSARY
EVAPORATOR FAN NOT WORKING| • CHECK FOR LOOSE CONNECTION, REPLACE IF
NECESSARY
HIGH AMBIENT TEMPERATURE| • WAIT UNTIL AMBIENT TEMPERATURE DROPS BELOW 30°C
FROST IS FORMING INSIDE THE UNIT
| HUMIDITY ABOVE 55%| • LOWER HUMIDITY OF THE ENVIRONMENT
DOOR OPENED TOO OFTEN| • KEEP DOOR OPENINGS TO A MINIMUM
DOOR HAS BEEN LEFT OPEN| • INITIATE MANUAL DEFROST AS LAID OUT IN THIS
MANUAL
DOOR GASKET NOT SEALING CORRECTLY| • CHECK FOR DAMAGE/CRACKS, REPLACE IF
NECESSARY
DEFROST NOT COMPLETING CORRECTLY| • CHECK CONTROLLER PARAMETERS FOR
DEFROST, ADJUST IF NECESSARY (WHERE AVAILABLE)
WATER IS LEAKING FROM THE UNIT
| CABINET IS NOT LEVEL| • CHECK CABINET WITH SPIRIT LEVEL, ADJUST FEET AS
NECESSARY
DEFROST WATER DRAIN HOLE IS BLOCK| • CLEAR DRAIN HOLE AT THE REAR OF THE
CABINET WITH A PIPE CLEANER OR SIMILAR IMPLEMENT
WARNING
ALL MAINTENANCE AND SERVICE WORK MUST BE UNDERTAKEN BY A QUALIFIED REFRIGERATION ENGINEER OR AN AUTHORISED SERVICE PARTNER.
PROJECT DISTRIBUTION LTD
UNIT 1 SUN STREET
STOKE-ON-TRENT
UNITED KINGDOM
ST1 4JW
TEL: 01782 280289
SALES@PROJECT-DISTRIBUTION.CO.UK
WWW.PRODIS.CO.UK
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>