Securevision T15EM Card-PIN Reader User Guide
- June 8, 2024
- Securevision
Table of Contents
- Securevision T15EM Card-PIN Reader
- Packing List
- Quick Reference Programming Guide
- Description
- Features
- Specifications
- Installation
- Wiring
- To Reset to Factory Default
- Sound and Light indication
- Detailed Programming Guide
- (Factory default settings)
- The unit operates as a Wiegand Output Reader
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Securevision T15EM Card-PIN Reader
Packing List
Name | Quantity | Remarks |
---|---|---|
Keypad | 1 | |
User manual | ||
Screw driver | ct>20mmx6Qmm , special for keypad | |
Rubber plug | cD6mmx3 Qmm,usedfor fixing | |
Self tapping screws | ¢>4mm x28mm ,used for fixing | |
Star screws | ¢>3mm x6m m,used for fixing |
Please ensure that all the above contents are correct.lf any are missing please notify the supplier of the unit.
Quick Reference Programming Guide
To enter the programming mode
|
- Master code #
999999 is the default factory master code
---|---
To exit from the programming mode|
Note that to undertake the following programming the master user must be
logged in
To change the master code
|
O New code # New code #
The master code can be 6 to 8 digits
To add a PIN user
|
1 User ID number # PIN #
The ID number is any number between 1 & 2000. The PIN is any four digits between 0000 & 9999 with the exception of 1234 which is reserved. Users can be added oontinuously without exiting programming mode
To add a card user
|
1 Read Card #
Cards can be added continuously without exiting programming mode
To delete a PIN or a card user
|
2 User ID number # for a PIN user or
2 Read Card # for a card user
Users can be deleted continuously without exiting programming mode
Description
The unit is single door multifunction standalone access controller or a Wiegand output touch keypad or card reader. It is suitable for mounting either indoors or outdoors in harsh environments. This unit supports up to 2000 users in either a Card, 4 digit PIN, or a Card + PIN option. The inbuilt card reader supports 125KHZ EM cards, and 13.56MHz Mifare cards. The unit has many extra features including lock output current short circuit protection, Wiegand output These features make the unit an ideal choice for door access not only for small shops and domestic households but also for commercial and industrial applications such as factories, warehouses, laboratories, banks and prisons.
Features
- Indoor use
- Full programming from the keypad
- 2000 users, supports Card, PIN, Card+ PIN
- Can be used as a stand-alone keypad
- Wiegand 26 input for connection to an external reader, Wiegand 26 output for connection to a controller
- Adjustable Door Output time, Alarm time, Door Open time
- Very low power consumption (30mA)
- Fast operating speed, <20ms with 2000 users
- Lock output current short circuit protection
- Easy to install and program
- Built-in buzzer
- Red, Yellow and Green LEDS display the working status
Specifications
Operating Voltage | DC12-24V |
---|---|
User Capacity | 2000 |
Card Reading Distance | 3-6 cm |
Active Current | < 60mA |
Idle Current | 25±5 mA |
Lock Output Load | Max3A |
Operating Temperature | -45 C ~ 60 C |
Operating Humidity | 10%- 90% RH |
Waterproof Degree | IP65 |
Adjustable Door Relay time | 0 -99 seconds |
Wiegand Interface | Wiegand 26 bit |
Wiring Connections | Electric Lock, Exit Button, External Alarm |
Installation
Remove the back cover from the keypad using the supplied special screwdriver Drill 2 holes on the wall for the self-tapping screws and dig a hole for the cable Put the supplied rubber bungs into the two holes Fix the back cover firmly on the wall with 2 self-tapping screws Thread the cable through the cable hole Attach the keypad to the back cover.
Wiring
Colour | Function | Descrip tion |
---|---|---|
Pink | BELL_A | Doorbell button one end (optional) |
Pink | BELL_B | Doorbell button to the other end (optional) |
Green | DO | WG output DO |
White | 01 | WG output 0 1 |
Yellow | OPE N | Exit button one end(the other end connected GND) |
Red | 12V+ | 12V + DC Regulated Power Input |
Black | GND | 12V – DC Regulated Power Input |
Blue | NO | Relay normally-on end(Connect positive electric lock K_K) |
Purple | COM | Relay Public end, connect GNO |
Orange | NC | Relay Closed end(connect negative electric lock”-“) |
To Reset to Factory Default
- Power on, when LED light turns orange, press “#” key and release it immediately.
- On hearing “didi” sounds twice, system is back to factory settings. Registered users won’t be deleted when reset to factory default
Sound and Light indication
Operation Status | Red Light | Green Light | Buzzer | Mark |
---|---|---|---|---|
Power on | Bright | o; | ||
Stand by | Slow flash | |||
Press keypad | o; | |||
Operation successful | Bright | Di- | ||
Operation failed | DiDiDi | |||
Enter into programming mode | Bright | Di- | LED:orange | |
In the programming mode | o; |
Exit from the programming
mode
| ****
Slow flash
| | ****
Di-
|
Open the door| | Bright| Di-|
Alam,| Quick flash| | Alarm|
Detailed Programming Guide
User Settings
To enter lhe programming mooe
| * Master code #
999999 is the default factory master code
---|---
To exit from the programming mcxle
|
Note that to undertake the following programming the master user must be
logged in
To change the master cxx:le
| ****
0 New code # New cxx:le #
The master cxx:le can be 6 to 8 digits long
Setting the working mode:
| ****
3
| ****
0
| ****
| ****
Entry is by card only
Set valid card only users
Set valid card and PIN users Set valid card or PIN users
| 3
3
| 1
2
| # #| Entry is by card and PIN together Entry is by either card or PIN (default)
To add a Pin user
| 1 User ID number # PIN #
The ID number is any number between 1 & 2000. The PIN is any four digits between 0000 & 9999 with the exception of 1234 which is reserved. Users can be added continuously without exiting programming mode as follows:
1 UserIDno1 # PIN # UserIDno2 # PIN
---|---
To delete a PIN user
| 2 User ID number #
Users can be deleted cootinLIOUsly without exiting programming mode
To change the PIN of a PIN user (This step must be done out of programming mode)| |
ID number#
| |
Old PIN #
|
New PIN#
|
New PIN#
To add a card user (Method 1)
This is the fastest way to enter cards, user ID number auto generation
| 1 Read card #
Cards can be added continuously without exiting programming mode
To add a card user (Method 2)
This is the alternative way to enter cards using User ID Allocation. In this method a User ID is alkx:ated to a card. Only one user ID can be alkx:ated to a
single card
|
1 ID number # Read card #
User can be added cootinuously without exiting programming mode
To add a card use< (Method 3)
Card number is the last 8 digits printed on the bad< of the card.user ID number auto generation
|
1 Card number #
User can be added continuously without exiting programming mode
To add a card user (Method 4)
In this method a User ID is allocated to a card number. Only one user ID can be allocated to the card number
|
1 ID number# Gird num ber #
User can be added continuously without exiting programming mode
To delete a card user by card. Note users can be deleted continuously without exiting programming mode
|
2
|
Read Card
|
| | |
To delete a card user by user ID. This option can be used when a user has lost their card
|
2
|
User ID #
| | | |
To delete a card user by card number. This option can be used when the user want to make the change but the card has lost
| ****
2 Card number #
Note users can be deleted continuously without exiting programming mode
---|---
To add a card and PIN user in card and PIN mode ( 3 1 # )
To Add a card and Pin user
(The PIN is any four digits between 0000 & 9999 with the exc.eption of 1234 which is reserved.)
| Add the card as for a card user
Press • to exit from the programming mode Then allocate the card a PIN as follows:
• Read card 1234 # PIN# PIN#
To change a PIN in card and PIN mode (Method 1) Note that this is done outside programming mode so the user can undertake this themselves| ****
• Read Card Oki PIN # New PIN # New PIN#
To change a PIN in card and PIN mode (Method 2) Note that this is done outside programming mode so the user can undertake this themselves| ****
• ID number# Old PIN # New PIN# New PIN#
To delete a Gard and PIN user just delete the card| ****
2 User ID #
To add a card user in card mode ( 3 0 # )
To Add and Delete acard user
| The operating is the same as adding and deleting a card user in 3 2 #
To delete All u se r s
To delete ALL users. Note that this is a dangerous option so use with care|
2 0000 #
To unl oc k th e d oo r
For a PIN user Enter the PIN then press
For a card User Read card
For a card and PIN user I Read card then enter PIN#
Door Settings
Relay Outp ut Delay Ti me
To set door relay strike time
| • Master code # 4 0~ 99 #
0-99 is to set the door relay time 0-99 seconds
Alarm output time
To set the alarm output lime (0-3 minutes Factory default is 1 minute
I| ****
5
| 0_
3
| #
Keyp a d L o ckout & Buzzer A ctived . If there are 10 invalid cards or 10
incooect PIN numbers in a 10 minute period either the keypad will lockout for
10 minutes and the inside buzzer will operate for 1O minutes, depending on the
option selected below.
Normal status: No keypad lockout or buzzer operate (factory default)| | ****
7
| ****
O
| ****
(Factory default settings)
Keypad Lock.out| | 7| 1| #
Inside buzzer actived| | 7| 2| #
The unit operates as a Wiegand Output Reader
The unit supports a Wiegand 26 bit output, so the Wiegand data wires can be connected to any the controller which supports a Wiegand 26-bit input .
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>